Search NASA⌕ Search

SEARCH · Search NASA

Results for “Roofing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Effects of Solar Photovoltaic Panels on Roof Heat Transfer

Building Heating, Ventilation and Air Conditioning (HVAC) is a major contributor to urban energy use. In single story buildings with large surface area such as warehouses most of the heat enters through the roof. A rooftop modification that has not been examined experimentally is solar photovoltaic (PV) arrays. In California alone, several GW in residential and commercial rooftop PV are approved or in the planning stages. With the PV solar conversion efficiency ranging from 5-20% and a typical installed PV solar reflectance of 16-27%, 53-79% of the solar energy heats the panel. Most of this heat is then either transferred to the atmosphere or the building underneath. Consequently solar PV has indirect effects on roof heat transfer. The effect of rooftop PV systems on the building roof and indoor energy balance as well as their economic impacts on building HVAC costs have not been investigated. Roof calculator models currently do not account for rooftop modifications such as PV arrays. In this study, we report extensive measurements of a building containing a flush mount and a tilted solar PV array as well as exposed reference roof. Exterior air and surface temperature, wind speed, and solar radiation were measured and thermal infrared (TIR) images of the interior ceiling were taken. We found that in daytime the ceiling surface temperature under the PV arrays was significantly cooler than under the exposed roof. The maximum difference of 2.5 C was observed at around 1800h, close to typical time of peak energy demand. Conversely at night, the ceiling temperature under the PV arrays was warmer, especially for the array mounted flat onto the roof. A one dimensional conductive heat flux model was used to calculate the temperature profile through the roof. The heat flux into the bottom layer was used as an estimate of the heat flux into the building. The mean daytime heat flux (1200-2000 PST) under the exposed roof in the model was 14.0 Watts per square meter larger than under the tilted PV array. The maximum downward heat flux was 18.7 Watts per square meters for the exposed roof and 7.0 Watts per square meters under the tilted PV array, a 63% reduction due to the PV array. This study is unique as the impact of tilted and flush PV arrays could be compared against a typical exposed roof at the same roof for a commercial uninhabited building with exposed ceiling and consisting only of the building envelope. Our results indicate a more comfortable indoor environment in PV covered buildings without HVAC both in hotter and cooler seasons.

Dominguez, A.↗

Feasibility of determining flat roof heat losses using aerial thermography

The utility of aerial thermography for determining rooftop heat losses was investigated experimentally using several completely instrumented test roofs with known thermal resistances. Actual rooftop heat losses were obtained both from in-situ instrumentation and aerial thermography obtained from overflights at an altitude of 305 m. In general, the remotely determined roof surface temperatures agreed very well with those obtained from ground measurements. The roof heat losses calculated using the remotely determined roof temperature agreed to within 17% of those calculated from 1/R delta T using ground measurements. However, this agreement may be fortuitous since the convective component of the heat loss is sensitive to small changes in roof temperature and to the average heat transfer coefficient used, whereas the radiative component is less sensitive. This, at this time, it is felt that an acceptable quantitative determination of roof heat losses using aerial thermography is only feasible when the convective term is accurately known or minimized. The sensitivity of the heat loss determination to environmental conditions was also evaluated. The analysis showed that the most reliable quantitative heat loss determinations can probably be obtained from aerial thermography taken under conditions of total cloud cover with low wind speeds and at low ambient temperatures.

Bowman, R. L.↗

The Successful Transfer of Space Derived Convergent Spray: An Application for Industrial Roof Coatings and Interstate Bridge Repair

A partnership was formed between the National Aeronautics and Space Administration (NASA), the Environmental Protection Agency (EPA), and United Technologies USBI Company to develop, demonstrate, and evaluate a technology that uses a solventless spray process for depositing a lightweight, highly filled roof coating on low-sloped commercial roofs. Although the levels of volatile organic compound (VOC) emissions from industrial roof coating's and paint operations have been reduced in recent years, this partnership,was an effort to further reduce VOC emission levels and to also demonstrate the use of reclaimed automobile tire rubber as a filler material in roof coating systems. Different materials and coatings were evaluated and tested before the final selection used to coat the roofs of two small buildings at NASA's Marshall Space Flight Center during fiscal year 1997. The project successfully leveraged the investment of EPA, NASA and private sector resources to demonstrate a pre-commercial roofing coating process. This process utilizes the Convergent Spray Technologies process, which was initially developed by USBI to apply highly-filled, thermal protection coatings to the Space Shuttle Solid Rocket Boosters. A second partnership between the NASA, Federal Highway Administration, Alabama Department of Transportation and USBI Company was formed to develop and demonstrate the Convergent Spray Technology as a method of applying a skid resistant coating to interstate roads and concrete bridge decking's. Again, different materials and coatings were evaluated and tested before the final selection of ground flint and resin. Two field demonstrations were performed during fiscal year 1997 for the purpose of evaluating the coating system under actual highway conditions. These coatings were applied on Interstate 65 near Huntsville Alabama, and in the Mobile Bankhead tunnel. The system performed this task without the use of harmful solvents, and accomplished the process in a single application. This project successfully leveraged the investment of NASA, Federal Highway Administration, the Alabama Department of Transportation, and private sector funding.

McMillan, Vernotto C.↗

Feasibility of determining flat roof heat losses using aerial thermography

The utility of aerial thermography for determining rooftop heat losses is investigated. Actual rooftop heat losses were obtained both from in-situ instrumentation of test roofs with known thermal resistances and aerial thermography obtained from overflights at an altitude of 305 m. It is found that the roof heat losses calculated using the remotely determined roof temperature agreed to within 17% of those calculated from ground measurements. However it is noted that an acceptable quantitative determination of roof heat losses using aerial thermography is only feasible when the convective term is accurately known or minimized. In addition, the sensitivity of the heat loss determination to environmental conditions is also evaluated. Finally, the analysis shows that the most reliable determinations can probably be obtained under conditions of total cloud cover with low wind speeds and at low ambient temperatures.

Bowman, R. L.↗

The Successful Transfer of Space Derived Convergent Spray Technology(TM): An Application for Industrial Roof Coatings and Interstate Bridge Repair

Although the levels of volatile organic compound (VOC) emissions from industrial roof coatings and paint operations have been reduced in recent years, the roof coating partnership was an effort to further reduce VOC emission levels and to also demonstrate the use of reclaimed automobile tire rubber as a filler material in roof coating systems. Different materials and coatings were evaluated and tested before the final selection was used to coat the roofs of two small buildings at NASA's MSFC (Marshall Space Flight Center) during fiscal year 1997. The primary objective of the Bridge repair partnership was to strategically leverage public and private sector funds for the purpose of developing a bridge repair process that was cheaper, better, and faster than conventional methods. It was also, imperative that this process be environmentally friendly and capable of performing under extreme conditions for a period of not less than 2 years.

McMillan, Vernotto↗

Bright is the New Black - Multi-Year Performance of Generic High-Albedo Roofs in an Urban Climate

High-albedo white and cool roofing membranes are recognized as a fundamental strategy that dense urban areas can deploy on a large scale, at low cost, to mitigate the urban heat island effect. We are monitoring three generic white membranes within New York City that represent a cross-section of the dominant white membrane options for U.S. flat roofs: (1) an ethylene propylene diene monomer (EPDM) rubber membrane; (2) a thermoplastic polyolefin (TPO) membrane and; (3) an asphaltic multi-ply built-up membrane coated with white elastomeric acrylic paint. The paint product is being used by New York City s government for the first major urban albedo enhancement program in its history. We report on the temperature and related albedo performance of these three membranes at three different sites over a multi-year period. The results indicate that the professionally installed white membranes are maintaining their temperature control effectively and are meeting the Energy Star Cool Roofing performance standards requiring a three-year aged albedo above 0.50. The EPDM membrane however shows evidence of low emissivity. The painted asphaltic surface shows high emissivity but lost about half of its initial albedo within two years after installation. Given that the acrylic approach is an important "do-it-yourself," low-cost, retrofit technique, and, as such, offers the most rapid technique for increasing urban albedo, further product performance research is recommended to identify conditions that optimize its long-term albedo control. Even so, its current multi-year performance still represents a significant albedo enhancement for urban heat island mitigation.

Gaffin, S. R.↗

Relationship of roof falls in underground coal mines to fractures mapped on ERTS-1 imagery

ERTS imagery is of unique value for mapping of certain fractures that are not identifiable on aircraft imagery. Because color infrared and ERTS imagery complement each other both sources of data were used to map fractures in western Indiana and eastern Illinois. In the Kings Station Mine, Gibson County, Indiana, most roof falls reported had occurred in areas where mapped fractures were closely spaced and intersecting. Using this information as a basis for extrapolation, roof fall hazard maps were prepared for other mine sites. Various coal resources programs related to energy and environment also were conducted.

Wier, C. E.↗

The application of photovoltaic roof shingles to residential and commercial buildings

The recent development of a shingle-type solar-cell module makes it possible to incorporate easily photovoltaic power generation into the sloping roofs of residential or commercial buildings. These modules, which use a closely packed array of nineteen 53-mm-diameter circular solar cells, are capable of producing 101 watts/sq m of module area under standard operating conditions. This module performance is achievable by the use of solar cells with an average efficiency of 13.3 percent at 1 kW/sq m air-mass-1.5 insolation and at a cell temperature of 28 C. When these modules are mounted on a sloping south-facing roof which is insulated on the rear surface, the annual energy generated at the maximum power operating point will vary from 255.6 to 137.3 kWh/sq m of module area depending on the site location, with Albuquerque, NM, and Seattle, WA, representing the highest and lowest values of the thirteen sites considered.

Shepard, N. F., Jr.↗

Photovoltaic Roofs

Solar cells perform two functions: waterproofing roof and generating electricity. Sections through horizontal and slanting joints show overlapping modules sealed by L-section rubber strips and side-by-side modules sealed by P-section strips. Water seeping through seals of slanting joints drains along channels. Rooftop photovoltaic array used watertight south facing roof, replacing shingles, tar, and gravel. Concept reduces cost of residential solar-cell array.

Drummond, R. W., Jr.↗

A Roof for the Lion's House

Fans of the National Football League's Detroit Lions don't worry about gameday weather. Their magnificent new Pontiac Stadium has a domed, air-supported, fabric roof that admits light but protects the playing field and patrons from the elements. The 80,000-seat "Silverdome" is the world's largest fabric-covered structure-and aerospace technology played an important part in its construction. The key to economical construction of the Silverdome-and many other types of buildings-is a spinoff of fiber glass Beta yarn coated with Teflon TFE fluorocarbon resin. The big advance it offers is permanency. Fabric structures-tents, for example have been around since the earliest years of human civilization. But their coverings-hides, canvas and more recently plastics-were considered temporary; though tough, these fabrics were subject to weather deterioration. Teflon TFE-coated Beta Fiberglas is virtually impervious to the effects of weather and sunlight and it won't stretch, shrink, mildew or rot, thus has exceptional longevity; it is also very strong, lightweight, flame resistant and requires no periodic cleaning, because dirt will not stick to the surface of Teflon TFE. And to top all that, it costs only 30 to 40 percent as much as conventional roofing.

Source record↗

Evaluation of Convergent Spray Technology(TM) Spray Process for Roof Coating Application

The overall goal of this project was to demonstrate the feasibility of(CST) Convergent Spray Technology (Trademark) for the roofing industry. This was accomplished by producing an environmentally compliant coating utilization recycled materials, a CST(Trademark) spray process portable application cart, and hand-held applicator with a CST(Trademark) spray process nozzle. The project culminated with application of this coating to a nine hundred sixty square foot metal for NASA Marshall Space Flight Center (MSFC) in Huntsville, Alabama.

COATINGS↗

Solar power roof shingle

Silicon solar cell module provides both all-weather protection and electrical power. Module consists of array of circular silicon solar cells bonded to fiberglass substrate roof shingle with fluorinated ethylene propylene encapsulant.

Forestieri, A. F.↗

A steering law for a roof-type configuration for a single-gimbal control moment gyro system

Single-Gimbal Control Moment Gyro (SGCMG) systems have been investigated for attitude control of the Large Space Telescope (LST) and the High Energy Astronomy Observatory (HEAO). However, various proposed steering laws for the SGCMG systems thus far have some defects because of singular states of the system. In this report, a steering law for a roof-type SGCMG system is proposed which is based on a new momentum distribution scheme that makes all the singular states unstable. This momentum distribution scheme is formulated by a treatment of the system as a sampled-data system. From analytical considerations, it is shown that this steering law gives control performance which is satisfactory for practical applications. Results of the preliminary computer simulation entirely support this premise.

Yoshikawa, T.↗

The detection of the coal roof interface by use of high pressure water

A device whereby water jets can be used to detect the interface between coal and the overlying roof rock is described. Once this identification is made this distance can be measured using instruments such as the autofocus systems recently developed in the photographic industry. Experiments carried out show that the device can discriminate between coal and rock at coal thicknesses up to 8 inches. An autofocus system was examined which indicates accuracies of better than 0.1 inches.

Source record↗

Roof Support Near Coal-Mining Face

Hydraulically-powered legs mounted on crawlers and carrying sections of conveyors provide roof support close to working face and above workspace at all times.

Knurovsky, T.↗

Roof Polishing of Optical Fibers

Bevealed tip gives optimum coupling efficiency. Abrasive tape used to grind tip of optical fiber. Grinding force depends on stiffness of optical fiber. "Roof" shape on end of optical glass fiber increases efficiency which couples laser light. End surface angle of 65 degrees with perpendicular required for optimum coupling. Since fiber and tape are light in weight and compliant, ridge defect-free, and chipping on fiber edge totally eliminated.

Dholakia, A. R.↗