Search NASA⌕ Search

SEARCH · Search NASA

Results for “Resistive Anode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optimizing the position resolution of a Z-stack microchannel plate resistive anode detector for low intensity signals

A method for achieving good position resolution of low-intensity electron signals using a microchannel plate resistive anode detector is demonstrated. Electron events at a rate of 7 counts s{sup −1} are detected using a Z-stack microchannel plate. The dependence of position resolution on both the distance and the potential difference between the microchannel plate and resistive anode is investigated. Using standard commercial electronics, a measured position resolution of 170 μm (FWHM) is obtained, which corresponds to an intrinsic resolution of 157 μm (FWHM)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resistive anode image converter

The invention of an apparatus for imaging soft X-ray and ultraviolet electromagnetic radiation and charged particles was described. The apparatus includes a pair of microchannel electron multiplier plates connected in a cascaded chevron configuration which intercepts an incident beam of radiation or charged particles. Incident photons or charged particles strike the front surface of the chevron configuration causing emission of electrons. The electrons are accelerated by a voltage gradient and strike the inner side walls of the individual channels, causing emission of secondary electrons. Accelerated and multiplied secondary electrons impinge upon a resistive anode after they transverse the chevron configuration. A pulse position circuit converts the magnitude or transit time of the currents flowing from the point of impact of the electrons on the resistive anode to four contact electrodes mounted on their periphery of the resistive anode into the spatial coordinates of electron impact.

Lampton, M. L.↗

Low-distortion resistive anodes for two-dimensional position-sensitive MCP systems

Microchannel plates (MCPs) are frequently used with resistive anodes to detect charged particles or photons and yield analog signals from which event positions can be decoded. The paper discusses a four-corner concave circular arc terminated resistive anode that permits theoretically distortionless encoding of Cartesian event positions into pulse charge ratios. The theory of the circular arc terminated anode is discussed along with anode design and performance. Electron beam images obtained by using such an anode are presented to confirm the usefulness of the approach.

Lampton, M.↗

Correlation between corrosion resistance, anodic hydrogen evolution and microhardness in friction stir weldment of AA2198 alloy

Highlights: • There is a relationship between hardness, corrosion and H{sub 2} evolution in AA2198-T851 alloy friction stir weldment • Variation in the population density of T1 particles is the correlating factor for the relationship • The parent material is the region that is most susceptible to corrosion. • The weld zones of AA2198-T851 alloy friction stir weldment exhibit different forms of corrosion. - Abstract: Correlation between corrosion resistance, anodic hydrogen evolution and microhardness in the friction stir weldment of AA2198-T851 alloy has been investigated. Different microscopy techniques, scanning vibrating electrode technique (SVET) and potentiodynamic polarization tests were employed in the investigation. Unlike other 3rd generation Al-Cu-Li alloys where the regions that are most susceptible to corrosion are always within the weld region, the results reveal that the parent material is the most susceptible in this case. There is a direct correlation between corrosion resistance, anodic hydrogen evolution and microhardness in the weldment, and the T{sub 1} phase is associated with the direct correlation.

36 MATERIALS SCIENCE↗

Using pulse shape analysis to improve the position resolution of a resistive anode microchannel plate detector

Digital signal processing techniques were employed to investigate the joint use of charge division and risetime analyses for the resistive anode (RA) coupled to a microchannel plate detector (MCP). In contrast to the typical approach of using the relative charge at each corner of the RA, this joint approach results in a significantly improved position resolution. A conventional charge division analysis utilizing analog signal processing provides a measured position resolution of 170 μm (FWHM). By using the correlation between risetime and position we were able to obtain a measured resolution of 92μm (FWHM), corresponding to an intrinsic resolution of 64μm (FWHM) for a single Z-stack MCP detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution imaging with a two-dimensional resistive anode photon counter

A method to achieve high spatial resolution readout of individual photoelectron events using microchannel plates and a resistive anode is presented. A clamped pair of microchannel plates is used, followed by a gap and a clamped triplet of microchannel plates in cascade to achieve a high stable electron gain of 3 x 10 to the 7th. The gain allows the position determination of each photoelectron event with a very high signal-to-noise ratio. A model consisting of a windowless vacuum-ultraviolet image sensor is presented to demonstrate 500 x 500 pixel images of 50 micron FWHM over a 25-mm circular field of view. The detector offers sufficient speed, sensitivity and resolution for a variety of applications, and the mount design is compatible with planar, remotely-processed, proximity-focused photocathodes.

Firmani, C.↗

The Ranicon - A resistive anode image converter

A versatile photon and charged particle imaging system is described. The Ranicon employs a microchannel electron multiplier plate to convert each detected event into a charge signal. This charge pulse is proximity-focused onto a large-area resistive anode plate equipped with pickup electrodes on its edges. Each event is located electronically by the ratios of the charges collected at the edges or by the differences of the signals' risetimes. One- or two-dimensional pictures are built up by storing events digitally (e.g., a core memory) or in analog form (e.g., a storage oscilloscope). Compact laboratory models have been constructed and tested. Operating characteristics, applications, limitations, and advantages of the Ranicon are discussed.

Lampton, M.↗

Anion-Intercalating Cathodes for High-Energy-Density Cells

A report discusses physicochemical issues affecting a fluoride-intercalating cathode that operates in conjunction with a lithium ion-intercalating anode in a rechargeable electrochemical cell described in a cited prior report. The instant report also discusses corresponding innovations made in solvent and electrolyte compositions since the prior report. The advantages of this cell, relative to other lithium-ion-based cells, are said to be greater potential (5 V vs. 4 V), and greater theoretical cathode specific capacity (0.9 to 2.2 A-h/g vs. about 0.18 A-h/g). The discussion addresses a need for the solvent to be unreactive toward the lithium anode and to resist anodic oxidation at potentials greater than about 4.5 V vs. lithium; the pertinent innovation is the selection of propylene carbonate (PC) as a solvent having significantly more stability, relative to other solvents that have been tried. The discussion also addresses the need for an electrolyte additive, denoted an anion receptor, to complex the fluoride ion; the pertinent innovation is the selection of tris(hexafluoroisopropyl) borate as a superior alternative to the prior anion receptor, which was tris(pentafluorophenyl) borate.

West, William↗

Hybrid analog/digital, large format, photon counting detectors for astronomy

The development of a new microchannel plate photon-counting detector with an analog readout method based on a resistive anode is reported. This detector exhibits extremely high, stable electron gains of 10 to the 8th. At this gain, the spatial resolution is no longer primarily limited by the noise of the resistive anode, so that digital methods of readout, such as discrete conductors, lose their advantage. These detectors can be readily scaled to 40 mm and 70 mm formats to match plate scales of 2-m (and larger) telescopes. New, high speed digital electronics fully exploit the high spatial and time resolution made possible by gains of this level. Analysis of the theoretical performance of this detector shows that the major limitation to the spatial resolution is the proximity focus of the photocathode and the first microchannel plate. The detector has been mated to an echelle spectrograph developed.

Crocker, J.↗

A Dendrite-Resistant Sodium/Porous-Carbon Anode for Solid-State Batteries – Strategies and Challenges for Low-Pressure Operation

Sodium solid-state batteries (Na-SSB) have gained interest recently due to the abundance of Na over Li, but they still tend to fail due to dendrites under practical current densities and cycling capacities. To overcome this, Na-SSBs are frequently tested with impractically high applied pressure. In this work, a porous carbon interfacial layer is utilized in conjunction with Na-ß”-Al2O3 solid electrolytes to enable Na-cycling at milder cell pressures. This sodium/porous carbon layer enables improved solid-state Na cycling in symmetric cells, up to a current density of 10 mA cm-2 at 25 °C. Cycling up to 1 mAh cm-2 is challenging with low pressure, but 1 mAh cm-2 capacity can be reliably cycled at 1 mA cm-2 at an elevated temperature of 60 °C in symmetric cells. Finally, the evolution of the interface and sodium/carbon anode is evaluated with cryogenic ion-milling and cross-sectional imaging revealing that, depending on testing temperature, pressure, current density, and capacity, void formation, Na-extraction from porous carbon, delamination of the porous carbon matrix, or a combination of these occurs at the interface between Na-metal and BASE. Despite this, excellent dendrite resistance is achieved, and a full-cell design utilizing a Na-transition metal oxide cathode is still able to achieve an areal capacity of ~ 2.7 mAh cm-2 at 0.125 mA cm-2. This work demonstrates an alternative pathway toward a Na-metal anode for Na-SSBs without the requirement of excessive stack pressure.

low-cost↗

A redox-reversible A/B-site co-doped BaFeO 3 electrode for direct hydrocarbon solid oxide fuel cells

Solid oxide fuel cells (SOFCs) can directly convert the chemical energy in fuel to electrical energy with fuel flexibility; however, the conventional nickel-based anodes face great challenges due to coking upon direct oxidation of hydrocarbon fuels and redox instability. Thus, developing new anode materials which can provide high coking resistance as well as redox stability is crucial. In this work, Ba 0.6 La 0.4 Fe 0.8 Mo 0.1 Ni 0.1 O 3-δ (BLFMN) has been synthesized in air using a sol–gel combustion method, resulting in a dual phase consisting of a cubic BLFMN main phase and scheelite BaMoO 4 (BMO 4 ) secondary phase. By heat-treating the BLFMN dual phase in H 2 at 800 °C for 5 h, a metallic nanoparticle-decorated BLFMN triple phase compound comprising cubic BLFMN, cubic BaMoO 3 (BMO 3 ) and in situ exsolved FeNi 3 alloy was obtained. BLFMN was subsequently investigated as an electrode material for La 0.8 Sr 0.2 Ga 0.83 Mg 0.17 O 3-δ (LSGM) electrolyte (300 μm) supported SOFCs. Symmetrical cells using BLFMN as electrodes with the cell configuration of BLFMN//LSGM//BLFMN showed excellent redox reversibility and a peak power density (PPD) of 1.32 W cm -2 at 850 °C when using H 2 as fuel. Single cell with the cell configuration of BLFMN//LSGM//LSCF (La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-δ ) reached PPD of 1.61 and 0.41 W cm -2 at 850 °C when operating with H 2 and CH 4 fuel, respectively. Moreover, the single cell exhibit excellent stability (over 300 h) upon direct oxidation of hydrocarbon fuels of CH 4 and C 3 H 8 . This study indicates that BLFMN is a promising redox reversible and coking resistant anode for SOFCs.

08 HYDROGEN↗

Parallel-plate avalanche counters for heavy-ion beam tracking: History and mysteries

Despite being an old detector concept, position-sensitive parallel-plate avalanche counters (PPACs) remain widely used today for heavy-ion position and timing measurements. In modern rare isotope beam facilities and large-acceptance fragment separators, PPACs are used to characterize beam properties (diagnostics), facilitate beam delivery (tuning), and provide event-by-event beam tracking for particle identification (PID). Most popular particle localization methods in PPAC detectors are based on strip electrodes electrically connected to resistive-chain circuits or delay lines. More exotic systems include optical readouts based on recording electroluminescence light with high-granularity photodetector arrays or high-resolution resistive anode electrodes. PPACs with conventional resistive-chain or delay-line readouts achieve typical position and time resolutions of below 1 mm ( σ ) and around 150 ps ( σ ), respectively. In addition, delay-line systems are capable of counting rates above several hundred kHz for beam areas of a few millimeters square, and around 1 MHz for larger beam sizes. Resistive-chain readouts have limited rates of a few tens of kHz. A review of the operation principles and performance of PPAC detectors is presented in this paper. We will discuss decades-long experience building and operating PPACs developed at the National Superconducting Cyclotron Laboratory, and then refined at the Facility for Rare Isotope Beams (FRIB), mostly focusing on the delay-line readout technique (DLPPAC). We will also discuss problems that arise due to electric discharges at high rates and briefly describe ongoing developments at FRIB. Published by the American Physical Society 2024

Physics↗

Delay line anodes for microchannel-plate spectrometers

A photon-counting readout system for microchannel-plate spectrometers is described that uses a delay line and timing circuit for the wavelength coordinate and a wedge-wedge charge division system for the orthogonal spatial coordinate. A novel zigzag layout allows these two anode patterns to coexist on a common planar substrate and share the charge from each photoevent, thereby simultaneously localizing the photon in each of its two dimensions. Unlike wedge-and-strip or resistive anode encoders, the delay line offers a spatial resolution that is relatively independent of the format length. Unlike discrete anode systems, the delay line readout system's complexity is also independent of the field of view size. These facts make the delay line readout system advantageous in large format detectors. A testbed detector having a delay line propagation speed of 2.2 mm/ns and a time resolution of 33 ps FWHM has been assembled. Ultraviolet testing shows a Gaussian event distribution having a 70-micron FWHM width; the readout system blur contribution is less than 50-micron FWHM.

Lampton, M.↗

Photon counting detectors for Fabry-Perot interferometers

Sealed channel plate photomultipliers with multiple discrete anodes for use as photon counting detectors in the image plane of Fabry-Perot interferometers are described. The influence of design and construction on performance of completed devices is discussed. Effects on spatial resolution, lifetime, and counting efficiency are described. It is shown that devices can be optimized for particular applications. The results should be generally applicable to resistive anode and wedge and strip anode types of sealed detectors.

Darlington, E. H.↗

Effects of anode materials on resistive characteristics of NiO thin films

This letter shows that the NiO-based structure with different anodes has different resistive switching properties. A conical conductive filament (CF) model is proposed for oxygen vacancies distributed in NiO films. Modeling analysis reveals much larger dissolution velocity of CF near anodes than near cathodes during the reset process. Different interfaces shown in Auger electron spectroscopy can be bound with the model to reveal that CF is dissolved in the structure with Pt or Au as anodes, while CF remains constant if the anode material is Ti or Al, which can explain whether switching properties occur in the specific NiO-based structures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In Situ and Surface-Enhanced Raman Spectroscopy Study of Electrode Materials in Solid Oxide Fuel Cells

Solid oxide fuel cells (SOFCs) represent next-generation energy sources with high energy conversion efficiencies, low pollutant emissions, good flexibility with a wide variety of fuels, and excellent modularity suitable for distributed power generation. As an electrochemical energy conversion device, the SOFC’s performance and reliability depend sensitively on the catalytic activity and stability of electrode materials. To date, however, the development of electrode materials and microstructures is still based largely on trial-and-error methods because of the inadequate understanding of electrode process mechanisms. Therefore, the identification of key descriptors/properties for electrode materials or functional heterogeneous interfaces, especially under in situ/operando conditions, may provide guidance for the design of optimal electrode materials and microstructures. Here, Raman spectroscopy is ideally suited for the probing and mapping of chemical species present on electrode surfaces under operating conditions. And to boost the sensitivity toward electrode surface species, the surface-enhanced Raman spectroscopy (SERS) technique can be employed, in which thermally robust SERS probes (e.g., Ag@SiO 2 core–shell nanoparticles) are designed to make in situ/operando analysis possible. Furthermore, this review summarizes recent progresses in the investigation of SOFC electrode materials through Raman spectroscopic techniques, including topics of early stage carbon deposition (coking), coking-resistant anode modification, sulfur poisoning, and cathode degradation. In addition, future perspectives for utilizing the in situ/operando SERS for investigations of other electrochemical surfaces and interfaces are also discussed.

25 ENERGY STORAGE↗

Electron spectroscopy using two-dimensional electron detection and a camera in a single electron counting mode

A brief description is given of an economical implementation of the read out of a two-dimensional detector in an electron spectrometer by a charge coupled device camera, using a pulse counting mode. Count rates up to 10 kHz can be handled in this way. A comparison with results obtained using a resistive anode detector is given for the case of electron scattering from Xe atoms. Good agreement was obtained between both detection techniques, establishing the validity of the method described here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗