Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Pneumatic Sampler (P-Sampler) for the Martian Moons Exploration (MMX)

The Martian Moons eXploration (MMX) mission, led by the Japanese Aerospace Exploration Agency (JAXA), will focus on the exploration of the two Martian moons – Phobos and Deimos (Figure 1). The spacecraft will perform close-up remote sensing and observations of both moons and collect a sample from Phobos for Earth sample return. MMX has set the two mission goals: (1) determining the origin of the Martian moons and (2) observing processes in the circumplanetary environment of Mars, based on remote sensing, in-situ observations, and laboratory analyses of returned samples of Phobos regolith [1-2]. To fulfill the mission goals, MMX employs a double sampling approach: Coring and Pneumatic Samplers (Figure 2).The Coring Sampler (C-Sampler), a core soil tube deployed by a robotic arm, providing access to the building blocks of Phobos beneath the surface (>2 cm), and also collect a mixture of near surface material. The P-Sampler, on the other hand, would selectively sample the surface veneer and provides reference of surface component with the C-Sampler. The double sampling system not only enhances the scientific merits of MMX but also reduces risks associated with the sampling of Phobos. Without enough knowledge of the physical and chemical properties, and the geotechnical conditions of the surface of Phobos (e.g., compositions, temperature gradient/variation, porosity, grain size distribution), having two sampling systems that utilize entirely different sampling approaches is prudent.

Dylan Van Dyne↗

Pneumatic Sampler (P-Sampler) for the Martian Moons Exploration (MMX)

A Pneumatic Sampler (P-SMP)is being provided by Honeybee Robotics with support from NASA Planetary Missions Program Office (PMPO)for JAXA’s Martian Moons eXploration (MMX) mission. The goal of this mission is to closely survey the Martian moons Deimos and Phobos, and then to collect regolith from Phobos and return it to Earth. The P-SMP will be mounted to a leg of the lander and will be responsible for collecting surface regolith alongside the JAXA provide Core Sampler (C-SMP). The Sampling Funnel of the P-SMP utilizes two sets of sampling nozzles: one set of nozzles pointed directly at the surface to kick-up and loft material into the sampling head, and a second set of nozzles to direct the oncoming material into the sample return canister further up the lander leg. A robotic arm mounted underneath the lander will then remove the sample canister and place it inside the sample return capsule for Earth return. Several iterations of the P-Sampler have been designed and tested inside a vacuum chamber with Phobos regolith simulant. In all tests, the P-Sampler successfully acquired the sample, even in an extreme scenario where the sampling head was mounted 10 cm above a surface covered with gravel.

Dylan Van Dyne↗

Multispectral Resource Sampler (MRS): Proof of concept study on atmospheric corrections. Determinations of atmospheric optical parameters using the multispectral resource sampler atmospheric optical

An investigation was performed to determine which mathematical algorithms should be used in the calculation of atmospheric optical parameters using the Multispectral Resource Sampler (MRS) sensor. A simulation of the MRS sensor was performed using a radiative-transfer model. The simulation provides the spectral radiance at the satellite sensor in terms of various atmospheric parameters, such as optical thickness, solar zenith angle, nadir view angle, relative azimuth angle, bi-directional reflectance of the target, background albedo, and wavelength. Atmospheric correction algorithms were also developed for the determination of the total spectral optical thickness of the atmosphere for: (1) homogeneous (horizontal) hazy atmospheres with diffuse targets; (2) inhomogeneous (horizontal) hazy atmospheres with diffuse targets; and (3) homogeneous (horizontal) hazy atmospheres with non-diffuse targets.

Turner, R. E.↗

PNEUMATIC SAMPLER (P-SAMPLER) FOR THE MARTIAN MOONS EXPLORATION (MMX)

The Martian Moons eXploration (MMX) mission, led by the Japanese Aerospace Exploration Agency (JAXA), will focus on the exploration of the two Martian moons – Phobos and Deimos . The spacecraft will perform close-up remote sensing and observations of both moons, and collect a sample from Phobos for Earth sample return. MMX has set the two mission goals: (1) determining the origin of the Martian moons and (2) observing processes in the circumplanetary environment of Mars, based on remote sensing, in-situ observations, and laboratory analyses of returned Phobos regolith.

D. Van Dyne↗

Pneumatic Sampler (P-SAMPLER) for the Martian Moons Exploration (MMX)

The Martian Moons eXploration (MMX) mission, led by the Japanese Aerospace Exploration Agency (JAXA), will focus on the exploration of the two Martian moons – Phobos and Deimos (). The spacecraft will perform close-up remote sensing and observations of both moons, and collect a sample from Phobos for Earth sample return.

D Van Dyne↗

Evaluation of portable air samplers for monitoring airborne culturable bacteria

Airborne culturable bacteria were monitored at five locations (three in an office/laboratory building and two in a private residence) in a series of experiments designed to compare the efficiency of four air samplers: the Andersen two-stage, Burkard portable, RCS Plus, and SAS Super 90 samplers. A total of 280 samples was collected. The four samplers were operated simultaneously, each sampling 100 L of air with collection on trypticase soy agar. The data were corrected by applying positive hole conversion factors for the Burkard portable, Andersen two-stage, and SAS Super 90 air samplers, and were expressed as log10 values prior to statistical analysis by analysis of variance. The Burkard portable air sampler retrieved the highest number of airborne culturable bacteria at four of the five sampling sites, followed by the SAS Super 90 and the Andersen two-stage impactor. The number of bacteria retrieved by the RCS Plus was significantly less than those retrieved by the other samplers. Among the predominant bacterial genera retrieved by all samplers were Staphylococcus, Bacillus, Corynebacterium, Micrococcus, and Streptococcus.

NASA Center JSC↗

Evaluation of three portable samplers for monitoring airborne fungi

Airborne fungi were monitored at five sample sites with the Burkard portable, the RCS Plus, and the SAS Super 90 air samplers; the Andersen 2-stage impactor was used for comparison. All samplers were calibrated before being used simultaneously to collect 100-liter samples at each site. The Andersen and Burkard samplers retrieved equivalent volumes of airborne fungi; the SAS Super 90 and RCS Plus measurements did not differ from each other but were significantly lower than those obtained with the Andersen or Burkard samplers. Total fungal counts correlated linearly with Cladosporium and Penicillium counts. Alternaria species, although present at all sites, did not correlate with total count or with amounts of any other fungal genera. Sampler and location significantly influenced fungal counts, but no interactions between samplers and locations were found.

NASA Center JSC↗

Solid sorbent air sampler

A fluid sampler for collecting a plurality of discrete samples over separate time intervals is described. The sampler comprises a sample assembly having an inlet and a plurality of discreet sample tubes each of which has inlet and outlet sides. A multiport dual acting valve is provided in the sampler in order to sequentially pass air from the sample inlet into the selected sample tubes. The sample tubes extend longitudinally of the housing and are located about the outer periphery thereof so that upon removal of an enclosure cover, they are readily accessible for operation of the sampler in an analysis mode.

Galen, T. J.↗

Efficiency tests of samplers for microbiological aerosols, a review

To obtain comparable results from studies using a variety of samplers of microbiological aerosols with different collection performances for various particle sizes, methods reported in the literature were surveyed, evaluated, and tabulated for testing the efficiency of the samplers. It is concluded that these samplers were not thoroughly tested, using reliable methods. Tests were conducted in static air chambers and in various outdoor and work environments. Results are not reliable as it is difficult to achieve stable and reproducible conditions in these test systems. Testing in a wind tunnel is recommended.

Henningson, E.↗

Propagation delay measurements from a timing sampler intended for use in space

A 3-micron CMOS timing sampler is described which is a test circuit designed into the Jet Propulsion Labs' CRRES chip to be flown on the Combined Release and Radiation Effects Satellite (CRRES). The timing sampler consists of 64 inverter-pair stages with sampling latches and decoder circuitry. The sampler is used to measure inverter-pair propagation delays, which are nominally 2.5 ns, with a resolution of 100 ps. A simple model was developed to explain the radiation-induced inverter-pair delay shifts in terms of radiation-induced MOSFET threshold-voltage shifts and effective modal capacitances. The magnitude of the shift in pair delay with radiation was estimated at the point where the n-MOSFET threshold voltage became zero. For a 0.7-V-threshold shift, the pair delay increased from its preradiation value by 360 ps for a rising step input and decreased by 190 ps for a falling step input.

Blaes, B. R.↗

Active Hydrazine Vapor Sampler (AHVS)

The Active Hydrazine Vapor Sampler (AHVS) was developed to detect vapors of hydrazine (HZ) and monomethylhydrazine (MMH) in air at parts-per-billion (ppb) concentration levels. The sampler consists of a commercial personal pump that draws ambient air through paper tape treated with vanillin (4-hydroxy-3-methoxybenzaldehyde). The paper tape is sandwiched in a thin cardboard housing inserted in one of the two specially designed holders to facilitate sampling. Contaminated air reacts with vanillin to develop a yellow color. The density of the color is proportional to the concentration of HZ or MMH. The AHVS can detect 10 ppb in less than 5 minutes. The sampler is easy to use, low cost, and intrinsically safe and contains no toxic material. It is most beneficial for use in locations with no laboratory capabilities for instrumentation calibration. This paper reviews the development, laboratory test, and field test of the device.

Young, Rebecca C.↗

Hydrothermal Vent Sampler: Does Life Exist in High Temperature Environments?

The main purpose of this research is to search for the existence of biomass under extreme temperature and pressure conditions to determine the upper bounds of environments on which life can exist. Vents are, simply put, underwater volcano openings located at the bottom of the sea. The conditions at these locations are considerably extreme with pressures of up to 10,000 psi, and enormous temperature gradients. The temperature of the water near these vents is around 400 C, while that of the surrounding water is about 3 C. The extremity of these conditions makes it hard to estimate the existence of life in those environments. I n order to find whether such existence happens, we need to search for biomass inside these vents. The vent sampler is a device that has the purpose of safely and accurately collecting this biomass for examination. This sampler is constituted of a Series of filters of the order of 100-0.2 microns in size. Since this is a 3-year project, it has not concluded yet; however, during the time I contributed to this project, I worked with the mechanical design of this sampler device including the selection, assembly, and testing of the various subsystems and the design and construction of the electronics enclosure.

Rivadeneyra, Cesar R.↗

A lightweight, high output soil sampler

Sampler is useful on or under earth's surface or on sea bottom. Larger sample amount is obtained relative to sampler size and weight and limited particle size sample material is continuously delivered. Silicone rubber linear in transport tube nearly eliminates grinding or particulate processing during sampling, and reduces required torque.

Howard, E. A.↗

Improved high volume air sampler

Sampler permits size separations of particles by directing sampled air through cross-sectional area sufficiently large that air velocity is reduced to point where particles or larger size will settle out. Sampler conducts air downward and through slots around periphery of unit into relatively open interior of house.

King, R. B.↗

The Viking surface sampler

A surface sampler subsystem for the Viking Lander has been designed, fabricated, cleaned, and successfully tested. Testing has included component level tests to qualification environment and subsystem level tests. This development hardware has also been integrated into a System Test Bed (STB) for the lander system. In addition to the normal dynamic and thermal environments the surface sampler hardware has been tested in an aircraft to simulate the effects of the reduced Martian gravity. Although problems have been encountered with the first-build and integration, the basic design appears to be sound and hardware qualification is scheduled for late 1973.

Seger, R. B.↗

Development and testing of a portable wind sensitive directional air sampler

A portable wind sensitive directional air sampler was developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. The unit, designated Air Scout, receives wind direction signals from an associated wind vane. Air samples are collected on filter slides using a standard high volume air sampler drawing air through a porting arrangement which tracks the wind direction and permits collection of discrete samples. A preset timer controls the length of time each filter is in the sampling position. At the conclusion of the sampling period a new filter is automatically moved into sampling position displacing the previous filter to a storage compartment. Thus the Air Scout may be set up at a field location, loaded with up to 12 filter slides, and left to acquire air samples automatically, according to the wind, at any timer interval desired from 1 to 30 hours.

Deyo, J.↗

Development and testing of a portable wind sensitive directional air sampler

A portable wind-sensitive directional air sampler has been developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. Functional testing of a prototype sampler is described; all items exhibited performance and life sufficient to carry out field performance test operations. Life testing of the wind direction sensor and the directional porting valves, which are critical to reliable operation, was emphasized with successful results.

Deyo, J.↗