Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reactor Metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Advanced Graphite Creep Uncertainty Analysis

Radiation damage estimation is an important component of the post irradiation analysis of the Advanced Graphite Creep (AGC) experiment. It depends primarily on the fast fluence, which is determined using well established methods of spectral adjustment. These are based on best estimates from models such as Monte Carlo N-Particle (MCNP), input cross-sections, and measured activities from flux wires in the experiment. Each of these parameters can propagate uncertainties which will affect the uncertainty in the calculated dose levels for AGC, or any experiment irradiated within a reactor. While the methods of propagating uncertainty are well-established, the final uncertainty estimates they provide are only as good as the estimates of uncertainty in the inputs on which they are based. The purpose of this work is to outline some deficiencies in the ways these input uncertainties are presently estimated, and to outline a methodology by which they can be improved. The fast fluence and radiation damage received by graphite specimens irradiated in the Advanced Graphite Creep (AGC) experiments is presently estimated using spectral adjustment methods that are based on both flux wire activity measurements, and MCNP model predictions. This work describes an ongoing effort to quantify and propagate uncertainties in inputs to the spectral adjustment process, and thereby quantify the resultant error in radiation damage (dpa) estimates. The effort is multi-faceted, and we consider the impacts of both the set of flux wires selected, and the counting process. An expanded set of flux wires is identified that provides a more comprehensive data set on the fast spectrum. To address the counting process itself, a series of round-robin measurements in several reactor metrology laboratories across the Department of Energy (DOE) complex and nuclear industry are being undertaken to refine the American Society for Testing and Materials (ASTM) standards for flux wire measurements. To address the contribution of uncertainty in the MCNP model predictions, an uncertainty quantification (UQ) tool has been developed that statistically samples the model input parameters, runs a series of cases, and assimilates the results to provide an overall uncertainty. The impact of the MCNP UQ tool results is demonstrated by re-analyzing previous AGC flux wire and irradiation data. While the expanded flux wire set obviously cannot be added to these experiments retroactively, plans for future graphite irradiations are outlined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensor Qualification for the Development of Advanced Reactors

A temperature sensor qualification device is undergoing development and testing in order to qualify temperature sensors for advanced reactor metrology applications. This device will provide National Institute of Standards and Technology (NIST) traceable performance testing of temperature sensors while under the high radiation environments experienced while in-core. This is completed by utilizing retractable sensors which transfer the measurements from ex-core to in-core sensors. A detailed discussion of the uncertainty propagation associated with this comparative process is provided. Experimental testing of the temperature distribution occurring in the device has begun and is reported on. It is pertinent to minimize this temperature distribution to prevent variation in sensor measurements. This variation will be indistinguishable from sensor drift for in-pile applications and would result in unnecessarily conservative uncertainty bounds.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Quantifying uncertainty in uranium concentration measurements via K-edge densitometry

This study quantifies the uncertainty in uranium concentration predictions of fluoride and chloride-based salts within a steel pipe using K-edge densitometry. Modeling and simulation was conducted with the Monte Carlo N-Particle Transport (MCNP) code. The quality of of this technique’s prediction in a pipe requires proper characterization of the pipe’s thickness, which is dependent on the source size and axial offset from the pipe centerline. The thickness was determined as either the center-line thickness seen by the X-ray source or an average value determined through random sampling. Generally, the predicted concentrations were slightly better at lower offset with the random sampling thickness and using the center-line thickness for the highest offsets. For a line-beam source and varying axial offsets, the relative error of concentration was within 1% of the true value but uncertainty increased by 2 orders of magnitude. Similarly, for no axial offset, the relative error was significantly less than 1% while no trend for uncertainty was found. However, at the largest possible offset for a given source size, the concentrations become erroneous and greater than the allowable 1% relative error. Furthermore, high offsets tended to increase the variance of the transmission spectra by 3 orders of magnitude.

Characterization and Analytical Technique↗

AGR-5/6/7 Irradiation Disassembly and Metrology First Look

The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program was established to perform research and development on tristructural isotropic (TRISO)-coated particle fuel to support deployment of high-temperature gas-cooled reactors (HTGRs), which are graphite-moderated nuclear reactors cooled with helium. This work continues as part of the Advanced Reactor Technologies (ART) TRISO Fuel Program. The overarching program goal is to provide a baseline fuel qualification data set to support licensing, deployment, and operation of HTGRs in the United States. To achieve these goals, the program includes fuel fabrication, irradiations of TRISO fuels and high-temperature materials (e.g., graphite), safety testing and post-irradiation examination (PIE), fuel performance modeling, and fission product transport and source term determination. The ART AGR program has conducted four distinct fuel irradiation experiments in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). The first of these irradiation tests, designated AGR-1, began in ATR in December of 2006 and ended in November 2009. This experiment was primarily to act as a shakedown test of the multi-capsule test train design and to provide early data on fuel performance that would be used in fuel fabrication process development. AGR-1 fuel kernels were produced on an engineering scale, but the TRISO coatings and cylindrical fuel compacts were fabricated on a laboratory scale. The AGR-1 PIE was completed and the final report was published in 2015. The second irradiation test, AGR-2, started in ATR in June 2010 and ended in October 2013. The AGR-2 irradiation test was designed to provide fuel performance data for coated particles fabricated on an engineering-scale pilot line using a coater with an internal chamber diameter of 150 mm (6 in.). The final PIE report was published in 2021. AGR-3/4, a single irradiation that combined what were originally conceived as the third and fourth tests, was to support the refinement of fission product transport models and to assess the effects of sweep gas impurities on fuel performance and fission product transport. PIE of the AGR-3/4 experiment is still in progress as of this writing. The subject of this report is AGR-5/6/7, the final qualification test of AGR TRISO fuel made entirely at the engineering scale.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advancements in PTFE/EPR Reactor Dosimetry

Discussion of current efforts by Radiation Metrology Laboratory at Sandia to continue development and deployment of an EPR/PTFE dosimetry system.

Vehar, David W. [Sandia National Laboratories (SNL↗

IRDFF-II: A New Neutron Metrology Library

High quality nuclear data is the most fundamental underpinning for all neutron metrology applications. This paper describes the release of version II of the International Reactor Dosimetry and Fusion File (IRDFF-II) that contains a consistent set of nuclear data for fission and fusion neutron metrology applications up to 60 MeV neutron energy. The library is intended to support: a) applications in research reactors; b) safety and regulatory applications in the nuclear power generation in commercial fission reactors; and c) material damage studies in support of the research and development of advanced fusion concepts. The paper describes the contents of the library, documents the thorough verification process used in its preparation, and provides an extensive set of validation data gathered from a wide range of neutron benchmark fields. The new IRDFF-II library includes 119 metrology reactions, four cover material reactions to support self-shielding corrections, five metrology metrics used by the dosimetry community, and cumulative fission products yields for seven fission products in three different neutron energy regions. In support of characterizing the measurement of the residual nuclei from the dosimetry reactions and the fission product decay modes, the present document lists the recommended decay data, particle emission energies and probabilities for 68 activation products. It also includes neutron spectral characterization data for 29 neutron benchmark fields for the validation of the library contents. Additional six reference fields were assessed (four from plutonium critical assemblies, two measured fields for thermal-neutron induced fission on 233U and 239Pu targets) but not used for validation due to systematic discrepancies in C/E reaction rate values or lack of reaction-rate experimental data. Another ten analytical functions are included that can be useful for calculating average cross sections, average energy, thermal spectrum average cross sections and resonance integrals. The IRDFF-II library and comprehensive documentation is available online at www-nds.iaea.org/IRDFF/. Evaluated cross sections can be compared with experimental data and other evaluations at www-nds.iaea.org/exfor/endf.htm. The new library is expected to become the international reference in neutron metrology for multiple applications.

IAEA IRDFF↗

Alternatives to NIST Cf-252 Iirradiations for Transfer Calibration of S-32 Neutron Monitors

Gas-flow proportional counting systems are used by the Radiation Metrology Laboratory (RML) at Sandia National Laboratories for reactor fluence monitoring with the 32 S(n,p) 32 P reaction. Calibration of these systems has traditionally been accomplished by fluence-transfer irradiations at the NIST 252 Cf facility. Such calibrations have become increasingly difficult as the NIST 252 Cf source decayed to unusable levels. To minimize the risk to the testing programs from an inability to properly calibrate these systems, the RML has developed two alternative calibration techniques: 1) development and implementation of certified 32 P sources for activity calibrations and subsequent calculation of neutron fluence, and 2) direct counting of non-certified reactor-irradiated sulfur pellets by liquid scintillation counting to determine 32 P activity for the subsequent calibration of gas-flow proportional counters. Preliminary comparisons show that the several calibration methods are capable of overall uncertainties within about 5 percent.

Vehar, David W.↗

Two-color scattering for the measurement of neutrals at the edge of fusion devices

Laser two-color scattering (TCS) is proposed to detect the neutral species in the edge of fusion devices, namely, tokamaks. Here, TCS uses two wavelengths to probe both the laser Rayleigh scattering and Thomson scattering of the neutral-electron bath, with emphasis on neutral density measurements such as that of hydrogen and deuterium. Modeling of the Rayleigh scattering of tokamak neutral species under various plasma conditions (electron density and temperature) shows that, with an appropriate filtering of the Thomson signal and by going to ultraviolet-region wavelengths, identification of the Rayleigh signal can be achieved. Photon count and signal fractions are calculated in two test cases, one in the midplane region of the National Spherical Torus Experiment and one in the divertor region of DIII-D. An uncertainty analysis and discussion of the feasibility of the TCS diagnostic is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Godiva IV central cavity neutron environment characterization with threshold neutron detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high-purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

Whitman, Nicholas H.↗

Annular Core Research Reactor (ACRR) Pulse Curve Characterization

Reactor pulse characterization at the Annular Core Research Reactor (ACRR) at Sandia Technical Area V (TA-V) is commonly done through photo conductive detection (PCD) and calorimeter detectors. Each of these offer a mode of analyzing a digital signal with different advantages/methods for determination of integrated dose or temporal based metrology. This report outlines a method and code that takes the millions of data points from such detectors and delivers a characteristic pulse trendline through two main methods: digital signal filtration and machine learning, in particular, Support Vector Machines (SVMs). Each method's endpoint is to deliver a characteristic curve for the many bucket environments of ACRR while considering other points of interest including delayed gamma removal for prompt dose metrics. This work draws and adds on previous work detailing the delayed gamma fraction contributions from CINDER simulations of the ACRR. Results from this project show a method to determine characteristic curves in a way that has previously been limited by data set size.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Directional dependence of equilibrated TLD-400 chips in multiple radiation fields

Fielding of thermoluminescent dosimeters (TLDs) for measurement of photon radiation dose in experiments is the standard practice for γ-irradiation facilities, pulsed power x-ray facilities, and reactor facilities at Sandia National Laboratories (SNL). Due to the high-dose experimental conditions and the mixed ( 1 n, γ) fields in these facilities, SNL radiation metrologists have historically used CaF 2 :Mn TLDs (also known as TLD-400). Recent inquiries to the radiation metrology staff have raised concerns that the aluminum-equilibrated TLD-400 chips may exhibit a directionally dependent response. The metrologists were asked whether the dose measured by the chip may be impacted by the angle of incidence on the equilibrated TLD. To provide a thorough answer to this query, a set of adjoint Monte Carlo radiation transport calculations was performed for three different equilibrated TLDs as well as bare TLD chips using the Integrated Tiger Series (ITS) code. The key feature of the adjoint calculations performed in this study is that each photon escaping the modeled geometry was tallied into angular bins to provide information on both the energy and angular dependence of the equilibrated chip. After the adjoint Monte Carlo calculations were completed, the resulting energy-dependent response function for each angular bin was convolved with multiple photon energy spectra representing various radiation facilities at SNL. The radiation facilities selected for analysis span a range of photon energies from approximately 1 keV up to approximately 20 MeV. Thus, the presented results are applicable to a wide variety of radiation facilities around the world. Although the bare TLD-400 chip was expected to display the largest variation due to the photon angle of impact on the dosimeter, the dosimeter with the thinnest aluminum equilibrator (SNL thin equilibrated TLD-400) was determined to have the biggest differential between the impact angle with the maximum dose ( D max ) and the impact angle with the minimum dose ( D min ). However, the SNL normal equilibrated TLD-400 chip demonstrated a dramatic reduction in that differential between maximum and minimum dose angles. The reduction in this differential is one of the dominant factors in experimenters’ choice to field these dosimeters at SNL radiation facilities. The results from the PNNL (Hanford) energy-flattening field capsule are consistent with the previous publications. The differential dose responses due to the photon impact angle indicate that experimenters should strive to field their TLD-400 dosimeters in a consistent manner to avoid additional uncertainty in the measurements based on dosimeter orientation.

Adjoint radiation transport↗

Godiva IV Central Cavity Neutron Environment Characterization with Threshold Neutron Detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235 U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Burst characteristics of advanced accident-tolerant FeCrAl cladding under temperature transient testing

Here assessment of burst characteristics of accident-tolerant fuel (ATF) claddings is essential to evaluate the safety margins of nuclear reactors, and better understanding can enable accelerated licensing for reactor concepts that include the new materials. Therefore, this study investigated the burst behavior of an ATF candidate of C26M, which is an iron–chromium–aluminum alloy (FeCrAl) under transient testing like the simulated loss-of-coolant accident (LOCA) conditions, except the water-quenching phase, in light-water reactors (LWRs). The effect of LOCA specimen length was assessed in terms of post-burst tube parameters. No critical length effect was determined on the burst pressure, burst location, and burst size measurements. Burst temperature showed larger variation likely due to its measurement approach used in this study. The post-test diametral strain was identified as the critical parameter to reduce the specimen length as compared to tube burst length or width. Postmortem optical metrology and digital image correlation were employed to determine the local strain-state during the simulated LOCA, which showed the loading path was close to equibiaxial conditions in regions away from the burst location, rather than internally pressurized conditions (or “plane-strain” tension). Pst-test microstructural characterizations of the FeCrAl revealed that ductile damage was present at the edge of the outer radial surface while the rest of the material was ruptured via cleavage at LOCA burst temperatures. Furthermore, internal grain boundary cracks were observed at locations away from the tube burst region. This behavior was considered to occur during the cooling down period of the simulated LOCA test. Overall, this study aimed to provide essential data for fuel performance code development by considering micromechanics of the deformation and failure.

36 MATERIALS SCIENCE↗

ROADRUNNER uranium nitride MiniFuel: Experimental design, fabrication and pre-irradiation baseline characterization for accelerated burnup testing

Uranium nitride (UN) is a promising fuel candidate for advanced reactor systems owing to its high uranium density and thermal conductivity; however, its qualification remains constrained by the scarcity of well-controlled irradiation performance data. Here, to address this limitation, the ROADRUNNER (Research On ADvancing the peRformance of UraNium Nitrides in Extreme enviRonments) campaign employs the MiniFuel platform in the High Flux Isotope Reactor (HFIR) to enable accelerated burnup irradiation testing under tightly controlled and largely isothermal conditions. This paper presents the experimental design, fuel fabrication, and pre-irradiation baseline characterization of the ROADRUNNER UN MiniFuel campaign. Thirty-six UN minidisc specimens were fabricated with systematically varied as-fabricated density (86–96% of theoretical density), carbon impurity content (961–5240 ppm), oxygen content (≤ ∼2000 ppm), and grain size (2.5–24 μm). The irradiation matrix spans nominal fuel temperatures of 873 K, 1173 K, and 1473 K and target burnups of 3.75%, 6.0%, and 7.5% fissions per initial metal atom (FIMA). Neutronic and thermal analyses were performed to define specimen-specific burnup accumulation and temperature histories, establishing the boundary conditions for subsequent in-pile behavior. Comprehensive pre-irradiation characterization—including dimensional metrology, density verification, impurity analysis, X-ray diffraction, Raman spectroscopy, scanning electron microscopy, X-ray computed tomography, and confocal profilometry—provides a detailed baseline for post-irradiation examination. Pre-irradiation data were further used to generate predictive estimates of fission gas release and swelling using existing empirical correlations. This quantitative comparison reveals substantial inter-model divergence at intermediate and elevated temperatures that exceeds propagated input uncertainties, highlighting structural gaps in the historical irradiation database. The ROADRUNNER irradiation campaign is currently underway in HFIR, with initial firs cycle completed in late 2025 and remaining targets scheduled through 2027. The experimental design and baseline dataset presented here establish the framework needed to interpret forthcoming post-irradiation measurements and to provide discriminating data for the validation and refinement of physics-based UN fuel performance models.

Lopes, Denise Adorno [Oak Ridge National Laborator↗

Atomic layer deposition of sodium fluoride thin films

The need for advanced energy conversion and storage devices remains a critical challenge amid the growing worldwide demand for renewable energy. Metal fluoride thin films are of great interest for applications in lithium-ion and emerging rechargeable battery technologies, particularly for enhancing the stability of the electrode-electrolyte interface and thereby extending battery cyclability and lifetime. Reported within, sodium fluoride (NaF) thin films were synthesized via atomic layer deposition. NaF growth experiments were carried out at reactor temperatures between 175 and 250 °C using sodium tert-butoxide and HF-pyridine solution. Here, the optimal deposition temperature range was 175–200 °C, and the resulting NaF films exhibited low roughness (R q ≈ 1.6 nm for films of ~8.5 nm), nearly stoichiometric composition (Na:F = 1:1.05) and a growth per cycle value of 0.85 Å/cycle on SiO 2 substrates. These results are encouraging for future applications of NaF thin films in the development of improved energy capture and storage technologies.

25 ENERGY STORAGE↗

Destructive PIE and Safety Testing of Six AGR-2 UO 2 Capsule 3 Compacts

The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program’s second irradiation experiment (AGR-2) was irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) from June 2010 to October 2013 (Collin 2014). The fuel compacts in this experiment held either tristructural isotropic (TRISO)-coated spherical kernels of uranium oxide (UO2) or TRISO-coated kernels containing both uranium carbide and uranium oxide phases (UCO). There were six separately monitored and controlled capsules in the AGR-2 test train. Capsule 3 held twelve compacts containing UO2-TRISO particles fabricated by BWX Technologies Nuclear Operations Group. The AGR-2 TRISO particles were fabricated in a pilot-scale fluidized-bed chemical vapor deposition (FB-CVD) furnace with a coating chamber inner diameter of 150 mm (Phillips, Barnes, and Hunn 2010), which was a change from the first irradiation experiment (AGR-1) particles that had been coated in a lab-scale FB-CVD coating system with a chamber inner diameter of 50 mm (Lowden 2006). The TRISO particles were overcoated with resinated graphite flake at Oak Ridge National Laboratory (ORNL), and the overcoated particles were pressed into one-inch-long, half-inch-diameter cylinders (Hunn, Montgomery, and Pappano 2010). Each cylindrical compact held an average of 1,543 TRISO particles with 9.6% enriched UO2 kernels that had a nominal diameter of 500 μm (Hunn, Savage, and Silva 2012). Capsule 3 compacts were irradiated to average calculated burnups of 9.01–10.69% fissions per initial metal atom (FIMA), and the average calculated fluences of fast neutrons with energies E n > 0.18 MeV were 3.05–3.53×10 25 n/m 2 (Sterbentz 2014). The calculated time-average, volume-average Capsule 3 compact temperatures were 996–1,062°C. However, Capsule 3 compact temperatures varied several hundred degrees across each compact, and the timeaverage minimum (TA min ) and time-average maximum (TA max ) temperatures were between 889–999°C and 1,072–1,105°C, respectively (Hawkes 2014). After irradiation, the AGR-2 test train was transferred from ATR to the INL Materials and Fuels Complex for inspection and disassembly (Ploger, Demkowicz, and Harp 2015). The initial inspection included dimensional metrology of the compacts and graphite fuel holders. Like all the AGR-2 compacts, the compacts in Capsule 3 shrank slightly during irradiation, as expected, with an average length reduction of 1.07–1.24% and an average diameter reduction of 0.13–0.41%. Post-irradiation examination (PIE) of the capsule components was completed to measure select fission products ( 90 Sr, 110m Ag, 134 Cs, 137 Cs, 144 Ce, and 154 Eu) outside the compacts (Stempien and Demkowicz 2020). This involved gamma counting of the graphite and graphoil spacers at the top and bottom of each capsule, acid leaching for radiochemical analysis of fission products on the metallic capsule components, and burn-leach analysis of the graphite holders. The total amount of 110mAg measured on the Capsule 3 components was 13% of the calculated capsule inventory. This was significantly lower than the amount of 110m Ag measured on the three UCO capsule components, which ranged from 32–70%. The lower 110m Ag release in Capsule 3 was likely due to lower peak temperatures compared with the UCO fuel capsules (Hawkes 2014). Measured inventories of the other select fission products were also lower in Capsule 3.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗