Search NASA⌕ Search

SEARCH · Search NASA

Results for “References”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Can Kohn–Sham density functional theory predict accurate charge distributions for both single-reference and multi-reference molecules?

Dipole moments are the first moment of electron density and are fundamental quantities that are often available from experiments. An exchange–correlation functional that leads to an accurate representation of the charge distribution of a molecule should accurately predict the dipole moments of the molecule. It is well known that Kohn–Sham density functional theory (DFT) is more accurate for the energetics of single-reference systems than for the energetics of multi-reference ones, but there has been less study of charge distributions. Here, in this work, we benchmark 48 density functionals chosen with various combinations of ingredients, against accurate experimental data for dipole moments of 78 molecules, in particular 55 single-reference molecules and 23 multi-reference ones. We chose both organic and inorganic molecules, and within the category of inorganic molecules there are both main-group and transition-metal-containing molecules, with some of them being multi-reference. As one would expect, the multi-reference molecules are not as well described by single-reference DFT, and the functionals tested in this work do show larger mean unsigned errors (MUEs) for the 23 multi-reference molecules than the single-reference ones. Five of the 78 molecules have relatively large experimental error bars and were therefore not included in calculating the overall MUEs. For the 73 molecules not excluded, we find that three of the hybrid functionals, B97-1, PBE0, and TPSSh (each with less than or equal to 25% Hartree–Fock (HF) exchange), the range-separated hybrid functional, HSE06 (with HF exchange decreasing from 25% to 0 as interelectronic distance increases), and the hybrid functional, PW6B95 (with 28% HF exchange) are the best performing functionals with each yielding an MUE of 0.18 D. Perhaps the most significant finding of this study is that there exists great similarity among the success rate of various functionals in predicting dipole moments. In particular, of 39 functionals designed as general-purpose functionals and that do not have a global value of 100% HF exchange, the average MUE is 0.23 D, with a standard deviation of only 0.04 D. Among gradient approximations, which are especially interesting because of their speed and portability, the best overall performance is by PBE, HCTH/407, OLYP, OreLYP, and GAM, each with MUE of 0.22 D.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reference Cell Performance and Modeling on a One-Axis Tracking Surface: Preprint

Performance of five silicon-based reference cells is examined on a single-axis tracking surface. The reference cells' output are modeled using one-minute sampled spectral irradiance and reference cell temperature measurements. The model also incorporates spectral responsivity data for the reference cell. The transmission of light through the glazing multiplies the sum over all appropriate wavelengths of temperature adjusted reference cell responsivity times the measured spectral irradiance. Modeled reference cell output is compared with measured reference cell output under clear sky and totally cloudy sky conditions. For each reference cell the ratio of modeled to measured output varies by less than 2% over the year.

modeling↗

A coarse-graining approach for molecular simulation that retains the dynamics of the all-atom reference system by implementing hydrodynamic interactions

We report on a new approach for deriving coarse-grained intermolecular forces that retains the frictional contribution that is often discarded by conventional coarse-graining methods. The approach is tested for water and an aqueous glucose solution, and the results from the new implementation for coarse-grained molecular dynamics simulation show remarkable agreement with the dynamics obtained from reference all-atom simulations. The agreement between the structural properties observed in the coarse-grained and all-atom simulations is also preserved. We discuss how this approach may be applied broadly to any existing coarse-graining method where the coarse-grained models are rigorously derived from all-atom reference systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclear Science References Database

The Nuclear Science References (NSR) database together with its associated Web interface, is the world's only comprehensive source of easily accessible low- and intermediate-energy nuclear physics bibliographic information for more than 210,000 articles since the beginning of nuclear science. The weekly-updated NSR database provides essential support for nuclear data evaluation, compilation and research activities. The principles of the database and Web application development and maintenance are described. Examples of nuclear structure, reaction and decay applications are specifically included. The complete NSR database is freely available at the websites of the National Nuclear Data Center (http://www.nndc.bnl.gov/nsr) and the International Atomic Energy Agency (http://www-nds.iaea.org/nsr)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Correcting Density Functional Theory for Accurate Predictions of Compound Enthalpies of Formation: Fitted Elemental-Phase Reference Energies

Despite the great success that theoretical approaches based on density functional theory have in describing properties of solid compounds, accurate predictions of the enthalpies of formation ({Delta}H{sub f}) of insulating and semiconducting solids still remain a challenge. This is mainly due to incomplete error cancellation when computing the total energy differences between the compound total energy and the total energies of its elemental constituents. In this paper we present an approach based on GGA + U calculations, including the spin-orbit coupling, which involves fitted elemental-phase reference energies (FERE) and which significantly improves the error cancellation resulting in accurate values for the compound enthalpies of formation. We use an extensive set of 252 binary compounds with measured {Delta}H{sub f} values (pnictides, chalcogenides, and halides) to obtain FERE energies and show that after the fitting, the 252 enthalpies of formation are reproduced with the mean absolute error MAE = 0.054 eV/atom instead of MAE {approx} 0.250 eV/atom resulting from pure GGA calculations. When applied to a set of 55 ternary compounds that were not part of the fitting set the FERE method reproduces their enthalpies of formation with MAE = 0.048 eV/atom. Furthermore, we find that contributions to the total energy differences coming from the spin-orbit coupling can be, to a good approximation, separated into purely atomic contributions which do not affect {Delta}H{sub f}. The FERE method, hence, represents a simple and general approach, as it is computationally equivalent to the cost of pure GGA calculations and applies to virtually all insulating and semiconducting compounds, for predicting compound {Delta}H{sub f} values with chemical accuracy. We also show that by providing accurate {Delta}H{sub f} the FERE approach can be applied for accurate predictions of the compound thermodynamic stability or for predictions of Li-ion battery voltages.

36 MATERIALS SCIENCE↗

SU‐C‐105‐05: Reference Dosimetry of High‐Energy Electron Beams with a Farmer‐Type Ionization Chamber

Purpose: To investigate gradient effects and provide Monte Carlo calculated beam quality conversion factors to characterize the Farmer‐type NE2571 ion chamber for high‐energy reference dosimetry of clinical electron beams. Methods: The EGSnrc code system is used to calculate the absorbed dose to water and to the gas in a fully modeled NE2571 chamber as a function of depth in a water phantom. Electron beams incident on the surface of the phantom are modeled using realistic BEAMnrc accelerator simulations and electron beam spectra. Beam quality conversion factors are determined using calculated doses to water and to air in the chamber in high‐energy electron beams and in a cobalt‐60 reference field. Calculated water‐to‐air stopping power ratios are employed for investigation of the overall ion chamber perturbation factor. Results: An upstream shift of 0.3–0.4 multiplied by the chamber radius, r-cav, both minimizes the variation of the overall ion chamber perturbation factor with depth and reduces the difference between the beam quality specifier (R{sub 5} {sub 0}) calculated using ion chamber simulations and that obtained with simulations of dose‐to‐water in the phantom. Beam quality conversion factors are obtained at the reference depth and gradient effects are optimized using a shift of 0.2r-cav. The photon‐electron conversion factor, k-ecal, amounts to 0.906 when gradient effects are minimized using the shift established here and 0.903 if no shift of the data is used. Systematic uncertainties in beam quality conversion factors are investigated and amount to between 0.4 to 1.1% depending on assumptions used. Conclusion: The calculations obtained in this work characterize the use of an NE2571 ion chamber for reference dosimetry of high‐energy electron beams. These results will be useful as the AAPM continues to review their reference dosimetry protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

What Is the Reference? An Examination of Alternatives to the Reference Sources Used in IES TM-30-15

A study was undertaken to document the role of the reference illuminant in the IES TM-30-15 method for evaluating color rendition. TM-30-15 relies on a relative reference scheme; that is, the reference illuminant and test source always have the same correlated color temperature (CCT). The reference illuminant is a Planckian radiator, model of daylight, or combination of those two, depending on the exact CCT of the test source. Three alternative reference schemes were considered: 1) either using all Planckian radiators or all daylight models; 2) using only one of ten possible illuminants (Planckian, daylight, or equal energy), regardless of the CCT of the test source; 3) using an off-Planckian reference illuminant (i.e., a source with a negative Duv). No reference scheme is inherently superior to another, with differences in metric values largely a result of small differences in gamut shape of the reference alternatives. While using any of the alternative schemes is more reasonable in the TM-30-15 evaluation framework than it was with the CIE CRI framework, the differences still ultimately manifest only as changes in interpretation of the results. References are employed in color rendering measures to provide a familiar point of comparison, not to establish an ideal source.

CAM02-UCS↗

Primary Reference Cell Calibrations with Reduced Measurement Uncertainty

This paper presents an overview of the improvements made since 2014 to the primary reference cell calibrations performed at the National Renewable Energy Laboratory (NREL). Reducing the measurement uncertainty of the calibrations was the primary goal of the improvements, which were used during the recent calibrations conducted in the autumn of 2016. Changes and improvements have been made to the spectral irradiance and short-circuit current measurements, spectral irradiance modeling, and reference cell temperature corrections. Almost 6000 points were collected on 38 reference cells. Analysis of the results demonstrated reductions of expanded uncertainty from +/-1.0-1.2% in previous years down to +/-0.4-0.5% for crystalline-Si reference cells.

14 SOLAR ENERGY↗

Improved Primary Reference Cell Calibrations for Higher Accuracy Photovoltaic Cell and Module Performance Measurements

The adoption of photovoltaic (PV) modules for clean electricity relies on accurate measurements of their performance, which are essential for estimating their energy production potential. Herein, the calibration chain of PV cells and modules, with particular emphasis on primary reference cell calibrations, is discussed. Also, herein, the direct sunlight method the group has developed for these calibrations is presented and critical improvements and upgrades that lead to calibration uncertainty as low as 0.45% are discussed. The ultimate motivation behind this work is to provide low‐uncertainty performance measurements of PV modules, and lowering the calibration uncertainty of primary reference cells is a key first step toward achieving this goal. As the use of solar electricity continues to grow, the demand for primary reference cell calibrations inevitably increases beyond what the small handful of primary calibration laboratories can provide today. Therefore, this work can serve as a useful guide for implementing primary PV reference cell calibrations using the outdoor method, as well as outlining the critical elements required to make these calibrations highly accurate.

Osterwald, Carl R.↗

Reference Natural Gas Flames at Nominally Autoignitive Engine-Relevant Conditions

Laminar natural gas flames are investigated at engine-relevant thermochemical conditions where the ignition delay time r is short due to very high ambient temperatures and pressures. At these conditions, it is not possible to measure or calculate well-defined values for the laminar flame speed S-l, laminar flame thickness delta(l), and laminar flame time scale tau(l) = delta(l)/S-l due to the explosive thermochemical state. Here, the corresponding reference values, S-R, delta(R), and tau(R) = S-R/S-R, that account for the effects of autoignition, are numerically estimated to investigate the enhancement of flame propagation, and the competition with autoignition that arises under nominally autoignitive conditions (characterised here by the number tau/tau(R)). Large values of tau/tau(R) indicate that autoignition is unimportant, values near or below unity indicate that flame propagation is not possible, and intermediate values indicate that a combination of both flame propagation and autoignition may be important, depending upon factors such as device geometry, turbulence, stratification, et cetera. The reference quantities are presented for a wide range of temperatures, equivalence ratios, pressures, and hydrogen concentrations, which includes conditions relevant to stationary gas turbine reheat burners and boosted spark ignition engines. It is demonstrated that the transition from flame propagation to autoignition is only dependent on residence time, when the results are non-dimensionalised by the reference values. The temporal evolution of the reference values are also reported for a modelled boosted SI engine. It is shown that the nominally autoignitive conditions enhance flame propagation, which may be an ameliorating factor for the onset of engine knock. The calculations are performed using a recently-developed, detailed 177 species mechanism for C0-C3 chemistry that is derived from theoretical chemistry and is suitable for a wide range of thermochemical conditions as it is not tuned or optimised for a particular operating condition. (C) 2018 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

autoignition↗

Monte Carlo calculations for reference dosimetry of electron beams with the PTW Roos and NE2571 ion chambers

Purpose: To investigate recommendations for reference dosimetry of electron beams and gradient effects for the NE2571 chamber and to provide beam quality conversion factors using Monte Carlo simulations of the PTW Roos and NE2571 ion chambers. Methods: The EGSnrc code system is used to calculate the absorbed dose-to-water and the dose to the gas in fully modeled ion chambers as a function of depth in water. Electron beams are modeled using realistic accelerator simulations as well as beams modeled as collimated point sources from realistic electron beam spectra or monoenergetic electrons. Beam quality conversion factors are calculated with ratios of the doses to water and to the air in the ion chamber in electron beams and a cobalt-60 reference field. The overall ion chamber correction factor is studied using calculations of water-to-air stopping power ratios. Results: The use of an effective point of measurement shift of 1.55 mm from the front face of the PTW Roos chamber, which places the point of measurement inside the chamber cavity, minimizes the difference betweenR{sub 50}, the beam quality specifier, calculated from chamber simulations compared to that obtained using depth-dose calculations in water. A similar shift minimizes the variation of the overall ion chamber correction factor with depth to the practical range and reduces the root-mean-square deviation of a fit to calculated beam quality conversion factors at the reference depth as a function of R{sub 50}. Similarly, an upstream shift of 0.34 r{sub cav} allows a more accurate determination of R{sub 50} from NE2571 chamber calculations and reduces the variation of the overall ion chamber correction factor with depth. The determination of the gradient correction using a shift of 0.22 r{sub cav} optimizes the root-mean-square deviation of a fit to calculated beam quality conversion factors if all beams investigated are considered. However, if only clinical beams are considered, a good fit to results for beam quality conversion factors is obtained without explicitly correcting for gradient effects. The inadequacy of R{sub 50} to uniquely specify beam quality for the accurate selection of k{sub Q} factors is discussed. Systematic uncertainties in beam quality conversion factors are analyzed for the NE2571 chamber and amount to between 0.4% and 1.2% depending on assumptions used. Conclusions: The calculated beam quality conversion factors for the PTW Roos chamber obtained here are in good agreement with literature data. These results characterize the use of an NE2571 ion chamber for reference dosimetry of electron beams even in low-energy beams.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal Voltage Reference for Droop-Based DERs in Distribution Systems

Due to the newly issued standards on distributed energy resources (DERs), the droop-based operation modes (Q-V and P-V droops) become a requirement for all the interconnected DER units at the distribution level. Voltage references of the DER units can be assigned to improve the operational behavior of the distribution system in the smart grid context. This paper presents a novel formulation for optimally setting voltage reference of the droop-based DER units in distribution systems with the objective of minimizing the system ohmic loss. This problem is formulated as a mixed-integer quadratic convex optimization problem in MATLAB and solved by the MATLAB and CPLEX solvers. The IEEE 123-bus system and the EPRI test system Ckt5 are used to validate the proposed formulation. The result obtained from the proposed formulation is compared with the result of the original problem solved by the heuristic method. Based on the numerical study results, system loss can be reduced after the proposed voltage reference assignment. The computational expense of the new formulation is also much lower than that of the heuristic approach.

distributed energy resource integration↗

On the determination of reference levels for quality assurance of flattening filter free photon beams in radiation therapy

Purpose: New definitions for some dosimetric parameters for use in quality assurance of flattening filter free (FFF) beams generated by medical linear accelerators have been suggested. The present study aims to validate these suggestions and to propose possible reference levels. Methods: The main characteristics of FFF photon beams were described in terms of: field size, penumbra, unflatness, slope, and peak-position parameters. Data were collected for 6 and 10 MV-FFF beams from three different Varian TrueBeam Linacs. Measurements were performed with a 2D-array (Starcheck system from PTW-Freiburg) and with the portal dosimetry method GLAaS utilizing the build-in portal imager of TrueBeam. Data were also compared to ion chamber measurements. A cross check validation has been performed on a FFF beam of 6 MV generated by a Varian Clinac-iX upgraded to FFF capability. Results : All the parameters suggested to characterize the FFF beams resulted easily measurable and little variation was observed among different Linacs. Referring to two reference field sizes of 10 × 10 and 20 × 20 cm{sup 2}, at SDD = 100 cm and d = dmax, from the portal dosimetry data, the following results (averaging X and Y profiles) were obtained. Field size: 9.95 ± 0.02 and 19.98 ± 0.03 cm for 6 MV-FFF (9.94 ± 0.02 and 19.98 ± 0.03 cm for 10 MV-FFF). Penumbra: 2.7 ± 0.3 and 2.9 ± 0.3 mm for 6 MV-FFF (3.1 ± 0.2 and 3.3 ± 0.3 for 10 MV-FFF). Unflatness: 1.11 ± 0.01 and 1.25 ± 0.01 for 6 MV-FFF (1.21 ± 0.01 and 1.50 ± 0.01 for 10 MV-FFF). Slope: 0.320 ± 0.020%/mm and 0.43 ± 0.015%/mm for 6 MV-FFF (0.657 ± 0.023%/mm and 0.795 ± 0.017%/mm for 10 MV-FFF). Peak Position −0.2 ± 0.2 and −0.4 ± 0.2 mm for 6 MV-FFF (−0.3 ± 0.2 and 0.7 ± 0.3 mm for 10 MV-FFF). Results would depend upon measurement depth. With thresholds set to at least 95% confidence level from the measured data and to account for possible variations between detectors and methods and experimental settings, a tolerance set of: 1 mm for field size and penumbra, 0.04 for unflatness, 0.1%/mm for slope, and 1 mm for peak position could be proposed from our data. Conclusions : The parameters proposed for the characterization and routine control of stability of profiles of FFF beams appear to be a viable solution with a strong similarity to the conventional parameters used for flattened beams. The results from three different TrueBeams and the cross-validation against a Clinac-iX suggested the possible generalization of the methods and the possibility to use common tolerances for the parameters. The data showed also the reproducibility of beam characteristics among different systems (of the same vendor) and the resulting parameter values could therefore be possibly generalized.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simple Approximation for the Ideal Reference State of Gases Adsorbed on Solid-State Surfaces

Reference states are useful as models for facilitating calculations of equilibrium constants, and they may also serve as standard states that are convenient for organizing and tabulating thermodynamic data; however, standard state conventions and appropriate reference states for adsorbed species have received less attention than those for pure substances and solutes. Here, we compare seven choices of reference states for calculations of equilibrium constants and transition state theory rate constants for flat surfaces, in particular (1) an ideal 2D harmonic oscillator, (2) an ideal rigid-molecule harmonic oscillator, (3) an ideal 2D harmonic oscillator with separable surface modes, (4) a 2D ideal gas, (5) an ideal 2D hindered translator, (6) an ideal 2D hindered translator with lowest-order barriers, and (7) a simple ideal 2D hindered translator proposed in this work. The advantage of models 5–7 is that they can treat both mobile and localized adsorbates in a consistent way, whereas models 1–3 are only appropriate for localized adsorbates, and model 4 is only appropriate for a freely translating adsorbate. Furthermore, models 6 and 7 reduce the computational cost without the user having to calculate barrier heights for diffusion. An advantage of the simple ideal 2D hindered translator is that it has a physical high-temperature limit. We also propose a reference state for nonflat surfaces. Here, the user is encouraged to choose a reference state based on the appropriateness of the model and the practicality of the calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗