Search NASA⌕ Search

SEARCH · Search NASA

Results for “Robustness analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A machine learning framework for accurate and robust analysis of radiation detector pulses

The microscopic properties of atomic nuclei are used to study various scientific questions. They are essential for understanding the fundamental forces of nature and the chemical evolution of the universe. Detecting decay radiation from radioactive nuclei makes it possible to probe these fundamental nuclear properties. Detector waveform traces may contain additional information about the radiation. Generally, advanced signal processing techniques are needed to extract this additional information, often involving fitting the waveform with model response functions using non-linear least-squares optimization with second-order gradient methods. While this is a powerful technique, it is also computationally expensive, leading to slow processing time, which scales with the volume of data. To address this problem, we have developed a machine learning (ML) approach that infers the characteristics of traces from a model detector response function. In particular, we are interested in classifying whether a single recorded trace consists of one or two pulse constituents and estimating the pulse parameters. Furthermore, our proposed ML method can precisely extract the pulses’ parameters, such as energy and timing information, and accurately classify the pulse multiplicity of a trace. Unlike non-learning-based approaches, our ML approach uses neural networks that are significantly faster at inference, as they do not require any optimization during this stage.

Curve fitting↗

Robust analysis of space-, time-, and energy-resolved soft x-ray measurements of magnetically confined fusion plasmas (invited)

A novel compact multi-energy soft x-ray (ME-SXR) diagnostic based on the PILATUS3 100K x-ray detector has been developed in collaboration between the Princeton Plasma Physics Laboratory and the University of Wisconsin-Madison and tested on the Madison Symmetric Torus (MST) reversed-field pinch. This solid-state photon-counting detector consists of a two-dimensional array of ~100 000 pixels for which the lower photon absorption cutoff energy can be independently set, allowing it to be configured for a unique combination of simultaneous spatial, spectral, and temporal resolution of ~1 cm, 100 eV, and 500 Hz, respectively. The diagnostic is highly versatile and can be readily adapted to diverse plasma operating conditions and scientific needs without any required downtime. New results from improved-confinement and quasi-single helicity plasmas in the MST demonstrate how the detector can be applied to study multiple aspects of the evolution of magnetically confined fusion-grade plasmas. These include observing the evolution of thermal emissivity, characterizing the energy of mid-Z excitation lines, extracting the T e profile, and observing the evolution of non-thermal populations. A technique for integrating the ME-SXR diagnostic into an integrated data analysis framework based on Bayesian inference is also presented. As a result, this allows ME-SXR measurements to be combined with data for complementary diagnostics in order to simultaneously infer Te and nZ from all available information.

47 OTHER INSTRUMENTATION↗

xCDAT: A Python Package for Simple and Robust Analysis of Climate Data

xCDAT (Xarray Climate Data Analysis Tools) is an open-source Python package that extends Xarray (Hoyer & Hamman, 2017) for climate data analysis on structured grids. xCDAT streamlines analysis of climate data by exposing common climate analysis operations through a set of straightforward APIs. Some of xCDAT’s key features include spatial averaging, temporal averaging, and regridding. These features are inspired by the Community Data Analysis Tools (CDAT) library (Dean N. Williams et al., 2009) (D. N. Williams, 2014) (Doutriaux et al., 2019) and leverage powerful packages in the Xarray ecosystem including xESMF (Zhuang et al., 2023), xgcm (Abernathey et al., 2022), and CF xarray (Cherian et al., 2023). To ensure general compatibility across various climate models, xCDAT operates on datasets that are compliant with the Climate and Forecast (CF) metadata conventions (Hassell et al., 2017).

54 ENVIRONMENTAL SCIENCES↗

Rational Optimization of Microbial Processing for High Yield CO 2 -to-Isopropanol Conversion: Cooperative Research and Development Final Report, CRADA Number CRD-20-17114

This project focuses on the production of the fuel blendstock isopropanol using a CO 2 -fixing Clostridium by metabolic engineering and process optimizations. The project will initiate from a baseline isopropanol producer and pursue isopropanol production at high carbon-conversion efficiency. We will lead engineering work by in-depth pathway analyses including thermodynamics optimization, enzyme expense analysis, metabolic robustness analysis, and -omics analysis. The isopropanol production will be optimized via genome editing followed by fermentation optimizations. This project will deliver a novel microbial process that efficiently converts waste CO 2 to isopropanol at ~g/L titer level within 18-months. This project will layout a solid knowledge basis and technology platform for renewable CO 2 valorization to bio-blendstock that help achieve Co-Optima and Shell's goals.

09 BIOMASS FUELS↗

Compressed baryon acoustic oscillation analysis is robust to modified-gravity models

Abstract We study the robustness of the baryon acoustic oscillation (BAO) analysis to the underlying cosmological model. We focus on testing the standard BAO analysis that relies on the use of a template. These templates are constructed assuming a fixed fiducial cosmological model and used to extract the location of the acoustic peaks. Such “compressed analysis” had been shown to be unbiased when applied to the ΛCDM model and some of its extensions. However, it has not been known whether this type of analysis introduces biases in a wider range of cosmological models where the template may not fully capture relevant features in the BAO signal. In this study, we apply the compressed analysis to noiseless mock power spectra that are based on Horndeski models, a broad class of modified-gravity theories specified with eight additional free parameters. We study the precision and accuracy of the BAO peak-location extraction assuming DESI, DESI II, and MegaMapper survey specifications. We find that the bias in the extracted peak locations is negligible; for example, it is less than 10% of the statistical error for even the proposed future MegaMapper survey. Our findings indicate that the compressed BAO analysis is remarkably robust to the underlying cosmological model.

Astronomy & Astrophysics↗

A robust statistical analysis of the role of hydropower on the system electricity price and price volatility

Abstract Hydroelectric power (hydropower) is unique in that it can function as both a conventional source of electricity and as backup storage (pumped hydroelectric storage and large reservoir storage) for providing energy in times of high demand on the grid (S. Rehman, L M Al-Hadhrami, and M M Alam), (2015 Renewable and Sustainable Energy Reviews , 44 , 586–98). This study examines the impact of hydropower on system electricity price and price volatility in the region served by the New England Independent System Operator (ISONE) from 2014-2020 (ISONE, ISO New England Web Services API v1.1 .” https://webservices.iso-ne.com/docs/v1.1/ , 2021. Accessed: 2021-01-10). We perform a robust holistic analysis of the mean and quantile effects, as well as the marginal contributing effects of hydropower in the presence of solar and wind resources. First, the price data is adjusted for deterministic temporal trends, correcting for seasonal, weekend, and diurnal effects that may obscure actual representative trends in the data. Using multiple linear regression and quantile regression, we observe that hydropower contributes to a reduction in the system electricity price and price volatility. While hydropower has a weak impact on decreasing price and volatility at the mean, it has greater impact at extreme quantiles (>70th percentile). At these higher percentiles, we find that hydropower provides a stabilizing effect on price volatility in the presence of volatile resources such as wind. We conclude with a discussion of the observed relationship between hydropower and system electricity price and volatility.

13 HYDRO ENERGY↗

Efficient and robust stability analysis in the internal energy, volume, and moles (UVN) space

Hydrodynamic simulation of fluids in vessels is often based on the internal energy (U), volume (V), and the number of moles of all components ( re N = N 1 , N 2 , ..., N n ) as the working variables to determine the thermodynamic state by finding the global maximum of entropy. The procedure of finding the equilibrium state may be divided into two steps: stability analysis and phase-split computations. Stability analysis is performed first, and the phase-split computation proceeds if the system is unstable. Most of the past work on UVN space has been based on phase-split computations, while the stability analysis is barely investigated. Furthermore, previous studies for the stability analysis use only Newton's method to solve the non-linear algebraic equations. We present an efficient and robust approach for stability analysis where UVN is specified. The successive substitution iteration (SSI) is used to provide good initial guesses for Newton's method. The proposed approach results in a reduced number of unknowns and does not require a large number of iterations to achieve convergence in Newton's method. Overall, our proposed formulation is compatible with different equations of state and is applicable to both pure component and multi-components. The robustness and efficiency of the algorithm for stability analysis are demonstrated in various examples.

02 PETROLEUM↗

A generalized computational framework to streamline thermodynamics and kinetics analysis of metabolic pathways

Metabolic engineering is a critical biotechnological approach in addressing global energy and environment challenges. Most engineering efforts, however, consist of laborious and inefficient trial-and-error of target pathways, due in part to the lack of methodologies that can comprehensively assess pathway properties in thermodynamics and kinetics. Metabolic engineering can benefit from computational tools that evaluate feasibility, expense and stability of non-natural metabolic pathways. Such tools can also help us understand natural pathways and their regulation at systems level. Here we introduce a computational toolbox, PathParser, which, for the first time, integrates multiple important functions for pathway analysis including thermodynamics analysis, kinetics-based protein cost optimization and robustness analysis. Specifically, PathParser enables optimization of the driving force of a pathway by minimizing the Gibbs free energy of least thermodynamically favorable reaction. In addition, based on reaction thermodynamics and enzyme kinetics, it can compute the minimal enzyme protein cost that supports metabolic flux, and evaluate pathway stability and flux in response to enzyme concentration perturbations. In a demo analysis of the Calvin-Benson-Bassham cycle and photorespiration pathway in the model cyanobacterium Synechocystis PCC 6803, the computation results are corroborated by experimental proteomics data as well as metabolic engineering outcomes. This toolbox may have broad application in metabolic engineering and systems biology in other microbial systems.

09 BIOMASS FUELS↗

Impedance Modeling for Mixed Conductors with Simultaneous Insertion & Electrocatalytic Reactions: A Case Study of Transition-Metal Hydroxides in Aqueous Electrolyte

Electrochemical impedance spectroscopy (EIS) is commonly used to investigate the kinetics of mixed ionic–electronic conductor (MIEC) electrodes. Across various applications, MIECs exhibit ionic (e.g., insertion) and/or electronic (e.g., electrocatalytic) charge transfer reactions at the electrode/electrolyte interface. Bulk storage and transport of charge carriers also couple with these interfacial reactions. Here, we build a generalized, physics-based impedance model for MIECs with an ion-blocking current collector and explore how bulk and interfacial resistance, chemical capacitance, and DC polarization affect the impedance response. Using transition metal hydroxides as a case study, we provide guidance on extracting reaction kinetics or bulk resistance from the Nyquist plots in interface- or bulk-controlled conditions, respectively. Generalizing our EIS analysis enables a robust analysis of MIEC kinetics for a diverse set of systems.

36 MATERIALS SCIENCE↗

Delving into the depths of NGC 3783 with XRISM II. Cross-calibration of X-ray instruments used in the large, multi-mission observational campaign

Context. Accurate X-ray spectroscopic measurements are fundamental for deriving basic physical parameters of the most abundant baryon components in the Universe. The plethora of X-ray observatories currently operational enables a panchromatic view of the high-energy emission of celestial sources. However, uncertainties in the energy-dependent calibration of the instrument transfer functions (e.g. the effective area, energy redistribution, or gain) can limit - and historically, did limit - the accuracy of X-ray spectroscopic measurements. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign.

Active Galactic Nuclei, individual: NGC 3783↗

Early Alarm: Robust Event Analysis for Power Systems using 1-D Fully Convolutional Network

This work presents a novel deep learning model for early, accurate, and robust detection, recognition, and temporal localization of multi-type events in large-scale power systems. The proposed method develops a unified 1-D fully convolutional network (FCN) model that takes time series of raw frequency signals measured from a power system as input, extracts distinguishing features, and predicts at every temporal point in the time series if an event is happening and what the type of the event is. Compared to existing methods, the proposed model eliminates the necessity for hand-crafted feature extraction or complicated data pre-processing, can flexibly handle input signals of arbitrary length, and precisely infer the event occurrence time. Most importantly, the model is intentionally trained with incomplete patterns, such that it is more robust to partial features of an event which is common in real-world online recognition, resulting in early alarm for power system failures. Extensive experimental results demonstrate that the proposed method achieves superior performance to the state-of-the-art, and also shows strong robustness to noise and system oscillations.

Li, Chengcheng↗

PathParser [SWR-19-54]

PathParser is a python-based computational tool for the thermodynamics and robustness analysis of native and designed metabolic pathways. The following functionalities are provided: 1 Max-min driving force (MDF) optimization. The Gibbs free energy change of the least favorable reaction will be maximized to evaluate thermodynamic feasibility of the entire pathway. 2 Protein cost estimation. The smallest enzyme investment will be assessed by calculating the minimal total enzyme cost supporting a given pathway flux. 3 Robustness analysis. Specifically, an ensemble of models is generated to simulate the system response to enzyme perturbation based on bifurcation theory and a continuation method. Probability of system failure and flux fold change against enzyme perturbation are estimated as well as a flux control index.

Xiong, Wei↗

COVID-19 biomarkers based on respiratory microbiome content

COVID-19 patient care management would greatly benefit from new tools that enable accurate assessment of disease severity and stage, potentially enabling a personalized medicine approach. Detection of the SARS-CoV-2 virus itself, or even quantitation of viral loads, is not sufficient for accurate assessment of disease state beyond diagnosis of infection [eg, doi:10.1093/cid/ciaa344]. Levels of usual suspect protein biomarkers associated with host response to infection [eg, C-reactive protein (CRP); cytokines like IL-6, TNF-alpha, and IL-10; complement proteins like C3a and C5a], and of individual blood cell types (eg, leukocytes, lymphocytes, and subsets thereof), show limited correlation with disease severity and stage, with high patient-to-patient and study-to-study variability [eg, doi:10.1093/cid/ciaa248]. High-dimensional panels of biomarkers should have greater predictive power and resilience to unavoidable sources of variability; however, their assembly from proteins and cell types is extremely difficult, due to technical limitations in analyte measurement, especially with regard to starting material requirements and detection sensitivity. Host response profiling through Next Generation Sequencing (NGS) of gene expression patterns (ie, RNA-Seq) is a promising approach, but at the time of this project there were only two publicly available datasets of relevance [doi:10.1093/cid/ciaa203, doi:10.1080/22221751.2020.1747363], and close inspection of them revealed that each had at least one major flaw that severely undermined its value in supporting robust analysis of host response to SARS-CoV- 2 infection. However, the first of these studies [doi:10.1093/cid/ciaa203] fortuitously collected NGS data not only from host cells, but also from bacteria present in bronchoalveolar lavage fluid (BALF) recovered from COVID-19 patients; and because the respiratory microbiome (in terms of bacterial species content) is far less complex than the human transcriptome, the NGS data collected were sufficient to provide coverage depth supporting robust analysis. Surprisingly, the authors of the study did not carry out a detailed analysis of these data and their potential for revealing important new information about COVID-19. Therefore, we carried out a meta-analysis of the dataset as a first step in evaluating the potential for profiling of respiratory microbiome dynamics as a means of accurately assessing COVID-19 disease state.

59 BASIC BIOLOGICAL SCIENCES↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗