Synthesis and characterization of alkali aluminosilicate hydraulic cement that meets standard requirements for general use
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
The objective of this NREL report is to provide information on codes and standards (of two emerging hydrogen power fuel cell technology markets; forklift trucks and backup power units), that would ease the implementation of emerging fuel cell technologies. This information should help project developers, project engineers, code officials and other interested parties in developing and reviewingpermit applications for regulatory compliance.
Sandia National Laboratories is developing the technical basis for assessing the risk of hydro gen infrastructure for use in the development of relevant codes and standards. The development of codes and standards is an important step in ensuring the safe design and operation of the hydrogen fuel cell infrastructure. Codes and standards organizations are increasingly using risk-informed processes to establish code requirements.
Enhanced glass-to-metal feedthroughs will be used to carry key instrumentation and control (I and C) signals in China's high-temperature, gas-cooled pebble-bed modular reactor (HTR-PM) at Shidaowan, and in Small Modular Reactor (SMR) prototyping. Chinergy Co., Ltd and Jiamusi Electric Machine Co., Ltd will use the feedthroughs, also called electrical penetration assemblies (EPAs), at the Shidaowan twin-reactor high temperature reactor (HTR). These feedthroughs are manufactured using specialized processes that make them far more robust than counterparts made with organic or ceramic materials. Improved EPAs manufactured by SCHOTT are the only feedthrough solution that can be used in the primary loop of an HTR because organic seals cannot withstand the high temperatures and pressures of this environment. Glass-to-metal seals (GTMS) are made using inorganic, non-aging materials which enable a virtually unlimited lifespan in high-temperature, high-radiation and high-pressure applications. This I and C technology package is being enhanced by the development and testing of new mineral-insulated (MI) cable connectors and EPAs made of crystallized glass-ceramic combined with superalloys. The EPAs have a maintenance-free lifespan of over 60 years, preventing any outage time related to these components and subsequently reducing costs associated with shutdowns. They are far more robust than organic seals and provide increased safety at a lower lifetime cost. Resistance against high pressure and high temperature are especially ideal qualities that make EPAs a valuable choice for environments with high standards for fire protection, such as nuclear plants, subsea oil drilling, or any other underwater application. Due to their significant offering of safety-relevant qualities, the EPAs have also been chosen by BWXT for implementation in its mPower SMR. Small modular reactor requirements are complex and very challenging but are met by the new EPA components, which will help form a strong I and C safety chain. Unlike ordinary compression glass-to-metal seals, GTMS with crystallized glass-ceramic have the ability to withstand temperatures of over 350 deg. C / 662 deg. F and operating pressures of 3500 bar. Furthermore, their lifetime is qualified for up to 60 years, including pressure and radiation requirements in accordance with the latest IEC/IEEE standards. Higher-specification EPAs and MI cable connectors have been designed into severe accident I and C instruments, including advanced hydrogen and oxygen sensors that exceed the challenging requirements of both HTR and SMR applications. (authors)
V&V and UQ are the primary means to assess the accuracy and reliability of M&S and, hence, to establish confidence in M&S. Though other industries are establishing standards and requirements for the performance of V&V and UQ, at present, the nuclear industry has not established such standards or requirements. However, the nuclear industry is beginning to recognize that such standards are needed and that the resources needed to support V&V and UQ will be very significant. In fact, no single organization has sufficient resources or expertise required to organize, conduct and maintain a comprehensive V&V and UQ program. What is needed is a systematic and standardized approach to establish and provide V&V and UQ resources at a national or even international level, with a consortium of partners from government, academia and industry. Specifically, what is needed is a structured and cost-effective knowledge base that collects, evaluates and stores verification and validation data, and shows how it can be used to perform V&V and UQ, leveraging collaboration and sharing of resources to support existing engineering and licensing procedures as well as science-based V&V and UQ processes. The Nuclear Energy Knowledge base for Advanced Modeling and Simulation (NE-KAMS) is being developed at the Idaho National Laboratory in conjunction with Bettis Laboratory, Sandia National Laboratories, Argonne National Laboratory, Utah State University and others with the objective of establishing a comprehensive and web-accessible knowledge base to provide V&V and UQ resources for M&S for nuclear reactor design, analysis and licensing. The knowledge base will serve as an important resource for technical exchange and collaboration that will enable credible and reliable computational models and simulations for application to nuclear power. NE-KAMS will serve as a valuable resource for the nuclear industry, academia, the national laboratories, the U.S. Nuclear Regulatory Commission (NRC) and the public and will help ensure the safe, economical and reliable operation of existing and future nuclear reactors.
This document is intended to aid in the understanding and application of the New York State Standardized Interconnection Requirements (SIR) and Application Process for New Distributed Generators 5 MW or Less Connected in Parallel with Utility Distribution Systems, and it aims to provide supplemental information and discussion on selected topics relevant to the SIR. This guide focuses on technical issues that have to date resulted in the majority of utility findings within the context of interconnecting photovoltaic (PV) inverters. This guide provides background on the overall issue and related mitigation measures for selected topics, including substation backfeeding, anti-islanding and considerations for monitoring and controlling distributed energy resources (DER).
The International Electrotechnical Commission (IEC) is the leading and oldest global organization with over 100 years history of developing and publishing international standards for all electrical, electronic and related technologies, including radiation detection instrumentation. Subcommittee 45B 'Radiation Protection Instrumentation' of the IEC has recently started the development of two standards on radiation-generating devices. IEC 62463 'Radiation protection instrumentation--X-ray Systems for the Screening of Persons for Security and the Carrying of Illicit Items' is applicable to X-ray systems designed for screening people to detect if they are carrying objects such as weapons, explosives, chemical and biological agents and other concealed items that could be used for criminal purposes, e.g. terrorist use, drug smuggling, etc. IEC 62523 'Radiation protection instrumentation--Cargo/Vehicle radiographic inspection systems' applies to cargo/vehicle imaging inspection systems using accelerator produced X-ray or gamma radiation to obtain images of the screened objects (e.g. cargo containers, transport and passenger vehicles and railroad cars). The objective of both standards is to specify standard requirements and general characteristics and test procedures, as well as, radiation, electrical, environmental, mechanical, and safety requirements and to provide examples of acceptable methods to test these requirements. In particular the standards address the design requirements as they relate to the radiation protection of the people being screened, people who are in the vicinity of the equipment and the operators. The standard IEC 62463 does not deal with the performance requirements for the quality of the object detection. Compliance with the standards requirements will provide the manufacturers with internationally acceptable specifications and the device users with assurance of the rigorous quality and accuracy of the measurements in relation to the radiological safety of the equipment. The main characteristics of IEC 62463 and IEC 62523 standards are presented and as well as the IEC methodology of standard development and approval.
This report reviews the latest global and China-specific market trends as well as latest technology and policy trends related to commercial refrigeration equipment, with emphasis on refrigerated display cabinets. Section 2 reviews the global and China market trends for commercial refrigeration equipment. Section 3 presents the latest technology options for improving energy performance and compares global Best Available Technologies (BAT) to regional and China-specific baselines, and discusses low-GWP refrigerant options for commercial refrigeration equipment. Section 4 reviews global energy efficiency standards and labeling programs, and compares international efficiency standard requirements with China’s proposed and existing standard requirements. Section 5 ends with a review of key findings and conclusions.
In 2008 the State of California adopted new building codes that required the use of mechanical ventilation systems in homes that meet the requirements of ASHRAE Standard 62.2. The standard requires both a dwelling unit mechanical ventilation system and exhaust fans in kitchens and bathrooms. A field study was undertaken to evaluate the IAQ and ventilation performance of homes built to these requirements. For ventilation system performance, the airflows of all mechanical ventilation systems were measured and their use was monitored for a one-week period. To evaluate IAQ, key pollutants were measured indoors and outdoors during the week, and occupants completed satisfaction surveys. The key pollutants included: formaldehyde, humidity, PM2.5 and NO2. Passive samplers were used to determine average concentrations for the week. Active samplers were used to develop time-series results that can be used to correlate pollutant concentrations with occupant activities. Other ventilation/IAQ related parameters were also recorded, such as stove top temperatures to indicate cooking, exterior door contact switches to know when large openings were being used for ventilation and sensors to determine when clothes dryers were being used. The building envelope and duct leakage were measured to enable estimates of infiltration and duct leakage effects. This paper presents an overview of the test procedures and preliminary results from several homes. The results show that although average concentrations may be reasonable compared to available standards (with the exception of formaldehyde), occupants have a strong impact on pollutant variability and source strength and that outdoor concentrations cannot be ignored. Overall, these mechanically ventilated homes have reasonable IAQ. The homes and duct systems are moderately tight, though not excessively so, by US standards. Significant concerns have been expressed regarding compliance with the ventilation requirements in the California building code. However, almost all the ventilation systems in this study complied with the ventilation air flow requirements and on average were significantly higher than the minimum required air flow rates.
Reducing energy consumption and greenhouse gas emissions in the built environment is a critical step in achieving emission goals to mitigate climate change impacts. Local, federal, and international jurisdictions are deploying several methods to reduce energy and emissions such as voluntary and mandatory benchmarking and building performance standards, requiring building owners to reach energy and emission targets. Jurisdictions leveraging benchmarking and building performance standards require knowledge of the buildings covered; which is a large task due to staffing constraints, limited information on building characteristics and tax parcel data, and the need for advanced data management techniques to align datasets. This paper describes an open-source platform's recent advances to create consistent taxonomies, identify erroneous data, enable auditability, and track building performance. The paper concludes with two use cases on how the platform has been used by jurisdictions.
The diverse research programs presently in progress around the world have advanced a large number of coated cladding concepts to various stages of maturity. Industry teams have developed leading coating compositions and geometries, but significant disparity exists in the importance placed on different coating properties, as well as the applicability and standardization of the various methods used to measure these properties. This milestone report provides an initial assessment of the most important coating properties and the experimental methods available for their determination to lay the foundation for standardized reporting and development of comprehensive datasets for modeling efforts. This report has determined that the residual stress of the coating is the most crucial property to investigate, yet it has received minimal attention to date due to a knowledge gap about the growth and formation of the brittle Laves phase under reactor conditions. The significance of residual stress of the coating is further enhanced by its connection and interdependence with other important properties like creep and coating failure mechanisms. This milestone proposes an importance rating for residual stress properties and their associated measurement techniques to fill in knowledge. Furthermore, techniques to investigate the outlined properties are discussed, and their capabilities and limitations are illustrated to provide guidance on their use.
A set of standardized and realistic aftertreatment catalyst test protocols have been developed by the Advanced Combustion and Emission Control Technical Team in support of the U.S.DRIVE Partnership. The protocols are intended to accelerate the pace of aftertreatment catalyst innovation by enabling the accurate evaluation and comparison of aftertreatment catalyst performance data from various testing and research facilities to maximize the impact of discovery-phase research occurring across the nation. The protocols address a need identified by the Partnership’s industry partners for consistent and accurate metrics for aftertreatment catalyst evaluation and comparison. The protocols consist of a set of standardized requirements and test procedures that sufficiently capture the performance capability of a catalyst technology in a manner that is adaptable in various laboratories. The protocols provide a detailed description of the necessary reactor system, the steps for achieving a desired aged state of the catalyst, all necessary sample pretreatment to be performed prior to testing, and realistic test conditions for evaluating performance. This article details four low-temperature catalyst test protocols applicable to (1) oxidation catalysts, (2) passive storage (and release) catalysts, (3) three-way catalysts, and (4) NH3-SCR catalysts. The catalyst test protocol descriptions are presented in five (5) sections: protocol general guidelines and the four individual catalyst test protocol descriptions. The general guidelines plus the individual protocol description forms the complete low-temperature catalyst test protocol for the application.
International standards play an important role in the Photovoltaic industry. Since PV is such a global industry it is critical that PV products be measured and qualified the same way everywhere in the world. IEC TC82 has developed and published a number of module and component measurement and qualification standards. These are continually being updated to take advantage of new techniques and equipment as well as better understanding of test requirements. Standards presently being updated include the third edition of IEC 61215, Crystalline Silicon Qualification and the second edition of IEC 61730, PV Module Safety Requirements. New standards under development include qualification of junction boxes, connectors, PV cables, and module integrated electronics as well as for testing the packaging used during transport of modules. After many years of effort, a draft standard on Module Energy Rating should be circulated for review soon. New activities have been undertaken to develop standards for the materials within a module and to develop tests that evaluate modules for wear-out in the field (International PV Module QA Task Force). This paper will discuss these efforts and indicate how the audience can participate in development of international standards.
DNA/RNA-stable isotope probing (SIP) is a powerful tool to link in situ microbial activity to sequencing data. Every SIP dataset captures distinct information about microbial community metabolism, process rates, and population dynamics, offering valuable insights for a wide range of research questions. Data reuse maximizes the information derived from the labor and resource-intensive SIP approaches. Yet, a review of publicly available SIP sequencing metadata showed that critical information necessary for reproducibility and reuse was often missing. Here, we outline the Minimum Information for any Stable Isotope Probing Sequence (MISIP) according to the Minimum Information for any (x) Sequence (MIxS) framework and include examples of MISIP reporting for common SIP experiments. Our objectives are to expand the capacity of MIxS to accommodate SIP-specific metadata and guide SIP users in metadata collection when planning and reporting an experiment. The MISIP standard requires 5 metadata fields—isotope, isotopolog, isotopolog label, labeling approach, and gradient position—and recommends several fields that represent best practices in acquiring and reporting SIP sequencing data (e.g., gradient density and nucleic acid amount). The standard is intended to be used in concert with other MIxS checklists to comprehensively describe the origin of sequence data, such as for marker genes (MISIP-MIMARKS) or metagenomes (MISIP-MIMS), in combination with metadata required by an environmental extension (e.g., soil). The adoption of the proposed data standard will improve the reuse of any sequence derived from a SIP experiment and, by extension, deepen understanding of in situ biogeochemical processes and microbial ecology.
The purpose of this study was to perform a comparative analysis of powder-bed-based additive manufacturing (AM) technologies during the production of metallic components using Inconel 625 powder material. The AM technologies explored in this study include electron beam powder bed fusion (EPBF), laser powder bed fusion (LPBF), and binder jetting technology. Samples were fabricated in two build directions (X and Z build orientations) for this evaluation process, where all specimens underwent a hot isostatic pressing (HIP) post-process. The comparison was made in terms of microstructure and mechanical properties including ultimate tensile strength (UTS), yield strength (YS), percent elongation, and modulus of elasticity (E). Microstructural characterization showed evidence of equiaxed grain formation for binder jetting and LPBF parts, whereas EPBF parts displayed a more columnar grain formation parallel to the build direction. Six specimens were tested per technology, three built in the X orientation and three built in the Z orientation. All six specimens were built in a single run of each AM machine. Results indicated that all three technologies are capable of meeting the minimum requirements of the ASTM F3056-14 standard for parts produced in the X orientation, with properties that are similar to wrought Inconel 625. In the Z orientation, however, only LPBF was able to meet the minimum standard requirements. Through the comparative analysis of the mechanical properties, here this work showed that LPBF outperformed the other technologies in a majority of the evaluated properties, followed by EPBF and binder jetting. An analysis of the fracture surfaces of tensile specimens was also performed, and it indicated ductile fracture (dimple rupture) for the specimens produced with all three of the AM technologies studied. Nevertheless, the characterization also showed certain differences in the fractured surfaces, such as the presence of un-sintered powder particles for the binder jetting processed Inconel 625, or the development of the so called woody structure for the EPBF processed material. This study can be used to determine distinct characteristics between the three powder-bed-based technologies for the fabrication of Inconel 625 that can further include other technologies and materials using similar approaches.
The tritium aspects of the DT fuel cycle embody some of the most challenging feasibility and attractiveness issues in the development of fusion systems. The review and analyses in this paper provide important information to understand and quantify these challenges and to define the phase space of plasma physics and fusion technology parameters and features that must guide a serious R&D in the world fusion program. We focus in particular on components, issues and R&D necessary to satisfy three 'principal requirements': (1) achieving tritium self-sufficiency within the fusion system, (2) providing a tritium inventory for the initial start-up of a fusion facility, and (3) managing the safety and biological hazards of tritium. A primary conclusion is that the physics and technology state-of-the-art will not enable DEMO and future power plants to satisfy these principal requirements. We quantify goals and define specific areas and ideas for physics and technology R&D to meet these requirements. A powerful fuel cycle dynamics model was developed to calculate time-dependent tritium inventories and flow rates in all parts and components of the fuel cycle for different ranges of parameters and physics and technology conditions. Dynamics modeling analyses show that the key parameters affecting tritium inventories, tritium start-up inventory, and tritium self-sufficiency are the tritium burn fraction in the plasma (f b ), fueling efficiency (η f ), processing time of plasma exhaust in the inner fuel cycle (t p ), reactor availability factor (AF), reserve time (tr) which determines the reserve tritium inventory needed in the storage system in order to keep the plant operational for time t r in case of any malfunction of any part of the tritium processing system, and the doubling time (t d ). Results show that η f f b > 2% and processing time of 1–4 h are required to achieve tritium self-sufficiency with reasonable confidence. For η f f b = 2% and processing time of 4 h, the tritium start-up inventory required for a 3 GW fusion reactor is ~11 kg, while it is <5 kg if η f f b = 5% and the processing time is 1 h. To achieve these stringent requirements, a serious R&D program in physics and technology is necessary. The EU-DEMO direct internal recycling concept that carries fuel directly from the plasma exhaust gas to the fueling systems without going through the isotope separation system reduces the overall processing time and tritium inventories and has positive effects on the required tritium breeding ratio (TBR R ). A significant finding is the strong dependence of tritium self-sufficiency on the reactor availability factor. Simulations show that tritium self-sufficiency is: impossible if AF < 10% for any η f f b , possible if AF > 30% and 1% ≤ η f f b ≤ 2%, and achievable with reasonable confidence if AF > 50% and η f f b > 2%. These results are of particular concern in light of the low availability factor predicted for the near-term plasma-based experimental facilities (e.g. FNSF, VNS, CTF), and can have repercussions on tritium economy in DEMO reactors as well, unless significant advancements in RAMI are made. There is a linear dependency between the tritium start-up inventory and the fusion power. The required tritium start-up inventory for a fusion facility of 100 MW fusion power is as small as 1 kg. Since fusion power plants will have large powers for better economics, it is important to maintain a 'reserve' tritium inventory in the tritium storage system to continue to fuel the plasma and avoid plant shutdown in case of malfunctions of some parts of the tritium processing lines. But our results show that a reserve time as short as 24 h leads to unacceptable reserve and start-up inventory requirements. Therefore, high reliability and fast maintainability of all components in the fuel cycle are necessary in order to avoid the need for storing reserve tritium inventory sufficient for continued fusion facility operation for more than a few hours. The physics aspects of plasma fueling, tritium burn fraction, and particle and power exhaust are highly interrelated and complex, and predictions for DEMO and power reactors are highly uncertain because of lack of experiments with burning plasma. Fueling by pellet injection on the high field side of tokamak has evolved to be the preferred method to fuel a burning plasma. Extrapolation from the DIII-D penetration scaling shows fueling efficiency expected in DEMO to be <25%, but such extrapolations are highly uncertain. The fueling efficiency of gas in a reactor relevant regime is expected to be extremely poor and not very useful for getting tritium into the core plasma efficiently. Gas fueling will nonetheless be useful for feedback control of the divertor operating parameters. Extensive modeling has been carried out to predict burn fraction, fueling requirements, and fueling efficiency for ITER, DEMO, and beyond. The fueling rate required to operate Q = 10 ITER plasmas in order to provide the required core fueling, helium exhaust and radiative divertor plasma conditions for acceptable divertor power loads was calculated. If this fueling is performed with a 50–50 DT mix, the tritium burn fraction in ITER would be ~0.36%, which is too low to satisfy the self-sufficiency conditions derived from the dynamics modeling for fusion reactors. Extrapolation to DEMO using this approach would also yield similarly low burn fraction. Extensive analysis presented shows that specific features of edge neutral dynamics in ITER and fusion reactors, which are different from present experiments, open possibilities for optimization of tritium fueling and thus to improve the burn fraction. Using only tritium in pellet fueling of the plasma core, and only deuterium for edge density, divertor power load and ELM control results in significant increase of the burn fraction to 1.8–3.6%. These estimates are performed with physics models whose results cannot be fully validated for ITER and DEMO plasma conditions since these cannot be achieved in present tokamak experiments. Thus, several uncertainties remain regarding particle transport and scenario requirements in ITER and DEMO. The safety standard requirements for protection of the public and release guidelines for tritium have been reviewed. General safety approaches including minimizing tritium inventories, reducing tritium permeation through materials, and decontaminating material for waste disposal have been suggested.
Many workplaces contain spaces that are considered to be “confined” because their configuration hinders the activities of employees who must enter into, work in, and exit from them. In general, the permit-required confined spaces (PRCSs) Occupational Safety and Health Administration (OSHA) standard requires that Los Alamos National Laboratory (LANL) evaluate the workplace to determine if any spaces are PRCSs. The standard specifies strict procedures for the evaluation and atmospheric testing of a space before and during an entry by workers. The OSHA PRCS standard provides for alternative (less stringent than full-permit) entry procedures in cases where the only hazard in a space is atmospheric and the hazard can be controlled by forced air. At LANL, all confined spaces or potential confined spaces on LANL-owned or -operated property must be identified and evaluated by a confined space evaluator accompanied by a knowledgeable person. This course provides the information needed by confined space evaluators to make judgements about whether a space is a confined space, and if so, whether the space will require a permit for entry.