Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAFIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Quantum noise properties of CT images with anatomical textured backgrounds across reconstruction algorithms: FBP and SAFIRE

Purpose: Quantum noise properties of CT images are generally assessed using simple geometric phantoms with uniform backgrounds. Such phantoms may be inadequate when assessing nonlinear reconstruction or postprocessing algorithms. The purpose of this study was to design anatomically informed textured phantoms and use the phantoms to assess quantum noise properties across two clinically available reconstruction algorithms, filtered back projection (FBP) and sinogram affirmed iterative reconstruction (SAFIRE). Methods: Two phantoms were designed to represent lung and soft-tissue textures. The lung phantom included intricate vessel-like structures along with embedded nodules (spherical, lobulated, and spiculated). The soft tissue phantom was designed based on a three-dimensional clustered lumpy background with included low-contrast lesions (spherical and anthropomorphic). The phantoms were built using rapid prototyping (3D printing) technology and, along with a uniform phantom of similar size, were imaged on a Siemens SOMATOM Definition Flash CT scanner and reconstructed with FBP and SAFIRE. Fifty repeated acquisitions were acquired for each background type and noise was assessed by estimating pixel-value statistics, such as standard deviation (i.e., noise magnitude), autocorrelation, and noise power spectrum. Noise stationarity was also assessed by examining the spatial distribution of noise magnitude. The noise properties were compared across background types and between the two reconstruction algorithms. Results: In FBP and SAFIRE images, noise was globally nonstationary for all phantoms. In FBP images of all phantoms, and in SAFIRE images of the uniform phantom, noise appeared to be locally stationary (within a reasonably small region of interest). Noise was locally nonstationary in SAFIRE images of the textured phantoms with edge pixels showing higher noise magnitude compared to pixels in more homogenous regions. For pixels in uniform regions, noise magnitude was reduced by an average of 60% in SAFIRE images compared to FBP. However, for edge pixels, noise magnitude ranged from 20% higher to 40% lower in SAFIRE images compared to FBP. SAFIRE images of the lung phantom exhibited distinct regions with varying noise texture (i.e., noise autocorrelation/power spectra). Conclusions: Quantum noise properties observed in uniform phantoms may not be representative of those in actual patients for nonlinear reconstruction algorithms. Anatomical texture should be considered when evaluating the performance of CT systems that use such nonlinear algorithms.

60 APPLIED LIFE SCIENCES↗

Comparison of image noise and image quality between full-dose abdominal computed tomography scans reconstructed with weighted filtered back projection and half-dose scans reconstructed with improved sinogram-affirmed iterative reconstruction (SAFIRE*)

Purpose: To retrospectively compare the image noise, signal-to-noise ratio (SNR), and subjective image quality between CT images acquired with a dual-source, split-dose imaging protocol reconstructed at full and half doses with weighted filtered back projection (wFBP) and an improved sinogram-affirmed iterative reconstruction algorithm (SAFIRE*). Methods: Fifty-three consecutive patients underwent contrast-enhanced CT of the abdomen using a standardized dual-source, single energy CT protocol. Half-dose images were retrospectively generated using data from one detector only. Full-dose datasets were reconstructed with wFBP, while half-dose datasets were reconstructed with wFBP and SAFIRE* strengths 1–5. Region of interest analysis was performed to assess SNR and noise. Diagnostic acceptability, subjective noise, and spatial resolution were graded on a 10-point scale by two readers. Statistical analysis was carried out with repeated measures analysis of variance, Wilcoxon signed rank test, and Cohen’s κ test. Results: With the increasing strengths of SAFIRE*, a progressive reduction in noise and increase in SNR (p < 0.01) was observed. There was a statistically significant decrease in objective noise and increase in SNR in half-dose SAFIRE* strength 4 and 5 reconstructions compared to full-dose reconstructions using wFBP (p < 0.01). Qualitative analysis revealed a progressive increase in diagnostic acceptability, decrease in subjective noise and increase in spatial resolution for half-dose images reconstructed with the increasing strengths of SAFIRE* (p < 0.01). Conclusions: Half-dose CT images reconstructed with SAFIRE* at strength 4 and 5 have superior image quality compared to full-dose images reconstructed with wFBP. SAFIRE* potentially allows dose reductions in the order of 50% over wFBP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SAFIRE : Scalable and Accurate Fault Injection for Parallel Multi-threaded Applications

The software SAFIRE implements a fault injection tool to evaluate the impact of soft errors on parallel, multi-threaded applications. It implements instruction-level fault models that emulate soft errors by flipping bits in the register operands of executed machine instructions. SAFIRE is based on the LLVM compiler and utilizes novel techniques to optimize instruction instrumentation and fault injection. By detailed measurements, SAFIRE is multiple times faster than other state-of-the-art fault injection techniques, while having the same accuracy.

Georgakoudis, Giorgis↗

SAFIRE 2011

SAFIRE is used to mock up a fireset used for arming and firing explosive devices. In SAFIRE 2011 a Microsoft Visio TM style drag and drop interface is used that allows and arming, firing, and fuzing engineer to drag the components needed to develop a fireset (batteries, capacitors, triggers, .. . ) on to a canvas and then connect the components together. Once a valid fireset is constructed on the canvas the speed of the fireset is calculated to indicate time it would require the armed fireset to function. This function time is then compared against a list of built in, and user added disablement tools to indicate how close to the device the disablement tool would have to be to disable the fireset before it could function. User can further generate a report that describes the fireset, provides a diagram of it, gives function and disablement tool values, and additional user

Source record↗

Safire-Safe impact resistant electrolyte

The goal of this project is to demonstrate the feasibility of the SAFIRE concept in transportation batteries and demonstrate a pathway to incorporate this technology into existing battery manufacturing processes. When successful we will have demonstrated a method to make electrolytes safer for transportation applications. This increased safety will enable us to reduce the mass associated with the impact protection systems incorporated within vehicles thereby increasing the vehicles range.

25 ENERGY STORAGE↗

The Acceptability of Iterative Reconstruction Algorithms in Head CT: An Assessment of Sinogram Affirmed Iterative Reconstruction (SAFIRE) vs. Filtered Back Projection (FBP) Using Phantoms

Computed tomography (CT) is the primary imaging investigation for many neurologic conditions with a proportion of patients incurring cumulative doses. Iterative reconstruction (IR) allows dose optimization, but head CT presents unique image quality complexities and may lead to strong reader preferences.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-P-45: Clinical Experience with Radiation Dose Reduction of CT Examinations Using Iterative Reconstruction Algorithms

Purpose: Iterative reconstruction (IR) algorithms have been adopted by medical centers in the past several years. IR has a potential to substantially reduce patient dose while maintaining or improving image quality. This study characterizes dose reductions in clinical settings for CT examinations using IR. Methods: We retrospectively analyzed dose information from patients who underwent abdomen/pelvis CT examinations with and without contrast media in multiple locations of our Healthcare system. A total of 743 patients scanned with ASIR on 64 slice GE lightspeed VCTs at three sites, and 30 patients scanned with SAFIRE on a Siemens 128 slice Definition Flash in one site was retrieved. For comparison, patient data (n=291) from a GE scanner and patient data (n=61) from two Siemens scanners where filtered back-projection (FBP) was used was collected retrospectively. 30% and 10% ASIR, and SAFIRE Level 2 was used. CTDIvol, Dose-length-product (DLP), weight and height from all patients was recorded. Body mass index (BMI) was calculated accordingly. To convert CTDIvol to SSDE, AP and lateral dimensions at the mid-liver level was measured for each patient. Results: Compared with FBP, 30% ASIR reduces dose by 44.1% (SSDE: 12.19mGy vs. 21.83mGy), while 10% ASIR reduced dose by 20.6% (SSDE 17.32mGy vs. 21.83). Use of SAFIRE reduced dose by 61.4% (SSDE: 8.77mGy vs. 22.7mGy). The geometric mean for patients scanned with ASIR was larger than for patients scanned with FBP (geometric mean is 297.48 mmm vs. 284.76 mm). The same trend was observed for the Siemens scanner where SAFIRE was used (geometric mean: 316 mm with SAFIRE vs. 239 mm with FBP). Patient size differences suggest that further dose reduction is possible. Conclusion: Our data confirmed that in clinical practice IR can significantly reduce dose to patients who undergo CT examinations, while meeting diagnostic requirements for image quality.

60 APPLIED LIFE SCIENCES↗

THE SPITZER ARCHIVAL FAR-INFRARED EXTRAGALACTIC SURVEY

We present the Spitzer Archival Far-InfraRed Extragalactic Survey (SAFIRES). This program produces refined mosaics and source lists for all far-infrared (FIR) extragalactic data taken during the more than six years of the cryogenic operation of the Spitzer Space Telescope. The SAFIRES products consist of FIR data in two wavelength bands (70 and 160 μm) across approximately 180 square degrees of sky, with source lists containing far-infrared fluxes for almost 40,000 extragalactic point sources. Thus, SAFIRES provides a large, robust archival far-infrared data set suitable for many scientific goals.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-I-82: Improving CT Image Quality for Radiation Therapy Using Iterative Reconstruction Algorithms and Slightly Increasing Imaging Doses

Purpose: Iterative reconstruction (IR) algorithms are developed to improve CT image quality (IQ) by reducing noise without diminishing spatial resolution or contrast. For CT in radiation therapy (RT), slightly increasing imaging dose to improve IQ may be justified if it can substantially enhance structure delineation. The purpose of this study is to investigate and to quantify the IQ enhancement as a result of increasing imaging doses and using IR algorithms. Methods: CT images were acquired for phantoms, built to evaluate IQ metrics including spatial resolution, contrast and noise, with a variety of imaging protocols using a CT scanner (Definition AS Open, Siemens) installed inside a Linac room. Representative patients were scanned once the protocols were optimized. Both phantom and patient scans were reconstructed using the Sinogram Affirmed Iterative Reconstruction (SAFIRE) and the Filtered Back Projection (FBP) methods. IQ metrics of the obtained CTs were compared. Results: IR techniques are demonstrated to preserve spatial resolution as measured by the point spread function and reduce noise in comparison to traditional FBP. Driven by the reduction in noise, the contrast to noise ratio is doubled by adopting the highest SAFIRE strength. As expected, increasing imaging dose reduces noise for both SAFIRE and FBP reconstructions. The contrast to noise increases from 3 to 5 by increasing the dose by a factor of 4. Similar IQ improvement was observed on the CTs for selected patients with pancreas and prostrate cancers. Conclusion: The IR techniques produce a measurable enhancement to CT IQ by reducing the noise. Increasing imaging dose further reduces noise independent of the IR techniques. The improved CT enables more accurate delineation of tumors and/or organs at risk during RT planning and delivery guidance.

60 APPLIED LIFE SCIENCES↗

SU-E-I-04: Improving CT Quality for Radiation Therapy of Patients with High Body Mass Index Using Iterative Reconstruction Algorithms

Purpose: Iterative reconstruction (IR) algorithms are developed to improve CT image quality (IQ) by reducing noise without diminishing spatial resolution or contrast. The CT IQ for patients with a high Body Mass Index (BMI) can suffer from increased noise due to photon starvation. The purpose of this study is to investigate and to quantify the IQ enhancement for high BMI patients through the application of IR algorithms. Methods: CT raw data collected for 6 radiotherapy (RT) patients with BMI, greater than or equal to 30 were retrospectively analyzed. All CT data were acquired using a CT scanner (Somaton Definition AS Open, Siemens) installed in a linac room (CT-on-rails) using standard imaging protocols. The CT data were reconstructed using the Sinogram Affirmed Iterative Reconstruction (SAFIRE) and Filtered Back Projection (FBP) methods. IQ metrics of the obtained CTs were compared and correlated with patient depth and BMI. The patient depth was defined as the largest distance from anterior to posterior along the bilateral symmetry axis. Results: IR techniques are demonstrated to preserve contrast and reduce noise in comparison to traditional FBP. Driven by the reduction in noise, the contrast to noise ratio is roughly doubled by adopting the highest SAFIRE strength. A significant correlation was observed between patient depth and IR noise reduction through Pearson’s correlation test (R = 0.9429/P = 0.0167). The mean patient depth was 30.4 cm and the average relative noise reduction for the strongest iterative reconstruction was 55%. Conclusion: The IR techniques produce a measureable enhancement to CT IQ by reducing the noise. Dramatic noise reduction is evident for the high BMI patients. The improved CT IQ enables more accurate delineation of tumors and organs at risk and more accuarte dose calculations for RT planning and delivery guidance. Supported by Siemens.

60 APPLIED LIFE SCIENCES↗

Parallel-scanning tomosynthesis using a slot scanning technique: Fixed-focus reconstruction and the resulting image quality

Purpose: Parallel-scanning tomosynthesis (PS-TS) is a novel technique that fuses the slot scanning technique and the conventional tomosynthesis (TS) technique. This approach allows one to obtain long-view tomosynthesis images in addition to normally sized tomosynthesis images, even when using a system that has no linear tomographic scanning function. The reconstruction technique and an evaluation of the resulting image quality for PS-TS are described in this paper. Methods: The PS-TS image-reconstruction technique consists of several steps (1) the projection images are divided into strips, (2) the strips are stitched together to construct images corresponding to the reconstruction plane, (3) the stitched images are filtered, and (4) the filtered stitched images are back-projected. In the case of PS-TS using the fixed-focus reconstruction method (PS-TS-F), one set of stitched images is used for the reconstruction planes at all heights, thus avoiding the necessity of repeating steps (1)–(3). A physical evaluation of the image quality of PS-TS-F compared with that of the conventional linear TS was performed using a R/F table (Sonialvision safire, Shimadzu Corp., Kyoto, Japan). The tomographic plane with the best theoretical spatial resolution (the in-focus plane, IFP) was set at a height of 100 mm from the table top by adjusting the reconstruction program. First, the spatial frequency response was evaluated at heights of −100, −50, 0, 50, 100, and 150 mm from the IFP using the edge of a 0.3-mm-thick copper plate. Second, the spatial resolution at each height was visually evaluated using an x-ray test pattern (Model No. 38, PTW Freiburg, Germany). Third, the slice sensitivity at each height was evaluated via the wire method using a 0.1-mm-diameter tungsten wire. Phantom studies using a knee phantom and a whole-body phantom were also performed. Results: The spatial frequency response of PS-TS-F yielded the best results at the IFP and degraded slightly as the distance from the IFP increased. A visual evaluation of the spatial resolution using the x-ray test pattern indicated that the resolution was 1.8 lp/mm at the IFP and 1.2 lp/mm at heights of −100 and 100 mm from the IFP. The authors demonstrated that a spatial resolution of 1.2–1.8 lp/mm could be obtained within heights of 200 mm of the IFP. The slice sensitivity varied between 11.1 and 13.8 mm for heights between −50 and 100 mm, and there was no critical change in the slice sensitivity within a height range of 150 mm around the IFP. The phantom results demonstrated that tomosynthesis and long-view images could be reconstructed. Conclusions: PS-TS-F provides tomosynthesis images while using low-cost systems that have no tomographic scanning function, such as tableside-controlled universal R/F systems or universal radiographic systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Note: Measuring contrast- and noise-dependent spatial resolution of an iterative reconstruction method in CT using ensemble averaging

Purpose: The spatial resolution of iterative reconstruction (IR) in computed tomography (CT) is contrast- and noise-dependent because of the nonlinear regularization. Due to the severe noise contamination, it is challenging to perform precise spatial-resolution measurements at very low-contrast levels. The purpose of this study was to measure the spatial resolution of a commercially available IR method using ensemble-averaged images acquired from repeated scans. Methods: A low-contrast phantom containing three rods (7, 14, and 21 HU below background) was scanned on a 128-slice CT scanner at three dose levels (CTDI{sub vol} = 16, 8, and 4 mGy). Images were reconstructed using two filtered-backprojection (FBP) kernels (B40 and B20) and a commercial IR method (sinogram affirmed iterative reconstruction, SAFIRE, Siemens Healthcare) with two strength settings (I40-3 and I40-5). The same scan was repeated 100 times at each dose level. The modulation transfer function (MTF) was calculated based on the edge profile measured on the ensemble-averaged images. Results: The spatial resolution of the two FBP kernels, B40 and B20, remained relatively constant across contrast and dose levels. However, the spatial resolution of the two IR kernels degraded relative to FBP as contrast or dose level decreased. For a given dose level at 16 mGy, the MTF{sub 50%} value normalized to the B40 kernel decreased from 98.4% at 21 HU to 88.5% at 7 HU for I40-3 and from 97.6% to 82.1% for I40-5. At 21 HU, the relative MTF{sub 50%} value decreased from 98.4% at 16 mGy to 90.7% at 4 mGy for I40-3 and from 97.6% to 85.6% for I40-5. Conclusions: A simple technique using ensemble averaging from repeated CT scans can be used to measure the spatial resolution of IR techniques in CT at very low contrast levels. The evaluated IR method degraded the spatial resolution at low contrast and high noise levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Residential HVAC Fault Data Collection Plan – Refrigerant Undercharge and Overcharge Faults

Heating, ventilation, and air-conditioning (HVAC) systems can develop faults due to poor installation practices or gradual wear and tear, leading to decreased HVAC system’s efficiency, compromised thermal comfort, and shortened equipment lifespan (EERE, 2018). Automated fault detection and diagnosis (AFDD) technologies offer a solution by identifying energy-wasting HVAC faults, such as inadequate indoor airflow and incorrect refrigerant charge, and guiding technicians to enhance system efficiency. In the realm of residential HVAC, AFDD can be implemented through various fault detection and diagnosis capabilities, sensor configurations, and target applications. These technologies typically fall into three categories: smart diagnostic tools, original equipment manufacturer (OEM)-embedded tools, and add-on tools. Smart diagnostic tools employ temporarily installed sensors to directly measure HVAC system characteristics, while OEM-embedded tools utilize factory-installed sensors to identify faults or assess system performance. However, both these types of AFDD technologies are often only accessible for high-end HVAC equipment or require additional sensor installation by qualified technicians, resulting in high investment costs and limited applicability for low-income residential buildings. On the other hand, add-on tools rely solely on data from smart thermostats and meters to detect faults by continuously analyzing equipment runtime or energy usage. As smart thermostat and meter costs decrease and their prevalence increases, these tools can be readily deployed in low-income residential buildings. However, they possess limited capabilities as they rely solely on basic trend analysis. Enhancing such tools with advanced machine learning algorithms can significantly improve their effectiveness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydronic Shell: An Affordable Solution for Multifamily Deep Energy Retrofit

Approximately 42% of multi-family buildings in the United States have do not have insulation as required by the building codes. Envelope retrofits of these buildings are needed to improve their thermal performance, provide thermal resilience, and enable a pathway to electrification of space heating systems. Hydronic shell (HS) is a retrofit technique where a stud wall layer is added to a masonry wall along with a convective coil and a fan coil unit fitted in the façade cavity which can provide both heating and cooling to the space. The HS system serves a dual purpose of 1) retrofitting the building envelope and 2) retrofitting the HVAC system and enabling electrification of space heating. The electrification of space heating is possible from the installation of a combination of hydronic system/fan coil unit system which uses a central heat pump as a source of heating water in the cavity between the existing wall and retrofit insulation layer. This study evaluates the performance of the HS system at varying outdoor conditions mimicked by a climate chamber and hot water supply temperature from a water bath. During the ramp-up period, the indoor chamber temperature could be increased from 66 ºF to 69.5 ºF within an hour using heating water at 120 ºF when the outdoor chamber temperature was at 0 ºF. When the indoor chamber temperature was maintained within a deadband, variation in cavity air temperature was mostly influenced by the duration when water was flowing through the cavity convector. It was seen from the testing that the hydronic system alone without use of fan in the system is able to maintain the space temperature at coldest outdoor condition used in the experiment (0 ºF) even at lowest hot water supply temperature chosen (90 ºF). During the ramp-down period, the fastest decline in temperature took 6.4 hours from temperature to drop from 69.6 ºF to 66 ºF which shows tremendous potential of thermal resilience and peak load shifting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗