SEARCH · Search NASA
Results for “SCRUBBING”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Fission Product Measurement and Off-Gas Scrubbing for Molten Salt Reactors
The Advanced Reactor Technology (ART) program within the US Department of Energy is developing understanding and technology to help facilitate molten salt reactor commercialization. The off-gas system for MSRs plays an important role in fission product confinement. The strategy used in MSRs is different from that used in pressurized water reactors, where the off-gas mainly mitigates severe accident conditions. Although the details vary depending on the reactor type, the off-gas system of MSRs must reduce radiological emissions to the environment to levels comparable with those mandated for non-MSRs. Systems with molten fuel salt will accumulate material in the headspace: volatile fission products, entrained salt particles, graphite fines, and material that has low solubility in the salt. Operators of thermal fluoride salt reactors with encapsulated fuel will also be concerned about tritium generation and migration. The fission and activation products include noble gases, their daughters, tritium, and aerosolized salt constituents. Their concentrations will generally increase with reactor burnup, depending on the various strategies used for mitigation. Additionally, tritium capture and removal has been reviewed by several groups.
Experimental validation of simplified radionuclide transport bubble scrubbing code in sodium coolant pool
Solid radionuclides released following fuel pin failure may become entrained in gaseous fission products and be rapidly transported through the coolant pool to the cover gas region. Sensitivity studies on radionuclide transport have identified this potential pathway as one of both high concern and high uncertainty. The simplified radionuclide transport scrubbing code utilizes classical aerosol scrubbing mechanisms to model this phenomenon and predict aerosol masses reaching the cover gas region. This paper serves to validate this code in a sodium environment while conducting a parametric study to analyze the effects of aerosol size, bubble size, pool temperature, pool depth, aerosol density, and aerosol concentration. Through a series of experimental tests, it was determined that aerosol sizes ranging from 0.001 to 1.0 µm are of primary concern as aerosols in this range have a ratio of aerosol mass entering the sodium pool from the fuel pin to aerosol mass exiting the sodium pool to the cover gas region of less than 10. Further, the experimental results were found to match the trends found in the scrubbing model closely, but significantly more scrubbing was seen experimentally. Decreasing bubble size and increasing pool depth and aerosol density were all found to increase scrubbing both experimentally and theoretically. Pool temperature was found to have a negligible effect on scrubbing amounts; however, this was largely due to a subsequent increase in bubble size corresponding to increasing temperatures which offset the increase in scrubbing due to increased temperature. Varying aerosol concentration was found to have no effect on scrubbing ratios. A final series of tests was conducted for a more prototypic fuel pin failure with a heterogenous bubble swarm. From these tests, it was found that the experimental scrubbing quantities were larger than for the single bubble case. Overall, it was found that the simplified bubble transport scrubbing code accurately models the trends of the bubble scrubbing but provides a conservative estimate of scrubbing quantities. Model limitations fail to model the complex phenomena present for fission product scrubbing via bubble transport, but match trends seen experimentally.
Benchmark Exercise Report for Experimental Study of Bubble Scrubbing in Water Coolant Pool
Mechanistic assessments of radionuclide release during postulated accidents are expected to be included in advanced reactor license applications. The mechanistic source term (MST) provides an opportunity for vendors to realistically evaluate the radiological consequences of an incident, and may aid in justifying reduced emergency planning zones and plant sites. However, the development of MSTs for advanced nuclear reactors is challenging because there are numerous phenomena that can affect the transport and retention of radionuclides. As part of a trial MST assessment for a metal-fueled, pool-type sodium cooled fast reactor (SFR), led by Argonne National Laboratory, a simplified radionuclide transport code (SRT code) was developed, which includes models to estimate the quantity of fission product aerosols scrubbed in the sodium pool during postulated accident scenarios. In a pool-type SFR, when fission products are released into the coolant pool due to failure of fuel pins, most of the radionuclides are scrubbed by the coolant pool, but some have the potential to migrate to the cover gas region through entrainment within gas bubbles. The SRT code contains a model that evaluates this scrubbing behavior and calculates the fraction of fission product aerosols that reach the cover gas. Due to a lack of available validation data for sodium pool scrubbing, the U.S. Department of Energy funded an experiment at the University of Wisconsin-Madison to measure aerosol scrubbing by injecting air bubbles containing aerosol into a coolant pool. Prior to performing an experiment with liquid sodium, a water loop experiment was performed. Their experiment evaluated the effect of changing the aerosol size, aerosol density, aerosol concentration, bubble size, and pool depth on the aerosol scrubbing efficiency of the pool. In this benchmark experiment, the base tests were conducted by repeated tests of isolated bubbles. Afterwards, more prototypic tests with bubble swarms were performed to evaluate the interactions between the bubbles. The bubble swarm test was able to confirm that a larger amount of aerosol scrubbing occurred than the single bubble test. It was also confirmed that as the bubble size, aerosol density, and pool height increase, the extent of pool scrubbing also increases and does not change with the aerosol concentration. In addition, since the degree of scrubbing is the lowest at aerosol sizes between 0.01 and 1 μm, that is, the largest amount of aerosol is emitted, it was confirmed that the analysis of this size in MST is the most important. This benchmark experiment informs the direction of future sodium experiments.
eRHIC Beam Scrubbing
We propose using beam scrubbing to mitigate the electron cloud effect in the eRHIC. The bunch number is adjusted below the heat load limit, then it increases with the reduced secondary electron yield resulted from the beam scrubbing, up to the design bunch number. Since the electron density threshold of beam instability is lower at the injection, a preliminary injection scrubbing should go first, where large chromaticity can be used to keep the beam in the ring for scrubbing. After that, the beam can be ramped to full energy, allowing physics scrubbing. Simulations demonstrated that with beam scrubbing in a reasonable period of time, the eRHIC baseline design is feasible.
An Assessment of Fission Product Scrubbing in Sodium Pools Following a Core Damage Event in a Sodium Cooled Fast Reactor
The U.S. Nuclear Regulatory Commission has stated that mechanistic source term (MST) calculations are expected to be required as part of the advanced reactor licensing process. A recent study by Argonne National Laboratory has concluded that fission product scrubbing in sodium pools is an important aspect of an MST calculation for a sodium-cooled fast reactor (SFR). To model the phenomena associated with sodium pool scrubbing, a computational tool, developed as part of the Integral Fast Reactor (IFR) program, was utilized in an MST trial calculation. This tool was developed by applying classical theories of aerosol scrubbing to the decontamination of gases produced as a result of postulated fuel pin failures during an SFR accident scenario. The model currently considers aerosol capture by Brownian diffusion, inertial deposition, and gravitational sedimentation. The effects of sodium vapour condensation on aerosol scrubbing are also treated. This paper provides details of the individual scrubbing mechanisms utilized in the IFR code as well as results from a trial mechanistic source term assessment led by Argonne National Laboratory in 2016.
Analyzing the effectiveness of a frame-level redundancy scrubbing technique for SRAM-based FPGAs
Radiation effects such as soft errors are the major threat to the reliability of SRAM-based FPGAs. This work analyzes the effectiveness in correcting soft errors of a novel scrubbing technique using internal frame redundancy called Frame-level Redundancy Scrubbing (FLR-scrubbing). This correction technique can be implemented in a coarse grain TMR design. The FLR-scrubbing technique was implemented on a mid-size Xilinx Virtex-5 FPGA device used as a case study. The FLR-scrubbing technique was tested under neutron radiation and fault injection. Implementation results demonstrated minimum area and energy consumption overhead when compared to other techniques. The time to repair the fault is also improved by using the Internal Configuration Access Port (ICAP). Lastly, neutron radiation test results demonstrated that the proposed technique is suitable for correcting accumulated SEUs and MBUs.
AmeriFlux FLUXNET-1F US-KS2 Kennedy Space Center (scrub oak)
This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-KS2 Kennedy Space Center (scrub oak). This is the FLUXNET version of the carbon flux data for the site US-KS2 Kennedy Space Center (scrub oak) produced by applying the standard ONEFlux (1F) software. Site Description - The Kennedy Space Center Scrub Oak site is located within the Merritt Island National Wildlife Refuge at the Kennedy Space Center (KSC) on the east coast of central Florida. Situated in a 10 ha scrub oak ecosystem, the surrounding stand was completely burned by a prescribed fire in 1996. The purpose of the burn was to control understory fuel load, which has been a common practice since 1969. Within a few weeks of the 1996 burn, the stand began to naturally regenerate from roots and rhizomes. Most scrub oak stands in the region undergo a 7 to 10 year disturbance cycle, mostly related to fire or hurricane activity. A severe drought gripped most of Florida beginning in 1998 until the later half of 2001 resulting in four years of relatively low amount of annual rainfall. Exceptionally high annual rainfall amount in 2004 was the result of a pair of hurricanes that hit the area in August and September of 2004. Prevaling wind directions for the site are as follows: W to NW in the winter, afternoon E sea breeze in the summer.
AmeriFlux US-KS2 Kennedy Space Center (scrub oak)
This is the AmeriFlux version of the carbon flux data for the site US-KS2 Kennedy Space Center (scrub oak). Site Description - The Kennedy Space Center Scrub Oak site is located within the Merritt Island National Wildlife Refuge at the Kennedy Space Center (KSC) on the east coast of central Florida. Situated in a 10 ha scrub oak ecosystem, the surrounding stand was completely burned by a prescribed fire in 1996. The purpose of the burn was to control understory fuel load, which has been a common practice since 1969. Within a few weeks of the 1996 burn, the stand began to naturally regenerate from roots and rhizomes. Most scrub oak stands in the region undergo a 7 to 10 year disturbance cycle, mostly related to fire or hurricane activity. A severe drought gripped most of Florida beginning in 1998 until the later half of 2001 resulting in four years of relatively low amount of annual rainfall. Exceptionally high annual rainfall amount in 2004 was the result of a pair of hurricanes that hit the area in August and September of 2004. Prevaling wind directions for the site are as follows: W to NW in the winter, afternoon E sea breeze in the summer.
Impact of elevated CO2 on a Florida Scrub-oak Ecosystems
Since May of 1996, we have conducted an experiment in Florida Scrub Oak to determine the impact of elevated atmospheric CO 2 and climate change on carbon, water, and nutrient cycling in this important terrestrial ecosystem. Florida scrub oak is the name for a collective of species occupying much of the Florida peninsula. The dominant tree species are oaks and the dwarf structure of this community makes it an excellent system in which to test hypotheses regarding the potential capacity of woody ecosystems to assimilate and sequester anthropogenic carbon. Scrub oak is fire dependent with a return cycle of 10-15 years, a time which would permit an experiment to follow the entire cycle. Our site is located on Cape Canaveral at the Kennedy Space Center, Florida. After burning in 1995, we built 16 open top chambers, half of which have been fumigated with pure CO 2 sufficient to raise the concentration around the plants to 350 ppm above ambient. In the intervening 10 years we have non destructively measured biomass of shoots and roots, ecosystem gas exchange using chambers and eddy flux, leaf photosynthesis and respiration, soil respiration, and relevant environmental factors such as soil water availability, temperature, light, etc.
Sample Results From The Extraction, Scrub, And Strip Test For The Blended NGS Solvent
This report summarizes the results of the extraction, scrub, and strip testing for the September 2013 sampling of the Next Generation Solvent (NGS) Blended solvent from the Modular Caustic Side-Solvent Extraction Unit (MCU) Solvent Hold Tank. MCU is in the process of transitioning from the BOBCalixC6 solvent to the NGS Blend solvent. As part of that transition, MCU has intentionally created a blended solvent to be processed using the Salt Batch program. This sample represents the first sample received from that blended solvent. There were two ESS tests performed where NGS blended solvent performance was assessed using either the Tank 21 material utilized in the Salt Batch 7 analyses or a simulant waste material used in the V-5/V-10 contactor testing. This report tabulates the temperature corrected cesium distribution, or D Cs values, step recovery percentage, and actual temperatures recorded during the experiment. This report also identifies the sample receipt date, preparation method, and analysis performed in the accumulation of the listed values. The calculated extraction D Cs values using the Tank 21H material and simulant are 59.4 and 53.8, respectively. The DCs values for two scrub and three strip processes for the Tank 21 material are 4.58, 2.91, 0.00184, 0.0252, and 0.00575, respectively. The D-values for two scrub and three strip processes for the simulant are 3.47, 2.18, 0.00468, 0.00057, and 0.00572, respectively. These values are similar to previous measurements of Salt Batch 7 feed with lab-prepared blended solvent. These numbers are considered compatible to allow simulant testing to be completed in place of actual waste due to the limited availability of feed material.
Extraction, scrub, and strip test results for the salt waste processing facility caustic side solvent extraction solvent example
An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 12.9, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.
Extraction, scrub, and strip test results for the solvent transfer to salt waste processing facility
The Savannah River National Laboratory (SRNL) prepared approximately 240 gallons of Caustic-Side Solvent Extraction (CSSX) solvent for use at the Salt Waste Processing Facility (SWPF). An Extraction, Scrub, and Strip (ESS) test was performed on a sample of the prepared solvent using a salt solution prepared by Parsons to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams. This data will be used by Parsons to help qualify the solvent for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 15.5, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.
Extraction, Scrub, and Strip Test Results for the Salt Waste Processing Facility Caustic Side Solvent Extraction Solvent Sample
An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D( Cs )), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D( Cs ) measured 12.5, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges. This revision was created to correct an error. The previous revision used an incorrect set of temperature correction coefficients which resulted in slight deviations from the correct D( Cs ) results.
Extraction, Scrub, and Strip Test Results for the Second Solvent Lot Qualification Sample for the Salt Waste Processing Facility
An Extraction, Scrub, and Strip (ESS) test was performed on the qualification sample from the second lot of Caustic-Side Solvent Extraction (CSSX) solvent for the Salt Waste Processing Facility (SWPF). Testing used simulated salt solution to determine cesium distribution ratios (D( Cs )), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams. This data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D( Cs ) measured 14.4, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.
Extraction, Scrub, and Strip Test Results for the Salt Waste Processing Facility Caustic Side Solvent Extraction Solvent Sample
An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D (Cs) ), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D (Cs) measured 13.2, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges
Development and characterization of microsatellite loci for the endangered scrub lupine, Lupinus aridorum (Fabaceae)
Premise of the study: Microsatellite primers were developed in scrub lupine ( Lupinus aridorum , Fabaceae), an endemic species to Florida that is listed as endangered in the United States, to assess connectivity among populations, identify hybrids, and examine genetic diversity. Methods and Results: We isolated and characterized 12 microsatellite loci polymorphic in scrub lupine or in closely related species (i.e., sky‐blue lupine [ L. diffusus ] and Gulf Coast lupine [ L. westianus ]). Loci showed low to moderate polymorphism, ranging from two to 14 alleles per locus and 0.01 to 0.86 observed heterozygosity. Conclusions: These loci are the first developed for Florida species of lupine and will be used to determine differentiation among species and to aid in conservation of the endangered scrub lupine.
Sample Results from the Next Generation Solvent Program Real Waste Extraction-Scrub-Strip Testing
Savannah River National Laboratory (SRNL) performed multiple Extraction-Scrub-Strip (ESS) testing using real waste solutions, and three Next Generation Solvent (NGS) variations, which included radiologically clean pure NGS, a blend of radiologically clean NGS and radiologically clean BOBCalixC6 (NGS-MCU), and a blend of radiologically clean NGS and radiologically contaminated BOBCalixC6 from the MCU Solvent system. The results from the tests indicate that both the NGS and the NGS-MCU blend exhibit adequate extraction, scrub and strip behavior.