Search NASA⌕ Search

SEARCH · Search NASA

Results for “Roofing Integrated Solar”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

High efficiency translucent solar module integrated with greenhouse roof structures

A translucent solar module assembly for integration with a greenhouse having a frame with a plurality of roof supports includes a pair of brackets attachable to each of the plurality of roof supports, a bi-facial solar panel attachable to the pair of brackets, and a pair of reflector rails attachable to each of the plurality of roof supports. A dichroic reflector is attachable to the pair of reflector rails.

Pan, Wei↗

Next Generation Integrated PV Products Cost and Workflow Analysis (Final Report)

Residential photovoltaic (PV) costs have fallen consistently for over a decade (Ardani et al. 2018). DOE has subsequently developed a new residential PV cost target for 2030 of $0.05/kilowatt hour (SETO 2023). Ardani et al. (2018) conclude that integrated roofing and PV (RIPV) products may be key to achieving the residential target for both new construction and retrofit residential PV. In RIPV, the PV product is incorporated into or replaces the roofing material. RIPV systems can use conventional crystalline or thin-film technologies, may be aesthetically attractive alternatives to traditional racked and mounted PV systems, and may increase building property values (Cook et al. 2023). These products also have the potential to provide customer acquisition, labor, and equipment cost savings over traditional, racked and mounted residential rooftop PV and several companies have recently introduced integrated roofing and PV (RIPV) products (Cook et al. 2023). In 2022, Tesla was the market leader, representing 94% of RIPV capacity installed in 2022 through its Solar Roof offering, while GAF Energy and its Timberline Solar product was second capturing 3% (Feldman et al. 2023). In this project, NREL analyzed three research questions: (1) How do current RIPV products compare to racked and mounted PV in terms of costs, install times and processes? (2) How are RIPV products installed and are there opportunities for cost savings? (3) What are the key barriers to expanding market opportunities for integrating solar and roofing products? In this project, we explored residential RIPV cost reduction opportunities by analyzing installation processes. Our study documented residential RIPV installations at two reroofing sites (20.52 kilowatts) and the equivalent of nine new construction sites (71.75 kW) in California through a methodology known as time and motion study. We also conducted 15 interviews with subject-matter experts to identify barriers and solutions to maximize these products' market penetration.

14 SOLAR ENERGY↗

Observations and Lessons Learned From Installing Residential Roofing-Integrated Photovoltaics

Building-sited solar photovoltaics (PV) could play a key role in decarbonizing the building sector either through racked and mounted PV or through Building-integrated PV (BIPV). BIPV is installed into the building envelope itself, with solar cells and/or modules forming the outer layer of a building structure, thus transforming a single-purpose structure into one that serves the dual purposes of the building envelope and electricity. BIPV can be applied to building roofs, facades, awnings, pergolas, windows, skylights, balustrades, and other external surfaces. Given BIPV products vary widely, the focus of this research is residential roofing integrated PV (RIPV), where solar is incorporated into or otherwise replaces the roofing material. Previous research suggests that residential RIPV could reduce customer acquisition, labor, supply chain, and equipment costs. These products have yet to realize these cost savings and deployment remains significantly less than conventional rooftop PV as a relative share of the addressable market in the US. One potential barrier to broader residential roofing integrated PV deployment may be higher costs relative to conventional rooftop PV, primarily because the design and installation of these products is still evolving. Here, we explore residential RIPV cost-reduction opportunities by analyzing installation processes. Our study documents residential RIPV installations at 2 reroofing sites and the equivalent of 9 new construction sites in California through a methodology known as time and motion study. We also conducted interviews with subject-matter experts to identify barriers and solutions to maximize these products' market penetration. Our time and motion study breaks the RIPV installation process into four steps: 1) staging, unloading, and roof preparation; 2) fire resistant underlayment(s) (synthetic material laid between roof shingles and roof deck); 3) flashings and PV installation; and 4) wiring and monitoring. We measure the time required for each step in terms of worker-hours, representing an hour of labor from a single worker. We further normalize process time by dividing worker-hours by kilowatt (kW) of system capacity. The most time-intensive step was flashings and PV installation, taking around 2.4 worker-hours per kW on average and accounting for around 60% of the process time for an average installation. The total installation process took on average about 6.4 and 3.5 worker-hours per kW at the reroofing sites and new construction sites, respectively. For comparison, a previous time and motion study documented a time of 6.9 worker-hours per kW for conventional rooftop PV. The shorter RIPV installation times are consistent with previous studies suggesting that RIPV could be installed faster than conventional rooftop PV. The time and motion results and feedback from interviewees provide insights into potential residential RIPV cost reduction opportunities. Several interviewees suggested that these products would be more efficient if PV installation was more fully integrated into the roofing/construction industries, which currently use separate supply chains and skillsets. Further integration could reduce supply chain delays and labor force redundancies. Future research could explore specific ways to integrate these industries to help realize the cost savings potential of RIPV.

14 SOLAR ENERGY↗

Building with integral solar-heat storage--Starkville, Mississippi

Column supporting roof also houses rock-storage bin of solar-energy system supplying more than half building space heating load. Conventional heaters supply hot water. Since bin is deeper and narrower than normal, individual pebble size was increased to keep airflow resistance at minimum.

Source record↗

Observations and Lessons Learned in Residential Roofing Integrated Photovoltaics

The data file includes field observations of residential roofing integrated photovoltaics installation that happened between July 2021 and June 2022 in California. There are 21 observations - 2 in the re-roofing category and 19 in the new construction category. The file includes two time and motion forms (Re-Roofing & New Construction) we used to capture the time it takes for each activity in the rooftop solar and electrical installation process. You will see the duration for detailed steps along with activities that are included for total installation time for the paper. There are three parts to the time and motion form - Part 1 has project and crew characteristics, product information, and inspection and permitting data and can be filled before the installation. Part 2 has the actual installation time stamps and related notes. Part 3 has the crew information and can be filled on-site or off-site, but this section is optional. The re-roofing form has pre-solar activities and gutters and vents section in Part 2 of the form, whereas new construction form includes a section for capturing the time it took for rough wiring. The re-roofing form does not include rough wiring but instead includes the final electrical wiring process. These are the key differences in both the forms. Each day/step/installation activity needs to include the crew break time as they happen and there is space available to capture the crew breaks duration. In Table 1 below, the different terms used in the time and motion form are defined and their corresponding unit of measurement stated. We also highlight the optional sections. The data is captured in total mins, total hours, person mins, person hours. You can use this form or make edits to the form to recreate the study or make your own observations. The data herein was reviewed but may not be comprehensive. NREL invites questions and inputs to improve the data, including to: Correct erroneous information Fill in missing/updated information Clarifications on data and variables Updated information may be submitted to Sushmita Jena at sushmita.jena@nlr.gov.

14 SOLAR ENERGY↗

Satellite Beach Energy - Restructuring the Energy Balance in Satellite Beach, Florida, by Quantifying Solar Energy Production Potential using NASA POWER Data Products and LiDAR

The City of Satellite Beach, Florida, has committed to supplying 100% of its energy use from renewable energy, primarily solar, by the year 2050. The team created a methodology for estimating rooftop solar power potential using a high-resolution Light Detection and Ranging (LiDAR) dataset and the NASA Prediction of Worldwide Energy Resources (POWER) dataset to assist Satellite Beach in reaching their solar renewable energy goals. The POWER dataset provides information on direct and diffuse solar irradiation on horizontal surfaces, surface albedo, and effects of local meteorology, such as clouds. The team integrated the solar irradiance data with the LiDAR data to model slope, aspect, and shadowing in the 7 km2 study area to find suitable roof segments for solar panel installation and estimate the solar potential of each segment. This process was supplemented by an analysis of land surface temperature and urban greenness measured through the Normalized Difference Vegetation Index (NDVI) from Landsat 8 Operational Land Imager and Thermal Infrared Sensor (OLI/TIRS) observations. These metrics serve to target areas for cooling initiatives aimed at reducing Satellite Beach’s overall energy consumption. The team found the total rooftop solar potential throughout the city to be 221,919,330KWh per year with an average annual rooftop photovoltaic, or PV, potential of 55,647KWh per building. As such, the average building could generate over five times the annual energy needs for an average household if PV panels were installed on all viable areas of its roof.

Spencer Nelson↗

Installation package - home solar heater

Installation of commerical solar-heating system at two story, three bedroom house in New Hampshire is described in 65 page report. System collectors are integrated part of building replacing conventional roofing or siding. Report also includes general description of system, its operation and guidelines, orientation and references.

Source record↗

MgZnO High‐Voltage Transparent Thin‐Film Transistors Built on Glass

Recently, there has been increasing interest in building‐integrated photovoltaic (BIPV), which enables harvesting solar energy effectively. Large‐area glass components such as windows are widely used in modern constructions. In addition to the PV on opaque components such as walls and roofs, the transparent photovoltaic (TPV) directly built on glass is complementary to fully utilize the PV energy in BIPV. A high‐voltage transparent thin‐film transistor (HVTTFT) built on glass is an ideal option for distributed microinverters for TPV modules. A wide‐bandgap oxide‐based HVTTFT on glass for this purpose is reported. The HVTTFT on glass uses ZnO‐based materials with different functions for two roles: a semiconductor Mg 0.01 Zn 0.99 O (MZO) as TFT channel and Al‐doped ZnO (AZO) as transparent conductive oxide (TCO) electrodes. The centrosymmetric circular structure of the MZO HVTTFT with a high‐k‐stacking gate dielectric enables a blocking voltage as high as ≈1 kV and an on/off ratio of 10 6 . The device exhibits an average optical transmittance of 81% over the visible spectrum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Commercial/industrial photovoltaic module and array requirement study. Low-cost solar array project engineering area

Design requirements for photovoltaic modules and arrays used in commercial and industrial applications were identified. Building codes and referenced standards were reviewed for their applicability to commercial and industrial photovoltaic array installation. Four general installation types were identified - integral (replaces roofing), direct (mounted on top of roofing), stand-off (mounted away from roofing), and rack (for flat or low slope roofs, or ground mounted). Each of the generic mounting types can be used in vertical wall mounting systems. This implies eight mounting types exist in the commercial/industrial sector. Installation costs were developed for these mounting types as a function of panel/module size. Cost drivers were identified. Studies were performed to identify optimum module shapes and sizes and operating voltage cost drivers. The general conclusion is that there are no perceived major obstacles to the use of photovoltaic modules in commercial/industrial arrays.

Source record↗

Integrated residential photovoltaic array development

The design details of an optimized integrated residential photovoltaic module/array are presented. This selected design features a waterproofing and mounting scheme which was devised to simplify the installation procedures by the avoidance of complex gasketed or caulked joints, while still maintaining a high confidence that the watertight integrity of the integral roofing surface will be achieved for the design lifetime of the system. The production and installation costs for the selected module/array design are reported for a range of annual production rates as a function of the cost of solar cells.

Shepard, N. F., Jr.↗

Analysis of Photovoltaic Energy: CRADA Number CRD-21-17862 (Cooperative Research and Development Final Report)

For this project, NREL will work with the Participant to model phase change material performance, model photovoltaic thermodynamics performance, and predict photovoltaic module durability based on environmental conditions to help develop optimized photovoltaic roofing designs. This project will develop thermodynamic models of integrated photovoltaic roofing with phase change materials. These models will be used to optimize the materials and design selections based on reducing photovoltaic operating temperatures while balancing cost effective integration of phase change materials.

14 SOLAR ENERGY↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Potential benefits and optimization of cool-coated office buildings: A case study in Chongqing, China

Increasing envelope facet albedos considerably reduces solar heat gain, thus yielding building cooling energy savings. Few studies have explored the potential benefits of utilizing cool coatings on building envelopes (“cool-coated buildings”) based on life-cycle cost analysis. A holistic approach integrating the field testing, building energy simulation, and a 20-year life-cycle-based optimization was developed to explore cool-coated building performance and the maximum net savings of optimal building envelope retrofit and design. Experimental results showed that applying cool coatings to a west wall of an office building in Chongqing, China reduced its exterior surface temperature by up to 9.3 °C in summer. Additionally, simulation results showed that in Chongqing, making the roof and walls cool could reduce annual HVAC electricity use by up to 11.9% in old buildings (with poorly insulated envelopes) and up to 5.9% in new buildings. Retrofitting old buildings with a cool roof provided the net savings per modified area with present values up to 42.8 CNY/m2; retrofitting a new building with a cool roof or cool walls was not cost-effective. Optimizing both envelope insulation and envelope albedo can achieve 5.6 times the net savings of optimizing the insulation only, and 1.6 times that of optimizing albedo only.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Addressing the split incentive challenge for rooftop solar PV and battery energy storage in multifamily rental buildings (CRADA 638 Final Report)

This project advances the understanding of how roof solar PV systems and battery energy storage systems (BESS) can be effectively deployed in multifamily residential buildings, a sector that has historically faced barriers due to misaligned incentives between landlords and tenants. By leveraging high-resolution building stock data and simulation tools, the research demonstrates how energy consumption patterns vary across building types, climates, and occupant characteristics, and how these variations influence the optimal sizing and operation of distributed energy resources. A key contribution is the development of a publicly accessible, web-based tool named RESIDE (Residential Energy Systems & Infrastructure Data Evaluation) that allows users to explore building energy use and evaluate solar and battery configurations without requiring specialized expertise. This significantly lowers the barrier to entry for stakeholders such as property owners, utilities, and policymakers. From a technical perspective, the project shows that integrating rooftop solar PV with battery energy storage can substantially reduce electricity costs and peak demand through strategies such as energy arbitrage and peak shaving. The modeling framework incorporates real-world constraints, including time-of-use electricity pricing and battery degradation, providing realistic and actionable insights. Economically, the results indicate that properly sized systems can deliver meaningful cost savings, improving the feasibility of energy investments in multifamily housing. More broadly, the project benefits the public by supporting the transition to affordable and reliable energy, particularly in rental multifamily housing where adoption has traditionally lagged.

14 SOLAR ENERGY↗

An agent-based approach to study the diffusion rate and the effect of policies on joint placement of photovoltaic panels and green roof under climate change uncertainty

As two of the highest trending green technologies, photovoltaic panels and green roofs are proven to be effective practices for energy generation and energy saving. The achievable impact from the widespread installation of such technologies is, however, not clearly established. This is mainly because the degree of this impact highly depends on the inherently uncertain environmental and climate factors, as well as the unknown adoption rates of these technologies, which in turn depend on different characteristics of decision makers and interactions among them. To that end, this study aims to investigate the diffusion rate of these green technologies under uncertainties caused by climate change, characteristics of adopters, and their interactions. An integrated framework is developed to capture the interplay between financial and attitudinal aspects, as well as the uncertainties due to both the stochastic nature of system parameters and the interactions among agents involving human beings. Specifically, this framework consists of a integer programming model to optimize the green roof and/or photovoltaic panel installation settings for a given building under climate change uncertainty, and an agent-based model to factor in the role of human behavior and interactions. A case study for the city of Knoxville, TN, is presented to evaluate the effects of different policies on the diffusion rate of the green technologies of interest. The results show that the affordability of green technologies and public awareness are the key drivers of the adoption of these technologies, which highlight the important role of the decision makers in impacting the diffusion rate.

14 SOLAR ENERGY↗