Search NASA⌕ Search

SEARCH · Search NASA

Results for “Repeated measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Remote measurement of salinity: Repeated measurements over a single flight line near the Mississippi Sound

Experiments to remotely determine sea water salinity from measurements of the sea surface radiometric temperature over the Mississippi Sound were conducted. The line was flown six times at an altitude of 244 meters. The radiometric temperature of the sea surface was measured in two spectral intervals. The specifications of the equipment and the conditions under which the tests were conducted are described. Results of the tests are presented in the form of graphs.

Thomann, G. C.↗

A Network-Based Algorithm for Clustering Multivariate Repeated Measures Data

The National Aeronautics and Space Administration (NASA) Astronaut Corps is a unique occupational cohort for which vast amounts of measures data have been collected repeatedly in research or operational studies pre-, in-, and post-flight, as well as during multiple clinical care visits. In exploratory analyses aimed at generating hypotheses regarding physiological changes associated with spaceflight exposure, such as impaired vision, it is of interest to identify anomalies and trends across these expansive datasets. Multivariate clustering algorithms for repeated measures data may help parse the data to identify homogeneous groups of astronauts that have higher risks for a particular physiological change. However, available clustering methods may not be able to accommodate the complex data structures found in NASA data, since the methods often rely on strict model assumptions, require equally-spaced and balanced assessment times, cannot accommodate missing data or differing time scales across variables, and cannot process continuous and discrete data simultaneously. To fill this gap, we propose a network-based, multivariate clustering algorithm for repeated measures data that can be tailored to fit various research settings. Using simulated data, we demonstrate how our method can be used to identify patterns in complex data structures found in practice.

Koslovsky, Matthew↗

Preliminary evaluation of a micro-based repeated measures testing system

A need exists for an automated performance test system to study the effects of various treatments which are of interest to the aerospace medical community, i.e., the effects of drugs and environmental stress. The ethics and pragmatics of such assessment demand that repeated measures in small groups of subjects be the customary research paradigm. Test stability, reliability-efficiency and factor structure take on extreme significance; in a program of study by the U.S. Navy, 80 percent of 150 tests failed to meet minimum metric requirements. The best is being programmed on a portable microprocessor and administered along with tests in their original formats in order to examine their metric properties in the computerized mode. Twenty subjects have been tested over four replications on a 6.0 minute computerized battery (six tests) and which compared with five paper and pencil marker tests. All tests achieved stability within the four test sessions, reliability-efficiencies were high (r greater than .707 for three minutes testing), and the computerized tests were largely comparable to the paper and pencil version from which they were derived. This computerized performance test system is portable, inexpensive and rugged.

Kennedy, Robert S.↗

Microcomputer-based tests for repeated-measures: Metric properties and predictive validities

A menu of psychomotor and mental acuity tests were refined. Field applications of such a battery are, for example, a study of the effects of toxic agents or exotic environments on performance readiness, or the determination of fitness for duty. The key requirement of these tasks is that they be suitable for repeated-measures applications, and so questions of stability and reliability are a continuing, central focus of this work. After the initial (practice) session, seven replications of 14 microcomputer-based performance tests (32 measures) were completed by 37 subjects. Each test in the battery had previously been shown to stabilize in less than five 90-second administrations and to possess retest reliabilities greater than r = 0.707 for three minutes of testing. However, all the tests had never been administered together as a battery and they had never been self-administered. In order to provide predictive validity for intelligence measurement, the Wechsler Adult Intelligence Scale-Revised and the Wonderlic Personnel Test were obtained on the same subjects.

Kennedy, Robert S.↗

Development of microcomputer-based mental acuity tests for repeated-measures studies

The purpose of this report is to detail the development of the Automated Performance Test System (APTS), a computer battery of mental acuity tests that can be used to assess human performance in the presence of toxic elements and environmental stressors. There were four objectives in the development of APTS. First, the technical requirements for developing APTS followed the tenets of the classical theory of mental tests which requires that tests meet set criteria like stability and reliability (the lack of which constitutes insensitivity). To be employed in the study of the exotic conditions of protracted space flight, a battery with multiple parallel forms is required. The second criteria was for the battery to have factorial multidimensionality and the third was for the battery to be sensitive to factors known to compromise performance. A fourth objective was for the tests to converge on the abilities entailed in mission specialist tasks. A series of studies is reported in which candidate APTS tests were subjected to an examination of their psychometric properties for repeated-measures testing. From this work, tests were selected that possessed the requisite metric properties of stability, reliability, and factor richness. In addition, studies are reported which demonstrate the predictive validity of the tests to holistic measures of intelligence.

Kennedy, R. S.↗

Positional repeatability measurements of stepper motors at cryogenic temperatures

For cryogenically-cooled infrared instruments and telescopes employed in space, reliable and predictable motor operations at 4 K in vacuum are in most cases necessary. For the Shuttle Infrared Telescope Facility (SIRTF), stepper motors may be employed in a number of applications. A test facility was designed and built for measuring stepper motor positional repeatability, in vacuum, over a temperature range from ambient to liquid helium temperature. Tests regarding positional repeatability were conducted at different motor speeds, directions of motor rotation, step sizes, and power conditions. In addition, tests were performed with respect to the ability of the motor to remain in a position with no power applied to the motor.

Pompea, S. M.↗

Repeated-Measures Analysis of Image Data

It is suggested that using a modified analysis of variance procedure on data sampled systematically from a rectangular array of image data can provide a measure of homogeneity of means over that array in single directions and how variation in perpendicular directions interact. The modification of analysis of variance required to account for spatial correlation is described theoretically and numerically on simulated data.

Newton, H. J.↗

System and method for improving ultrasound image acquisition and replication for repeatable measurements of vascular structures

High resolution B-mode ultrasound images of the common carotid artery are obtained with an ultrasound transducer using a standardized methodology. Subjects are supine with the head counter-rotated 45 degrees using a head pillow. The jugular vein and carotid artery are located and positioned in a vertical stacked orientation. The transducer is rotated 90 degrees around the centerline of the transverse image of the stacked structure to obtain a longitudinal image while maintaining the vessels in a stacked position. A computerized methodology assists operators to accurately replicate images obtained over several spaced-apart examinations. The methodology utilizes a split-screen display in which the arterial ultrasound image from an earlier examination is displayed on one side of the screen while a real-time live ultrasound image from a current examination is displayed next to the earlier image on the opposite side of the screen. By viewing both images, whether simultaneously or alternately, while manually adjusting the ultrasound transducer, an operator is able to bring into view the real-time image that best matches a selected image from the earlier ultrasound examination. Utilizing this methodology, measurement of vascular dimensions such as carotid arterial IMT and diameter, the coefficient of variation is substantially reduced to values approximating from about 1.0% to about 1.25%. All images contain anatomical landmarks for reproducing probe angulation, including visualization of the carotid bulb, stacking of the jugular vein above the carotid artery, and initial instrumentation settings, used at a baseline measurement are maintained during all follow-up examinations.

Selzer, Robert H.↗

Effects of Reduced Strength on Self-Selected Pacing for Long-Duration Activities

Strength and aerobic capacity are predictors of astronaut performance for extravehicular activities (EVA) during exploration missions. It is expected that astronauts will self‐select a pace below their ventilatory threshold (VT). PURPOSE: To determine the percentage of VT that subjects self‐select for prolonged occupational tasks. METHODS: Maximal aerobic capacity and a variety of lower‐body strength and power variables were assessed in 17 subjects who climbed 480 rungs on a ladder ergometer and then completed 10 km on a treadmill as quickly as possible using a self‐selected pace. The tasks were performed on 4 days, with a weighted suit providing 0% (suit fabric only), 40%, 60%, and 80% of additional bodyweight (BW), thereby altering the strength to BW ratio. Oxygen consumption and heart rate were continuously measured. Repeated measures ANOVA and post‐hoc comparisons were performed on the percent of VT values under each suited condition. RESULTS: Subjects consistently self‐paced at or below VT for both tasks and the pace was related to suit weight. At the midpoint for the ladder climb the 80% BW condition elicited the lowest metabolic cost (‐19+/-14% below VT), significantly different than the 0% BW (‐3+/-16%, P=0.002) and the 40% BW conditions (‐5+/-22%, P=0.023). The 60% BW condition (‐13+/-19%) was different than the 40% BW condition (P=0.034). Upon completion of the ladder task there were no differences among the conditions (0%BW: 3+/-18%; 40%BW: 3+/-21%; 60%BW: ‐ 8+/-25%; 80%BW: ‐10+/-18%). All subjects failed to complete 5km at 80%BW. At the midpoint of the treadmill test the three remaining conditions were all significantly different (0%BW: ‐20+/-15%; 40%BW: ‐ 33+/-15%; 60%BW: ‐41+/-19%). Upon completion of the treadmill test the 60% BW condition (‐38+/-12%) was significantly different than the 40% BW (‐28+/-15%, P=0.024). CONCLUSIONS: Decreasing relative strength results in progressive and disproportionate decreases (relative to VT) in self‐selected pacing during long‐duration activities. Thus, during prolonged, endurance‐type activities, large reductions in strength cause notable performance decrements despite no changes in aerobic capacity. These data highlight the importance of both aerobic capacity and muscle strength to the performance of prolonged EVA in exploration mission scenarios.

Buxton, Roxanne E.↗

Repeatable electrical measurement instrumentation for use in the accelerated stress testing of thin film solar cells

Attention is given to the construction, calibration, and performance of a repeatable measurement system for use in conjunction with the accelerated stress testing of a-Si:H cells. A filtered diode array is utilized to approximate the spectral response of any type of solar cell in discrete portions of the spectrum. It is noted that in order to achieve the necessary degree of overall repeatability, it is necessary to pay particular attention to methods of contacting and positioning the cells.

Davis, C. W.↗

Repeatability and measurement uncertainty of the United States meteorological rocketsonde

It is pointed out that rocketsondes provide the only in situ 'ground truth' data for altitudes above 30 km. The need for precise temperature information has, therefore, led to a study of rocketsonde instrument repeatability and measurement uncertainty. Results obtained from root-mean-square difference and linear regression techniques are consistent and strongly suggest that the Datasonde precision is better than 1 C up to an altitude of 53 or 54 km. This result excludes atmospheric variability, which may occur within 5 min, and effects owing to spatial differences, which are small for paired measurements. At altitudes of 55 km and higher it is possible that sensor and flight-related anomalies, differences in radiation corrections owing to differing solar angles because of varying launch times, or even seasonal variations may create conditions that affect the magnitude of the standard corrections.

Schmidlin, F. J.↗

Measuring Unique Contextual Factors: Group Living Skills

BACKGROUND The Human Factors and Behavioral Performance Exploration Measures (HFBP-EM) suite is a set of standardized measures used to assess behavioral health and performance risks related to future exploration-class space missions. During the HFBP-EM suite development, the importance of assessing unique contextual factors to understand the drivers of team dynamics was identified. Group living skills are a unique workplace skill which applies to those coworkers who live and work together. As mission lengths become longer, the line between work and non-work life may blur. Extreme living conditions such as spaceflight can result in increased stress over time, negatively impact mood and well-being, decrease team cohesion and increase conflict, deteriorate task performance, and potentially reduce mission success [1]. With no breaks in their isolated and confined environment possible, living with a messy, inconsiderate crewmember can add to the stress. Alternatively, crews with good group living skills may support one another, mitigating the negative effects of the extreme environment. There was no direct measure of group living skills. This work sought to fill this measurement gap and collect data related to group living in isolated, confined, extreme (ICE) environments. METHODS Group living skills as an astronaut competency area were developed with the input of experts familiar with ICE environments. Distinct aspects of this competency were reviewed and discussed by a NASA-invited group of spaceflight experts in 2015 to identify individual and team behavioral health and performance measures for operational environments. This work resulted in a 5-item measure focused on group living experiences with each crewmember (or the crew as a whole). A 6th item asks whether an individual would go on another mission with a particular crewmember or crew as a measure of future-oriented group living, or team viability. The measure was deployed in 24 teams living and working together in isolated and confined environments (e.g., International Space Station, space mission simulation analogs). RESULTS & DISCUSSION In this presentation, we will summarize results which indicate the Group Living Skills (GLS) Survey is a reliable, valid, and operationally feasible measure. Reliability was evaluated in several ways. Two-way multilevel mixed models revealed strong repeated measures reliability (ICC2 = .902, Omega between = .954). Reliability of change within teams was strong (Rc = .81). Factor analysis showed a consistent two-factor structure when individuals rated either the whole crew, all individuals, just peers, or a focal roommate. The latter used a sociometric approach to rating the GLS of the roommates. The two factors were tidiness and being considerate of others. We assessed the criterion-related validity of GLS, by examining GLS operationalized as the team-level aggregated GLS Survey scores as a predictor of team viability, team cohesion, and team performance. We used generalized mixed models to account for the repeated measures and longitudinal data. The marginal R2 change was used to determine the extent to which GLS were related to the team outcomes while controlling for mission day and campaign. Results suggested GLS was strongly related to team viability (marginal R2 change = .40), team cohesion (marginal R2 change = 0.28), social cohesion (marginal R2 change = 0.25), and moderately related to task cohesion (marginal R2 change = 0.18). GLS scores had a small relationship with team performance (marginal R2 change = .08). Results support GLS as a measure that can be used to capture group living skills of crews who live and work together in ICE. Because the items were written to be broadly applicable, less extreme environments with teams living and working together for some length of time also benefit from this measure (e.g., college roommates, camps). See Landon et al. (2024) for full results [2]. SUMMARY We report reliability and validity evidence for a new measure that assesses the Group Living Skills for teams that live and work in operational environments such as spaceflight.

J C W Miller↗

A menu of self-administered microcomputer-based neurotoxicology tests

This study examined the feasibility of repeated self-administration of a newly developed battery of mental acuity tests. Researchers developed this battery to be used to screen the fitness for duty of persons in at-risk occupations (astronauts, race car drivers), or those who may be exposed to environmental stress, toxic agents, or disease. The menu under study contained cognitive and motor tests implemented on a portable microcomputer including: a five-test core battery, lasting six minutes, which had demonstrable reliabilities and stability from several previous repeated-measures studies, and also 13 new tests, lasting 42 minutes, which had appeared in other batteries but had not yet been evaluated for repeated-measures implementation in this medium. Sixteen subjects self-administered the battery over 10 repeated sessions. The hardware performed well throughout the study and the tests appeared to be easily self-administered. Stabilities and reliabilities of the test from the core battery were comparable to those obtained previously under more controlled experimental conditions. Analyses of metric properties of the remaining 13 tests produced eight additional tests with satisfactory properties. Although the average retest reliability was high, cross-correlations between tests were low, indicating factorial richness. The menu can be used to form batteries of flexible total testing time which are likely to tap different mental processes and functions.

Kennedy, Robert S.↗

Comparison of Knee and Ankle Dynamometry between NASA's X1 Exoskeleton and Biodex System 4

Pre- and post-flight dynamometry is performed on International Space Station crewmembers to characterize microgravity-induced strength changes. Strength is not assessed in flight due to hardware limitations and there is poor understanding of the time course of in-flight changes. PURPOSE: To assess the reliability of a prototype dynamometer, the X1 Exoskeleton (EXO) and its agreement with a Biodex System 4 (BIO). METHODS: Eight subjects (4 M/4 F) completed 2 counterbalanced testing sessions of knee extension/flexion (KE/KF), 1 with BIO and 1 with EXO, with repeated measures within each session in normal gravity. Test-retest reliability (test 1 and 2) and device agreement (BIO vs. EXO) were evaluated. Later, to assess device agreement for ankle plantarflexion (PF), 10 subjects (4 M/6 F) completed 3 test conditions (BIO, EXO, and BIOEXO); BIOEXO was a hybrid condition comprised of the Biodex dynamometer motor and the X1 footplate and ankle frame. Ankle comparisons were: BIO vs. BIOEXO (footplate differences), BIOEXO vs. EXO (motor differences), and BIO vs. EXO (all differences). Reliability for KE/KF was determined by intraclass correlation (ICC). Device agreement was assessed with: 1) repeated measures ANOVA, 2) a measure of concordance (rho), and 3) average difference. RESULTS: ICCs for KE/KF were 0.99 for BIO and 0.96 to 0.99 for EXO. Agreement was high for KE (concordance: 0.86 to 0.95; average differences: -7 to +9 Nm) and low to moderate for KF (concordance: 0.64 to 0.78; average differences: -4 to -29 Nm, P<0.05). BIO vs. BIOEXO PF concordance ranged from 0.89 to 0.92 and mean differences ranged from -9 to +3 Nm (BIO < BIOEXO). BIOEXO vs. EXO PF concordance ranged from 0.73 to 0.80 while mean differences were -18 to -36 Nm (BIOEXO < EXO, P<0.05). PF concordance for BIO vs. EXO was slightly lower (0.61 to 0.84) and mean differences were greater (-27 to -33 Nm; BIO < EXO, P<0.05). CONCLUSION: BIO and EXO were similarly reliable for KE and KF. KE measures produced high agreement between devices; KF did not. For ankle PF, torque differences due to the two footplates were small. However, the X1 motor reports greater torques than the Biodex motor during PF. This first prototype provides proof of concept for a reliable, robotic-based exoskeleton to perform portable dynamometry for large muscle groups of the lower body.

English, K. L.↗