Search NASASearch

SEARCH · Search NASA

Results for “SAVY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Technical Basis SAVY-4000® Series, 5.5G Container (Rev. 1)

The 5.5 Gallon (5.5G) SAVY-4000® nuclear material storage container is the latest in the SAVY-4000® series. The 5.5G is similar to that of a 1or 2Qt container in functionality with the exception of a larger volume deep drawn and spun form body achieved through increases in the depth and diameter of the container. Here, a technical basis using engineering equivalency analysis, calculation, and test data is presented to establish that the 5.5G SAVY-4000® Container is a DOE Manual 441.1-1 compliant container at a drop height of 9 feet (rather than the typical 12 ft of the other SAVY-4000® containers) and that a twenty-five year design life (as with the currently approved SAVY-4000® series) is justified.

99 GENERAL AND MISCELLANEOUS

Measuring 3D Profilometry of SAVY-4000 Nuclear Material Storage Containers: Novacam TubeInspect Capabilities Report

The SAVY-4000 container series is a general-purpose interim storage container for nuclear materials, developed and maintained by Los Alamos National Laboratory (LANL). It is the first vented, general-use nuclear material container to be demonstrated as meeting the requirements outlined in DOE M 441.1-1, the Nuclear Material Packaging Manual. Due to the challenging radiation, thermal, and corrosive storage conditions that the SAVY containers must endure, continuous surveillance techniques are employed to ensure the containers meet all safety standards and specifications. These inspections are typically performed by human operators, who check for issues such as corrosion, O-ring deterioration, corrosion, filter integrity, and potential manufacturing defects. However, human inspections alone are not sufficient, and automated inspection technologies, such as the ATIS system, as well as other automated systems are also utilized. The MicroCam TubeInspect, developed by Novacam Technologies Inc., is designed to address the challenges of understanding how manufacturing variations in the SAVY-4000 container series may affect performance. It is a 3D profilometry measurement system that enables detailed analysis of surface features, including defects, surface roughness, and manufacturing variations. This advanced tool significantly enhances rapid surveillance techniques for both pristine and used containers. In this study, container properties such as surface roughness, thickness, and geometric attributes like circularity are measured for SAVY-4000 containers. Artificially corroded or dented containers are examined to demonstrate the MicroCam's ability to quantify defects. A sensitivity analysis is also conducted, comparing the MicroCam results to those obtained using more precise instruments such as confocal microscopy. This comparison aims to provide valuable insights into container quality, durability, and potential improvements in manufacturing processes.

42 ENGINEERING

Overview of SAVY-4000 Lifetime Extension Activities in Fiscal Year 2024

This report provides an overview of activities engaged in during the 2024 fiscal year in support of the SAVY-4000 (hereafter “SAVY”) lifetime extension. As the final full year prior to the submittal of the technical basis, efforts were made to assess the current understanding regarding SAVY degradation in service as well as any knowledge that provided a more substantive view of the challenges that SAVYs face in storage. Close coordination with the stakeholders (i.e. LANL program office) ensured alignment with expectations regarding timelines for the remainder of the activities supporting the technical basis document for the lifetime extension request.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Full Submersion Water Testing of SAVY-4000 Nuclear Material Storage Containers

SAVY-4000 (SAVY) containers are the primary container used at Technical Area (TA) TA-55 plutonium facility for the prevention of water ingress to mitigate against a criticality event. The basis for water resistance of these containers has long been attributed to the Polytetrafluoroethylene (PTFE) membrane that is assembled on the outermost surface of the filter assembly. On August 22nd a test of a container used inside of a glovebox was performed that brought into question this long-standing-basis. This test was performed by inverting a SAVY-lid onto a specialized piece of equipment for evaluating the integrity of the PTFE membrane. During the test water was observed passing through the filter indicating that the filter membrane was no longer preventing the ingress of water through the filter. The assumption after making this observation was that alpha-particles were rapidly degrading the membrane creating a leak path through the underlying aluminosilicate media (Fiberfrax®). The apparatus used was designed to only test the lid rather than the entire SAVY assembly. A test plan, PA-PLAN-01921, was developed to investigate whether a fully assembled container with a fully degraded PTFE membrane would be capable of meeting the criteria defined in PA-RD-1009 of not allowing more than 200 ml of water to enter the container with a water column of 6-inches applied over a 2-hour period. This report provides the results of the testing performed against PA-PLAN-01921.

36 MATERIALS SCIENCE

Technical Basis Update for the Design Life Extension of the SAVY-4000® Series of Containers

This technical basis update focuses on the design life of the SAVY-4000® (hereafter “SAVY”) series of nuclear material storage container (e.g., used to store, transport, and handle special nuclear material outside of a glovebox), previously approved under DOE Manual 441.1-1, Nuclear Material Packaging Manual. The SAVY is approved for storing all authorized contents for a period of 15 years. The lifetime extension technical basis is established on the compiled technical data from the on-going SAVY and Hagan surveillance programs, destructive analysis results, accelerated aging studies, and performance testing, in line with the regulatory rigor of DOE M441.1-1.

42 ENGINEERING

Normalization of multidirectional red and NIR reflectances with the SAVI

Directional reflectance measurements were made over a semi-desert gramma grassland at various times of the growing season. View angle measurements from +40 to -40 degrees were made at various solar zenith angles and soil moisture conditions. The sensitivity of the Normalized Difference Vegetation Index (NDVI) and the Soil Adjusted Vegetation Index (SAVI) to bidirectional measurements was assessed for purposes of improving remote temporal monitoring of vegetation dynamics. The SAVI view angle response was found to be symmetric about nadir while the NDVI response was strongly anisotropic. This enabled the view angle behavior of the SAVI to be normalized with a cosine function. In contrast to the NDVI, the SAVI was able to minimize soil moisture and shadow influences for all measurement conditions.

Huete, A. R.

SAVY O-ring characterization for lifetime extension

Los Alamos National Laboratory and Nuclear Filter Technology, Inc. developed the SAVY-4000 nuclear material storage container, named after the designers Stone, Anderson, Viers, and Yarbro. The SAVY 4000 meets the requirements of Department of Energy (DOE) M 441.1-1,2 Nuclear Material Packaging Manual, to protect workers who handle nuclear materials against radiation exposures resulting from the leakage of stored materials. The SAVY-4000 is an innovative and creative design: it can be opened and closed in a few seconds without using torque wrenches and instead only a tire iron or equivalent prying tool; has a built-in, fire-rated filter that prevents the build-up of hydrogen gas yet retains 99.97% of plutonium particulates at 200 ACCM rated flow; and prevents the release of stored materials upon a 12- foot drop.

42 ENGINEERING

An initial effort to study the influence of pitting in SAVY containers

As part of a broader effort to investigate a critical pit depth, below which SAVY containers fail a leak test after a drop test, surrogate testing using pristine SAVY container material was investigated. The original study involved producing pits in a SAVY wall to depths 35% to 55% of the wall thickness and subjecting the pitted container to a drop test under prototypic conditions. Subsequent leak testing after drop testing showed the container passed and that the pit size distribution and drop conditions were not sufficient to cause a leak test failure in this specific container.

36 MATERIALS SCIENCE

Mechanisms of the Space Active Vibration Isolation (SAVI)

The Space Active Vibration Isolation (SAVI) is a concept for vibration isolation of one body from another with simultaneous precise control in 6 Degrees Of Freedom (DOF). SAVI achieves this using a combination of electromechanical linear actuators and magnetic actuators. Other mechanisms of interest include a structure for simulating the body being pointed, an apparatus to simulate the body that is the vibration source, and mechanisms to off-load the weight of each of these two bodies from the experiment to approximate a zero-g condition. A SAVI was built and tested to demonstrate these capabilities.

Schmitt, Frank

Framework development for a SAVY-4000 nuclear material storage container structural integrity surveillance tool

Here, this work presents the preliminary design of an automated surveillance tool to assess the health of SAVY-4000 nuclear material storage containers. This tool is designed by training several machine learning (ML) regression models to predict maximum residual stress in plain dents on the container sidewall. The model is trained on an experimentally validated Finite Element Analysis (FEA) model built in Abaqus FEA. The accuracy of each ML model is compared. The potential for application as well as model shortcomings are assessed. Necessary FEA model improvements are outlined and the various ML models are proposed.

36 MATERIALS SCIENCE

SAVY-4000 Finite-Element Drop Test Analysis

PFE Auxiliary Systems conducted drop testing on SAVY-4000 containers to evaluate structural response under 12-foot drop conditions. In support of that effort, a finite-element modeling capability was developed to simulate drop response across multiple container sizes and impact orientations. The purpose of this work was to provide a consistent analysis framework that could support interpretation of testing, compare response trends across multiple configurations, and generate quantities of interest for later comparison with experimental data. More broadly, the analysis and testing were intended to assess whether the containers continued to perform their primary function after a 12-foot drop, namely maintaining structural integrity and containment of the contents. The modeling approach combined an implicit preload analysis with an explicit drop simulation so that each drop event began from a mechanically realistic assembled condition, including compression of the silicone O-ring. Separate models were developed for 2-quart, 5-quart, 12-quart, and 10-gallon containers. The results were evaluated in terms of strain-gauge response, collar-lid gap behavior, and accumulated plastic strain. In addition, parametric studies were performed on the 2-quart container to assess sensitivity to O-ring stiffness, friction, canister thickness, geometry tolerance, and mesh density. The simulations showed that predicted drop responses depended strongly on both container size and drop orientation. Gap metrics identified cases in which the predicted collar-lid opening exceeded the nominal O-ring cross-section threshold, while plastic strain metrics identified localized regions of elevated permanent deformation. Parametric studies showed that the predicted response was especially sensitive to the assumed O-ring stiffness and contact friction, while the geometry tolerance study produced smaller changes in the cases examined. The main value of this work was that it established a repeatable modeling and simulation workflow to support drop-test implementation, evaluate effects of future configuration changes, and understand modeling assumptions that most influenced predicted response. At the current stage, the results were viewed as preliminary model predictions rather than validated predictions. The next step would be to compare drop-test data to the model so that predictive values of the workflow could be refined and used with greater confidence to assess whether the containers maintained structural integrity and containment of the contents after a 12-foot drop.

42 ENGINEERING

Eigenvalue/Eigenvector derivatives for SAVI Gimbalflex nonlinear transient response analysis

An eigenvector expansion method is utilized to predict eigenvalue and eigenvector derivatives due to geometric reconfiguration of a Gimbalflex fine-pointing/vibration isolation system called SAVI (Space Active Vibration Isolation). The eigenvector expansion method used is a modification of the classical method and allows for rigid body roots. Using the resulting modal derivatives, free-free nonlinear equations of motion are developed with Lagrange's Method. These equations represent a nonlinear plant model to be used in conjunction with a control system transient response simulation.

Orr, M. F., Jr.

Laser Confocal Microscopy Uncertainty Quantification Study

At Los Alamos National Laboratory (LANL), the Storage Safety and Engineering (SSE) team completes annual surveillance on a subset of in-use interim nuclear material storage containers in fulfilment of requirements outlined in DOE Manual M 441.1-1. The containers are selected through several methods, such as subject matter expert judgement, random selection, and trending items. Following these selections, the SSE team has the capacity to complete surveillance on 15-20 containers each fiscal year, composed of a combination of SAVY-4000 and Hagan storage containers. Through previous work, the stainless-steel components of the containers have been identified as life limiting components, with an emphasis on the thin-walled bodies. The team is focused on understanding the extent of general and pitting corrosion, due to observations of extensive corrosion from stored contents and bag-out-bag degradation. Quantifying corrosion effects on the thin-walled stainless steel container bodies, and understanding potential impacts to the respective design release rates and design qualification release rates is paramount to the team. To date, destructive examination (DE) has proven to be the most insightful method for developing an understanding on the extent of corrosion on used containers. To standardize this process, the SSE team developed a destructive examination guide for analyzing stainless steel components of the containers. Corroded containers of interest are identified during surveillance activities and set aside for sectioning and characterization. Following sectioning, a major step in the DE workflow is the utilization of laser confocal microscopy for scanning corroded samples of interest and extracting data on pits, such as count, depth, and equivalent diameter. Adhering to the techniques outlined in the DE guide, analysis has been completed on two Hagans and one SAVY-4000 container, with the maximum pit depth recorded as 139.1 ± 22.82 μm on a 17.5 year old Hagan. The findings from the completed destructive examinations will be utilized to support lifetime extension efforts of the SAVY-4000 as the team can better estimate corrosion rates and effects over time based on stored contents and age. Due to the implications of observing extreme pit depths that approach the nominal container body thickness of .0299 inches (0.759 mm) or minimum container thickness of 0.236” (0.6 mm), high confidence in the LCM measurements is desired. Through testing outlined in, it was concluded that the total error ascribed to the 20x objective when conducting large image mapping on the Keyence VK-X3050 laser confocal microscope (LCM) relative to a 50x objective (reference) is 16.4% (± 8.73%). For shallow features on the order of pristine SAVY surface defects (i.e. 5 μm), this uncertainty is appropriate. However, this conservative estimate of total error poses a fundamental concern for pit depths that approach the thickness of the measured samples. That is, with the measurement uncertainty currently employed on all measurements, the LCM would be unable to resolve if a pit with a depth of 515 μm is through wall. Standard step height samples were procured and used in the present study to assess the resolution and repeatability of height measurements. Understanding the resolution and repeatability of height measurements was the first focus of the team as it relates directly to pit depth, which is of primary concern. Calibration gratings were procured to evaluate the resolution and repeatability of measurements in the X and Y axes of the LCM stage. The results of the depth uncertainty study were conducted first and presented in the subsequent sections. The planar uncertainty study is appended to the depth study with conclusions from both summarized at the end of the report.

36 MATERIALS SCIENCE

Reducing the Risk of Airborne Contamination through Intelligent Container Surveillance

DOE Manual 441.1-1 provides a set of performance criteria that nuclear material storage containers must achieve to provide protection to the worker, public, and environment. At Los Alamos National Laboratory, the SAVY-4000 is the container of choice for nuclear material storage, meeting all Manual requirements. At the outset, polymer components of the SAVY 4000 were considered to be life-limiting components due to their performance degradation resulting from radiation exposure. However, recent annual surveillance results revealed another life-limiting phenomenon for the container: a deterioration of the package integrity through corrosion of the stainless steel components, primarily the body. Container surveillance remains the choice method of observing, measuring, and tracking container health in service.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Assessing the Relationship Between Spectral Vegetation Indices and Shrub Cover in the Jornada Basin, New Mexico

We assessed the statistical relations between Spectral Vegetation Indices (SVI's) derived from SPOT multi-spectral data and semi-arid shrub cover at the Jornada LTER site in New Mexico. Despite a limited range of shrub cover in the sample the analyses resulted in r(sup 2) values as high as 0 central dot 77. Greenness SVI's (e.g., Simple Ratio, NDVI, SAVI, PVI and an orthogonal Greenness index) were shown to be more sensitive to shrub type and phenology than brightness SVis (e.g., green, red and near-infrared reflectances and a Brightness index). The results varied substantially with small-scale changes in plot size (60m by 60m to 100m by 100m) as a consequence of landscape heterogeneity. The results also indicated the potential for the spectral differentiation of shrub types, and shrubs from grass, using multi-temporal, multi-spectral analysis.

Duncan, Jeff

The Reaction of Atomic Hydrogen with an Imine: Direct Kinetic Measurements and Computational Studies

Imines are of interest in the combustion modeling of nitrogen-based fuels such as ammonia, as intermediates in atmospheric oxidation of amines, and may offer a new class of environmentally benign substitutes for perhalogenated reagents. Elementary gas-phase rate constants for the consumption of H atoms by 1,1,1,3,3,3-hexafluoro-2-propanimine were measured over 294–736 K using the laser flash photolysis/atomic resonance fluorescence technique. The results are summarized as 3.0 × 10 –11 exp(−14.5 kJ mol –1 /RT) cm 3 molecule –1 s –1 with a confidence interval of ±13%. These are the first temperature-dependent kinetic experiments on an imine of the form R 2 C═NH and thereby provide the only validation of transition-state modeling for such systems. Several pathways are feasible; comparison of theory and experiment suggests the dominant channel is addition of H atoms to the nitrogen atom. On this basis, the observations are rationalized quantitatively. Computations also yield the thermochemistry of (CF 3 ) 2 CNH, with Δ f H 298 = −1232 kJ mol –1 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH