Prevalence of typical operational problems and energy savings opportunities in U.S. commercial buildings

In the United States, as much as 30% of the 19 EJ that commercial buildings consume is considered excess. Much of the excess energy is due to the inability to manage building operations efficiently. Because almost 20% of the total primary energy consumption is associated with commercial buildings, significant energy reductions in this sector are needed to mitigate climate change. Therefore, many cities and states are mandating periodic “tune-ups” of these buildings to eliminate excess energy consumption. Although the benefits of tune-ups and retro-commissioning are clear, focusing these mandates to look for specific opportunities has been a challenge because of the lack of studies that document the prevalence of opportunities. Therefore, we analyzed building automation system data from 151 buildings across the United States to document common operational problems and opportunities to improve building operations. This analysis showed that opportunities to improve building operations exist in almost every building. These opportunities were not strongly correlated with building vintage or size, but were reflective of how the buildings are operated. The prevalence of the top 20 opportunities ranged between 74% and 23%, with 40% of these associated with air-handling units. The rest of the opportunities are associated with schedules, chilled and hot-water distribution, and zone controls. Of the 151 buildings, 69 of them implemented corrective actions of some or all opportunities that were identified. Implementation varied across the Re-tuning categories, with 60% for schedule opportunities, 50% for zone opportunities, over 40% for the air-handling unit and hot-water opportunities, and 35% of the chilled-water opportunities. There was wide variation in whole building energy savings, ranging from 0 to 50% and 0 to 18 $/m2 with median percent annual whole building savings of 12% and median normalized annual cost savings of $1.75/m2. In addition to documenting these key findings, the paper provides a list of opportunities that can be automatically and continuously identified and corrected and offers a list of those opportunities that should be the focus of the mandates.

Katipamula, Srinivas↗

How To Determine and Verify Operations and Maintenance Savings in Energy Savings Performance Contracts

Operations and maintenance (O&M) savings frequently occur in energy savings performance contracts (ESPCs). During FY 2022, 37% of reported annual cost savings for projects awarded under the U.S. Department of Energy (DOE) ESPC indefinite delivery indefinite quantity (IDIQ) contracts and in the performance period were due to O&M or other energy- and/or water-related cost savings, with the balance (63%) from utility cost savings (i.e., energy or water cost savings). Sometimes the energy- and water-related cost savings are acknowledged and included in payments within ESPCs; other times, for various reasons, they are not. As presented in this guide, FEMP recommends including energy- and water-related cost savings that are O&M (including related repair and replacement) savings in the financial aspects of an ESPC, to the extent such savings can be documented. Inclusion of these savings will help augment project scopes and/or lower interest costs (by shortening financing terms). However, there is a burden of proof as to what constitutes acceptability in O&M savings that needs to be carefully considered and documented in individual projects. Beyond promoting a key tenet used in U.S. federal performance contracting—that savings must be from actual budgets and therefore based on the level of O&M that is actually occurring, not what should have been performed—FEMP also recommends good practice in establishing and documenting O&M baselines, formulating the rationale for baseline adjustments during the performance period, and conducting ongoing verification activities. This document concludes with five examples of how O&M savings may be handled, in situations ranging from the partial displacement of O&M contracts to consolidation and “virtualization” of servers in data centers. A key theme that permeates this guide is the importance of thoroughly documenting all conditions and assumptions used in the development of and accounting for O&M costs and savings throughout the ESPC life cycle, from baseline-setting to measurement and verification (M&V) of the savings during each year of the performance period. Doing so not only prevents internal claims of non-performance (especially in the case of staff turnover during the contract term), but also simplifies ordering agency and energy service company (ESCO) response in the event of scrutiny from oversight organizations, such as government audits. While this guide focuses on federal ESPCs, it may also be applicable when O&M savings are included in utility energy service contracts (UESCs) and non-federal ESPCs.

Voss, Phil↗

Quantifying adoption rates and energy savings over time for advanced energy-efficient manufacturing technologies

Energy-efficient manufacturing technologies can reduce energy consumption and lower operating costs for manufacturing facilities, but up-front costs and increased process complexity frequently lead to manufacturers being reluctant to adopt such technologies. To avoid overestimating the benefits of advanced energy-efficient manufacturing technologies, it is necessary to account for how quickly and how widely the technology will be adopted by manufacturers. This work develops a method for estimating manufacturing technology adoption rates using quantitative technology characteristics including energetic, economic, and technical criteria that capture both incentives (such as energy and cost savings) and disincentives (such as increased process complexity) for technology adoption. This method is unique in that it can be applied before or after a technology reaches the market; other adoption rate estimation methods require sales data and can only be applied post-market. Eleven technology characteristics are considered, with each characteristic weighted to reflect its impact on the overall technology adoption rate. Technology characteristic data is used to estimate model parameters for the Bass diffusion curve, which quantifies the change in the number of new technology adopters in a population over time. Finally, energy savings at the sector level are calculated over time by multiplying the number of new technology adopters at each time step with the technology’s facility-level energy savings. The proposed method is demonstrated with an application to glass industry manufacturing technologies using technology data obtained from the U.S. Department of Energy's 2017 bandwidth study. The potential energy savings for each technology and the rate at which each technology is adopted in the sector are quantified and used to identify the technologies which offer the greatest cumulative sector-level energy savings over a period of 20 years.

advanced manufacturing↗

A simple tool for estimating city-wide annual electrical energy savings from cooler surfaces

We present a simple method to estimate the maximum possible electrical energy saving that might be achieved by increasing the albedo of surfaces in a large city. We restrict this to the “indirect effect”, the cooling of outside air that lessens the demand for air conditioning (AC). Given the power demand of the electric utilities and data about the city, we can use a single linear equation to estimate the maximum savings. For example, the result for an albedo change of 0.2 of pavements in a typical warm city in California, such as Sacramento, is that the saving is less than about 2 kWh per m2 per year. This may help decision makers choose which heat island mitigation techniques are economical from an energy-saving perspective.

Pomerantz, Melvin↗

Potential Heating Energy and Cost Savings of Dual Fuel Heat Pump Controls as a Residential Building Equipment Retrofit in the U.S.

This study investigated the energy and cost savings potential by modeling a dual fuel heat pump system with its control for a residential building in (5A) cold climate in U.S. The simulation analysis showed that the application of the DFHP system and its control to the target building can save the heating energy by 42% over a gas furnace system (baseline system). Although the HP-only system can save more heating energy (i.e., 53%) over the baseline system than DFHP system does, the DFHP with its control demonstrated the higher cost savings when a time of use electricity rate was considered.

Yoon, Yeobeom↗

Energy and emissions saving potential of additive manufacturing: the case of lightweight aircraft components

Additive manufacturing (AM) holds great potential for improving materials efficiency, reducing life-cycle impacts, and enabling greater engineering functionality compared to conventional manufacturing (CM), and AM has been increasingly adopted by aircraft component manufacturers for lightweight, cost-effective designs. This study estimates the net changes in life-cycle primary energy and greenhouse gas emissions associated with AM technologies for lightweight metallic aircraft components through the year 2050, to shed light on the environmental benefits of a shift from CM to AM processes in the U.S. aircraft industry. A systems modeling framework is presented, with integrates engineering criteria, life-cycle environmental data, aircraft fleet stock and fuel use models under different AM adoption scenarios. Estimated fleet-wide life-cycle primary energy savings at most reach 70-173 million GJ/year in 2050, with cumulative savings of 1.2–2.8 billion GJ. Associated cumulative GHG emission reductions were estimated at 92.1–215.0 million metric tons. In addition, thousands of tons of aluminum, titanium and nickel alloys could be potentially saved per year in 2050. The results indicate a significant role of AM technologies in helping society meet its long-term energy use and GHG emissions reduction goals, and highlight barriers and opportunities for AM adoption for the aircraft industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Green Routing Fuel Saving Opportunity Assessment: A Case Study on California Large-Scale Real-World Travel Data

New technologies, such as connected and automated vehicles, have attracted more and more researchers for improving the energy efficiency and environmental impact of current transportation systems. The green routing strategy instructs a vehicle to select the most fuel-efficient route before the vehicle departs. It benefits the current transportation system with fuel saving opportunity through identifying the greenest route. This paper introduces an evaluation framework for estimating benefits of green routing based on large-scale, real-world travel data. The framework has the capability to quantify fuel savings by estimating the fuel consumption of actual routes and comparing to routes procured by navigation systems. A route-based fuel consumption estimation model, considering road traffic conditions, functional class, and road grade is proposed and used in the framework. An experiment using a large-scale data set from the California Household Travel Survey global positioning system trajectory data base indicates that 31% of actual routes have fuel savings potential with a cumulative estimated fuel savings of 12%.

33 ADVANCED PROPULSION SYSTEMS↗

Potential for the Use of Energy Savings Performance Contracts to Reduce Energy Consumption and Provide Energy and Cost Savings in Non-Building Applications

The findings of this study indicate that potential exists in non-building applications to save energy and costs. This potential could save billions of federal dollars, reduce reliance on fossil fuels, increase energy independence and security, and reduce greenhouse gas emissions. The Federal Government has nearly twenty years of experience with achieving similar energy cost reductions, and letting the energy costs savings pay for themselves, by applying energy savings performance contracts (ESPC) in its buildings. Currently, the application of ESPCs is limited by statute to federal buildings. This study indicates that ESPCs can be a compatible and effective contracting tool for achieving savings in non-building applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chapter 21: Estimating Net Savings - Common Practices. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

This chapter focuses on the methods used to estimate net energy savings in evaluation, measurement, and verification (EM and V) studies for energy efficiency (EE) programs. The chapter provides a definition of net savings, which remains an unsettled topic both within the EE evaluation community and across the broader public policy evaluation community, particularly in the context of attribution of savings to a program. The chapter differs from the measure-specific Uniform Methods Project (UMP) chapters in both its approach and work product. Unlike other UMP resources that provide recommended protocols for determining gross energy savings, this chapter describes and compares the current industry practices for determining net energy savings but does not prescribe methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Timed to save: the added value of accounting for hourly incidence of electricity savings from residential space-conditioning measures

Abstract Previous research has recognized that the value of measures that reduce electricity usage depends upon the timing of the savings generated, but the lack of hourly savings shapes has limited the demonstration of this concept. We develop empirical hourly savings shapes for residential space-conditioning measures from nearly 18,000 efficiency projects in California and show how they combine with the diurnal and seasonal variation in electricity system costs. We find that these measures (cooling replacements; windows, doors, and skylights; and other envelope measures) tend to save electricity when system costs are highest and that the hourly savings account for 1.4–1.5 times as much value as non-time-sensitive estimates of efficiency would predict. We present these impact multipliers for each measure to quantify the additional value revealed by the time-sensitive approach. We show that this additional value is similar in an evolving electricity grid with storage, rather than natural gas generation, as the marginal resource.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Savings From System Efficiency Improvements in Iowa's HVAC SAVE Program

The objective of this project is to explore the energy savings potential of maximizing furnace and distribution system performance by adjusting operating, installation, and distribution conditions. The goal of the Iowa HVAC System Adjusted and Verified Efficiency (SAVE) program is to train contractors to measure installed system efficiency as a diagnostic tool to ensure that the homeowner achieves the energy reduction target for the home rather than simply performing a tune-up on the furnace or having a replacement furnace added to a leaky system. The PARR research team first examined baseline energy usage from a sample of 48 existing homes, before any repairs or adjustments were made, to calculate an average energy savings potential and to determine which system deficiencies were prevalent. The results of the baseline study of these homes found that, on average, about 10% of the space heating energy available from the furnace was not reaching the conditioned space. In the second part of the project, the team examined a sample of 10 homes that had completed the initial evaluation for more in-depth study. For these homes, the diagnostic data shows that it is possible to deliver up to 23% more energy from the furnace to the conditioned space by doing system tune ups with or without upgrading the furnace. Replacing the furnace provides additional energy reduction. The results support the author's belief that residential heating and cooling equipment should be tested and improved as a system rather than a collection of individual components.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chapter 10: Peak Demand and Time-Differentiated Energy Savings Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

Savings from electric energy efficiency measures and programs are often expressed in terms of annual energy and presented as kilowatt-hours per year (kWh/year). However, for a full assessment of the value of these savings, it is usually necessary to consider the measure or program's impact on peak demand as well as time-differentiated energy savings. This cross-cutting protocol describes methods for estimating the peak demand and time-differentiated energy impacts of measures implemented through energy efficiency programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗

Optimal Sizing of a Solar-Plus-Storage System for Utility Bill Savings and Resiliency Benefits

Solar-plus-storage systems can achieve significant utility savings in behind-the-meter deployments in buildings, campuses, or industrial sites. Common applications include demand charge reduction, energy arbitrage, time-shifting of excess photovoltaic (PV) production, and selling ancillary services to the utility grid. These systems can also offer some energy resiliency during grid outages. It is often difficult to quantify the amount of resiliency that these systems can provide, however, and this benefit is often undervalued or omitted during the design process. We propose a method for estimating the resiliency that a solar-plus-storage system can provide at a given location. We then present an optimization model that can optimally size the system components to minimize the lifecycle cost of electricity to the site, including the costs incurred during grid outages. The results show that including the value of resiliency during the feasibility stage can result in larger systems and increased resiliency.

14 SOLAR ENERGY↗

Chapter 12: Survey Design and Implementation for Estimating Gross Savings Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

This chapter presents an overview of best practices for designing and executing survey research to estimate gross energy savings in energy efficiency evaluations. A detailed description of the specific techniques and strategies for designing questions, implementing a survey, and analyzing and reporting the survey procedures and results is beyond the scope of this chapter. So for each topic covered below, readers are encouraged to consult articles and books cited in References, as well as other sources that cover the specific topics in greater depth. This chapter focuses on the use of survey methods to collect data for estimating gross savings from energy efficiency programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Building America Solution Center Shows Builders How to Save Materials Costs While Saving Energy

This short article was prepared for the U.S. Department of Energy's Building America Update newsletter. The article identifies energy and cost-saving benefits of using advanced framing techniques in new construction identified by research teams working with the DOE's Building America program. The article also provides links to guides in the Building America Solution Center that give how-to instructions for builders who want to implement advanced framing construction. The newsletter is issued monthly and can be accessed at http://energy.gov/eere/buildings/building-america-update-newsletter

advanced framing↗