Search NASA⌕ Search

SEARCH · Search NASA

Results for “Remedial Investigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Addendum to the East Tennessee Technology Park Site-Wide Residual Contamination Remedial Investigation Work Plan Oak Ridge, Tennessee

The East Tennessee Technology Park Site-Wide Residual Contamination Remedial Investigation Work Plan (DOE 2004) describes the planned fieldwork to support the remedial investigation (RI) for residual contamination at the East Tennessee Technology Park (ETTP) not addressed in previous Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) decisions. This Addendum describes activities that will be conducted to gather additional information in Zone 1 of the ETTP for groundwater, surface water, and sediments. This Addendum has been developed from agreements reached in meetings held on June 23, 2010, August 25, 2010, October 13, 2010, November 13, 2010, December 1, 2010, and January 13, 2011, with representatives of the U. S. Department of Energy (DOE), U. S. Environmental Protection Agency (EPA), and Tennessee Department of Environment and Conservation (TDEC). Based on historical to recent groundwater data for ETTP and the previously completed Sitewide Remedial Investigation for the ETTP (DOE 2007a), the following six areas of concern have been identified that exhibit groundwater contamination downgradient of these areas above state of Tennessee and EPA drinking water maximum contaminant levels (MCLs): (1) K-720 Fly Ash Pile, (2) K-770 Scrap Yard, (3) Duct Island, (4) K-1085 Firehouse Burn/J.A. Jones Maintenance Area, (5) Contractor's Spoil Area (CSA), and (6) Former K-1070-A Burial Ground. The paper presents a brief summary of the history of the areas, the general conceptual models for the observed groundwater contamination, and the data gaps identified.

54 ENVIRONMENTAL SCIENCES↗

Indoor Dust Remedial Investigation Sampling at the Colonie FUSRAP Site - 15578

The Colonie Formerly Utilized Sites Remedial Action Program (FUSRAP) Site is located in the Town of Colonie, Albany County, New York. The U.S. Army Corps of Engineers (USACE) is currently addressing environmental contamination associated with the Site. The area surrounding the Site consists of residential and commercial properties, known as vicinity properties. Cleanup activities have been completed on many of these VPs under the FUSRAP to address depleted uranium contamination. Soil remediation activities have been substantially completed at the Colonie FUSRAP Site and its VPs under the FUSRAP. Recent studies performed by an independent party and under FUSRAP identified uranium within indoor dust in residencies and businesses in the immediate vicinity of the Site. The studies were limited to non-living areas such as basement window sills, garages, and attics. This paper discusses the indoor dust Remedial Investigation (RI) for the VPs at the Colonie FUSRAP Site. The indoor dust sample media presented many technical challenges regarding sampling design, data reduction, and data interpretation. In addition, because the RI is focused on numerous resident-owned, rental, and commercial properties, challenges where presented regarding right-of-entry to sample and concerns were raised regarding confidentiality of the results. In response to this, a community outreach communication and education program is being developed to mitigate property-owner concerns. The paper also identifies specific action levels used to determine future actions. Ultimately, property-specific risk assessments, performed at properties exceeding the action levels, will be used to determine whether a response action is appropriate under FUSRAP. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Field Summary Report for Remedial Investigation of Hanford Site Releases to the Columbia River, Hanford Site, Washington, Collection of Surface Water, River Sediments, and Island Soils

This report has been prepared in support of the remedial investigation of Hanford Site Releases to the Columbia River and describes the 2008/2009 data collection efforts. This report documents field activities associated with collection of sediment, river water, and soil in and adjacent to the Columbia River near the Hanford Site and in nearby tributaries.

54 ENVIRONMENTAL SCIENCES↗

Field Summary Report for Remedial Investigation of Hanford Site Releases to the Columbia River, Hanford Site, Washington

This report summarizes field sampling activities conducted in support of WCH’s Remedial Investigation of Hanford Site Releases to the Columbia River. This work was conducted form 2008 through 2010. The work included preliminary mapping and measurement of Hanford Site contaminants in sediment, pore water, and surface water located in areas where groundwater upwelling were found.

54 ENVIRONMENTAL SCIENCES↗

Field Summary Report for Remedial Investigation of Hanford Site Releases to the Coumbia River, Hanford Site, Washington

This report summarizes field sampling activities conducted in support of WCH’s Remedial Investigation of Hanford Site Releases to the Columbia River. This work was conducted form 2008 through 2010. The work included preliminary mapping and measurement of Hanford Site contaminants in sediment, pore water, and surface water located in areas where groundwater upwelling were found.

54 ENVIRONMENTAL SCIENCES↗

Remedial Investigation of Hanford Site Releases to the Columbia River - 13603

In south-central Washington State, the Columbia River flows through the U.S. Department of Energy Hanford Site. A primary objective of the Hanford Site cleanup mission is protection of the Columbia River, through remediation of contaminated soil and groundwater that resulted from its weapons production mission. Within the Columbia River system, surface water, sediment, and biota samples related to potential Hanford Site hazardous substance releases have been collected since the start of Hanford operations. The impacts from release of Hanford Site radioactive substances to the Columbia River in areas upstream, within, and downstream of the Hanford Site boundary have been previously investigated as mandated by the U.S. Department of Energy requirements under the Atomic Energy Act. The Remedial Investigation Work Plan for Hanford Site Releases to the Columbia River [1] was issued in 2008 to initiate assessment of the impacts under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 [2]. The work plan established a phased approach to characterize contaminants, assess current risks, and determine whether or not there is a need for any cleanup actions. Field investigation activities over a 120-mile stretch of the Columbia River began in October 2008 and were completed in 2010. Sampled media included surface water, pore water, surface and core sediment, island soil, and fish (carp, walleye, whitefish, sucker, small-mouth bass, and sturgeon). Information and sample results from the field investigation were used to characterize current conditions within the Columbia River and assess whether current conditions posed a risk to ecological or human receptors that would merit additional study or response actions under CERCLA. The human health and ecological risk assessments are documented in reports that were published in 2012 [3, 4]. Conclusions from the risk assessment reports are being summarized and integrated with remedial investigation/feasibility study (RI/FS) reports developed for upland areas, riparian areas, and groundwater in the Hanford Site River Corridor. The RI/FS reports will evaluate the impacts to soil, groundwater, and river sediments and lead to proposed cleanup actions and records of decision to address releases from the Hanford Site reactor operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data Summary Report for the Remedial Investigation of Hanford Site Releases to the Columbia River, Hanford Site, Washington

This data summary report summarizes the investigation results to evaluate the nature and distribution of Hanford Site-related contaminants present in the Columbia River. As detailed in DOE/RL-2008-11, more than 2,000 environmental samples were collected from the Columbia River between 2008 and 2010. These samples consisted of island soil, sediment, surface water, groundwater upwelling (pore water, surface water, and sediment), and fish tissue.

54 ENVIRONMENTAL SCIENCES↗

Radiological data consolidation and 3D modeling of a building - 15473

A portion of a building at an industrial facility that conducted monazite sands-processing operations in the 1950's under contract to the Atomic Energy Commission (AEC) became contaminated. Subsequently the U.S. Department of Energy designated the facility for remedial action under the Formerly Used Sites Remedial Action Program (FUSRAP). Remedial investigation, remedial actions and post-remediation surveys have been conducted in portions of the building. Radiological data for the interior of the building were compiled, evaluated and presented in a three dimensional (3-D) model (the model) created by AMEC Foster Wheeler in order to identify areas that meet the Record of Decision (ROD) cleanup criteria, and identity areas that may require remedial action or may require additional investigation due to data gaps. The data from different phases of investigation and remediation cover different portions of the building and in some cases overlap. In addition, the data were collected over a period of more than ten years, for different objectives, and thus the instruments and methods for establishing efficiency were not necessarily consistent. The data consolidation process included determining the relative quality of data points to include in the model and the development of rationale associated with assigning a quality level (i.e. ranking) to each data point. The rationale for ranking data quality included, as the primary determining factors, chronological order of the data (most recent was ranked as more reliable), certainty of the sample locations within the building, and analytical data quality. A 3-D model of the building was created using a laser point cloud scan which was then converted into a 3-D design model. Sample locations were then entered into the model and linked with the analytical database to allow display of the radiological results in the model. The visual model allows both strategic and tactical decisions to be made, depending on the level of detail examined. The evaluation process allowed maximum use of the historical data set, rather than requiring older data to be disregarded, and provided at a minimum a qualitative sense of data quality/confidence in the data. The (authors)process also highlights the importance of collecting high quality data from the very beginning with a consistent locational coordinate system, and the need for a good visualization model in order to assess contaminant locations during remedial action or post-remediation surveys.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A system to investigate the remediation of organic vapors using microwave-induced plasma with fluidized carbon granules

This article describes a system to investigate the parameters for the remediation of organic vapors using microwave-induced plasma on fluidized carbon granules. The system is based on a single mode microwave apparatus with a variable power (2.45 GHz) generator. Carbon granules are fluidized in a silica tube situated in the sample section of a waveguide incorporating two additional ports to allow plasma intensity monitoring using a light sensor and imaging with a digital camera. A fluoroptic probe is used for in situ measurement of the carbon granule temperature, while the effluent gas temperature is measured with a thermocouple situated in the silica tube outside the cavity. Data acquisition and control software allow experiments using a variety of microwave power regimes while simultaneously recording the light intensity of any plasma generated within the carbon bed, together with its temperature. Evaluation using two different granular activated carbons and ethyl acetate, introduced as a vapor into the fluidizing air stream at a concentration of 1 ppm, yielded results which indicated that significant destruction of ethyl acetate, as monitored using a mass spectrometer, was achieved only with the carbon granules showing high plasma activity under pulsed microwave conditions. The system is therefore suitable for comparison of the relative microwave activities of various activated carbon granules and their performance in microwave remediation and regeneration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Challenges Of Investigating And Remediating Port Hope's Small-Scale Urban Properties - 13115

An important component of the Port Hope Project, the larger of the two projects comprising the Port Hope Area Initiative (PHAI), is the investigation of all 4,800 properties in the Municipality of Port Hope for low level radioactive waste (LLRW) and the remediation of approximately 10% of these. Although the majority of the individual properties are not expected to involve technically sophisticated remediation programs, the large number of property owners and individually unique properties are expected to present significant logistic challenges that will require a high degree of planning, organization and communication. The protocol and lessons learned described will be of interest to those considering similar programs. Information presented herein is part of a series of papers presented by the PHAI Management Office (PHAI MO) at WM Symposium '13 describing the history of the Port Hope Project and current project status. Other papers prepared for WM Symposium '13 address the large-scale site cleanup and the construction of the long-term waste management facility (LTWMF) where all of the LLRW will be consolidated and managed within an engineered, above-ground mound. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advances in Geophysical Monitoring Methods To Support Groundwater Remedies

Monitoring plays an important role in supporting remedial investigations and selection of remedies for groundwater contamination and for assessing performance during implementation of remedies. When a groundwater plume is near the interface between groundwater and surface water, the dynamics of groundwater flow at this interface needs to be considered in the design and implementation of a remedy. For this and other aquifer situations, groundwater flow dynamics may be difficult to evaluate through groundwater head measurements due to a sparse monitoring-well network, a relatively flat hydraulic gradient, or the presence of induced gradients from pumping operations or groundwater mounds. Geophysical approaches, coupled with other targeted measurements or the use of an ionic tracer, provide temporal data that can quantify groundwater flow dynamics. Recent developments include a flux-monitoring tool that measures fluid conductivity, bulk conductivity, and temperature at the interface between groundwater and surface water. Joint interpretation of these local data with temporal two- or three-dimensional geophysical data improves quantification of groundwater and mass flux at a targeted location. In addition, geophysical design improvements that enable the use of numerical simulations to evaluate implementation configurations and expected data resolution for geophysical methods identify threshold conditions for successful monitoring and identify the most cost-effective configurations to meet monitoring objectives.

Strickland, Christopher E.↗

Emerging Contaminants: Investigation and Remediation of Poly- and Perfluoroalkyl Substances in the Environment - 17339

The group of chemicals known as PFAS (poly- and perfluoroalkyl substances) has come under increasing scientific and regulatory scrutiny in recent years as more is understood about their toxicity, their environmental persistence and their potential to bio-accumulate. PFAS are used in a wide range of industrial applications and commercial products due to their unique surface tension and levelling properties. They include stain repellents for textiles and carpeting, grease-proof paper, water- and oil-resistant coatings, and mist suppressants. PFAS are also major components of the class B fire fighting foams known as aqueous film forming foam (AFFF), Fluoro-protein Foams (FP) and Film Forming Fluoro-protein Foams (FFFP) commonly used at Federal and Commercial facilities throughout the world. Long chain PFASs (>5 or 6perfluroalkyl-carbons) such perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS), bio-accumulate. Currently, PFOS, PFOA, and a few other PFASs are increasingly regulated outside of the U.S., and at varying levels in drinking water or groundwater in select U.S. states. The U.S. EPA recently established a long-term exposure criteria of 70 ng/L for combined PFOS and PFOA in drinking water. While PFOS and PFOA have the most regulatory attention, there are thousands of chemicals in the PFAS class; some PFASs are precursor compounds capable of transforming to PFOS and PFOA or analogs. The remedial options available to address PFAS contamination are limited by the unique physico-chemical properties of these compounds. Technologies currently used for the remediation of PFAS contaminated sites include soil incineration or excavation to landfill, and groundwater extraction with PFAS adsorption onto activated carbon or resins. Emerging technologies for PFAS, include stabilization in soil, photolysis/ photo-catalysis, reductive decomposition, advanced oxidation, reduction and sonolysis for groundwater. However, the evidence that these technologies effectively break the fully fluorinated backbone of PFAS, or can treat or sequester all carbon chain lengths is limited. To date these technologies are unproven or considered infeasible for high flowrate, low concentration applications. New in-situ techniques, including an oxidation / reduction method known as ScisoR{sup R} (Smart combined in situ oxidation and Reduction), are currently being tested in the lab and some are being applied in field demonstrations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advances in Geophysical Monitoring Methods to Support Groundwater Remedies - 19096

Monitoring plays an important role in supporting remedial investigations and selection of remedies for groundwater contamination and for assessing performance during implementation of remedies. When a groundwater plume is near the interface between groundwater and surface water, the dynamics of groundwater flow at this interface needs to be considered in the design and implementation of a remedy. For this and other aquifer situations, groundwater flow dynamics may be difficult to evaluate through groundwater head measurements due to a sparse monitoring-well network, a relatively flat hydraulic gradient, or the presence of induced gradients from pumping operations or groundwater mounds. Geophysical approaches, coupled with other targeted measurements or the use of an ionic tracer, provide temporal data that can quantify groundwater flow dynamics. Recent developments include a flux-monitoring tool that measures fluid conductivity, bulk conductivity, and temperature at the interface between groundwater and surface water. Joint interpretation of these local data with temporal two- or three-dimensional geophysical data improves quantification of groundwater and mass flux at a targeted location. In addition, geophysical design improvements that enable the use of numerical simulations to evaluate implementation configurations and expected data resolution for geophysical methods identify threshold conditions for successful monitoring and identify the most cost-effective configurations to meet monitoring objectives. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Complex Sources and Impacts on Remediation and Monitoring Approaches

Remedy selection, implementation, and coordination with tank farm activities for adjacent waste sites need to be facilitated by a technically defensible description of sources and their relative strength and temporal contributions to groundwater contamination. Detailed data describing contaminant source releases are typically not available, so source locations are highly uncertain. Furthermore, data on sources and model parameters are not readily available through direct measurements. Instead, source data are often derived by extrapolation from a few direct and/or indirect measurements, while model parameters are commonly estimated using inverse modeling or calibration methods. Because the conceptual model of sources will influence the mass and timing of the flux of contaminants to groundwater, uncertainty in the source terms should be considered. Even though a best-fit model can often be identified, it may not be the best representation of the sources given the sparse, uncertain nature of the data used for estimating source terms. To support future feasibility studies, a systematic approach is needed for identifying remediation and monitoring activities appropriate under conditions of uncertainty. In this study, an integrated assessment of alternative conceptual model elements has been examined using the B-Complex site in the Hanford Central Plateau to demonstrate how multiple sources in a waste management complex can be described to identify their relative contributions to groundwater. The heterogeneous structure of the system is modeled based on available field information on the lithological data for both the vadose zone and aquifer. The approach includes a simulation assessment and linkages to site data, with an uncertainty analysis applied to evaluate the effects of source term uncertainty on contaminant mass flux to groundwater. An integrated assessment of alternative conceptual model elements was evaluated to identify how parameter uncertainty impacts both temporal and spatial uncertainties associated with vadose zone source terms. Modeling scenarios identify important characteristics of remediation target zones to provide context for how surface barriers, in situ remedies, and water-table treatment zones can be designed to account for source dynamics. Ramifications for remediation and monitoring are discussed within the context of the source term uncertainty. The described approach facilitates systematically addressing alternative conceptual model questions in relation to remediation and monitoring and supports the remedial investigation/ feasibility study process and the remediation strategy development for the Hanford Central Plateau.

Rockhold, Mark L.↗