Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reflection Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Field Deployable Mirror Soiling Detection Based on Polarimetric Imaging

Heliostat mirror soiling is one of the significant factors for reduced optical efficiency of Concentrated Solar Power (CSP) fields. However, it remains challenging to determine the mirror soiling patterns across the large area of the CSP field. Here we propose a fast and field deployable inspection method to measure the heliostat mirror soiling levels based on polarization images in regular daylight settings without additional light sources. Under sunny and clear sky conditions, we have demonstrated accurate measurement of reflection efficiency (error ~1%) for mirrors with different soiling levels.

14 SOLAR ENERGY↗

In Situ MOF Pyrolysis Construction of Hierarchical Porous Co‐Nanoparticles/Carbon Cloth Composites for Enhanced Electromagnetic Wave Shielding and Absorption

The development of high-performance electromagnetic protection materials integrating broadband absorption and effective shielding capabilities is hindered by challenges in simultaneously optimizing multiple electromagnetic properties through conventional material designs. This study pioneers a hierarchical porous Co nanoparticle/carbon cloth (Co/CC) composite via controlled annealing of a Co-MOF precursor on carbon cloth. The Co-MOF served a dual role as both magnetic source and pore-forming agent, enabling in situ generation of uniformly dispersed Co nanoparticles and creation of abundant pores/interfaces on the CC fibers during pyrolysis. This unique architecture synergistically enhanced dielectric loss (via interfacial/dipolar polarization) and magnetic loss (via natural resonance, exchange interactions, and eddy currents), significantly improving impedance matching. The hierarchical pores further functioned as integrated “absorption–reflection” units for efficient electromagnetic energy attenuation. Consequently, the Co/CC composite annealed at 800°C (Co/CC-800) achieves minimum reflection loss (−40.69 dB) and 120% effective absorption bandwidth extension (6.16 GHz) as a filler, and exhibits superior electromagnetic interference shielding effectiveness (46.66 dB) as an integrated component. Significantly, Co/CC-800 demonstrated robust photothermal and electrothermal conversion capabilities, ensuring operational stability in ice-covered and humid harsh environments. This work pioneers a pore-structure-mediated strategy to harmonize dielectric–magnetic synergy, providing a new paradigm for designing advanced multifunctional electromagnetic protection materials.

dielectric‐magnetic synergy↗

Antireflective Multi‐Dielectric Metasurfaces Operating in the Visible

Abstract As increasingly more demanding photonics applications are brought on‐chip, more complex design solutions are employed to deliver enhanced performance: e.g., meta‐molecules, inverse‐designed freeform structures, and multilayer metasurfaces. Instead, this study introduces anti‐reflective metasurfaces fabricated in a single nanolithography step that follows deposition of multiple dielectrics onto a substrate. Anti‐reflective metasurfaces offer fundamentally better transmission efficiencies compared to conventional equivalents. Conventional and anti‐reflective metalenses, both fabricated in the Ta 2 O 5 /SiO 2 material platform for 461 nm operation, show an improvement in focusing efficiencies from ≈ 55% to ≈ 90% at low numerical apertures and from ≈ 35% to ≈ 65% at high numerical apertures. Simulations of ideal and imperfect metalenses indicate that anti‐reflective metasurfaces not only improve transmission at the design library level, but also reduce spurious diffraction and protect against higher‐order scattering.

Optics↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Heat Pump Rooftop Units with Standard Performance

This documentation focuses on a single end-use savings shape measure - heat pump rooftop units (HP-RTUs) with standard efficiencies that are prevalent in the current market. Today, these products are claimed as standard efficiency by the manufacturers and are most commonly installed. This document will primarily discuss the additional changes of performance and configuration of the standard efficiency HP-RTUs while a comprehensive overview of the fundamental modeling methodology and background of the HP-RTU measure, including applicability, sizing scheme, and other key assumptions can be found in the original documentation: Heat Pump RTU. The definition of "standard efficiency" can be a bit vague when considering detailed specifics other than efficiency metrics of a heat pump. Thus, we have focused on reflecting products where manufacturers claim as standard efficiency and products that are not top-of-the-line in their model lineup. Based on gathering information from eight products from four major manufacturers, there are some common (or relatively prevalent) characteristics and we have defined standard efficiency product as follows: direct drive outdoor unit fan, two stages of heat pump cooling, single stage heat pump heating (i.e., all compressors running at the same time), heat pump minimum lockout temperature of 0°F (-17.8°C), backup electric resistance heating, backup heating runs at the same time as heat pump heating , heat pump heating locking out below minimum operating temperature, IEER in between 11-13, and HSPF in between 8-8.9. There are cases where some of these products have other variations: a variable frequency drive fan, dual fuel (i.e., gas backup heating) option, three or more cooling stages, two stages of heat pump heating, no backup heating as default , etc. However, this work tried to reflect the most common and prevalent options for a standard efficiency product.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Impact of Radiative Cooling Paints in Warehouses Under Various United States Climates

Although radiative cooling research is widely found in the literature, no comprehensive study has yet been conducted on the impact of novel radiant cooling (>0.91 reflectance) on the energy efficiency of warehouses. Here, in this work, we develop three building models based on a Department of Energy prototype warehouse model using trnsys, representing a typical warehouse with a black roof, a typical warehouse with a white roof, and a warehouse with novel radiative cooling (RC) paint on its roof. These models are run for 15 different cities, each representative of a different ASHRAE climate zone, to better understand the impact of RC in many different climates. It was found that an RC-coated roof in a warehouse could reduce the building's annual heating, ventilation, and air conditioning (HVAC) loads by up to 14.11 kWh/m 2 of the roof area compared to a black roof, resulting in a maximum reduction in energy costs of 0.55 $\$$/m 2 or $\$$2646/year for a large 4835 m 2 warehouse. Similarly, replacing the typical white roof coating with an RC coating could reduce the warehouse's energy consumption by up to 8.17 kWh/ m 2 of roof area, thus reducing energy costs by as much as 0.29 $\$$/m 2 or $\$$1386/year for a 4835 m 2 warehouse. In addition, applying RC paint to an unconditioned warehouse could reduce the building's ASHRAE Standard 55 indoor temperature exceedance by up to 1330 h/year compared to a black roof and up to 532 h/year compared to a white roof.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-Cost Heliostat for High-Flux Small-Area Receivers (Final Technical Report)

This project analyzed a two-stage heliostat concept consisting of a tracking stage and a concentrating stage. The tracking stage uses mirrors mounted on a common drive that move to track the sun. The concentrating stage consists of stationary mirrors that each have a unique angle to direct rays towards a small-area, high-flux, point-focused receiver. By splitting the collection and concentrating process into two stages, multiple small, inexpensive mirrors can share a structure and be controlled by a single drive in the tracking stage. The project effort developed modeling techniques that were specifically relevant to this two-stage heliostat concept. Both field-level and unit-level models were developed. The field-level model does not explicitly consider unit-level losses which are predicted by the unit-level model and then integrated into the field-level model through a correlation referred to as an efficiency modifier. This approach is referred to as the two-model approach; the development and demonstration of this two-model approach for a multi-stage heliostat technology is a key outcome of this work. The field-level model is used to design a field that hits a specific design day power given a set of heliostat design parameters. An oversized field is simulated and then heliostat units are removed based on their annual energy production in order to generate the highest performing field. The field reduction procedure fits a smooth curve fit to annual energy production as a function of position in the field which has the effect of reducing the noise that is otherwise caused by the Monte Carlo ray tracing technique. This approach is referred to as the annual energy fit method and substantially reduces computational run time for a given field level modeling accuracy. The annual energy fit approach enables the selection of a properly sized, high-performing field using orders of magnitude fewer rays than would otherwise be possible and the development of this approach is a second key outcome of this work. These models are used within a genetic optimization algorithm in order to optimize the geometric parameters associated with a heliostat in order to achieve the lowest cost per unit of collected design day power. The cost modeling that underlies the optimization is a simple, scaling type analysis backed up by a much more detailed Design for Manufacture and Assembly (DFMA) analysis. Although the figure of merit used for optimization was not cost per mirror area, this metric is reasonable to use as a means of comparison. The optimally designed 500 kW design has a tracking mirror specific cost of $181.85/m 2 , which is significantly larger than the target value and also larger than the current state of the art. The cost of the torque-tube type linkages contributed substantially to the overall cost. Based on this observation, potentially attractive alternative design configuration utilizing a capstan type actuation system should be investigated. Finally, NREL compared the performance of the two-stage heliostat to the performance of a focused and different sized flat conventional heliostats and showed that, as expected, additional losses versus the convention heliostat caused by a worse cosine efficiency, two stages of reflection, and interstage interactions. The two-stage heliostat requires around 75% more reflective area than a flat 1x1 meter conventional heliostat (similar to a focused heliostat) and 40% more than a flat 2x2 meter conventional heliostat.

14 SOLAR ENERGY↗

Hyperspectral Reflectance-Based High Throughput Phenotyping to Assess Water-Use Efficiency in Cotton

Cotton is a pivotal global commodity underscored by its economic value and widespread use. In the face of climate change, breeding resilient cultivars for variable environmental conditions becomes increasingly essential. However, the process of phenotyping, crucial to breeding programs, is often viewed as a bottleneck due to the inefficiency of traditional, low-throughput methods. To address this limitation, this study utilizes hyperspectral remote sensing, a promising tool for assessing crucial crop traits across forty cotton varieties. The results from this study demonstrated the effectiveness of four vegetation indices (VIs) in evaluating these varieties for water-use efficiency (WUE). The prediction accuracy for WUE through VIs such as the simple ratio water index (SRWI) and normalized difference water index (NDWI) was higher (up to R2 = 0.66), enabling better detection of phenotypic variations (p < 0.05) among the varieties compared to physiological-related traits (from R2 = 0.21 to R2 = 0.42), with high repeatability and a low RMSE. These VIs also showed high Pearson correlations with WUE (up to r = 0.81) and yield-related traits (up to r = 0.63). We also selected high-performing varieties based on the VIs, WUE, and fiber quality traits. This study demonstrated that the hyperspectral-based proximal sensing approach helps rapidly assess the in-season performance of varieties for imperative traits and aids in precise breeding decisions.

Agriculture↗

Sub‐0.6 eV Inverted Metamorphic GaInAs Cells Grown on Inp and GaAs Substrates for Thermophotovoltaics and Laser Power Conversion

Abstract Inverted metamorphic Ga 0.3 In 0.7 As photovoltaic converters with sub‐0.60 eV bandgaps grown on InP and GaAs are presented. Threading dislocation densities are 1.3 ± 0.6 × 10 6 and 8.9 ± 1.7 × 10 6 cm −2 on InP and GaAs, respectively. The devices generate open‐circuit voltages of 0.386 and 0.383 V, respectively, under irradiance producing a short‐circuit current density of ≈10 A cm −2 , yielding bandgap‐voltage offsets of 0.20 and 0.21 V. Power and broadband reflectance measurements are used to estimate thermophotovoltaic (TPV) efficiency. The InP‐based cell is estimated to yield 1.09 W cm −2 at 1100 °C versus 0.92 W cm −2 for the GaAs‐based cell, with efficiencies of 16.8 versus 9.2%. The efficiencies of both devices are limited by sub‐bandgap absorption, with power weighted sub‐bandgap reflectances of 81% and 58%, respectively, the majority of which is assumed to occur in the graded buffers. The 1100 °C TPV efficiencies are estimated to increase to 24.0% and 20.7% in structures with the graded buffer removed, if previously demonstrated reflectance is achieved. These devices also have application to laser power conversion in the 2.0–2.3 µm atmospheric window. Peak laser power converter efficiencies of 36.8% and 32.5% are estimated under 2.0 µm irradiances of 1.86 and 2.81 W cm −2 , respectively.

14 SOLAR ENERGY↗

Data driven discovery and quantification of hyperspectral leaf reflectance phenotypes across a maize diversity panel

Abstract Estimates of plant traits derived from hyperspectral reflectance data have the potential to efficiently substitute for traits, which are time or labor intensive to manually score. Typical workflows for estimating plant traits from hyperspectral reflectance data employ supervised classification models that can require substantial ground truth datasets for training. We explore the potential of an unsupervised approach, autoencoders, to extract meaningful traits from plant hyperspectral reflectance data using measurements of the reflectance of 2151 individual wavelengths of light from the leaves of maize ( Zea mays ) plants harvested from 1658 field plots in a replicated field trial. A subset of autoencoder‐derived variables exhibited significant repeatability, indicating that a substantial proportion of the total variance in these variables was explained by difference between maize genotypes, while other autoencoder variables appear to capture variation resulting from changes in leaf reflectance between different batches of data collection. Several of the repeatable latent variables were significantly correlated with other traits scored from the same maize field experiment, including one autoencoder‐derived latent variable (LV8) that predicted plant chlorophyll content modestly better than a supervised model trained on the same data. In at least one case, genome‐wide association study hits for variation in autoencoder‐derived variables were proximal to genes with known or plausible links to leaf phenotypes expected to alter hyperspectral reflectance. In aggregate, these results suggest that an unsupervised, autoencoder‐based approach can identify meaningful and genetically controlled variation in high‐dimensional, high‐throughput phenotyping data and link identified variables back to known plant traits of interest.

Tross, Michael C.↗

InP- and GaAs-Based 0.6 eV GaInAs Devices for Thermophotovoltaics and Laser Power Conversion

Emerging applications such as thermal energy grid storage, waste heat recovery and portable power generation require efficient thermophotovoltaic (TPV) converters tuned to temperatures near 1000 Degrees Celsius or below. Metamorphic GaInAs with larger lattice constants than InP present a promising option for these needs. The ability to grow these devices on GaAs substrates instead of more expensive InP would enhance the scalability of these devices. In this talk, we present inverted metamorphic Ga0.3In0.7As photovoltaic converters with sub-0.60 eV bandgaps grown on InP and GaAs substrates. These devices are realized using InAsP or GaInP/InAsP compositionally graded buffers which exhibit threading dislocation densities of 1.3 +/- 0.6 x 106 cm-2 and 8.9 +/- 1.7 x 106 cm-2 on InP and GaAs, respectively. Despite this difference in defect density, the devices generate similar open-circuit voltages of 0.386 V and 0.383 V, respectively, under irradiance producing a short-circuit current density of -10 A/cm2, with bandgap-voltage offsets of 0.20 and 0.21 V. We estimate their thermophotovoltaic efficiency using these measurements coupled with broadband reflectance measurments. The InP-based cell is estimated to yield 1.09 W/cm2 at 1100 Degrees Celsius vs. 0.92 W/cm2 for the GaAs-based cell, with TPV efficiencies of 16.8 vs. 9.2%. Both devices are limited by sub-bandgap absorption, which we assess largely occurs in the graded buffers. We estimate that the 1100 Degrees Celsius thermophotovoltaic efficiencies would increase to 24.0% and 20.7% in structures with the graded buffer removed, if previously demonstrated reflectance is achieved. These devices also have application as laser power converters in the 2.0-2.3 um atmospheric window. We estimate efficiencies of 36.8% and 32.5% under 2.0 um monochromatic irradiance of 1.86 W/cm2 and 2.81 W/cm2, respectively.

ENGINEERING,MATERIALS SCIENCE,SOLAR ENERGY↗

Monocrystalline CdSeTe/MgCdTe Double‐Heterostructure Solar Cells

This article reports monocrystalline CdSeTe/MgCdTe double‐heterostructure (DH) solar cells with varying Se compositions in the absorber layers that are grown on InSb substrates by using molecular beam epitaxy. The Se composition in the samples studied is determined to be 4%–11% through high‐resolution X‐ray diffraction (XRD) and photoluminescence measurements. Increased Se incorporation induces higher defect density attributed to increased lattice mismatch, and mixed‐phase formation due to the small difference in formation energies between the wurtzite and zinc blende phases of CdSe, which causes stacking faults and grain boundaries. Devices are fabricated by directly depositing an n‐type indium tin oxide (ITO) layer on the CdSeTe/MgCdTe DHs followed by Ag metal contacts. Reduced bandgap is observed in solar cells with increased Se composition. The devices with an absorber containing 4% Se exhibit an average open‐circuit voltage ( V OC ) of 0.925 V, a short‐circuit current density ( J SC ) of 23.4 mA/cm 2 , a fill factor ( FF ) of 0.650 and an efficiency of 14.1% without anti‐reflection coating. Absorbers with higher Se compositions result in poor device performance, mainly attributed to high defect density in the materials.

Ju, Zheng [Center for Photonics Innovation Arizona↗

HIGHLY-EFFICIENT 20-MW L-BAND MULTI-BEAM KLYSTRON

The overall goal of this project was to develop and demonstrate a novel two-stage multi-beam klystron (TS-MBK) for use in accelerator, medical, national security, medical, and environmental cleanup applications. The novelties embodied in the TS-MBK design include use of hollow beams to obtain strong coupling to cavities, and post acceleration after bunching to reduce the beam’s energy spread to allow an exceptional electronic efficiency that we predict can reach 90%. During Phase I of this project, Omega-P R&D refined its conceptual design of the 1.0 GHz TS-MBK, and collector design and cooling requirements for several levels of average power output. If, as was the case, it turned out that estimated costs for fabrication and testing of a full 12-beam TS-MBK prototype would exceed available Phase II funding, our Plan-B would have be adopted. In it, a single-beam version would have been designed and built, with all specifications identical to the 12-beam version, except that the average power level would be reduced by a factor of about 12. This one-beam version would still allow evaluation of the efficacy of our design concept for implementing two stages, including prevention of radiation loss at the HV gap, and for demonstrating the predicted 90% electronic efficiency and the absence of reflected electrons from the collector reaching the cathodes. But the absence of the expected industrial partner in further development of this novel RF source made it impractical for advancing the project into Phase II.

43 PARTICLE ACCELERATORS↗

Component Identification of Solid Biomass Fuels Using Reflected Light Microscopy: Interlaboratory Study 2

As nations transition toward sustainable energy systems, biomass has become a vital component of global energy portfolios. Derived from organic materials such as wood, agricultural residues, forestry byproducts, and organic waste, biomass is a renewable energy source with significant environmental and economic benefits. Responsible biomass energy production can improve waste management, reduce emissions of greenhouse gases, and mitigate environmental pollution. However, as the diversity of biomass-derived fuels increases, robust quality assessment methods are essential to ensure their efficiency, safety, and minimal environmental impact. Reflected light microscopy (RLM) is one such technique with the potential to complement conventional physico-chemical analyses by enabling a rapid identification of material constituents and impurities. To refine this methodology and evaluate the reproducibility of solid biomass component identification using RLM, an interlaboratory study (ILS) was conducted. The study involved the recognition of 58 components across 45 photomicrographs, with the participation of 65 scientists and students from 25 countries. The participants faced high difficulty identifying some of the marked components, and as a result, the percentage of correct answers ranged from 19.0 % to 98.3 %, with an average correct identification rate of 62.7 %. The most challenging aspects of the identification process included distinguishing between woody and non-woody (agro) biomass, accurately identifying petroleum-derived materials, and differentiating agro biomass from inorganic matter. The results suggest that while RLM is an important tool for characterizing solid biomass, further development of methodology guidelines and training are necessary to enhance its effectiveness. Future research should prioritize preparing detailed, image-rich, microscopic morphological descriptions of biomass fuel components, which could improve the accuracy and reliability of using RLM in biomass fuel characterization.

09 BIOMASS FUELS↗

Empirical thermophotovoltaic performance predictions and limits

Significant progress has been made in the field of thermophotovoltaics, with efficiency recently rising to over 40% due to improvements in cell design and material quality, higher emitter temperatures, and better spectral management. However, inconsistencies in trends for efficiency with semiconductor bandgap energy across various temperatures pose challenges in predicting optimal bandgaps or expected performance for different applications. To address these issues, here we present realistic performance predictions for various types of single-junction cells over a broad range of emitter temperatures using an empirical model based on past cell measurements. Our model is validated using data from different authors with various bandgaps and emitter temperatures, and an excellent agreement is seen between the model and the experimental data. Using our model, we show that in addition to spectral losses, it is important to consider practical electrical losses associated with series resistance and cell quality to avoid overestimation of system efficiency. Here, we also show the effect of modifying various system parameters such as bandgap, above and below-bandgap reflectance, saturation current, and series resistance on the efficiency and power density of thermophotovoltaics at different temperatures. Finally, we predict the bandgap energies for best performance over a range of emitter temperatures for different cell material qualities.

14 SOLAR ENERGY↗

Absorbing boundary conditions in material point method adopting perfectly matched layer theory

This study focuses on solving the numerical challenges of imposing absorbing boundary conditions for dynamic simulations in the material point method (MPM). To attenuate elastic waves leaving the computational domain, the current work integrates the Perfectly Matched Layer (PML) theory into the implicit MPM framework. The proposed approach introduces absorbing particles surrounding the computational domain that efficiently absorb outgoing waves and reduce reflections, allowing for accurate modeling of wave propagation and its further impact on geotechnical slope stability analysis. The study also includes several benchmark tests to validate the effectiveness of the proposed method, such as several types of impulse loading and symmetric and asymmetric base shaking. The conducted numerical tests also demonstrate the ability to handle large deformation problems, including the failure of elasto-plastic soils under gravity and dynamic excitations. The findings extend the capability of MPM in simulating continuous analysis of earthquake-induced landslides, from shaking to failure.

58 GEOSCIENCES↗

Etching-Chemistry-Driven Ruthenium Doping on Ti 3 C 2 T x MXene for Optimizing Electrochemical Performance

We demonstrate that the etching chemistry used during MXene synthesis from Ti 3 AlC 2 MAX phase significantly influences surface functionalization and structural vacancies, which in turn affect ruthenium (Ru) ion interactions. Using hydrofluoric acid (HF) and ammonium bifluoride (NH 4 HF 2 ) as etchants, we obtained MXene surfaces with distinct functional groups and Ti vacancies that impact Ru ion interactions and electrochemical performance. Both MXene variants (labeled MX(H) and MX(N), respectively) exhibited negative zeta potentials in their pristine state, but upon the addition of Ru the zeta potential for MX(H) reached 12.9 mV while that for MX(N) remained negative at −6.4 mV. This adsorption resulted in a 14.4-fold increase in the specific capacitance of MX(H)/Ru compared to pristine MX(H), whereas MX(N)/Ru exhibited only a 4.4-fold increase over its pristine counterpart. X-ray diffraction analysis identified the formation of ammonium titanium oxide fluoride, (NH 4 ) 3 TiOF 5 , on MX(N), which likely contributed to its reduced Ru adsorption. X-ray photoelectron spectroscopy suggested the presence of Ti vacancies in both MXene variants; however, their behavior toward Ru accommodation differed markedly, with MX(H) showing the most obvious shift in the Ti 2p peak in the XPS survey spectrum, while MX(N) showed the most obvious shift in the C 1s peak. Electron paramagnetic resonance spectroscopy further demonstrated a distinct alteration in the spectral signatures of MX(H) upon Ru addition, in contrast to the negligible changes in MX(N), indicating effective passivation of the Ti defect sites in MX(H) via vacancy-assisted Ru doping. Cyclic voltammetry showed that Ru-incorporated MX(H) nanocomposites exhibit more efficient redox-active sites, as reflected in their higher capacitance values. These findings highlight the pivotal role of MXene surface chemistry in controlling cation adsorption, providing valuable insights for the rational design of high-performance electrodes.

2D surface engineering↗

Theoretical foundations of waste factor and waste figure with applications to fixed wireless access and relay systems

The growing energy demands of next-generation wireless systems call for unified, system-level metrics to evaluate and optimize energy efficiency. This paper advances the concept of the Waste Factor (W), or Waste Figure (WF) in decibel scale, as a general framework for modeling power loss across cascaded communication components. By integrating W into the Consumption Factor (CF)–the ratio of data rate to consumed power–we reveal how component inefficiencies influence the minimum achievable energy per bit. Closed-form expressions are derived for energy-per-bit consumption in both direct and relay-assisted links, along with a decision rule for selecting the more energy-efficient path. While not explicitly modeled, Reflective Intelligent Surfaces (RIS) are shown to fit naturally within this framework. The analysis is further applied to a Fixed Wireless Access (FWA) scenario, where asymmetries in traffic direction and hardware inefficiencies are jointly considered, demonstrating the utility of the Waste Factor in guiding energy-aware system design.

Sevim, Nurullah [Texas A&M University, College Sta↗