Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rossi-α”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Rossi-α Measurements on a System Consisting of Weapons Grade Plutonium Moderated by Polyethylene

A critical experiment was performed on the Planet assembly to provide nuclear data in a thermal neutron spectrum, in particular to provide experimental data to help validate thermal scattering laws for polyethylene. The fuel consisted of layers of weapons grade plutonium plates that were moderated and reflected by various thicknesses of high density polyethylene. Rossi-α measurements were performed on a slightly modified configuration from the configuration used for the critical measurements. The Rossi-α measurement techniques are discussed and results are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rossi-α measurements on a system consisting of weapons grade plutonium moderated by polyethylene

A critical experiment was performed on the Planet critical assembly to provide nuclear data in a thermal neutron spectrum, in particular to provide experimental data to help validate thermal scattering laws for polyethylene. The fuel consisted of layers of weapons grade plutonium plates that were moderated and reflected by various thicknesses of high density polyethylene. Rossi-α measurements were performed on a slightly modified configuration from the configuration used for the critical measurements. The Rossi-α measurement techniques are discussed and results are presented. The neutron spectrum appears to be extremely thermal when compared to other thermal systems and the configuration will be able to validate thermal scattering law.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Rossi-α Measurements on a System Consisting of Weapons Grade Plutonium Moderated by Polyethylene [Poster]

A series of experiments nicknamed "TEX," standing for Thermal-Epithermal eXperiments, were performed at the National Criticality Experiments Research Center (NCERC) on the Planet critical assembly. The TEX experiment campaigns are a collaboration between Los Alamos National Laboratory (LANL) and Lawrence Livermore National Laboratory (LLNL) and funded by the Nuclear Criticality Safety Program (NCSP). The TEX experiment consists of several campaigns; this work specifically discusses measurements made on one series of TEX experiments designed to examine the thermal scattering law (TSL) for polyethylene. This series consisted of two different critical configurations which contain plutonium fuel. The plutonium plates are 2 in. by 3 in. by 0.125 in. Zero Power Physics Reactor (ZPPR) plates and are placed in a tray in an array of 6 plates by 4 plates wide creating a 12 in. by 12 in. square. These trays of plutonium are interleaved between polyethylene plates. These measurements differ from previous TEX experiments in that they examine a more thermal neutron spectrum than previously examined by interleaving much thicker interstitial moderating plates than the previous measurements. The two configurations differ in the thickness of polyethylene between the fissile material. While the experiment was designed to examine the TSL, this work only examines the results of Rossi-α measurements on the two different configurations. For both configurations, Rossi-α measurements were performed to experimentally validate the neutron spectrum.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data from Rossi-α and Pulsed Neutron Prompt Neutron Time Decay Measurements at the Oak Ridge Critical Experiments Facility

This report briefly describes the prompt neutron decay measurements by the Rossi-α and pulsed neutron methods performed at the Oak Ridge Critical Experiments Facility. It briefly describes the measurement equipment, the type of data, and how to access the actual data from the Laboratory Records Department at Oak Ridge National Laboratory and the International Nuclear Criticality Safety Benchmark Evaluation Program at Idaho National Laboratory. Most of the data was acquired between 1960 and 1975 with weapons-grade enriched uranium metal assemblies. It also includes measurement of these types performed at Los Alamos National Laboratory by Oak Ridge National Laboratory with the JEZEBEL and FLATTOP criticality assemblies and other plutonium metal parts. The purpose of this report is to support future mining of the data for publication of additional information that can be used to verify calculational methods and nuclear cross sections. Present calculational methods can be used to directly calculate the measured data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Using Prompt Neutron Decay Constant Measurements to Obtain Additional Kinetics Information

Prompt neutron decay constant measurements are typically used to infer the prompt neutron lifetime in a chain-reacting system, but these measurements include much more information about the kinetics of the system. This work focuses specifically on the Rossi-α method of measuring the prompt neutron decay constant. The Rossi-α system of equations consists of five unknown parameters. With five unknowns and three equations, the system of equations solved by the Rossi-α measurement is under-determined. It has been postulated that a well posed problem can be formulated using independent measurement configurations on a single system. The external source strength, the effective delayed neutron fractions, and Diven’s parameter do not typically change for different configurations of a single experiment. If good detector geometry is chosen, the detector efficiency does not change for multiple measurements of a single experiment using Rossi-α measurements. By making these assumptions, there are only two unique variables. This knowledge can be used to solve for most of the unique parameters using two independent, unique Rossi-α measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Future of the MUSiC Experiment Data

The Measurements of Uranium Subcritical and Critical (MUSiC) experiment was a highly enriched uranium (HEU) experiment performed at the National Criticality Experiments Research Center (NCERC) executed between December 2020 and April 2021. The experiment intended to measure criticality and reactor kinetics parameters in a bare HEU system. The experiment concurrently measured radiation signatures from the system while utilizing different neutron source types. This was an attempt to benchmark both detectors and analysis techniques against one another for identical measurements. The experiment consisted of the Rocky Flats HEU hemi-shells constructed into ten configurations spanning between deeply subcritical (about 14 kgs) to supercritical (about 60 kgs). Two of the ten configurations were supercritical and the other eight were subcritical. The two supercritical configurations, often referred to as the critical configurations, were documented into an International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmark evaluation and submitted to the technical review group (TRG). The subcritical configurations of the MUSiC experiment were examined using three different detection systems. The systems include: the NoMAD He-3 neutron detector which consists of 15 He-3 tubes surrounded by a polyethylene matrix, a liquid scintillator system called the Rossi-α Measurement Rapid Organic Discriminating Detector (RAM-RODD), and a trans-stilbene organic scintillator array (OSCAR) provided by the University of Michigan. The NoMAD and RAM-RODD data are planned to be evaluated in two separate ICSBEP evaluations utilizing neutron noise methods such as Feynman Variance-to-Mean, Rossi-α and the pulsed neutron source method. Each of the subcritical configurations were examined using three different source types including: a Cf-252 source in the center, with only the intrinsic neutron source in the HEU, and with an external D-T neutron generator.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Examination of Digital-Delay Rossi-$\alpha$ for 252 Cf-Driven Highly Enriched Uranium Using Organic Scintillators

Neutron noise techniques constitute several analysis methods applicable to non-destructive assay. One technique is the Rossi-α method to calculate the prompt neutron decay constant (α) or its inverse, the prompt neutron period (1/α), for assemblies of fissionable material. This work evaluates a high-data-throughput measurement at the National Criticality Experiments Research Center (NCERC) with organic scintillators measuring a subcritical assembly of highly enriched uranium (HEU) metal (93% 235 U). The assembly comprises hemi shells stacked together to form fully closed shells and is driven by a Cf source at the center. The assembly is a total of 59.85 kg HEU and a k eff of 0.99, according to MCNP6.2 KCODE simulations. Measurements were acquired with a three-by-four array of 5.08-cm-diameter by 5.08-cm-length trans-stilbene crystals 166 cm from the assembly center. Two types of coincident binning methods are used to build the Rossi-α distribution of coincident neutron detections: A) type 1 binning, also known as any-and-all forward time differences, and B) type 1 binning with a digital-delay technique that is analogous to Orndoff’s use of delay cabling in early Rossi-alpha measurements. Method B) disregards same-detector coincidences and once all nearest time coincidences are collected between all detectors after a trigger, a time delay of 0.75 µs is implemented. The measured prompt neutron decay constants for both techniques are calculated from single exponential fits and the two methods are compared. Method A) shows an apparent timing discontinuity near 500 ns time differences. This timing discontinuity interferes with the fitting method used to calculate the prompt neutron decay constant. Method B) mitigates the artificial timing discontinuity and removes the disagreement of the fit. Future work will model the time-dependent detector response to discern why this timing discontinuity occurs, discern how Method B) reduces the amplitude of this timing discontinuity, and apply this method to critical assembly measurements to ultimately confirm the recommendation to use Method B) for high-data-throughput measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of the MUSIC 3 He Multiplicity Data

A measurement campaign called the Measurement of Uranium Subcritical and Critical (MUSiC) was performed on a range of configurations of highly-enriched uranium (HEU) from December 2020 through April of 2021. While part of the focus was to measure reactor kinetics parameters on delayed supercritical systems, an additional focus was performing neutron noise measurements on subcritical configurations from deeply subcritical to nearly delayed critical. Multiple detector systems were used to perform these measurements, such as a 3 He multiplicity detector called the Neutron Multiplicity Array Detector (NoMAD) and a liquid scintillator system called the Rossi-α Measurement Rapid Organic Discriminating Detector (RAM-RODD). Also included were a scintillator system from the University of Michigan and a set of small 3He tubes that have previously been used to measure Rossi-α values on near-critical systems. The focus of this paper will be a comparison of prospective analysis methods for the NoMAD measurements. Previous subcritical measurements at the National Criticality Experiments Research Center (NCERC) submitted to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) used the Hage-Cifarelli formalism of the Feynman Variance-to-Mean method. This relies on the time correlations of neutron detections to infer the spontaneous fission rate and neutron multiplication of a system through binning the time tagged detections and analyzing resulting histograms of the numbers of counts. However, there are other neutron noise methods that rely on similar processes, such as the Hansen-Dowdy formalism which uses a slightly different methodology to extract multiplication from the neutron multiplicity counting moments. Comparisons can be made between these experimental results and those obtained through simulations to validate or identify deficiencies in analysis, detection methods, or the underlying nuclear data. Different time gating strategies and their effects on count rate uncertainties are also investigated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Multiplication Neutron Noise Measurements Using the 7uPCX Assembly

The Seven Percent Critical Experiment, or 7uPCX, is a system that mimics the physics of light water nuclear reactor systems by using uranium dioxide fuel pins at an enrichment of approximately 7%. 7uPCX is often used for benchmarking and nuclear data purposes. As part of a collaboration between Lawrence Livermore National Laboratory, Los Alamos National Laboratory, Sandia National Laboratories, and the Institut de Radioprotection et de Sûreté Nucléaire, measurements were performed in support of a high-multiplication, subcritical benchmark candidate for a thermal system. The measurements were completed by making subcritical configurations using the fuel loading pattern of a well-documented configuration of the Seven Percent Critical Experiment at Sandia National Laboratories, which exists as a benchmark in the International Criticality Safety Benchmark Evaluation Project handbook. These measurements, which aimed to capture multiplications ranging from approximately 10 to 1,000, also serve as an intercomparison between both the fielded detector systems and analysis methodologies with the goal of better characterizing the detectors and their ability to capture the state of the criticality these types of systems. Los Alamos National Laboratory’s measurements for this collaboration were made with five linked helium-3 based neutron multiplicity detectors placed on the periphery of the reactor tank beyond the infinite reflector thickness of water, and four organic scintillators placed in dry-wells in-reactor near the edge of the upper fuel grid plate. This work captures the Los Alamos National Laboratory measurements, the Rossi-α and Feynman-Y results, provides an intercomparison between the results of the 3 He neutron detectors and the organic scintillators, compares to simulation where possible, and expands on future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of the Rossi-alpha method to simulations of HEU and organic scintillators

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook contains thousands of high-quality benchmark measurements that include detailed descriptions of experiment designs and exhaustive accounting of uncertainties. These benchmarks are used extensively by the criticality safety and nuclear data communities. A subcritical benchmark involving bare, highly enriched uranium (HEU) has yet to be accepted to the handbook. The Measurement of Uranium Subcritical and Critical (MUSiC) was proposed to address this gap. MUSiC will be performed at the National Criticality Experiments Research Center (NCERC) and will leverage bare HEU hemisphere shells that can be assembled in a variety of configurations. The measurement has the following key benefits: it will be the first set of fast, subcritical measurements of HEU to be submitted to ICSBEP; ten configurations will be measured spanning from nearly no multiplication to critical (e.g., it is a measurement of similar systems with different re activities); measurements of an all-HEU system will be of value for nuclear data validation, providing results that assist in determining biases in both measurements and simulations. A variety of detector systems will be used including a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (#8960;) × 7.59 cm 3He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), and an array of eight 5.08 cm (#8960;) × 5.08 cm EJ-309 organic scintillator detectors. The focus of this work is the simulation of the subcritical MUSiC configurations including the EJ-309 detectors and the application of the Rossi-α method. The EJ-309 organic scintillator detector array is a new detection system that will be deployed at NCERC. Organic scintillators are ideal for measurements of fast, subcritical systems due to their short time response on the order of nanoseconds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delayed Critical Enriched Uranium Metal, 7-in.-diam. Cylinder with Thin Stainless Steel Top and Bottom Reflectors

Three 7 in. diameter highly enriched uranium (HEU; 93.17 wt % 235 U) metal cylinders were assembled on the vertical assembly machine of the Oak Ridge Critical Experiments Facility (ORCEF) with thin stainless steel reflectors (0.5, 1, and 2 in. thick) on the top and bottom. These experiments were performed during January 13–25, 1965, and used seven operational days at ORCEF. Before these experiments, unreflected and unmoderated 7 in. diameter HEU metal cylinders had been assembled to delayed criticality at ORCEF, and the results were benchmarked in HEU-MET-FAST-051. In addition to the critical experiments, the prompt neutron decay constant was measured via the Rossi-α technique, and those results are also presented in this report. To achieve near-delayed-critical systems, 5 × 5 × 0.03125 in. rectangular uranium metal parts were used on top of 7 in. diameter cylinders inside the top reflector. The delayed critical configuration from the three experiments described herein are acceptable for use as criticality safety benchmark experiments for the International Criticality Safety Benchmark Evaluation Program (ICSBEP), coordinated by the Nuclear Energy Agency, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainty in $k_{eff}$ is expected to be as low as ±0.0002. The prompt neutron time decay data could be the basis of an International Reactor Physics Evaluation Program benchmark.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification and Validation of the New MCNP6.3 Criticality Features [Slides]

This presentation touches on a separate MCNP6.3 V&V document reports on all the default calculations for all test suites. Here, we look at new optional features of the MCNP6.3 code with Fission-matrix-based options, Convergence and population testing, and Automated acceleration of the fission source additionally Doppler Broadening Resonance Correction. Also touched on are validation benchmarks: criticality, crit_expanded, and Rossi-α. All the new MCNP6.3 options give statistically equivalent results and either provide a reduction or no change in computational cost. We consider giving these new features a try and using them for all criticality calculations.

97 MATHEMATICS AND COMPUTING↗

Validation of New MCNP6.3 Features for Critical and Subcritical Benchmark Simulations [Slides]

A separate MCNP6.3 V&V document reports on all the default calculations for all test suites was introduced. Here, we look at new optional features of the MCNP6.3 code. Then, Fission-matrix-based options with Convergence and population testing and Automated acceleration of the fission source and Doppler Broadening Resonance Correction and HDF5 Particle Track Output (PTRAC) and Validation benchmarks: criticality, Rossi-α, and subcritical multiplication. All the new MCNP6.3 options give statistically equivalent results and should be considered for default usage in criticality and subcritical multiplication calculation work. Discussed are two separate papers at the upcoming 2023 International Conference on Nuclear Criticality Safety (ICNC 2023) that give more details on the results presented here.

97 MATHEMATICS AND COMPUTING↗

Verification and Validation of the New MCNP6.3 Criticality Features

The MCNP6® code, version 6.3, has been extensively verified and validated for many applications. The use of the same default capabilities existing in the MCNP6.2 code are also used in the verification and validation (V&V) of the MCNP6.3 code. In this paper, selected new features, code enhancements, and bug fixes in the MCNP6.3 code that impact criticality safety applications are described and investigated. More specifically, the changes within the MCNP6.3 code that are studied in this work include both the new fission matrix and the Doppler broadening resonance correction (DBRC) features. For nuclear criticality safety applications, the V&V benchmark problems within the criticality, extended criticality, and Rossi-α suites are used to study the upgrades within the MCNP6.3 code. Some additional investigations into benchmarks at elevated temperatures are used to showcase the impacts of the temperature-specific capabilities.

97 MATHEMATICS AND COMPUTING↗

The Jupiter High-240 Experiment

The Jupiter High-240 experiment was performed in May of 2019 by researchers from Los Alamos National Laboratory (LANL) at the National Criticality Experiments Research Center (NCERC) in the Device Assembly Facility (DAF) located at the Nevada National Security Site (NNSS). This experiment has previously been mentioned briefly in prior publication related to a collaborative effort with the Japan Atomic Energy Agency (JAEA) to assess lead void coefficients of reactivity in uranium- and plutonium-fueled systems with lead. This series of experiments supports JAEA’s research into the development of an accelerator driven transmutation system for spent nuclear fuel. The Jupiter High-240 experiment built upon the previous Jupiter experiment by incorporating plutonium fuel plates with higher 240 Pu content. Efforts to formally benchmark the original Jupiter experiment have continued for inclusion in the benchmark handbook of the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Whereas there is much similarity between the two Jupiter experiments, there is a desire to also evaluate and benchmark this second experiment to further contribute towards the availability of lead-sensitive benchmarks. The components utilized in these two experiments have also been used to perform other subcritical and Rossi-α measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Why the US Needs an Enduring Plutonium Critical Assembly

Jezebel (operated from 1954-1977) has been the primary experiment for fast 239 Pu nuclear data validation for the last 70 years. Validation has included not only k eff , but also spectral indicies, Rossi-α, reactivity coefficients, and neutron leakage spectra. While this has been incredibly valuable to the community, there are three major issues. The first issue is that documentation on many of these experiments were lacking, leading to large uncertainties or (even worse) incorrect assumptions. The second issue is that while there have been many advances in research, there is no way to test those new advances today. The last issue is that since the assembly only operated for 23 years (and at time when 30 other critical assemblies were operating at the same facility and nuclear weapons testing was occurring), there were limited opportunities to observe how any system parameters changed as a function of time. Note that this work is not suggesting that a "Jezebel re placement" used for a limited experiment campaign would have great value. A new enduring (100 year target) plutonium (Pu) assembly with simple geometry and low uncertainties, however, would be extremely valuable. Such a capability would have a transformative impact on many research areas including nuclear data validation, analytical methods validation, dosimetry, reactor kinetics, and materials. The need for a new plutonium assembly is not new: it has been in the DOE Nuclear Criticality Safety Program (NCSP) Mission and Vision for over 10 years and was also the top priority established at the 2022 National Criticality Experiments Research Center (NCERC) Futures meeting. This work will discuss how such a new capability would help ensure that the US retains international leadership in plutonium research. Last, a brief overview of Lilith, a project aimed to design a new enduring plutonium assembly for operation at the NCERC will be given.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of Measured and Simulated Neutron Counting with 3He Detectors and the Subcritical Water-Moderated UO2 7uPCX Assembly

An experiment designed to compare neutron noise analysis techniques on subcritical assemblies using differing neutron detector designs was developed as a collaborative effort between the Institut de radioprotection et de surete nucleaire (IRSN), Los Alamos (LANL), Lawrence Livermore (LLNL), and Sandia National Laboratories. This experiment has the final goal of characterizing neutron noise analysis accuracy in determining multiplication in light water systems for various neutron detection systems. This experiment utilized the Seven Percent Critical Experiment (7uPCX) facility at Sandia National Laboratories. The 7uPCX is an assembly designed to investigate light water systems with fuel enrichment above 5% and is able to use square or hex grid plates with varying pitches.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗