SYS645 Design for Reliability Maintainability and Supportability: H12 Universal Cartridge Carrier (circa 1952)

The initial product specification' for the H12 Universal Cartridge Carrier (UUC) was released in October 1952 and is the twelfth piece of H-Gear (sequentially numbered) ever developed. It is the oldest piece of H-Gear currently in use. To gain perspective on the number of H-Gear since designed, the most currently developed and deployed H-Gear is the H1768, Inspection Stand. The UUC, (commonly referred to as just the "H12") has since been renamed to the H12 Adjustable Hand Truck. It was developed to support various maintenance operations for ordnance assembly and disassembly. This paper will provide evidence (where available) for the H12s current state of reliability, maintainability, and sustainability (RMA). Where documented evidence is not available, conclusions will be drawn based on its continued effective use over the past 67-years of service.

42 ENGINEERING↗

Reliability and Maintainability Changing the Culture

The Reliability and Maintainability team strives to ensure the reliability, availability, and maintainability of plant assets throughout their life cycle. This objective is accomplished by providing world-class maintenance engineering support and maintenance processes. University of Tennessee’s Reliability and Maintainability Center (UT RMC) Partnership – Provided subject matter expert (SME) analysis of current state of both sites integrated work control (IWC) and maintenance execution processes.

47 OTHER INSTRUMENTATION↗

Explained: Maintaining a Reliable Future Grid with More Wind and Solar

Since the early 2000s, maintaining grid reliability has become more complex due to a variety of factors, including the changing generation mix, the creation of wholesale energy markets, and a growing number of extreme weather events. Parts of the U.S. grid are already operating with significant amounts of wind and solar generation - with 2022 annual wind and solar generation in the range of 25% to 40%. Even without considering the effects of extreme weather, maintaining reliability will require new capacity to address both growth in electric demand and retiring capacity. Based on the 2022 North American Electric Reliability Corporation (NERC) Long-Term Reliability Assessment, the combination of both growth in peak demand and retirements suggests a need for more than 100 gigawatts (GW) of new capacity by 2032. In general, there are a five categories of resources that are expected to be deployed and used to meet the challenge of maintaining an adequate source of supply in the coming decades: new wind and solar resources (accounting for their reliability contributions), energy storage, demand response resources, expanded transmission, and continued use of thermal generators.

power grid↗

Reliability and Maintainability Data for Lead Lithium Cooling Systems

This article presents component failure rate data for use in assessment of lead lithium cooling systems. Best estimate data applicable to this liquid metal coolant is presented. Repair times for similar components are also referenced in this work. These data support probabilistic safety assessment and reliability, availability, maintainability and inspectability analyses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using Synchrophasors to Improve Bulk Power System Reliability in North America

Maintaining reliable operation of the bulk power system is a fundamental aspect of grid operation, and focuses on ensuring the system can withstand sudden disturbances or unanticipated failures of system elements such that instability, uncontrolled separation, or cascading failures will not occur. Phasor measurement units (PMUs) provide the capability for enhanced real-time monitoring and control room solutions as well as improved power system analysis in the planning horizon. With over 1,700 PMUs deployed in the North American grid, numerous PMU-based applications have been developed. This paper summarizes synchrophasor-based applications and presents utility synchrophasor experience.

PMU, oscillation monitoring, Power Plant Model Val↗

Explained: Fundamentals of Power Grid Reliability and Clean Electricity

Maintaining reliability of the bulk power system, which supplies and transmits electricity, is a critical priority for electric grid planners, operators, and regulators. As we move toward a cleaner electricity system with more technologies like wind, solar, and battery storage, the way in which we plan for and achieve reliability will change. This fact sheet provides additional technical background to the topics covered in three other reliability explainers on how we measure, enforce, and plan for reliable systems with more clean electricity.

POWER TRANSMISSION AND DISTRIBUTION↗

An economic assessment of behind-the-meter photovoltaics paired with batteries on the Hawaiian Islands.

Due to natural variability and uncertainty, the ever-increasing penetration of solar generation in Hawaii presents challenges to power grid operators to maintain reliable system operation. Demand response (DR) has the potential to be a cost-effective tool for Hawaii to reach its aggressive renewable energy goals while maintaining the reliability of power grids. The Hawaii Public Utilities Commission has approved the Hawaiian Electric Company's revised portfolio of DR programs. The companies have released a grid services purchase agreement and subscribed an initial tranche of load into their DR programs. This paper presents innovative analytical methods and comprehensive economic assessment for distributed photovoltaics (PV) paired with battery energy storage systems (BESSs) for two new DR programs, including fast frequency response and capacity grid service. Optimal dispatch and sizing methods are proposed for the paired system considering different tariff schedules and PV compensation programs across five islands. It was found that while the best resource configuration and potential economic benefits vary with tariff structure, a BESS paired with PV can be optimally dispatched to generate multiple value streams simultaneously. Compensation from DR programs is an important value stream to help increase the cost-effectiveness of the integrated system.

Battery energy storage system↗

Cloud-based Testbed for Adaptive Under-Frequency Load Shedding with High DER Penetration

Increasing penetration of distributed energy resources and behind-the-meter renewables may soon disrupt the efficacy of critical protection schemes, such as under-frequency load shedding (UFLS). Improved data exchange and coordination across the transmission-distribution boundary will be required to maintain reliability of bulk electric system. Standards-based data integration platforms using agreed-upon semantic vocabularies, such as the Common Information Model, will be key to enabling adaptive protection schemes requiring synthesized data from both the bulk power system and behind-the-meter resources. This paper introduces a cloud-based open-source data integration environment and UFLS clustering algorithm being developed to enable adaptive relay coordination between transmission and distribution utilities in the state of Vermont.

Anderson, Alexander A.↗

Evaluating penalized logistic regression models to predict Heat-Related Electric grid stress days

Understanding the conditions associated with stress on the electricity grid is important in the development of contingency plans for maintaining reliability during periods when the grid is stressed. In this paper, heat-related grid stress and the relationship with weather conditions is examined using data from the eastern United States. Penalized logistic regression models were developed and applied to predict stress on the electric grid using weather data. The inclusion of other weather variables, such as precipitation, in addition to temperature improved model performance. Several candidate models and datasets were examined. A penalized logistic regression model fit at the operation-zone level was found to provide predictive value and interpretability. Additionally, the importance of different weather variables observed at different time scales were examined. Maximum temperature and precipitation were identified as important across all zones while the importance of other weather variables was zone specific. The methods presented in this work are extensible to other regions and can be used to aid in planning and development of the electrical grid.

Bramer, L. M.↗

Maintaining Grid Reliability: Lessons From Renewable Integration Studies

The U.S. Department of Energy (DOE) and other organizations have sponsored numerous research studies over the last two decades to examine the effect of increased wind and solar deployment on grid reliability, including a number of studies that examine grids deriving more than 50% of annual energy from wind and solar. In this report, we discuss key findings from both the research body of knowledge and real-world practice related to grid reliability, and we demonstrate how to plan for and achieve continued reliability in the future as wind and solar deployment increase.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Explained: Reliability of the Current Power Grid

Maintaining reliability of the bulk power system, which supplies and transmits electricity, is a constant focus of electric grid planners, operators, and regulators. Based on the standards set by power system reliability entities, the U.S. grid has been and continues to be very reliable. Over the past decade the average U.S. customer has only experienced about 15 minutes of outages per year due to supply limitations, with most of those outages occurring due to failures on the distribution system. However, there have been a few notable incidents in recent years tied to extreme weather events. The fact sheet provides and introduction to reliability of the bulk power system in the U.S.

power grid↗

A Hot‐Swappable, Fault‐Tolerant, Modular Power Converter System for Solar Photovoltaic Plants

The performance metrics of the state-of-the-art commercial solar inverters, such as system cost, operation and maintenance (O&M) cost, service life, reliability, maintainability, and power density are much lower than the target metrics needed to achieve SunShot’s 2030 levelized cost of energy (LCOE) goals. To overcome the shortcomings of the existing solar inverters, this project proposed a novel Hot-Swappable, Fault-Tolerant, Modular Power Converter (HSFT-MPC) concept for solar photovoltaic (PV) plants and proved the concept through the design, fabrication, and laboratory test validation of a single-phase HSFT-MPC prototype. The HSFT-MPC has the following distinct advantages over the state-of-the-art: 1) elimination of harmonic/ electromagnetic interference (EMI) filter in the inverter stage due to the novel topology, 2) lower system cost and higher power density due to the modular design, elimination of harmonic/EMI filter, and lower cooling requirement, 3) higher efficiency due to lower switching frequencies, 4) higher reliability and longer (50 years) service life due to simpler cooling and fault tolerance capability, 5) easier installation, lower O&M cost, and improved maintainability due to the modular design and hot-swappable power electronic building blocks (PEBBs), and 6) improved manufacturability due to the modular design. This project developed a single-phase HSFT-MPC prototype with 25kW nominal output power, 2.4kV, 60Hz nominal AC output, lower than 5% AC output voltage total harmonic distortion, over 5 kW/L inverter power density, and 99.4% inverter peak efficiency, being tolerant to failure of single and multiple PEBBs, and capable of hot swapping of the failed PEBB(s). The HSFT-MPC enables uninterruptable operation of the solar PV plant when failure of single or multiple PEBBs or PV modules occurs. Compared with the existing solar inverters in the market, the HSFT-MPC is expected to reduce the inverter failure-caused downtime and energy losses of solar PV plants by more than 60% and 50%, respectively. Project findings have been presented at major conferences in the field and published in peer-reviewed papers, which added new knowledge to the field of power electronics for solar PV systems. A minicourse on Solar PV Systems was developed for outreach activities. The minicourse will help attract young individuals to the renewable energy profession which has a significant talent shortage. The HSFT-MPC is expected to overcome all of the shortcomings of the state-of-the-art solar inverters in terms of cost, efficiency, service life, reliability, maintainability, and manufacturability targets needed to achieve SunShot’s 2030 LCOE goals. Therefore, the proposed HSFT-MPC concept has the great potential to disrupt the current solar inverter market. This project created a pathway towards industry adoption of the HSFT-MPC to help achieve 50-year service life solar PV systems. Since the solar PV plants using the HSFT-MPC will feature with higher reliability, longer service life, and easier maintenance, they are particularly useful for the rural areas with underserved populations that demand reliable and affordable clean electricity. The outcomes of the project have the strong potential to address national needs in the field of renewable energy to reduce CO 2 emissions from the electricity sector, reduce imports of energy from foreign sources, and improve energy security, efficiency, and sustainability. Since electricity is used in almost all of society’s sectors, the outcomes of the project will benefit various sectors of society and economy.

14 SOLAR ENERGY↗

Cooperation in Transmission Expansion Planning: Enhancing Grid Reliability and Efficiency Under a Changing Climate

Electricity grids are challenged to maintain reliability during more intense and frequent extreme weather events due to climate change. This challenge is exacerbated by multi-sector electrification and power sector decarbonization through increased reliance on variable renewable energy, which necessitates the expansion of transmission infrastructure. However, transmission expansion planning is often complicated by intertwined planning authorities and jurisdictions, and allocation of large capital investment needs. These factors cause authorities to manage transmission investments individually (i.e., only/mostly intraregional planning), which can lead to suboptimal transmission networks. This study investigates the potential benefits of cooperative transmission expansion planning (i.e., both intraregional and interregional planning that optimizes transmission investments across the entire physical system). Using sectoral and economic optimization, and machine learning models, it analyzes the impact of different levels of cooperation among transmission planning regions within U.S. Western Interconnection in 2019 and 2059 via an iterative investment process. Furthermore, it examines the effects of future climate change on transmission cooperation by simulating historical heat waves from 2019 under conditions of 2059. The results indicate that cooperative transmission planning leads to lower wholesale electricity prices, decreased energy outages, and reduced greenhouse gas emissions. However, the advantages of collaboration diminish during widespread heat waves, despite remaining beneficial especially for regions like California Independent System Operator with substantial solar installations. The study underscores the importance of transmission cooperation in reducing costs and enhancing reliability, emphasizing the need for strategic investments in storage to address challenges posed by future extreme weather events with varying spatial scales.

Capacity Expansion Model↗

Inertia and the Power Grid: A Guide Without the Spin

This guide provides an overview of inertia’s role in the evolving power system. It describes the sources of inertia in the grid, the intrinsic interplay of inertia and other grid services, the factors that impact the amount of and need for inertia, and the changes that can be made to maintain reliability as it declines. The guide is intended for nontechnical audiences. And it introduces accessible examples to illustrate the concepts of inertia and other grid services that are required to maintain system frequency, which is a key indicator of health in the current grid. The guide also discusses alternatives to traditional inertia and provides several takeaways that may be informative to power system decision makers, planners, operators, analysts, and other stakeholders.

24 POWER TRANSMISSION AND DISTRIBUTION↗