Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCINTILLATION COUNTERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Exploring solar neutrino oscillation parameters with the liquid scintillator counter at Yemilab with a comparison to JUNO

We investigate the sensitivities of the liquid scintillator counter (LSC) at Yemilab and JUNO to solar neutrino oscillation parameters, focusing on θ 12 and Δ m 21 2 . We compare the potential of JUNO with LSC at Yemilab utilizing both reactor and solar data in determining those parameters. We find that the solar neutrino data of LSC at Yemilab is highly sensitive to θ 12 enabling its determination with a higher precision compared to reactor experiments. Our study also reveals that if Δ m 21 2 is larger, with a value close to the best-fit value of KamLAND, JUNO reactor data will have about two times better precision than the reactor LSC at Yemilab. On the other hand, if Δ m 21 2 is smaller and closer to the best-fit value of solar neutrino experiments, the precision of the reactor LSC at Yemilab will be better than JUNO. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance studies of the Mu2e cosmic ray veto detector

The cosmic ray veto (CRV) detector of the Mu2e experiment consists of four layers of plastic scintillation counters that surround the detector solenoid. These counters are embedded with wavelength-shifting fibers and are read out by silicon photomultipliers (SiPMs). The performance of a subset of the CRV counters was studied in a cosmic-ray test stand. Here, using data taken over a two-year period, we report the single-layer muon detection efficiency and the rate at which the light yield degrades due to the aging of the plastic scintillation counters.

Aging↗

Adiabatic light guide with S-shaped strips

A light guide is an essential part of many scintillator counters and light collection systems. Our main interest is a light guide for a thin, wide scintillator that has high light transmission while converting the area of the light source to the shape of a photo-detector. Here, we propose a variation of the light guide that avoids a 90° twist of the strips, reduces the length of the light pipe, and reduces the complexity of production. Detailed Monte Carlo simulation studies have been performed for a three-strip S-shaped light-guide system.

47 OTHER INSTRUMENTATION↗

The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3

The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of ℒ = 2 × 10 34 cm -2 s -1 was routinely achieved at the start of fills, twice the design luminosity. For Run 3, accelerator improvements, notably luminosity levelling, allow sustained running at an instantaneous luminosity of ℒ = 2 × 10 34 cm -2 s -1 , with an average of up to 60 interactions per bunch crossing. The ATLAS detector has been upgraded to recover Run 1 single-lepton trigger thresholds while operating comfortably under Run 3 sustained pileup conditions. A fourth pixel layer 3.3 cm from the beam axis was added before Run 2 to improve vertex reconstruction and b-tagging performance. New Liquid Argon Calorimeter digital trigger electronics, with corresponding upgrades to the Trigger and Data Acquisition system, take advantage of a factor of 10 finer granularity to improve triggering on electrons, photons, taus, and hadronic signatures through increased pileup rejection. The inner muon endcap wheels were replaced by New Small Wheels with Micromegas and small-strip Thin Gap Chamber detectors, providing both precision tracking and Level-1 Muon trigger functionality. Trigger coverage of the inner barrel muon layer near one endcap region was augmented with modules integrating new thin-gap resistive plate chambers and smaller-diameter drift-tube chambers. Tile Calorimeter scintillation counters were added to improve electron energy resolution and background rejection. Upgrades to Minimum Bias Trigger Scintillators and Forward Detectors improve luminosity monitoring and enable total proton-proton cross section, diffractive physics, and heavy ion measurements. These upgrades are all compatible with operation in the much harsher environment anticipated after the High-Luminosity upgrade of the LHC and are the first steps towards preparing ATLAS for the High-Luminosity upgrade of the LHC. This paper describes the Run 3 configuration of the ATLAS detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A 90 ° bend curved light-guide for TOF scintillating detectors

We report here a bench study of TOF resolution using a 90° bend curved solid light-guide (LG) used to transport the light from a plastic scintillator counter to a photomultiplier (PMT). The 90° LG allows the rotation of the PMT axis to be vertical to the detector axis, in an environment featured by a strong magnetic field along the detector surface, or other geometrical constrains. We show that with a TOF counter of 2000 x 100 x 60 mm 3 and light read-out by PMTs at its two 100 × 60 mm 2 sides, when 90° LG benders are used between the scintillating bar and the PMTs on both sides, the TOF resolution is worsen, by 5–10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 Central Time-of-Flight system

The Central Time-of-Flight system for the large-acceptance CLAS12 spectrometer in Hall B at the Thomas Jefferson National Accelerator Facility is described. The system consists of a hermetic barrel of 48 scintillation counters at a radius of 25 cm from the beamline. The wedge-shaped counters are 3.4 cm wide, 3.0 cm thick, and 90 cm long, and span a range of polar angles relative to the center of the nominal target location from roughly 35° to 125°. The counters reside in the 5-T field of the CLAS12 superconducting solenoid. The bars are read out via bent light guides 1 m long on the upstream end of the counters and 1.6 m long on the downstream end. The phototubes are shielded by a multi-layer dynamical magnetic shield system to reduce the local fringe fields in the range from 400 G to 1000 G down to the level of 0.2 G at the location of the photocathodes. The average effective time resolution of the counters is 80 ps.

47 OTHER INSTRUMENTATION↗

Impact of lowering potassium contamination in liquid scintillation cocktails for ultra-sensitive radiation detection

Intrinsic 40 K radioactive backgrounds from impurities of natural K in liquid scintillation cocktails have previously been demonstrated to limit their use in ultra-sensitive applications. Here, this work explores two methodologies in parallel for the reduction of 40 K backgrounds in the cocktails, and lays the groundwork for use in ultra-sensitive applications. In one method, alternative low-K liquid scintillation matrix constituents were identified and in the other, a simple purification method for single components and finished cocktails was developed. Both methods were verified via ICP-MS analysis. Liquid scintillation counting of selected purified cocktails demonstrated background reduction, improved stability, and enhanced performance. The best performing purified cocktail was also counted on a custom-built ultra-low background liquid scintillation counter, with results below the detector background.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The CLAS12 Forward Time-of-Flight system

The Forward Time-of-Flight system for the large-acceptance CLAS12 spectrometer in Hall B at the Thomas Jefferson National Accelerator Facility is described. The system is positioned at distances in the range from 6.2 m to 7.2 m from the beam–target interaction point and spans laboratory polar angles from 5 deg → 45 deg and nearly the full azimuth. The system consists of 540 individual scintillation counters with double-ended readout that range in length from 17 cm to 426 cm of discrete widths of 6 cm, 15 cm, and 22 cm, and of discrete thicknesses of 5 cm and 6 cm. We see the effective counter time resolution for passing charged particles varies from 50 ps for the shortest counters at small angles to 200 ps for the longest counters at large angles. The detectors are part of the forward-angle particle identification system for CLAS12 during offline event reconstruction and are a component of the online data acquisition trigger to select final state event topologies with forward-going charged particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of background limitations to ultra-sensitive $\mathrm{LSC}$ counting through $\mathrm{ICP}$-$\mathrm{MS}$ assay of $\mathrm{LSC}$ cocktails

We report the performance of LSC cocktails in ultra-sensitive applications was evaluated. Backgrounds from radioactive contaminations in commercially available and in-house developed liquid scintillation cocktails were measured and compared to the predicted background levels of the ultra-low background liquid scintillation counter. Through the ICP-MS assay of the cocktails and their constituents, potassium impurities in the surfactant component were identified as a significant source of background, potentially limiting the use of LSC counting in ultra-sensitive applications. This work lays the groundwork for future research towards ultrapure LSC cocktails for ultrasensitive LSC counting

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of the wavelength-shifting fiber upgrade for the Mu2e cosmic-ray veto detector

The Cosmic-Ray Veto detector for the muon-to-electron conversion experiment at Fermilab consists of four plastic scintillating counter layers read out by silicon photo-multipliers through embedded wavelength-shifting fibers. In order to increase the light yield in the most critical regions of the Cosmic-Ray Veto detector for improved background rejection, a 1.8 mm diameter fiber is being used in many of the detector's critical modules instead of the previously planned 1.4 mm diameter fiber. This paper reports the testing procedure and light properties of thirty-four 1.8 mm fiber spools, with measurements performed using a custom-built scanner. We compare these new results with previously published data from the 1.4 mm diameter fiber used for regions of the cosmic-ray veto where the increased light yield is not required. In addition, measurements of fiber aging were performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alpha/beta-gated gamma–gamma spectroscopy of mixed fission products for trace analysis

This experiment demonstrated that some hard-to-detect fission products can be quantified directly from mixed fission product samples using advanced radio-emission spectroscopy techniques. A gamma/gamma coincidence detector was combined with a custom liquid scintillation counter to evaluate the benefits of alpha and beta coincident and anti-coincident analysis of mixed fission product samples. Reduction factors in the minimum detectable activity (MDA) relative to traditional gamma counting were quantified for a set of radionuclides. For isotopes like 91Y, 144Ce, 147Nd, and 153Sm MDA reductions of factors of 1-2 were observed using optimized beta thresholds. Using beta anti-coincidence counting reductions of factors 3-5 were observed for isotopes like 89Sr, 95mNb, 115Cd, and 137Cs and factors of 5-7 for isotopes like 235U using alpha coincidence counting. The selectivity of gamma/gamma coincidence and reduction in backgrounds using beta gating were also demonstrated with 136Cs and 153Sm. The improvements observed in the detection sensitivity of fission products and actinides achieved by combining time-correlated radiation signatures is significant and of value to applications such as nuclear fission physics, environmental monitoring for nuclear waste, reactor accidental releases, and nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Temporal Characterization of Tritium Smear Activities

Tritium collection efficiency varies as a function of smear media. The use of porous smear materials leads to an increase in the measured tritium activity as a function of time when the measurement is performed with liquid scintillation counters. Operational inclusion of the efficiency differences and the time dependence of the tritium smear activity is necessary to preclude inadvertently releasing materials or areas. Thomas Jefferson National Laboratory Radiological Control Department identified a contaminated stainless steel containment vessel that previously housed a target containing more than 37 TBq of tritium. The item was systematically sectioned and surveyed to compare three smear types: water-wetted cotton swabs, water-wetted paper smears, and ethanol-wetted Styrofoam wipes (NUC-Wipes™). The total activity of each section was determined using repeated decontamination. The time dependence of the measured activity was also studied. The measured activity of both paper smears and cotton swabs showed significant time dependence. The cotton swabs also showed significantly reduced collection efficiency. Given the widespread use of both of these media in routine contamination surveys, site operational limits were derived using fitted curves for time dependence and average efficiency results. In conclusion, the use of these more restrictive limits allows for rapid measurement of tritium smears while ensuring regulatory compliance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mu2e - Extinction Monitor Research & Development

Current efforts are being conducted at Fermi National Laboratory to study potential violations in accepted theory that would otherwise suggest a restructuring of our fundamental understanding of the universe. Mu2e is one of these frontier projects that studies charged lepton flavor violation (CLFV) which if observed, would suggest physics beyond the Standard Model. Therefore, this note encompasses several projects that contribute to the fruition of Mu2e investigations. Due to the broad range of disciplinary inconsistencies that each project requires, all the work is being presented as a means of justifying contribution to Mu2e. The projects are comprised of a G4Beamline simulation analyzing 8GeV proton beam interaction with a titanium window of Recycler ring extinction rates using three Cherenkov radiation-based detectors and supplemental work for the implementation of a micro–Telecommunications Computing Architecture (MicroTCA) crate to establish a peak finding algorithm to ensure that the out-of-time beam is less than 10^-10 fractional level along with inefficiency analysis on scintillation counters for the Cosmic-Ray Veto (CRV) analysis. Preliminary results have been achieved for extinction rate simulation by achieving coincidence rates for 2/3-fold and 3/3-fold on the detectors in the order of 10^-9 and 10^-10, respectively. Only preliminary results of a triangular counter and four rectangular di-counters for the CRV have been realized but other non-experimental contributions were made to the development of the MicroTCA crate.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Standard Analytical Methods for Pyrolysis Bio-Oils

There has been significant recent interest in the production of renewable fuels and chemicals from biomass and waste feedstocks. Pyrolysis pathways produce a liquid bio-oil product, which must be processed further, or upgraded, to yield fuel or chemical products. Bio-oils are very complex and often unstable samples, and research and development on upgrading processes needs reliable analytical information. In particular, chemical characterization techniques are needed to quantify both functional groups and individual compounds present in bio-oils. Reliable analytics are also needed to enable the bioenergy industry, as industrial facilities often have different analytical needs and capabilities than research facilities. In this presentation, we will discuss the development of a suite of standard analytical methods for pyrolysis bio-oils. Analytical methods to be discussed include: Determination of Carbon, Hydrogen, Nitrogen, and Oxygen in bio-oils; Accelerated Aging of Fast Pyrolysis Bio-oil using Carbonyl Titration; Determination of Water Content in Bio-oils by Volumetric Karl Fischer Titration; Determination of Carbon Functional Groups; Elemental Analysis of Bio-oils by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) - Na, K, Mg, Ca, S, P, and Fe; Determination of Phenolic Groups in Bio-oils using Revised Folin-Ciocalteu Methods: Single Cuvette and Plate Reader; Corrosivity of Bio-oils: Screening Test using Metal Leaching; Determination of Biogenic Content by 14C Measurement using Liquid Scintillation Counter. These new analytical methods are publicly available as Laboratory Analytical Procedures (https://www.nrel.gov/bioenergy/bio-oil-analysis.html), along with previously developed standard methods: GC-MS, Acid Titration, Carbonyl Titration, and 31P NMR. Additionally, the development of diffusion ordered NMR for characterization of bio-oil molecular weight will be discussed. Collectively, this suite of analytical methods represents the most comprehensive set of standard methods available for pyrolysis bio-oils. These standard methods are commonly used by the bioenergy community, and provide reliable information that enables research, scaleup, and industrial processing of biomass to produce renewable fuels and chemicals.

analytical↗

Mu2e - Research & Development

Current efforts are being conducted at Fermi National Laboratory to study potential violations in accepted theory that would otherwise suggest a restructuring of our fundamental understanding of the universe. Mu2e is one of these frontier projects that studies Charged Lepton Flavor Violation (CLFV) which if observed, would suggest physics beyond the Standard Model. Therefore, this note encompasses several projects that contribute to the fruition of Mu2e investigations. Due to the broad range of disciplinary inconsistencies that each project requires, all the work is being presented as a means of justifying contribution to Mu2e. The projects are comprised of a simulation exploring the extinction level of proton pulses after Recycler ring re-bunching by using G4beamline to simulate an 8GeV proton beam interaction with a titanium target, three Cherenkov radiation-based detectors and 2/3-fold and 3/3-fold coincidence rate analysis. Additionally, supplemental work for the implementation of a Micro Telecommunications Computing Architecture (TCA) crate to establish a peak finding algorithm to ensure that the out-of-time beam is less than 10$^{−10}$ fractional level along with single-layer inefficiency analysis on scintillation counters for the Cosmic-Ray Veto (CRV) analysis to ensure the overall inefficiency is 10$^{−4}$. Preliminary results have been achieved for the G4beamline simulation 2/3-fold and 3/3-fold coincidences which are in the order of 10$^{−9}$ and 10$^{−10}$, respectively. Only preliminary results of a triangular counter and four rectangular di-counters for the CRV have been realized. The microTCA crate development is still ongoing.

43 PARTICLE ACCELERATORS↗

Demonstration of low-level biogenic fuel content using quench curve and direct liquid scintillation counting (LSC) methods

In this work, an investigation into the direct method for liquid scintillation counting (LSC) quantification of biogenic fuel content in fuel blendstock is presented. This method development intentionally used a colored matrix (~99 wt%), fossil diesel fraction, and low-level biogenic fractions (~1 wt%) to determine the applicability of the LSC technique in colored blend mixtures. LSC procedures for quench correction, including the use of an instrument internal standard (Quantulus SQP values), color quench curves, and an internal 14 C standard spike on samples containing low-level amounts of biogenic gasoline, jet, and diesel mixed with fossil fuel, were compared. Samples were analyzed on both Perkin-Elmer Quantulus and Tri-Carb instruments, and the 14 C contents were compared with those determined by accelerator mass spectrometry (AMS). Results from the Tri-Carb instrument showed that percent differences of <10 % compared to AMS-reported values are achievable at 5-hour count times despite colored samples. A comparison between the impact of chemical and color quenching in the fuel samples showed that color quenching in highly colored samples reduces efficiency significantly more than chemical quenching, indicating that chemical quench curves are not appropriate for highly colored biofuel/fossil-fuel blended samples. Results indicate that both the direct method with internal spike quench correction and the use of a color-quench curve provide accurate results for 1 % biogenic fuel blends. Additionally, we have explored the use of Fourier transform infrared (FTIR) spectroscopy in measuring the biogenic content of the colored blended fuel samples. Preliminary results show the presence of biogenic carbon-derived fingerprints that are absent in fossil-derived sample. However, further work is needed to develop an FTIR-based quantitative method.

09 BIOMASS FUELS↗

A novel photomultiplier tube neutron time-of-flight detector

A traditional neutron time-of-flight (nTOF) detector used in inertial confinement fusion consists of a scintillator coupled with a photomultiplier tube (PMT). The instrument response function (IRF) of such a detector is dominated by the scintillator-light decay. At DT neutron yields larger than 1013 a novel detector consisting of a microchannel-plate photomultiplier tube in a housing without a scintillator (PMT nTOF) can be used to measure DT yield, ion temperature, and neutron velocity. Most of the neutron signal in PMT nTOF is produced from neutron interaction with a PMT window. The direct interaction of neutrons with MCP has negligible contribution. The elimination of the scintillator removes the scintillator decay from the instrument response function and makes the IRF of the PMT nTOF faster, which makes the ion temperature and neutron velocity measurements more accurate. Three PMT nTOFs were deployed on the OMEGA Laser System for the first time to diagnose inertial confinement fusion plasma. Here, the design details, characteristics, and calibration results of these detectors in DT implosions on OMEGA are presented. Recommendations on the use of different PMTs for specific applications are provided.

47 OTHER INSTRUMENTATION↗

Reconstructing 3D asymmetries in laser-direct-drive implosions on OMEGA

Three-dimensional reconstruction algorithms have been developed which determine the hot-spot velocity, hot-spot apparent ion temperature distribution, and fuel areal density distribution present in laser-direct-drive inertial con finement fusion implosions on the OMEGA laser. These reconstructions rely on multiple independent measurements of the neutron energy spectrum emitted from the fusing plasma. Measurements of the neutron energy spectrum on OMEGA are made using a suite of quasi-orthogonal neutron time-of-flight detectors and a magnetic recoil spectrometer. These spectrometers are positioned strategically around the OMEGA target chamber to provide unique 3-D measurements of the conditions of the fusing hot spot and compressed fuel near peak compression. Here, the uncertainties involved in these 3-D reconstructions are discussed and are used to identify a new nTOF diagnostic line of sight which when built will reduce the uncertainty in the hot-spot apparent ion temperature distribution from 0.7 to < 0.4 keV.

47 OTHER INSTRUMENTATION↗