Search NASA⌕ Search

SEARCH · Search NASA

Results for “Requirements satisfaction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2023 Annual Report: Laboratory Directed Research & Development Program Activities

Each year, Brookhaven National Laboratory (BNL) is required to provide a report of its completed Laboratory Directed Research and Development Program (LDRD) projects to the Department of Energy (DOE) Office of Scientific and Technical Information in accordance with DOE Order 413.2C Chg1 (MinChg) dated August 2, 2018. This summary report provides an overview of all the LDRD projects funded at Brookhaven that concluded in FY 2023 in satisfaction of that requirement.

99 GENERAL AND MISCELLANEOUS↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid learning techniques for scientific data reduction with performance guarantees

The research initiatives supported by the U.S. Department of Energy (DOE) Grant DE-SC0022265 are fundamentally aimed at pioneering advanced machine learning (ML) techniques for scientific data compression within high-performance computing (HPC) environments. This comprehensive body of work addresses the critical challenge posed by the exponential growth of data generated by scientific simulations in domains such as fusion energy, climate modeling, and computational fluid dynamics (CFD). A core objective is to develop compression algorithms that achieve substantial data reduction—often by orders of magnitude—while rigorously ensuring the fidelity of both the primary data (PD) and scientifically crucial derived quantities of interest (QoI). The methodologies deployed under this grant integrate sophisticated deep learning architectures, prominently featuring autoencoders, advanced generative models like conditional diffusion, and hybrid learning techniques. Key innovations include the development of Guaranteed Autoencoders (GAE) and the Guaranteed Conditional Diffusion with Tensor Correction (GCDTC) framework, which provide explicit, instance-level error bounds on reconstructed data. Furthermore, specialized strategies such as nonlinear constraint satisfaction are employed to preserve the integrity of QoI, a vital requirement for the trustworthiness of downstream scientific analyses. This research also focuses on the design and implementation of scalable, GPU-accelerated software pipelines that seamlessly integrate into existing HPC workflows, ensuring both computational efficiency and practical applicability. The CAESAR framework, for example, unifies foundation and generative models to create an adaptive and efficient compression solution for spatio-temporal scientific data. Collectively, these efforts represent a significant advancement in mitigating the scientific data deluge, enabling more effective data management, accelerated scientific discovery, and optimized utilization of HPC resources.

97 MATHEMATICS AND COMPUTING↗

Final report- UFL - RAPIDS2: A SciDAC Institute for Computer Science, Data, and Artificial Intelligence

The research initiatives supported by the U.S. Department of Energy (DOE) Grant DE-SC0022265 are fundamentally aimed at pioneering advanced machine learning (ML) techniques for scientific data compression within high-performance computing (HPC) environments. This comprehensive body of work addresses the critical challenge posed by the exponential growth of data generated by scientific simulations in domains such as fusion energy, climate modeling, and computational fluid dynamics (CFD). A core objective is to develop compression algorithms that achieve substantial data reduction—often by orders of magnitude—while rigorously ensuring the fidelity of both the primary data (PD) and scientifically crucial derived quantities of interest (QoI). The methodologies deployed under this grant integrate sophisticated deep learning architectures, prominently featuring autoencoders, advanced generative models like conditional diffusion, and hybrid learning techniques. Key innovations include the development of Guaranteed Autoencoders (GAE) and the Guaranteed Conditional Diffusion with Tensor Correction (GCDTC) framework, which provide explicit, instance-level error bounds on reconstructed data. Furthermore, specialized strategies such as nonlinear constraint satisfaction are employed to preserve the integrity of QoI, a vital requirement for the trustworthiness of downstream scientific analyses. This research also focuses on the design and implementation of scalable, GPU-accelerated software pipelines that seamlessly integrate into existing HPC workflows, ensuring both computational efficiency and practical applicability. The CAESAR framework, for example, unifies foundation and generative models to create an adaptive and efficient compression solution for spatio-temporal scientific data. Collectively, these efforts represent a significant advancement in mitigating the scientific data deluge, enabling more effective data management, accelerated scientific discovery, and optimized utilization of HPC resources.

97 MATHEMATICS AND COMPUTING↗

Evaluating HPC Scheduling Strategies for Urgent Workloads

Scientific computing centers increasingly face workloads with diverse urgency requirements, driven by applications that demand rapid or even immediate execution. Appropriately configured scheduling policies can significantly improve both user satisfaction and overall cluster utilization. In this work, we present a systematic analysis of scheduler configurations under scenarios where a fraction of jobs have urgent computing needs. We evaluate multiple job scheduling simulators, develop a lightweight job-submission emulation framework, and create tools to analyze and visualize the resulting scheduling data. Our study identifies key trade-offs between responsiveness, fairness, and efficiency, and offers a set of practical scheduling configurations (particularly for Slurm) that can be tailored to HPC environments supporting mixed-urgency workloads.

Maheshwari, Ketan [ORNL] (ORCID:000000033800662X)↗

Scalable Hybrid Learning Techniques for Scientific Data Compression

Data compression is becoming critical for storing scientific data because many scientific applications need to store large amounts of data and post process this data for scientific discovery. Unlike image and video compression algorithms that limit errors to primary data (PD), scientists require compression techniques that accurately preserve derived quantities of interest (QoIs). Here, this article presents a physics-informed compression technique implemented as an end-to-end, scalable, GPU-based pipeline for data compression that addresses this requirement. Our hybrid compression technique combines machine learning techniques and standard compression methods. Specifically, we combine an autoencoder, an error-bounded lossy compressor to provide guarantees on raw data error, and a constraint satisfaction post-processing step to preserve the QoIs within a minimal error (generally less than floating point error). The effectiveness of the data compression pipeline is demonstrated by compressing nuclear fusion simulation data generated by a large-scale fusion code, XGC, which produces hundreds of terabytes of data in a single day. Our approach works within the ADIOS framework and results in compression by a factor of more than 150 while requiring only a few percent of the computational resources necessary for generating the data, making the overall approach highly effective for practical scenarios.

ITER↗

Safe Deep Reinforcement Learning for Active Distribution System Model Predictive Control with EVs and DERs

The temporal and spatial mismatch between PV generation and electric vehicle (EV) charging and discharging may cause voltage violations in active distribution networks. Despite the widespread use of deep reinforcement learning (DRL) in power system optimization and control, it lacks guarantees on constraint satisfaction during both training and deployment. This paper proposes a Lagrangian-based safe DRL approach for model predictive control (MPC) of active distribution systems with large-scale integration of PVs, EVs, and energy storage systems (ESSs). A Transformer-LSTM time-series model is proposed to forecast EV charging demand, which is then formulated as a constraint to ensure charging requirements are met. Using this prediction, a Lagrangian-based safe soft actor-critic (SAC) framework is developed for real-time control in a three-phase unbalanced distribution system, enforcing voltage safety constraints while optimizing the cumulative net reward. By integrating the forecasting model with multi-period constraints, the proposed framework jointly coordinates PV systems, EV charging and discharging, and ESS scheduling within the MPC horizon. Numerical experiments on a modified IEEE 123-bus system with real-world data show that, under a high PV penetration scenario, the proposed method increases the net reward by 30.74% and reduces average voltage violations from 0.0011 p.u. to 0.0002 p.u. compared with standard SAC. Compared with the optimal power flow (OPF) approach, it achieves similar voltage security while yielding lower line losses. It also maintains real-time control capability, reducing operation latency to 53.21 ms per 15-minute control interval. The proposed method remains effective under varying PV/EV penetrations and load conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bayesian Entropy Neural Networks for physics-aware prediction

This article addresses the need for deep learning models to integrate well-defined constraints into their outputs, driven by their application in surrogate models, learning with limited data and partial information, and scenarios requiring flexible model behavior to incorporate non-data sample information. We introduce Bayesian Entropy Neural Networks (BENN), a framework grounded in Maximum Entropy (MaxEnt) principles, designed to impose constraints on Bayesian Neural Network (BNN) predictions. BENN is capable of constraining not only the predicted values but also their derivatives and variances, ensuring a more robust and reliable model output. To achieve simultaneous uncertainty quantification and constraint satisfaction, we employ the method of multipliers approach. This allows for the concurrent estimation of neural network parameters and the Lagrangian multipliers associated with the constraints. Our experiments, spanning diverse applications such as beam deflection modeling and microstructure generation, demonstrate the effectiveness of BENN. The results highlight significant improvements over traditional BNNs and showcase competitive performance relative to contemporary constrained deep learning methods.

14 SOLAR ENERGY↗

Public water supply infrastructure extensification and diversification in surface waters is insufficient to meet future demands in Texas

The data were developed to evaluate the capacity of existing and potential new surface water supply infrastructure to meet projected public water demands across districts in Texas under multiple future socioeconomic and climate scenarios. The database integrates hydrologic, water quality, infrastructure, energy, cost, demographic, and demand-projection information for candidate surface water supply locations. Candidate sites include stream reaches, waterbodies, reservoir surplus locations, and potential new reservoir sites. Water availability is characterized using historical and projected flow conditions, while site suitability is evaluated using five indicators: Water Availability Index (WAI), Water Quality Index (WQI), Energy Requirement Index (ERI), Water Treatment Cost (WTC), and Water Infrastructure Cost (WIC). The datasets include statewide candidate-site information, district-level demand projections under Shared Socioeconomic Pathways (SSPs), runoff-based allocation constraints, climate-stress metrics, and optimization outputs evaluating alternative infrastructure planning strategies. Optimization results compare Business-as-Usual (BAU) and All Surface Water (AllSW) demand-management approaches under both scaled and fixed cost-cap strategies. Associated validation datasets provide district-level feasibility assessments, infrastructure selection outcomes, cost-cap utilization, demand satisfaction metrics, and constraint diagnostics. Additional datasets quantify projected changes in storage and flow conditions as well as water availability stress for both existing and newly selected intake locations under the SSP5 scenario for mid-century and late-century climate conditions. Together, these datasets support assessment of the extent to which surface-water infrastructure expansion and diversification strategies can satisfy future public water demands while accounting for hydrologic, economic, and planning constraints across Texas. Dataset(s) Description Dataset_preoptimization.xlsx Comprehensive pre-optimization dataset containing candidate water-supply sites and associated hydrologic, water-quality, infrastructure, climate, demographic, runoff, and demand-projection variables used as inputs to the optimization analyses. Includes variable descriptions and the full statewide candidate-site database. District_level_site_selection.zip - Compressed archive containing all SSP-specific district-level optimization result files MESIO_ssp1_results.xlsx District-level site selection results for SSP1 (MESIO). Includes variable descriptions, BAU and AllSW site-selection results under scaled and fixed cost strategies, and district-level validation diagnostics. MESID_ssp2_results.xlsx District-level site selection results for SSP2 (MESID). Includes variable descriptions, BAU and AllSW site-selection results under scaled and fixed cost strategies, and district-level validation diagnostics. LCMRD_ssp3_results.xlsx District-level site selection results for SSP3 (LCMRD). Includes variable descriptions, BAU and AllSW site-selection results under scaled and fixed cost strategies, and district-level validation diagnostics. IRDev-Low_ssp4l_results.xlsx District-level site selection results for SSP4-Low (IRDev-Low). Includes variable descriptions, BAU and AllSW site-selection results under scaled and fixed cost strategies, and district-level validation diagnostics. IRDev-High_ssp4h_results.xlsx District-level site selection results for SSP4-High (IRDev-High). Includes variable descriptions, BAU and AllSW site-selection results under scaled and fixed cost strategies, and district-level validation diagnostics. RSIM_ssp5_results.xlsx District-level site selection results for SSP5 (RSIM). Includes variable descriptions, BAU and AllSW site-selection results under scaled and fixed cost strategies, and district-level validation diagnostics. tx_hydrological_stress.xlsx Hydrological stress dataset for existing and newly selected intake locations. Includes projected mid-century and late-century changes, gain/loss classifications, planning strategy information, and accompanying variable descriptions. Also includes water-stress metrics derived from historical and projected low-flow conditions.

Okoye, Perpetua I. (ORCID:0000000215545033)↗

Implementing an Objectives-Driven, Risk-Informed, and Case-Assured Approach to Safety and Mission Success at NASA

NASA is developing a “Standard for Assurance of Space Flight Safety and Mission Success” that implements an objectives-driven, risk-informed, and case-assured approach to safety and mission success (S&MS) for NASA space flight programs and projects. The standard aligns with the philosophy of risk leadership that has recently been established in NASA policy to assure acceptable levels of flight crew safety and mission success risk. It is consistent with existing NASA risk management requirements and is compatible with NASA program management and systems engineering requirements. The methodology described in the standard is presented in terms of an S&MS assurance framework that is designed to allow substantial flexibility in the specific means by which programs and projects achieve acceptable mission S&MS risk. Such flexibility is necessary to accommodate the increasingly broad range of acquisition strategies employed by NASA, including commercial transportation services, as well as to accommodate the increasingly rapid evolution of space flight-related technologies and practices. A key feature of the S&MS assurance framework is the specification of S&MS success criteria for each life-cycle review (LCR). The S&MS assurance case is structured around these criteria, the satisfaction of which indicates that the program/project is adhering to the S&MS risk posture. This enables the evolving S&MS assurance case to be used as a fundamental program/project submittal at each LCR, where its inherent structure of argument, supported by evidence, directly supports the evaluation of the program/project with respect to the S&MS success criteria, and by extension, the S&MS risk posture. As such, the S&MS assurance case is integral to program/project systems engineering, risk management, and S&MS oversight activities, and provides the principal basis for S&MS risk acceptance by the Decision Authority throughout the program/project life cycle.

42 ENGINEERING↗

Risk-Aware Reinforcement Learning Framework for User-Centric O-RAN

The evolution of Open Radio Access Networks (O-RAN) presents an opportunity to enhance network performance by enabling dynamic orchestration of configuration and optimization parameters (COPs) through online learning methods. However, leveraging this potential requires overcoming the limitations of traditional cell-centric RAN architectures, which lack the necessary flexibility. On the other hand, despite their recent popularity, the practical deployment of online learning frameworks, such as Deep Reinforcement Learning (DRL)-based COP optimization solutions, remains limited due to their risk of deteriorating network performance during the exploration phase. In this article, we propose and analyze a novel risk-aware DRL framework for user-centric RAN (UC-RAN), which offers both the architectural flexibility and COP optimization to exploit this flexibility. We investigate and identify UC-RAN COPs that can be optimized via a soft actor-critic algorithm implementable as an O-RAN application (rApp) to jointly maximize latency satisfaction, reliability satisfaction, area spectral efficiency, and energy efficiency. We use the offline learning on UC-RAN to reliably accelerate DRL training, thus minimizing the risk of DRL deteriorating cellular network performance. Results show that our proposed solution approaches near-optimal performance in just a few hundred iterations with a decrease in risk score by a factor of ten.

6G and beyond↗

Queue wait time prediction in high performance computing (HPC) systems

High Performance Computing (HPC) systems are critical enablers for groundbreaking scientific research across various domains. Efficient resource allocation, facilitated by job scheduling, is paramount for maximizing the utilization of HPC systems. However, the variability in wait times for queued jobs poses challenges for users, necessitating accurate job wait time estimation. This paper explores the influence of job characteristics, including job size (the number of nodes requested and walltime), the queue to which the job is submitted and other resource requirements, on job wait times in leadership-class HPC systems. Focusing on the Theta Cray XC40 and Polaris machines at Argonne National Laboratory, the study evaluates the performance of different supervised learning algorithms in predicting job wait times. It also evaluates the impact of data preprocessing, including outlier detection, Principal Component Analysis (PCA), and feature selection, on the performance of wait time prediction models. The findings reveal insights into the relationship between job characteristics and wait times, offering a foundation for optimizing resource allocation and enhancing user experience. The methodologies and tools developed in this study are adaptable to other leadership-class HPC systems, providing a valuable contribution to the broader HPC community aiming to improve job scheduling efficiency and user satisfaction.

Okafor, Nwamaka↗

User-Centric Communication With Aerial Network for 6G: A Reinforcement Learning Approach

Meeting the diverse needs of user verticals requires innovative cellular architectures that can offer additional degrees of freedom to provide on-demand services. The terrestrial user-centric radio access network (UC-RAN) stands out as an excellent choice for this purpose. However, a drawback of UC-RAN is its tendency to prioritize high-priority verticals, often resulting in a subpar quality of experience for low-priority verticals. This issue is particularly exacerbated in hotspot areas. Here, to address this problem, we introduce an aerial network integrated with terrestrial UC-RAN to provide coverage to users which are not served by the terrestrial network. Furthermore, we analyze the impact of key configuration and optimization parameters (COPs), such as location, transmit power, altitude, and beamwidth of aerial base stations (ABSs) on system key performance indicators (KPIs), such as coverage, latency satisfaction, average spectral efficiency, and energy efficiency. We formulate a robust multiobjective function to maximize these KPIs without biasing toward any specific KPI(s). Finally, we propose a deep reinforcement learning optimization framework based on the state-of-the-art soft actor-critic algorithm to control ABS COPs and optimize system KPIs. Experimental evaluations demonstrate that the proposed optimization framework can converge to near-optimal solutions derived from the pseudo brute force in a few thousand epochs.

6G↗

Understanding EV Charging Pain Points Through Deep Learning Analysis

Current and potential electric vehicle (EV) owners express concerns about the charging infrastructure, mentioning non-functional chargers, prolonged charging times, inconvenient charger locations, long wait times, and high costs as major barriers. Addressing these issues often requires analyzing actual vehicle charging data, which is typically proprietary and inconsistent due to diverse standards and protocols. To understand and improve the EV charging experience, customer reviews are typically used to identify common customer pain points (CPPs). However, there is not a comprehensive method to map customer reviews to a standardized set of CPPs. In collaboration with the National Charging Experience (ChargeX) Consortium, this study bridges these gaps by proposing a Systematic Categorization and Analysis of Large-scale EV-charging Reviews (SCALER) framework. SCALER is an integrated, deep learning framework that segments, actively labels, analyzes, and classifies EV charging customer reviews into six CPP categories. To test its effectiveness, we used SCALER to analyze over 72,000 reviews from customers charging various EV models on different networks across the United States. SCALER achieves a classification accuracy of 92.5%, with an F1 score exceeding 85.7%. By demonstrating real-world applications of SCALER, we enhance the industry’s ability to understand and address CPPs to improve the EV charging experience.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗