Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAFIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Quantum noise properties of CT images with anatomical textured backgrounds across reconstruction algorithms: FBP and SAFIRE

Purpose: Quantum noise properties of CT images are generally assessed using simple geometric phantoms with uniform backgrounds. Such phantoms may be inadequate when assessing nonlinear reconstruction or postprocessing algorithms. The purpose of this study was to design anatomically informed textured phantoms and use the phantoms to assess quantum noise properties across two clinically available reconstruction algorithms, filtered back projection (FBP) and sinogram affirmed iterative reconstruction (SAFIRE). Methods: Two phantoms were designed to represent lung and soft-tissue textures. The lung phantom included intricate vessel-like structures along with embedded nodules (spherical, lobulated, and spiculated). The soft tissue phantom was designed based on a three-dimensional clustered lumpy background with included low-contrast lesions (spherical and anthropomorphic). The phantoms were built using rapid prototyping (3D printing) technology and, along with a uniform phantom of similar size, were imaged on a Siemens SOMATOM Definition Flash CT scanner and reconstructed with FBP and SAFIRE. Fifty repeated acquisitions were acquired for each background type and noise was assessed by estimating pixel-value statistics, such as standard deviation (i.e., noise magnitude), autocorrelation, and noise power spectrum. Noise stationarity was also assessed by examining the spatial distribution of noise magnitude. The noise properties were compared across background types and between the two reconstruction algorithms. Results: In FBP and SAFIRE images, noise was globally nonstationary for all phantoms. In FBP images of all phantoms, and in SAFIRE images of the uniform phantom, noise appeared to be locally stationary (within a reasonably small region of interest). Noise was locally nonstationary in SAFIRE images of the textured phantoms with edge pixels showing higher noise magnitude compared to pixels in more homogenous regions. For pixels in uniform regions, noise magnitude was reduced by an average of 60% in SAFIRE images compared to FBP. However, for edge pixels, noise magnitude ranged from 20% higher to 40% lower in SAFIRE images compared to FBP. SAFIRE images of the lung phantom exhibited distinct regions with varying noise texture (i.e., noise autocorrelation/power spectra). Conclusions: Quantum noise properties observed in uniform phantoms may not be representative of those in actual patients for nonlinear reconstruction algorithms. Anatomical texture should be considered when evaluating the performance of CT systems that use such nonlinear algorithms.

60 APPLIED LIFE SCIENCES↗

Comparison of image noise and image quality between full-dose abdominal computed tomography scans reconstructed with weighted filtered back projection and half-dose scans reconstructed with improved sinogram-affirmed iterative reconstruction (SAFIRE*)

Purpose: To retrospectively compare the image noise, signal-to-noise ratio (SNR), and subjective image quality between CT images acquired with a dual-source, split-dose imaging protocol reconstructed at full and half doses with weighted filtered back projection (wFBP) and an improved sinogram-affirmed iterative reconstruction algorithm (SAFIRE*). Methods: Fifty-three consecutive patients underwent contrast-enhanced CT of the abdomen using a standardized dual-source, single energy CT protocol. Half-dose images were retrospectively generated using data from one detector only. Full-dose datasets were reconstructed with wFBP, while half-dose datasets were reconstructed with wFBP and SAFIRE* strengths 1–5. Region of interest analysis was performed to assess SNR and noise. Diagnostic acceptability, subjective noise, and spatial resolution were graded on a 10-point scale by two readers. Statistical analysis was carried out with repeated measures analysis of variance, Wilcoxon signed rank test, and Cohen’s κ test. Results: With the increasing strengths of SAFIRE*, a progressive reduction in noise and increase in SNR (p < 0.01) was observed. There was a statistically significant decrease in objective noise and increase in SNR in half-dose SAFIRE* strength 4 and 5 reconstructions compared to full-dose reconstructions using wFBP (p < 0.01). Qualitative analysis revealed a progressive increase in diagnostic acceptability, decrease in subjective noise and increase in spatial resolution for half-dose images reconstructed with the increasing strengths of SAFIRE* (p < 0.01). Conclusions: Half-dose CT images reconstructed with SAFIRE* at strength 4 and 5 have superior image quality compared to full-dose images reconstructed with wFBP. SAFIRE* potentially allows dose reductions in the order of 50% over wFBP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Description of SAFIRE for ISES

The SAFIRE (Spectroscopy of the Atmosphere using Far Infrared Emission) is a limb emission experiment using a far-IR Fourier transform spectrometer (FTS) and a mid-IR broadband multispectral radiometer covering the range 80 to 1600/cm. The purpose of this experiment is to obtain vertical distributions of temperature and key constituents of O(y), HO(y), NO(y), ClO(y), and BrO(y) families in the stratosphere, mesosphere, and thermosphere. The spectral channels and gases within each channel are summarized. The instrument includes a 48 element (6 x 8) Ge:GA detector array operating at 4 K in the far-IR and a 105 element (7 x 15) HgCdTe array operating at 80 K in the mid-IR. The SAFIRE uses four different scan modes for vertical coverage and resolution to address various scientific requirements. The SAFIRE data reduction will start with the retrieval of temperature profile as a function of pressure using two CO2 channel data. Constituent distributions then are obtained from other channel data using the retrieved temperature profile. The SAFIRE measurements are limited to the region above the tropopause because of radiance saturation by H2O and clouds. The computational capability necessary to process at the instrument data rate is estimated to be 19 MFLOPS for FTS data and 0.02 MFLOPS for radiometer data. It seems, therefore, that the real-time applications of SAFIRE data using an onboard processing device is not feasible. Although a temperature anomaly may be detected from the two CO2 radiometer channels using an onboard processor for the stratosphere, it is not possible to distinguish between CO2 outflux and temperature anomaly. Temperature anomaly does not, therefore, offer tropospheric information useful for real-time application.

Park, Jae H.↗

SAFIRE: A Far-Infrared Imaging Spectrometer for SOFIA

The SOFIA airborne observatory will provide a high spatial resolution, low background telescope for far-infrared astrophysical investigations. Selected as a PI instrument for SOFIA, SAFIRE is an imaging Fabry-Perot spectrograph covering 145 micrometers-655 micrometers with spectral resolving power of approx. 1500 (200km/s). This resolution is well matched to extragalactic emission lines and yields the greatest sensitivity for line detection. SAFIRE will make important scientific contributions to the study of the powering of ULIRGs and AGN, the role of CII cooling in extragalactic star formation, the evolution of matter in the early Universe, and the energetics of the Galactic center. SAFIRE will employ a two-dimensional pop-up bolometer array to provide background-limited imaging spectrometry. Superconducting transition edge bolometers and SQUID amplifiers have been developed for these detectors. An engineering prototype of SAFIRE with a small but cutting edge detector array will be available for use during the initial SOFIA operations; further expansion to larger format arrays will be incorporated during SAFIRE's lifetime.

Shafer, Richard A.↗

Thermal design trades for SAFIR architecture concepts

SAFIR is a IO-meter, 4 K space telescope optimized for wavelengths between 20 microns and 1 mm. The combination of aperture diameter and telescope temperature will provide a raw sensitivity improvement of more than a factor of 1000 over presently-planned missions. The sensitivity will be comparable to that of the JWST and ALMA, but at the critical far-IR wavelengths where much of the universe's radiative energy has emerged since the origin of stars and galaxies. We examine several of the critical technologies for SAFIR which enable the large cold aperture, and present results of studies examining the telescope optics and the spacecraft thermal architecture. Both the method by which the aperture is filled, and the overall optical design for the telescope can impact the potential scientific return of SAFIR. Thermal architecture that goes far beyond the sunshades developed for the James Webb Space Telescope will be necessary to achieve the desired sensitivity of SAFIR. By combining active and passive cooling at critical points within the observatory, a significant reduction of the required level of active cooling can be obtained.

infrared telescopes↗

Heterodyne Receiver Requirements for the Single Aperture Far-Infrared (SAFIR) Observatory

In the next few years, work will commence in earnest on the development of technology for the next generation large cryogenic far-infrared telescope: the Single Aperture Far- Infrared (SAFIR) Observatory. SAFIR's science goals are driven by the fact that youngest stages of almost all phenomena in the universe are shrouded in absorption by cool dust, resulting in the energy being emitted primarily in the far-infrared. The earliest stages of star formation, when gas and dust clouds are collapsing and planets forming, can only be observed in the far-infrared. Spectral diagnostics in the far-infrared are typically quite narrow (approx. 1 km/s) and require high sensitivity to detect them. SAFIR is a 10 m-class telescope designed for cryogenic operation at L2, removing all sources of thermal emission from the telescope and atmosphere. Despite its limited collecting area and angular resolution as compared to the ALMA interferometer, its potential for covering the entire far-infrared band cannot be matched by any ground-based or airborne observatory. This places a new challenge on heterodyne receivers: broad frequency coverage. The ideal mixer would be able to detect frequencies over several octaves (e.g., 0.6 THz - 12 THz) with near quantum-limited performance at all frequencies. In contrast to ground-based observatories, it may not be necessary to strive for high instantaneous bandwidth, as direct detection spectroscopy is preferable for bandwidths of Delta v/ v greater than or equal to 10(exp -4) (e.g., 1 GHz at 10 THz). We consider likely directions for technology development for heterodyne receivers for SAFIR.

Benford, Dominic J.↗

SAFIRE : Scalable and Accurate Fault Injection for Parallel Multi-threaded Applications

The software SAFIRE implements a fault injection tool to evaluate the impact of soft errors on parallel, multi-threaded applications. It implements instruction-level fault models that emulate soft errors by flipping bits in the register operands of executed machine instructions. SAFIRE is based on the LLVM compiler and utilizes novel techniques to optimize instruction instrumentation and fault injection. By detailed measurements, SAFIRE is multiple times faster than other state-of-the-art fault injection techniques, while having the same accuracy.

Georgakoudis, Giorgis↗

The spectroscopy of the atmosphere using far-infrared emission experiment (SAFIRE)

The goal of the SAFIRE experiment is to improve understanding of the middle-atmospher ozone distribution by conducting and analyzing global-scale measurements of important chemical, radiative and dynamical processes, including coupling among these processes and atmospheric regions. This will be accomplished by observing vertical profiles of temperature and key gases in the main chemical families. A detailed listing of SAFIRE measurements, including sepctral ranges, altitude ranges, IFOV, spatial and temporal resolution, latitude coverage and estimated precision is provided. The temperature, O3, CH4, and H2O observations will be useful for deriving and studying dynamical quantities such as geopotential height, potential vorticity, balanced winds and Eliassen-Palm fluxes. The SAFIRE observations will provide important data for study of chemistry, dynamics and transport processes. This experiment was conceived in response to a need for simultaneous measurements of odd hydrogen gases. These include gases such as OH, HO2, and atomic oxygen, which have not been observed by past satellite experiments and which will not be measured by any of teh Upper Atmosophere Reserach Satellite (UARS) experiments to be launched in 1991.

Russell, J. M., III↗

The HAWC and SAFIRE Adiabatic Demagnetization Refrigerators

The High-Resolution Airborne Wide-band Camera (HAWC) and Submillimeter and Far Infrared Experiment (SAFIRE) are far-infrared experiments which will fly on the Stratospheric Observatory for Infrared Astronomy (SOFIA) aircraft. HAWC's detectors will operate at 0.2 Kelvin, while those of SAFIRE will be at 0.1 Kelvin. Each instrument will include an adiabatic demagnetization refrigerator (ADR) to cool its detector stage from the liquid helium bath temperature (HAWC's at 4.2 Kelvin and SAFIRE's pumped to about 1.3 Kelvin) to its operating temperature. Except for the magnets used to achieve the cooling and a slight difference in the heat switch design, the two ADRs are nearly identical. We describe the ADR design and present the results of performance testing.

Tuttle, Jim↗

Far-Infrared Imaging Spectroscopy with SAFIRE on SOFIA

The SOFIA airborne observatory will provide a high spatial resolution, low background telescope for far-infrared astrophysical investigations. Selected as a PI instrument for SOFIA, SAFIRE is an imaging Fabry-Perot spectrograph covering 100 micrometers - 655 micrometers, with spectral resolving power of approx. 1500 (200 kilometers per second). This resolution is well matched to extragalactic emission lines and yields the greatest sensitivity for line detection. SAFIRE will make important scientific contributions to the study of the powering of ULIRGs and AGN, the role of CII cooling in extragalactic star formation, the evolution of matter in the early Universe, and the energetics of the Galactic center. SAFIRE will employ a two-dimensional pop-up barometer array in a 16 x 32 format to provide background-limited imaging spectrometry. Superconducting transition edge barometers and SQUID amplifiers have been developed for these detectors.

Shafer, Richard A.↗

SAFIRE: Far-Infrared Imaging Spectroscopy with SOFIA

The SOFIA airborne observatory will provide a high spatial resolution, low background telescope for far-infrared astrophysical investigations. Selected as a PI instrument for SOFIA, SAFIRE is an imaging Fabry-Perot spectrograph covering 145 microns-655microns, with spectral resolving power of approx. 1500 (200 kilometers per second). This resolution is well matched to extragalactic emission lines and yields the greatest sensitivity for line detection. SAFIRE will make important scientific contributions to the study of the powering of ULIRGs and AGN, the role of CII cooling in extragalactic star formation, the evolution of matter in the early Universe, and the energetics of the Galactic center. SAFIRE will employ a two-dimensional pop-up bolometer array to provide background limited imaging spectrometry. Superconducting transition edge bolometers and SQUID amplifiers have been developed for these detectors.

Benford, Dominic↗

Charting the Winds that Change the Universe, II The Single Aperture Far Infrared Observatory (SAFIR)

The Single Aperture Far Infrared Observatory (SAFIR) will study the birth and evolution of stars and planetary systems so young that they are invisible to optical and near-infrared telescopes such as NGST. Not only does the far-infrared radiation penetrate the obscuring dust clouds that surround these systems, but the protoplanetary disks also emit much of their radiation in the far infrared. Furthermore, the dust reprocesses much of the optical emission from the newly forming stars into this wavelength band. Similarly, the obscured central regions of galaxies, which harbor massive black holes and huge bursts of star formation, can be seen and analyzed in the far infrared. SAFIR will have the sensitivity to see the first dusty galaxies in the universe. For studies of both star-forming regions in our galaxy and dusty galaxies at high redshifts, SAFIR will be essential in tying together information that NGST will obtain on these systems at shorter wavelengths and that ALMA will obtain at longer wavelengths.

Leisawitz, David↗

The Single Aperture Far-Infrared (SAFIR) Observatory and its Cryogenic Detector Needs

The development of a large, far-infrared telescope in space has taken on a new urgency with breakthroughs in detector technology and recognition of the fundamental importance of the far-infrared spectral region to questions ranging from cosmology to our own Solar System. The Single Aperture Far-InfraRed (SAFIR) Observatory is l0m-class far-infrared observatory that would begin development later in this decade to meet these needs. SAFIR's science goals are driven by the fact that youngest stages of almost all phenomena in the universe are shrouded in absorption by and emission from cool dust that emits strongly in the far-infrared, 20 microns - 1mm. Its operating temperature (4 K) and instrument complement would be optimized to reach the natural sky confusion limit in the far-infrared with diffraction-limited performance down to at least the atmospheric cutoff at 40 microns. This would provide a point source sensitivity improvement of several orders of magnitude over that of SIRTF. In order to achieve this, large arrays of detectors with NEPs ranging from a few to a hundred zeptowatts/sqrt(Hz) are needed. Very low temperature superconducting transition edge sensors and far-infrared "photon counting" detectors are critical technologies requiring development for the SAFIR mission.

Benford, Dominic J.↗

Charting the Winds that Change the Universe, II: The Single Aperture Far Infrared Observatory (SAFIR)

SAFIR will study the birth and evolution of stars and planetary systems so young that they are invisible to optical and near-infrared telescopes such as NGST. Not only does the far-infrared radiation penetrate the obscuring dust clouds that surround these systems, but the protoplanetary disks also emit much of their radiation in the far infrared. Furthermore, the dust reprocesses much of the optical emission from the newly forming stars into this wavelength band. Similarly, the obscured central regions of galaxies, which harbor massive black holes and huge bursts of star formation, can be seen and analyzed in the far infrared. SAFIR will have the sensitivity to see the first dusty galaxies in the universe. For studies of both star-forming regions in our galaxy and dusty galaxies at high redshifts, SAFIR will be essential in tying together information that NGST will obtain on these systems at shorter wavelengths and that ALMA will obtain at longer wavelengths.

Rieke, G. H.↗

Mission Concept for the Single Aperture Far-Infrared (SAFIR) Observatory

We have developed a preliminary but comprehensive mission concept for SAFIR, as a 10 m-class far-infrared and submillimeter observatory that would begin development later in this decade to meet the needs outlined above. Its operating temperature (< or = 4K) and instrument complement would be optimized to reach the natural sky confusion limit in the far-infrared with diffraction-limited performance down to at least the atmospheric cutoff, lambda > or approx. 40 microns. This would provide a point source sensitivity improvement of several orders of magnitude over that of the Spitzer Space Telescope (previously SIRTF) or the Herschel Space Observatory. Additionally, it would have an angular resolution 12 times finer than that of Spitzer and three times finer than Herschel. This sensitivity and angular resolution are necessary to perform imaging and spectroscopic studies of individual galaxies in the early universe. We have considered many aspects of the SAFIR mission, including the telescope technology (optical design, materials, and packaging), detector needs and technologies, cooling method and required technology developments, attitude and pointing, power systems, launch vehicle, and mission operations. The most challenging requirements for this mission are operating temperature and aperture size of the telescope, and the development of detector arrays. SAFIR can take advantage of much of the technology under development for JWST, but with much less stringent requirements on optical accuracy.

Benford, Dominic J.↗

A SAFIR Mission Concept

The development of a large far-infrared telescope in space has taken on a new urgency with the recognition of the fundamental importance of the far-infrared spectral region to questions ranging from cosmology to our own Solar System. The Single Aperture Far-InfraRed (SAFIR) Observatory is a l0m-class far-infrared observatory that would begin development later in this decade to answer these questions. SAFIR's science goals are driven by the fact that youngest stages of almost all phenomena in the universe are shrouded in absorption by and emission from cool dust that emits strongly in the far- infrared, 20 microns - 1 millimeter. Its operating temperature of 4 K and its capable instrument complement would be optimized to reach the natural sky background limit in the far-infrared with diffraction-limited performance down to around 40 microns. This would provide a point source sensitivity improvement of several orders of magnitude over that of SIRTF. Based on a broad set of science requirements, we have developed a conceptual design for the SAFIR observatory using design heritage from the James Webb Space Telescope. Several enabling technologies requiring development have been identified, including lightweight deployable optics, cryogenic cooling of optical elements and instruments, and large arrays of sensitive detectors.

Benford, Dominic J.↗

Thunderstorm monitoring and lightning warning, operational applications of the Safir system

During the past years a new range of studies have been opened by the application of electromagnetic localization techniques to the field of thunderstorm remote sensing. VHF localization techniques were used in particular for the analysis of lightning discharges and gave access to time resolved 3-D images of lightning discharges within thunderclouds. Detection and localization techniques developed have been applied to the design of the SAFIR system. This development's main objective was the design of an operational system capable of assessing and warning in real time for lightning hazards and potential thunderstorm hazards. The SAFIR system main detection technique is the long range interferometric localization of thunderstorm electromagnetic activity; the system performs the localization of intracloud and cloud to ground lightning discharges and the analysis of the characteristics of the activity.

Richard, Philippe↗

Conceptual design and structural analysis of the spectroscopy of the atmosphere using far infrared emission (SAFIRE) instrument

The conceptual design and structural analysis for the Spectroscopy of the Atmosphere using Far Infrared Emission (SAFIRE) Instrument are provided. SAFIRE, which is an international effort, is proposed for the Earth Observing Systems (EOS) program for atmospheric ozone studies. A concept was developed which meets mission requirements and is the product of numerous parametric studies and design/analysis iterations. Stiffness, thermal stability, and weight constraints led to a graphite/epoxy composite design for the optical bench and supporting struts. The structural configuration was determined by considering various mounting arrangements of the optical, cryo, and electronic components. Quasi-static, thermal, modal, and dynamic response analyses were performed, and the results are presented for the selected configuration.

Moses, Robert W.↗