Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Modeling the use of mobile modular gas samplers in near-field detection

The Wireless Independent Noble Gas Sampler (WINGS) is a mobile, modular gas sampling system designed for use in low infrastructure environments. In the case of a suspected underground nuclear explosion (UNE), WINGS units could be deployed to detect noble gases emanating from the suspected explosion site or identify gases originating from another source entering the local area from offsite. In conclusion, this work uses the atmospheric transport modeling tool inline WRF-HYSPLIT to test the effectiveness of WINGS units around a suspected UNE site as a function of sampler density and distance from the emission point of gases from a UNE.

Air sampling↗

Comparison of source-location algorithms for atmospheric samplers

Numerous algorithms have been developed to determine the source characteristics for an atmospheric release, e.g., (Bieringer et al., 2017). This study compares three models that have been applied to the data collected by the International Monitoring System operated by the Comprehensive Nuclear-Test-Ban Treaty Preparatory Commission to estimate source event parameters. Each model uses a different approach to estimate the parameters. A deterministic model uses a possible source region (PSR) approach (Ringbom et al., 2014) that is based on the correlation between predicted and measured sample values. An unnamed model developed at Pacific Northwest National Laboratory (herein called BAYEST) uses a Bayesian formulation (Eslinger et al., 2019; Eslinger et al., 2020; Eslinger and Schrom, 2016). The FREAR model uses a different Bayesian formulation (De Meutter and Hoffman, 2020; De Meutter et al., 2021; Pieter De Meutter, 2021). The performance of the three source-location models is evaluated with 100 synthetic release cases for the single xenon isotope, 133 Xe. The release cases resulted in detections in a fictitious network with 120 noble gas samplers. All three source-location models use the same sampling data. The two Bayesian models yield more accurate location estimates than the deterministic PSR model, with FREAR having slightly better location performance than BAYEST. Samplers with collection periods of 3, 6, 8, 12, and 24-h were used. Results from BAYEST show that location accuracy improves with each reduction in sample collection length. The BAYEST model is slightly better for estimating the start time of the release. The PSR model has about the same spread in start times as the FREAR model, but the PSR results have a better average start time. The Bayesian source-location algorithms give more accurate results than the PSR approach, and provide release magnitude estimates, while the base PSR model does not estimate the release magnitude. This investigation demonstrates that a reasonably dense sampling grid will sometimes yield poor location and time estimates regardless of the model. The poor estimates generally coincide with cases where there is a much larger distance between the release point and the first detecting sampler than the average sampler spacing.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Efficient Quantum Gibbs Samplers with Kubo–Martin–Schwinger Detailed Balance Condition

Lindblad dynamics and other open-system dynamics provide a promising path towards efficient Gibbs sampling on quantum computers. In these proposals, the Lindbladian is obtained via an algorithmic construction akin to designing an artificial thermostat in classical Monte Carlo or molecular dynamics methods, rather than being treated as an approximation to weakly coupled system-bath unitary dynamics. Recently, Chen, Kastoryano, and Gilyén (arXiv:2311.09207) introduced the first efficiently implementable Lindbladian satisfying the Kubo–Martin–Schwinger (KMS) detailed balance condition, which ensures that the Gibbs state is a fixed point of the dynamics and is applicable to non-commuting Hamiltonians. This Gibbs sampler uses a continuously parameterized set of jump operators, and the energy resolution required for implementing each jump operator depends only logarithmically on the precision and the mixing time. In this work, we build upon the structural characterization of KMS detailed balanced Lindbladians by Fagnola and Umanità, and develop a family of efficient quantum Gibbs samplers using a finite set of jump operators (the number can be as few as one), akin to the classical Markov chain-based sampling algorithm. Compared to the existing works, our quantum Gibbs samplers have a comparable quantum simulation cost but with greater design flexibility and a much simpler implementation and error analysis. Moreover, it encompasses the construction of Chen, Kastoryano, and Gilyén as a special instance.

97 MATHEMATICS AND COMPUTING↗

Spatiotemporal Changes in Trace Metal Bioavailability in the Sediment Pore water of a Constructed Wetland Using Passive Pore water Samplers

Sediments in aquatic systems often act as a major sink for contaminants. Diffusive gradient in thin films (DGTs) and in situ equilibrium dialysis samplers (peepers) are two major in situ pore water sampling devices that overcome the problems associated with conventional pore water sampling methods. In the present study, DGTs and peepers were used to study the spatial and seasonal effects (cool months, October–February; warm months, May–September) on metal bioavailability in the H‐02 constructed wetland and the sink versus source role of the sediments by calculating the metal resupply capacity. Data showed similar seasonal trends in metal concentrations using passive samplers, peepers, and DGTs. Pooled Cu and Zn concentrations measured using DGTs were lower in warm months (1.67 ± 1.50 and 2.62 ± 0.68 μg L –1 , respectively, p < 0.001) versus in cool months (2.12 ± 0.65 and 5.58 ± 1.33 μg L –1 , respectively, p < 0.001; mean ± 95% confidence interval). Sulfate (SO 4 2− ) concentrations were significantly (p = 0.0139) lower in warm months (averaged at 0.22 ± 0.05 mg L –1 ) compared to in cool months (0.16 ± 0.05 mg L –1 ). The increase in SO 4 2− concentration is an indicator of the lower activity of sulfate‐reducing bacteria, which need SO 4 2− during anaerobic respiration, in which SO 4 2− is reduced to sulfide (S 2– ) that forms insoluble salts with Cu and Zn, which could partially explain the higher bioavailability of these metals in the cool season. Metal resupply capacity of the sediments was mostly <0.2 for Cu and Zn. Taken together, the H0‐2 wetland sediments mostly acted as a sink to both Cu and Zn over the course of the present study. Environ Toxicol Chem 2023;42:2726–2736. © 2023 The Authors. Environmental Toxicology and Chemistry published by Wiley Periodicals LLC on behalf of SETAC.

54 ENVIRONMENTAL SCIENCES↗

Deployment of portable, modular gas samplers as part of an atmospheric tracer experiment

Underground nuclear explosions release noble gases into the atmosphere that can be detected to support international monitoring efforts. Atmospheric transport models help predict the movement of these gases over long distances, but struggle to predict the movement in the atmosphere local to the release. A field experiment was designed to monitor the movement of 127 Xe within a 5-km radius. Four gas samplers were deployed as part of this experiment to collect atmospheric samples at various distances from the release point. In conclusion, these samples were then analyzed in a near-field lab using a NaI detector and in an off-site lab using gamma-gamma coincidence and beta-gamma coincidence counting.

Radioxenon↗

Analysis of measurements from an array of radioxenon samplers near to Hartlepool Nuclear Power Station

As part of a scientific research and development project, the radionuclide fingerprint of an operating advanced gas-cooled reactor 25 (AGR) has been studied across several facets (Goodwin et al., 2024). One part of this project was to deploy an array of 26 radioxenon samplers to the region for a period of around 1 year, to measure any radioxenon emissions from the reactors of the 27 Hartlepool nuclear power station at a range of tens of kilometres away. The array of 3 sensors was operational for around 12 28 months from March 2022 and detected many occurrences of isotopes of radioxenon. Here we provide a detailed analysis and 29 interpretation of the data and where possible, attribution of detections to a source or region. Whilst a key part of this work is to 30 measure any emissions of radioxenon from Hartlepool, this work presents one of the most comprehensive efforts to determine the 31 source of a great number of (mostly) 133Xe detections. A combination of different types of atmospheric dispersion modelling 32 techniques, including the use of stack monitoring data from nearby civil radioxenon-emitting nuclear facilities has enabled the 33 majority of detections to be attributed to one or more possible sources. Whilst emissions from Hartlepool have been detected on 34 the systems, the majority of detections are associated with a medical isotope production facility in Fleurus, Belgium (IRE).

Advanced gas-cooled reactor↗

Bug fixes / enhancements to Parallel tempering Markov chain Monte Carlo sampler (PTMCMCSampler) v3

Markov chain Monte Carlo sampler useful for a variety of problems for optimization, numerical integration, and generating draws from a probability distribution. They are often used in physical and mathematical problems, especially when it is difficult or impossible to use other approaches. This disclosure is for new bug fixes and enhancements to an existing open source library that is already in the public domain under the MIT license. https://github.com/jellis18/PTMCMCSampler

Forrer, Mark↗

Next-Generation Video Ice Particle Sampler Field Campaign Report

The next-generation video ice particle sampler (ngVIPS) was operated on the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s tethered balloon system (TBS) during the IFFExO (Ice Fog Field Experiment at Oliktok Point) project in November, 2020. The purpose of the project was to study ice fog microphysics and the environmental conditions during ice fog to enable better predictions during low-visibility conditions. This project was conducted at the site of the third ARM Mobile Facility (AMF3) at Oliktok Point, Alaska. Among a suite of other instruments, the ngVIPS was operated to observe atmospheric ice particles.

47 OTHER INSTRUMENTATION↗

A summary of air sampler filter performance data: Bladewerx Speclon 5(TM) and Millipore FMLW047 5um

Bladewerx™ LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon 5™ PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon™ filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. Millipore FMLW (5μm) filters are also used at Los Alamos, and a comparison of the two filter types has been requested. For filter face air velocities from 0.066 m/s to 1.5 m/s, the aerosol collection efficiency (for 0.3 μm particle diameters) and the filter pressure drops were measured. The FWHM (full width half maximum) of alpha spectroscopy peaks was also determined, using naturally occurring radon progeny at an alpha energy of 6 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance and automatic calibration scheme of the waveform sampler in the ETROC2 ASIC chip

The waveform sampler in the CMS ETROC2 chip for LGAD gain aging monitoring is a 2.56-GS/s 12-bit 8x-Interleaved ADC that consists of a coarse SAR stage, and a fine stage. This architecture delivers high performance on a relatively modest 65 nm process, while requires finding up to 24 calibration constants through calibration. We developed an automatic calibration method using charge injection test data. After calibration, the baseline random error is reduced by a factor of 2.5–3 compared to the default calibration, and a 5% charge measurement precision is achieved in 15 fC charge injection tests.

Fu, Tao [Unlisted, US]↗

Fast increased fidelity samplers for approximate Bayesian Gaussian process regression

Gaussian processes (GPs) are common components in Bayesian non-parametric models having a rich methodological literature and strong theoretical grounding. The use of exact GPs in Bayesian models is limited to problems containing several thousand observations due to their prohibitive computational demands. We develop a posterior sampling algorithm using H-matrix approximations that scales at O(n log 2 n). We show that this approximation’s Kullback-Leibler divergence to the true posterior can be made arbitrarily small. Though multidimensional GPs could be used with our algorithm, d-dimensional surfaces are modeled as tensor products of univariate GPs to minimize the cost of matrix construction and maximize computational efficiency. We illustrate the performance of this fast increased fidelity approximate GP, FIFA-GP, using both simulated and non-synthetic data sets

97 MATHEMATICS AND COMPUTING↗

Enabling depth resolved temporal resolved soil microbial sampling with novel vadose zone diffusion sampler

To address the difficulty in Earth system science in making time-course measurements of molecular signatures in soil biochemistry, we developed a soil stake system to sample and replace a defined soil analog medium, connected through hydraulic connectivity via perforated casings and modular inserts. We deployed these stakes to a site in Prosser, WA and measured microbial colonization of sterile sand-clay inserts enriched with N-acetyl-glucosamine at different depths over spring and summer. DNA and RNA analyses revealed distinct microbial recruitment and activity patterns. Inserts showed lower microbial diversity but higher abundance of Proteobacteriota and Bacteriota compared to native soils, alongside seasonal shifts in taxonomic and functional profiles. The soil stake system offers a novel approach for studying microbial dynamics across temporal and spatial scales.

58 GEOSCIENCES↗