Design and development of the magnetic diagnostic systems for the first operational phase of the SMART tokamak

A set of magnetic diagnostics has been designed, manufactured, and calibrated for the first operational phase of the small aspect ratio tokamak. The sensor suite comprises of Rogowski coils; 2D magnetic probes; and poloidal, saddle, and diamagnetic flux loops. Here, a set of continuous Rogowski coils has been manufactured for the measurement of plasma current and induced eddy currents in conductive elements. A set of flux loops and magnetic probes will be used as input for the reconstruction of the magnetohydrodynamic equilibrium. The quantity and position of these sensors have been verified to be sufficient with synthetic equilibrium reconstructions using the equilibrium fitting code and baseline scenarios computed with the Fiesta code. These sensors will also be used as input for the real-time control system, and magnetic probes will be used for the detection of plasma instabilities. The calibration procedure for the magnetic probes is described, and the results are shown. The signal conditioning and data acquisition systems are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Medium-Voltage Testbed for Comparing Advanced Power Line Sensors vs. Measurement Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medi-um-voltage sensor is compared with a reference PT and CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the US De-partment of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with integrator for current monitoring. The advanced outdoor power line sensor testbed has a real-time simulator that was used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, service restoration), while the analog signals were recorded by the same high resolution power meter. The behavior of analog signals, harmonic components, total harmonic distortion, and crest factors were assessed for this power line sensor compared with the reference PT/CT, because of the absence for testing standards for advanced outdoor power line sensors.

Piesciorovsky, Emilio↗

Benchmarking the Suitability of Novec$^{\mathrm{TM}}$ 4710 for Application in Flux Compression Generators

Here, an experimental study evaluated the feasibility of replacing traditional insulating gases such as SF 6 with C 4 F 7 N (3M TM , Novec 4710) in flux compression generator (FCG) applications. Currently available data indicate that Novec 4710 could offer certain performance benefits over SF 6 . However, the available literature is focused on low frequency (50–60 Hz) and dc at static pressures. To evaluate the performance of Novec 4710 under the pulsed dynamic pressure and temperature conditions found in an FCG, we report a performance comparison between three sets of identical FCGs using air, SF 6 , and Novec 4710 as the insulating gas. The generators used in this study had a single stage, directly seeded design with an armature diameter of 25 mm and a stator diameter of 46 mm. To highlight the performance of the different gases rather than any wire insulation, the stator was constructed with uninsulated wire. Furthermore, the generators were seeded aggressively, making the performance difference between the different gases more apparent. The performance was monitored with a pair of differential Rogowski coils that captured the generators’ di / dt while also using high-speed videography to capture possible gaseous breakdown signatures. The data gathered during this study indicate that Novec 4710 performs at least as well as SF 6 in FCG applications, if not significantly better.

42 ENGINEERING↗

Highly Integrated Wide Bandgap Power Module for Next Generation Plug-In Vehicles (Final Report)

Wide bandgap devices are key enablers for high power density traction inverters. A highly integrated wide bandgap (WBG) power module enables higher temperature operation, higher inverter efficiency and overall smaller die area with the same power delivery. However, it requires careful design of the power module to take advantage of all the superior material properties that silicon carbide (SiC) provides over conventional silicon (Si) Insulated Gate Bipolar Transistor (IGBT) based design. This project developed an efficient and densely packed SiC power module for an automotive traction inverter application. Extensive study was performed to select the best performing SiC die considering a wide range of temperature variation, suitability to integrate into target packaging, robust body diode performance and overall high electrical efficiency. Multiple design ideas were explored to achieve lower stray inductance for both power loop and signal loop, uniform current distribution, compact form factor, and very high thermal performance. The final power module package includes all six inverter switches in the same module (six-pack) with die sintered at both bottom and top surfaces utilizing high performance substrate to achieve high electrical and thermal performance. Two power module variants were developed using 900 V and 1200 V devices for operating at two different high voltage levels (> 600 V HV battery). Both power modules were comprehensively characterized, and high efficiency operation of the inverter was confirmed through analysis. Finally, a complete functional inverter was built with the 1200V power modules using other essential components (HV capacitors, gate driver board, controller board, current sensor, connectors etc.) and tested using GM’s standard test procedure. There are several challenges associated with adopting WBG devices for high voltage operation. In order to assess and mitigate those challenges, GM and subrecipients of this project have conducted multiple detailed studies. This includes phase current reconstruction using integrated Rogowski coil, device junction temperature estimation using on-state gate resistance, modeling and testing the effect of high voltage and fast switching on motor insulation and bearings, partial discharge inception voltage measurement under different environmental conditions. Findings of all these studies are summarized in this report.

33 ADVANCED PROPULSION SYSTEMS↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Distributed, Intelligent Edge-Sensing for a Smarter Grid

The electric grid is undergoing major transformations and developments resulting in unprecedented levels of volatility, uncertainty, and stress on grid infrastructure. Smart sensors and methods aiding in advanced visibility and situational awareness are key for tackling these issues. In this work, a decentralized architecture is proposed, where sensing, local computation and control capability are embedded in the edge devices, communicating with a set of trusted 'data mules' in a 'delay-tolerant' manner, while functioning autonomously. This system has been designed and implemented as an overall platform – called Global Asset Monitoring, Management and Analytics (GAMMA) Platform intended to provide the backbone for a global array of sensors and actuators. Further, as a building block for advanced current sensing solutions, a smart, low-cost ‘clip-on’ current sensor based on PCB-embedded Rogowski coil has been developed. The sensor hosts a novel signal conditioning stage allowing an 'auto-tuning' feature, resulting in a universal current sensor design for measuring a wide range of currents, including faults for smart grid applications. Finally, the research proposes a method to instrument and monitor key parameters for the most common electric utility asset – the pole-top distribution transformer. The work done in this research enables scalable, edge-intelligent sensing solutions for monitoring grid infrastructure, allowing utility operators to gain advanced visibility in an economical way.

Kulkarni, Shreyas Bhalchandra↗

A magnetic diagnostic suite for the Pegasus-III experiment

Pegasus-III is an ultralow aspect ratio spherical tokamak providing a dedicated US experiment for comparative solenoid-free startup studies. A new magnetic diagnostic suite for equilibrium and low frequency (<200 kHz) magnetohydrodynamic mode analysis has been installed. These new diagnostics address the significant challenges of measuring magnetic field in a high noise environment with the majority constrained to fit in an 8 mm diagnostic gap on the high field side. Electrostatic switching noise generated by the 16 independent current feedback-controlled power supplies produces dV cm /dt ~ 1 kV/μs and volt level common mode noise on the magnetics. Immunity to this switching noise is accomplished through differential signal runs and signal processing, along with end-to-end electromagnetic interference shielding. The magnetic measurements are simultaneously digitized at 1 MHz and conditioned by precision 8 pole Butterworth filters with a corner frequency of 200 kHz to prevent aliasing down to the 16-bit level over the full passband. Ex-vessel calibrations of the B p coils were completed with a typical uncertainty of <0.5%. Stray toroidal field pickup from coil misalignment or positioning errors is corrected using a physics-based model. Comparisons of the corrected measurements to modeling agree to within 1.3% on average. This is within the 1.5% measurement uncertainty that a sensitivity analysis determined is needed for accurate fast boundary and equilibrium reconstruction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Liner implosion experiments driven by a dynamic screw pinch

This paper expands upon recent experimental results [Campbell et al., Phys. Rev. Lett. 125, 035001 (2020)], where thin-foil liner implosions were driven by a dynamic screw pinch (DSP) and found to have magneto-Rayleigh–Taylor instability (MRTI) amplitudes up to three times smaller than in implosions driven by a standard z-pinch (SZP). Here, the expanded discussion presented herein includes: (1) a detailed comparison of the MRTI growth measured in the experiment with that calculated from theory; (2) measurements of axial magnetic field injection into the liner interior prior to the implosion, as well as the subsequent compression of this field during the implosion; (3) an in-depth description of how the helical geometry of the DSP can result in earlier implosion and stagnation times relative to the SZP; and (4) particle-in-cell simulations showing different electron drift behavior in the anode–cathode gap of the DSP relative to the SZP, and how this difference may be related to the different current waveforms recorded during the experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiframe point-projection radiography imaging based on hybrid X-pinch

This paper demonstrates the possibility of using a new configuration of the hybrid X-pinch to produce a set of spatially and temporarily separate x-ray bursts that could be used for the radiography of dynamic events. To achieve this, a longer than normal wire is placed between the conical electrodes of the hybrid X-pinch, and a set of small spacers (fishing weights) is placed along the wire. Each subsection of the wire then acts as a unique X-pinch, producing its own radiation burst from a small (~3 µm) spot. The timing between bursts is 20–50 ns, and each is <2 ns in duration. For comparison, if a longer wire is simply employed without spacers, hotspots of radiation occur in random positions and the time between any two bursts does not exceed 20 ns. Examples of two and three frame point-projection radiography of solid-state and plasma test objects are given.

47 OTHER INSTRUMENTATION↗

Measuring characteristic differences between high- and low-performing discharges on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF

A dense plasma focus (DPF) is a compact coaxial plasma gun, which completes its discharge as a Z-pinch, producing short (<100 ns) pulses of ions, x rays, and/or neutrons. Lawrence Livermore National Laboratory recently constructed and began operating a new device, the MJOLNIR (MegaJOuLe Neutron Imaging Radiography) DPF, which is designed for single-pulse flash neutron radiography. This device has achieved neutron yields of up to 4.1×10 11 neutrons/pulse at 3.3 MA peak current, and higher-current commissioning is under way. Like most DPFs, MJOLNIR exhibits variable yields in some configurations. Here, we present evidence of the role of parasitic current paths within the gun in stochastically influencing the yield. First through “conditioning shots,” where new hardware has been introduced, we show that increased run-down and run-in speeds correlate with higher yields. These observations are consistent with current being delivered to the electrodes but not to the main plasma sheath, degrading the implosion-driving force. Once nominal conditions are established, we correlate low-performing discharges with smaller current dip and associated voltage spike for a fixed machine configuration. A snow-plow model is able to recreate small-magnitude current dips through the introduction of a parasitic current path, and particle-in-cell simulations establish how parasitic current paths lower the ion beam energy available to produce neutrons. Finally, we observe an increased likelihood of shots with low yield and smaller current dip with increasing fill pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Explosion dynamics of thin flat foils at high current density

This paper presents characteristic features of the explosion of thin flat foils for currents and pulse risetimes ranging from 8 kA at 350 ns to 1000 kA at ~100 ns. Foils made of aluminum, copper, nickel, and titanium with thicknesses of 1–100 µm are tested. Various diagnostics in the optical, UV, and x-ray spectral ranges are used to image the exploding foils from initial breakdown to complete destruction or pinching. It is shown that foil explosion is a complex process that depends on many factors, but features common to all foils are found that do not depend on the parameters of the generators or, accordingly, on the energy deposited in the foil: for example, the breakdown of flat foils under different conditions occurs at the edges of the foil. For the first time, the formation of a precursor over the central part of the foil is shown, which significantly changes the dynamics of the foil explosion.

36 MATERIALS SCIENCE↗

Achieving stationary high performance plasmas at Wendelstein 7-X

This work reports on recent results on the search for high performance plasma scenarios at the magnetically confined stellarator fusion device Wendelstein 7-X. In four new designed scenarios, the development from transient toward stationary plasmas of improved performance has been realized. In particular, a high performance duration of up to 5 s, an energy confinement time of 0.3 s, a diamagnetic energy of 1.1 MJ, a central ion temperature of 2.2 keV, and a fusion triple product of 3.4 x 10 19 m -3 ∙ keV ∙ s have been achieved, and previously observed limitations of the machine have been overcome, regarding both the performance and its duration. The two main experimental techniques for stationary high performance are neutral beam injection core fueling on the one hand and the use of a magnetic field configuration with internal islands on the other hand. Two of the developed scenarios are expected to be extendable straightforward toward a duration of several tens of seconds, making use of the long pulse operation capabilities of W7-X.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanosecond Breakdown Characteristics of C 4 F 7 N and Various Mixtures at Pressures Above 1 Atmosphere in Comparison with SF 6

This report evaluates the pulsed breakdown performance of C 4 F 7 N under a 6.8 kV/ns voltage excitation. The pulsed dielectric strength of C 4 F 7 N is compared to SF 6 in the same experimental setup, and it is found that C 4 F 7 N concentrations of 50% or greater are required to achieve a dielectric strength greater than or equal to SF 6 . Pure C 4 F 7 N demonstrated higher electric field hold-off for longer time periods and less statistical variance under pulsed conditions when compared to SF 6 . Mixtures of 50%C 4 F 7 N with N 2 or CO 2 as buffer gases showed no appreciable difference in pulsed dielectric strength.