Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Suggested reference values for regional blood volumes in children and adolescents

Estimates of regional blood volumes (BVs) in humans are needed in dosimetric models of radionuclides and radiopharmaceuticals that decay in the circulation to a significant extent. These values are also needed to refine models of tissue elemental composition in computational human phantoms of both patients and exposed members of the general public. The International Commission on Radiological Protection (ICRP) in its Publication 89 provides reference values for total blood content in the full series of their reference individuals, to include the male and female newborn, 1 year-old, 5 year-old, 10 year-old, 15 year-old, and adult. Furthermore, Publication 89 provides reference values for the percentage distribution of total blood volume in 27 different blood-filled organs and tissues of the reference adult male and adult female. However, no similar distribution values are provided for non-adults. The goal of the present paper is to present a volumetric scaling methodology to derive these values for the same organs and tissues at ages younger than the reference adult. Finally, literature data on organ-specific vascular growth in the brain, kidneys, and skeletal tissues are also considered.

60 APPLIED LIFE SCIENCES↗

Interpreting Mobile and Handheld Air Sensor Readings in Relation to Air Quality Standards and Health Effect Reference Values: Tackling the Challenges

The US Environmental Protection Agency (EPA) and other federal agencies face a number of challenges in interpreting and reconciling short-duration (seconds to minutes) readings from mobile and handheld air sensors with the longer duration averages (hours to days) associated with the National Ambient Air Quality Standards (NAAQS) for the criteria pollutants-particulate matter (PM), ozone, carbon monoxide, lead, nitrogen oxides, and sulfur oxides. Similar issues are equally relevant to the hazardous air pollutants (HAPs) where chemical-specific health effect reference values are the best indicators of exposure limits; values which are often based on a lifetime of continuous exposure. A multi-agency, staff-level Air Sensors Health Group (ASHG) was convened in 2013. ASHG represents a multi-institutional collaboration of Federal agencies devoted to discovery and discussion of sensor technologies, interpretation of sensor data, defining the state of sensor-related science across each institution, and provides consultation on how sensors might effectively be used to meet a wide range of research and decision support needs. ASHG focuses on several fronts: improving the understanding of what hand-held sensor technologies may be able to deliver; communicating what hand-held sensor readings can provide to a number of audiences; the challenges of how to integrate data generated by multiple entities using new and unproven technologies; and defining best practices in communicating health-related messages to various audiences. This review summarizes the challenges, successes, and promising tools of those initial ASHG efforts and Federal agency progress on crafting similar products for use with other NAAQS pollutants and the HAPs.

54 ENVIRONMENTAL SCIENCES↗

Defining blood hematology reference values in female pig-tailed macaques ( Macaca nemestrina ) using the Isolation Forest algorithm

Background: Pig-tailed macaques (PTMs) are commonly used as preclinical models to assess antiretroviral drugs for HIV prevention research. Drug toxicities and disease pathologies are often preceded by changes in blood hematology. To better assess the safety profile of pharmaceuticals, we defined normal ranges of hematological values in PTMs using an Isolation Forest (iForest) algorithm. Methods: Eighteen female PTMs were evaluated. Blood was collected 1–24 times per animal for a total of 159 samples. Complete blood counts were performed, and iForest was used to analyze the hematology data to detect outliers. Results: Median, IQR, and ranges were calculated for 13 hematology parameters. From all samples, 22 outliers were detected. These outliers were excluded from the reference index. Conclusions: Using iForest, we defined a normal range for hematology parameters in female PTMs. This reference index can be a valuable tool for future studies evaluating drug toxicities in PTMs.

59 BASIC BIOLOGICAL SCIENCES↗

Using an Absolute Cavity Pyrgeometer to Validate the Calibration of a Secondary Standard Pyrgeometer Outdoors, Independent from the Reference Value of the Atmospheric Longwave Irradiance

Accurate measurements of broadband outdoor longwave irradiance are important for renewable energy applications and the study of the atmosphere and climate change. A unique method of pyrgeometer calibration has been developed to improve the measurement uncertainty [1]. The results of this method yielded irradiance values within ±3 W/m 2 of those traceable to the World InfraRed Standard Group (WISG). This article describes a technique for validating this pyrgeometer calibration method using two Absolute Cavity Pyrgeometers (ACPs). The ACPs and pyrgeometer model PIR were deployed outdoors and the irradiance measured by the PIR was compared against the average irradiance measured by the two ACPs. The irradiance measured by the PIR was calculated using two equations, NREL equation and the Physikalisch Meteorologisches Observatorium Davos (PMOD) equation. The uncertainty with 95% confidence level ( U 95 ) of the irradiance measured by the PIR using NREL equation equaled ±3.51 W/m 2 with respect to SI and using PMOD equation U 95 equaled ±2.99 W/m 2 with respect to SI. These results suggest that the PIR calibration method might be useful in addressing the international need for a secondary standard pyrgeometer traceable to SI.

54 ENVIRONMENTAL SCIENCES↗

Using an Absolute Cavity Pyrgeometer to Validate the Calibration of a Transfer Standard Pyrgeometer Outdoors, Independent from the Reference Value of the Atmospheric Longwave Irradiance

A unique method of pyrgeometer calibration has been developed to improve the measurement uncertainty [1]. The results of this method yielded irradiance values within ±3 W/m2 of those traceable to the World InfraRed Standard Group (WISG). The ACPs and pyrgeometer model PIR were deployed outdoors, and the irradiance measured by the PIR was compared against the irradiance measured by ACP95F3. Based on the results it is possible to achieve an uncertainty of ± 3.51 W/m2. These results suggest that the PIR calibration method might be useful in addressing the international need for a secondary standard pyrgeometer traceable to SI.

absolute cavity pyrgeometer↗

Impact of neutron irradiation on the thermophysical properties of additively manufactured stainless steel and inconel

The deployment of additive manufacturing (AM) technologies to support the nuclear energy industry is limited by the current lack of data related to the irradiation performance of AM parts. The Colorado School of Mines is conducting a multi-year irradiation and post irradiation examination project to study the impacts of neutron irradiation on stainless steel 316L and Inconel 718 and 625 specimens produced by several commercially available AM techniques and irradiated in the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL). This paper presents initial results on the impact of neutron irradiation on the heat capacity, the thermal diffusivity, and the thermal conductivity of the specimens at temperatures between 100 oC and 400 oC. The unirradiated AM specimens have heat capacity values similar to, or lower than, the reference values, regardless of manufacturing method or material. The irradiated AM specimens have average heat capacities greater than the unirradiated specimens and reference values in every case. Additionally, the thermal diffusivities of the unirradiated AM specimens are either larger or statistically similar to the reference values. The irradiated AM specimens exhibit lower thermal diffusivities compared to the reference thermal diffusivity values. One of the stainless steel 316L laser powder bed fusion samples exhibited thermal diffusivity values with statistically significant anisotropy prior to and after irradiation. The thermal conductivities of the unirradiated AM stainless steel 316L specimens and the unirradiated Inconel 718 specimens are lower or statistically similar to the reference values. The unirradiated Inconel 625 specimens exhibit slightly higher thermal conductivity values than the reference values. The irradiated specimens show a significant increase in thermal conductivity compared to the unirradiated specimens and the reference values for all materials.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integrated circuit authentication from a die material measurement

The various technologies presented herein relate to measuring a signal generated by a die-based test circuit incorporated into an IC, and utilizing the measured signal to authenticate the IC. The signal can be based upon a sensor response generated by the test circuit fabricated into the die, wherein the sensor response is based upon a property of the die material. The signal can be compared with a reference value obtained from one or more test circuit(s) respectively located on one or more reference dies, wherein the reference dies are respectively cut from different wafers, and the location at which the reference dies were cut is known. If the measured signal matches the reference value, the die is deemed to be from the same cut location as the dies from which the reference value was obtained. If the measured signal does not match the reference value, the die is not authenticated.

47 OTHER INSTRUMENTATION↗

Integrated circuit authentication from a die material measurement

The various technologies presented herein relate to measuring a signal generated by a die-based test circuit incorporated into an IC and utilizing the measured signal to authenticate the IC. The signal can be based upon a sensor response generated by the test circuit fabricated into the die, wherein the sensor response is based upon a property of the die material. The signal can be compared with a reference value obtained from one or more test circuit(s) respectively located on one or more reference dies, wherein the reference dies are respectively cut from different wafers, and the location at which the reference dies were cut is known. If the measured signal matches the reference value, the die is deemed to be from the same cut location as the dies from which the reference value was obtained. If the measured signal does not match the reference value, the die is not authenticated.

Zortman, William A.↗

An improved scaling procedure for analysis and simplification of process models

Systematic scaling analysis of model equations can be valuable as a tool for developing computationally tractable simulations of physical systems. The scaling analysis methods in literature pose difficulties in the calculation of scale and reference values, when nonlinear terms are involved in the model equations. Further, existing methods involve trial and error procedures in the scaling process. Here in this paper, a systematic approach for handling nonlinear terms is suggested, which results in appropriate scale and reference values that render the dimensionless variable variations to be of order one. Further, trial and error procedures are avoided through a new approach wherein a set of nonlinear algebraic equations are solved to identify the scale and reference values. The proposed scaling approach is common to any given model equations with fixed parameters. However, it is to be noted that the proposed procedure may not handle situations when model equations exhibit steady state multiplicity and have dynamic multi-mode regimes. The proposed scaling procedure is illustrated through various examples of different complexities. A 1D model of WGS reactor as a case study shows the effectiveness of the obtained scale and reference values in obtaining simplified model which represents the steady state and dynamic variations of the variables.

42 ENGINEERING↗

RCSED—A Value-added Reference Catalog of Spectral Energy Distributions of 800,299 Galaxies in 11 Ultraviolet, Optical, and Near-infrared Bands: Morphologies, Colors, Ionized Gas, and Stellar Population Properties

We present RCSED, the value-added Reference Catalog of Spectral Energy Distributions of galaxies, which contains homogenized spectrophotometric data for 800,299 low- and intermediate-redshift galaxies (0.007<z<0.6) selected from the Sloan Digital Sky Survey spectroscopic sample. Accessible from the Virtual Observatory (VO) and complemented with detailed information on galaxy properties obtained with state-of-the-art data analysis, RCSED enables direct studies of galaxy formation and evolution over the last 5 Gyr. We provide tabulated color transformations for galaxies of different morphologies and luminosities, and analytic expressions for the red sequence shape in different colors. RCSED comprises integrated k-corrected photometry in up to 11 ultraviolet, optical, and near-infrared bands published by the GALEX, SDSS, and UKIDSS wide-field imaging surveys; results of the stellar population fitting of SDSS spectra including best-fitting templates, velocity dispersions, parameterized star formation histories, and stellar metallicities computed for instantaneous starburst and exponentially declining star formation models; parametric and non-parametric emission line fluxes and profiles; and gas phase metallicities. We link RCSED to the Galaxy Zoo morphological classification and galaxy bulge+disk decomposition results of Simard et al. We construct the color–magnitude, Faber–Jackson, and mass–metallicity relations; compare them with the literature; and discuss systematic errors of the galaxy properties presented in our catalog. RCSED is accessible from the project web site and via VO simple spectrum access and table access services using VO-compliant applications. We describe several examples of SQL queries to the database. Finally, we briefly discuss existing and future scientific applications of RCSED and prospective catalog extensions to higher redshifts and different wavelengths.

79 ASTRONOMY AND ASTROPHYSICS↗

A Spatially Explicit Individual-Based Modeling Approach to Evaluate the Cumulative Effects of Wind Energy Development on the Greater Sage-Grouse: Sensitivity Analysis and Validation of Key Parameters

To address the need for an approach to evaluate cumulative ecological impacts of wind energy development, particularly those on critical wildlife habitats and species, the authors developed a proof-of-concept, landscape-based, spatially explicit individual-based modeling (IBM) framework for populations of the greater sage-grouse (Centrocercus urophasianus) in Albany County, Wyoming, based on published and other available information on the life history of the species. This sage-grouse IBM estimates the spatial and temporal movements of sage-grouse based on modeled effects of habitat characteristics and developments on sage-grouse condition, survivorship, and reproduction. After completing the initial version of the model, we conducted a series of sensitivity analyses of key model parameters and validation of lek occurrences and spatial distributions to better understand performance of the model relative to observed values of important life history characteristics. The parameter sensitivity analysis was conducted as a series of one-factor-at-a-time tests in which the values of selected parameters were individually varied to evaluate the corresponding effects on model output. We examined the model’s response to changes in parameter values to gain insight into the overall robustness of the model, identify key driver parameters, and initiate qualitative validation. Five functions selected for sensitivity analyses were (1) the rate of change in body condition in relationship to habitat suitability index (HSI) of occupied habitat (condition change rate), (2) the effect of competition between individuals with overlapping home ranges expressed as a percentage reduction in HSI (competition factor), (3) value of condition at which survivorship probability is equal to zero (zero survivorship condition), (4) the relationship between female body condition and clutch size, and (5) the relationship between female body condition and nest success. We varied the parameter values to be tested for the sensitivity analysis around the original value used in the model (i.e., tested values were higher and lower than the model’s original value) to examine the effect of this variation on the predicted output of the model. Model outputs evaluated in the sensitivity analysis included (1) predicted age-class distribution (as measured by the percentage of immature individuals within the population); (2) predicted sex ratio; (3) predicted age-sex class distribution (percent of population in each of six age-sex classes, i.e., male and female juveniles, yearlings, and adults); (4) lifespan; (5) population size; and (6) spatial distribution. Of the five parameters analyzed, condition change rate, survivorship, clutch size, and nest success did not substantially affect any of the evaluated model outputs. For the predicted age-class distribution, the percentage of immature individuals predicted by the model for these four parameters ranged from 61.9% to 65.0%, which was reasonable with respect to the reference values of 51.4 to 57.8% in published studies. The ratio of females to males ranged from 1.09 to 1.14, which was comparable to the reference values of 1.2 to 3.0 presented in an existing study. The predicted mean lifespan ranged from 1.62 to 1.74 years, which appears to be reasonable with respect to the reference values of 0.9 to 1.1 years for sharp-tail grouse and greater prairie chickens presented by published studies. The predicted population size ranged from 1,877 to 3,140. This prediction would be reasonable with respect to our estimate of 5,000 yearlings and adults, which was based on the USFWS estimate for the state of Wyoming scaled to the number of leks in the county. The predicted spatial distribution was not substantially affected by the parameter values examined. In our sensitivity analyses, the only tested parameter that had a noticeable effect on model output was competition factor. Over the range of values tested for this parameter, predicted population size exhibited the largest range (from 1,833 to 4,737) of all parameters tested. As the competition factor increased, the predicted population size decreased. This reflects the effect competition had on the number of individuals that could co occur in high-quality habitat patches. Despite this apparently significant effect, the range of values appears to be reasonable with respect to our estimate of 5,000 yearlings and adults, which was based on the USFWS estimate for the state of Wyoming scaled to the number of leks in the county.

17 WIND ENERGY↗

A linear, separable two-parameter model for dual energy CT imaging of proton stopping power computation

Purpose: To evaluate the accuracy and robustness of a simple, linear, separable, two-parameter model (basis vector model, BVM) in mapping proton stopping powers via dual energy computed tomography (DECT) imaging. Methods: The BVM assumes that photon cross sections (attenuation coefficients) of unknown materials are linear combinations of the corresponding radiological quantities of dissimilar basis substances (i.e., polystyrene, CaCl{sub 2} aqueous solution, and water). The authors have extended this approach to the estimation of electron density and mean excitation energy, which are required parameters for computing proton stopping powers via the Bethe–Bloch equation. The authors compared the stopping power estimation accuracy of the BVM with that of a nonlinear, nonseparable photon cross section Torikoshi parametric fit model (VCU tPFM) as implemented by the authors and by Yang et al. [“Theoretical variance analysis of single- and dual-energy computed tomography methods for calculating proton stopping power ratios of biological tissues,” Phys. Med. Biol. 55, 1343–1362 (2010)]. Using an idealized monoenergetic DECT imaging model, proton ranges estimated by the BVM, VCU tPFM, and Yang tPFM were compared to International Commission on Radiation Units and Measurements (ICRU) published reference values. The robustness of the stopping power prediction accuracy of tissue composition variations was assessed for both of the BVM and VCU tPFM. The sensitivity of accuracy to CT image uncertainty was also evaluated. Results: Based on the authors’ idealized, error-free DECT imaging model, the root-mean-square error of BVM proton stopping power estimation for 175 MeV protons relative to ICRU reference values for 34 ICRU standard tissues is 0.20%, compared to 0.23% and 0.68% for the Yang and VCU tPFM models, respectively. The range estimation errors were less than 1 mm for the BVM and Yang tPFM models, respectively. The BVM estimation accuracy is not dependent on tissue type and proton energy range. The BVM is slightly more vulnerable to CT image intensity uncertainties than the tPFM models. Both the BVM and tPFM prediction accuracies were robust to uncertainties of tissue composition and independent of the choice of reference values. This reported accuracy does not include the impacts of I-value uncertainties and imaging artifacts and may not be achievable on current clinical CT scanners. Conclusions: The proton stopping power estimation accuracy of the proposed linear, separable BVM model is comparable to or better than that of the nonseparable tPFM models proposed by other groups. In contrast to the tPFM, the BVM does not require an iterative solving for effective atomic number and electron density at every voxel; this improves the computational efficiency of DECT imaging when iterative, model-based image reconstruction algorithms are used to minimize noise and systematic imaging artifacts of CT images.

61 RADIATION PROTECTION AND DOSIMETRY↗

UV-filters and musk fragrances in seafood commercialized in Europe Union: Occurrence, risk and exposure assessment

Highlights: • Largest survey on UV-Fs and musks in seafood commercialized in Europe. • Farmed seabream showed the highest average concentration of UV-Fs. • Wild mackerel showed the highest average concentration of polycyclic musks. • UV-Fs and musks in raw samples were far below the estimated toxicological reference value. In the framework of the FP7 ECsafeSeafood project, 62 seafood samples commercialized in Europe Union from several representative species – mackerel, tuna, salmon, seabream, cod, monkfish, crab, shrimp, octopus, perch and plaice – were analysed for residues of 21 personal care products (PCPs), including 11 UV-filters (UV-Fs) and 10 musk fragrances (musks). PCPs analysis were performed by Quick, Easy, Cheap, Effective Rugged, Safe (QuEChERS), combined with liquid-liquid extraction (LLE) or dispersive solid-phase extraction (dSPE), followed by gas chromatography-tandem mass spectrometry (GC-MS/MS). The results showed the presence in a wide range of samples of nine out of eleven UV-Fs compounds analysed, namely 2-ethylhexyl salicylate (EHS), 2-ethylhexyl,4-methoxycinnamate (EHMC), 4-methylbenzylidenecamphor (4-MBC), benzophenone-1 (BP1), benzophenone-3 (BP3), isoamyl-4-methoxycinnamate (IMC), 2,2′-dihydroxy-4,4′-dimethoxybenzophenone (DHMB), homosalate (HS), and octocrylene (OC), whereas galaxolide (HHCB), galaxolide lactone (HHCB-lactone), and tonalide (AHTN) were the most found musks. The potential risks to human health associated with the exposure to eight of the more prevalent PCPs – EHS, EHMC, 4-MBC, BP1, BP3, IMC, HHCB, and AHTN - through seafood consumption were assessed for consumers from five European countries (Belgium, Ireland, Italy, Portugal and Spain). Results showed that the human exposure to UV-Fs and musks estimated from the concentration values found in seafood and the daily consumption of concerned seafood species, were far below toxicological reference values.

54 ENVIRONMENTAL SCIENCES↗

Validation of the TOPAS Monte Carlo toolkit for HDR brachytherapy simulations

The goal of this work is to validate the user-friendly Geant4-based Monte Carlo toolkit TOol for PArticle Simulation (TOPAS) for brachytherapy applications. Brachytherapy simulations performed with TOPAS were systematically compared with published TG-186 reference data. The photon emission energy spectrum, the air-kerma strength, and the dose-rate constant of the model-based dose calculation algorithm (MBDCA)-WG generic Ir-192 source were extracted. For dose calculations, a track-length estimator was implemented. Additionally, the four Joint AAPM/ESTRO/ABG MBDCA-WG test cases were evaluated through histograms of the local and global dose difference volumes. A prostate, a palliative lung, and a breast case were simulated. For each case, the dose ratio map, the histogram of the global dose difference volume, and cumulative dose-volume histograms were calculated. The air-kerma strength was (9.772 ± 0.001) × 10 -8 U Bq -1 (within 0.3% of the reference value). The dose-rate constant was 1.1107 ± 0.0005 cGy h -1 U -1 (within 0.01% of the reference value). For all cases, at least 96.9% of voxels had a local dose difference within [-1%, 1%] and at least 99.9% of voxels had a global dose difference within [-0.1%, 0.1%]. The implemented track-length estimator scorer was more efficient than the default analog dose scorer by a factor of 237. For all clinical cases, at least 97.5% of voxels had a global dose difference within [-1%, 1%]. Dose-volume histograms were consistent with the reference data. TOPAS was validated for high-dose-rate brachytherapy simulations following the TG-186 recommended approach for MBDCAs. Built on top of Geant4, TOPAS provides broad access to a state-of-the-art Monte Carlo code for brachytherapy simulations.

59 BASIC BIOLOGICAL SCIENCES↗

Low Level Calibration of Liquid Scintillation Counting

Liquid Scintillation Counting (LSC) is an analytical laboratory method that quantifies the concentrations of alpha and beta emitting isotopes. The LSC method can be utilized for the detection of tritium, both environmentally and at nuclear facilities. Most LSC samples are aqueous-based and prepared as a radioactive sample dissolved or suspended in a high efficiency scintillation cocktail that converts radioactive energy into light pulses. When placed in counting vials, the liquid scintillation cocktail allows for optical coupling in which energy is released from the samples radioactive decay, and transferred to the scintillator. That energy is then absorbed to produce excited electrons that fall back to their ground-state and emit a pulse of light that is detected by the liquid scintillation analyzers photomultiplier tubes. Quench is a signal attenuation due to physical, chemical, or color interferences. To compensate for quench, quench standards of a known concentration are implemented at increasing increments of quench per vial to create a quench curve. Quench standards can be purchased pre-made or customized from the manufacturer, however, there are several issues that arise from purchasing the pre-made quench standards. The main issues with ordering pre-made quench standards is that they use higher count values, between 30,000 and 250,000 disintegrations per minute (dpm) of tritium per vial and only come in glass vials. Using higher counting standards in glass vials makes it hard to see lower concentrations in plastic vials. Additionally, when using higher energy standards the accuracy of the calibration readings tend to be lower. On the other hand, making a set of quench standards in-house allows for the customization of the dpm concentration to roughly 1,500-3,000 and preparation in plastic vials. This allows for lower activity readings that results in closer precision of the samples' true concentration. Technical Objectives: Create a quench curve and calibrate the LSA for tritium. Verify the calibration of the quench curve prior to cross sample runs. Check calibration against Quality Control (QC) reference value. Conclusion: a tritium quench curve calibration was performed using a scintillation cocktail with ultima gold (AB and AB/F), acetone (only with AB), and water (only with AB/F). By performing the tritium quench curve calibration, the counting efficiency was correlated to various levels of quench. Calibration checks with quality control standards were also performed to verify that the calibration was correct. The observed results provided acceptable values that matched the quality control standard reference values with an acceptable uncertainty. The next step will be fine tuning and cross comparison checks with legacy instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)↗