Search NASA⌕ Search

SEARCH · Search NASA

Results for “SENSOR COUNTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Improved sensor counts micrometeoroid penetrations

A sensor, consisting of a thin dual-capacitor assembly with an outer film of thermal-control material, is used to detect micrometeoroid particles. A coincidence counting circuit is used to count the penetrations.

Davison, E. H.↗

Optimizing Sensor Count and Placement to Detect Bond Wire Lift-Offs and Surface Defects in High-Power IGBT Modules Using Low-Cost Piezo-Electric Resonators

This manuscript presents the most recent results and findings to identify bond wire lift-offs and surface defects in high-power isolated gate bipolar junction transistor (IGBT) modules. The authors of this manuscript formerly proposed a low-cost, piezoelectric resonator-based measurement unit to detect bond wire related degradation in larger IGBT modules. Since high-power IGBT modules are expensive, it was apparent that evaluating our proposed method by inducing controlled damage to fresh (new) IGBTs may not be cost-effective especially when multiple sets of data need to be captured by inducing damage to different levels. In order to overcome this limitation, IGBT bond wires have been mimicked using a 3D printed enclosure, a PCB, and copper wires with dimensions very closely resembling a real IGBT. Using this method, multiple test devices can be built at the cost of a real IGBT, and the proposed technique could be fine-tuned without damaging expensive, real IGBTs. Our recent findings can be used to determine real IGBT degradation and bond wire lift-offs using only two sensors, as opposed to six transducers used in the first iteration of the setup. In addition to optimizing the sensor count, we have also identified the best possible locations of these sensors by attempting multiple placements inside the IGBT casing.

condition monitoring↗

Multiple-Event, Single-Photon Counting Imaging Sensor

The single-photon counting imaging sensor is typically an array of silicon Geiger-mode avalanche photodiodes that are monolithically integrated with CMOS (complementary metal oxide semiconductor) readout, signal processing, and addressing circuits located in each pixel and the peripheral area of the chip. The major problem is its single-event method for photon count number registration. A single-event single-photon counting imaging array only allows registration of up to one photon count in each of its pixels during a frame time, i.e., the interval between two successive pixel reset operations. Since the frame time can t be too short, this will lead to very low dynamic range and make the sensor merely useful for very low flux environments. The second problem of the prior technique is a limited fill factor resulting from consumption of chip area by the monolithically integrated CMOS readout in pixels. The resulting low photon collection efficiency will substantially ruin any benefit gained from the very sensitive single-photon counting detection. The single-photon counting imaging sensor developed in this work has a novel multiple-event architecture, which allows each of its pixels to register as more than one million (or more) photon-counting events during a frame time. Because of a consequently boosted dynamic range, the imaging array of the invention is capable of performing single-photon counting under ultra-low light through high-flux environments. On the other hand, since the multiple-event architecture is implemented in a hybrid structure, back-illumination and close-to-unity fill factor can be realized, and maximized quantum efficiency can also be achieved in the detector array.

Zheng, Xinyu↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗

Photon-counting image sensors for the ultraviolet

An investigation on specific performance details of photon counting, ultraviolet image sensors having 2-dimensional formats is reviewed. In one study, controlled experiments were performed which compare the quantum efficiencies, in pulse counting mode, of CsI photocathodes deposited on: (1) the front surface of a microchannel plate (MCP), (2) a solid surface in front of an MCP, and (3) an intensified CCD image sensor (ICCD) where a CCD is directly bombarded by accelerated photoelectrons. Tests indicated that the detection efficiency of the CsI-coated MCP at 1026 A is lower by a factor of 2.5 than that of the MCP with a separate, opaque CsI photocathode, and the detection efficiency ratio increases substantially at longer wavelengths (ratio is 5 at 1216 A and 20 at 1608 A).

Jenkins, E. B.↗

Laboratory testing methods to evaluate the reliability of occupancy sensors for commercial building applications

The energy performance of commercial buildings is greatly influenced by occupants which are highly variable and among the most unpredictable components of a building's operation. While most building control systems use fixed, predetermined occupancy schedules, these fixed occupancy levels can be quite different from actual occupancy. This can cause unnecessary energy consumption, particularly from heating, ventilation, and air conditioning (HVAC) and lighting systems which are responsible for approximately 60% of commercial buildings' energy use. The use of occupancy counting sensor systems integrated with building management system controls is one method that can be used to improve the energy-consuming performance of buildings. However, there is no standardized universal methodology and metrics to evaluate their reliability. The aim of this research is to develop a uniform evaluation methodology to assess the reliability of occupancy counting sensor systems in a controlled laboratory environment. The developed testing methodology includes both “typical” scenarios representing the occupancy scenarios of a typical commercial building, and “failure” testing scenarios which represent a range of potential scenarios that may impact a sensor system's reliability. These methods were then implemented in a case study to evaluate the performance of two novel occupancy counting sensor systems (i.e., door-centric, and camera-based). Results suggest that typical testing results can be used to compare the overall performance of the occupancy counting sensor systems; however, failure testing is also important to understand the weaknesses of the sensor system in order to select the suitable one for the intended use of the commercial building. In addition, the proposed methodology includes a modified confusion matrix which enables the ability to identify if failures are caused by over or under counting occupants and to what extent this occurs over the testing period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photon counting image sensor development for astronomical applications

Specially built intensified CCD (ICCD) detector tubes were purchased and the performance of the electron bombardment process was investigated. In addition to studying the signal characteristics of the photoevents, there was interest in demonstrating that back-illuminated chips were not susceptible to radiation damage to their clocking electrodes. How to perform a centroid analysis for a 2-dimensional Gaussian distribution of charge is described. Measurement of the projection (along columns or rows) of the average charge spread profile is discussed. The development and flight of the Interstellar Medium Absorption Profile Spectrograph (IMAPS) is discussed.

Jenkins, Edward B.↗

HYTHIRM Radiance Modeling and Image Analyses in Support of STS-119, STS-125 and STS-128 Space Shuttle Hypersonic Re-entries

We provide the first geometrically accurate (i.e., 3-D) temperature maps of the entire windward surface of the Space Shuttle during hypersonic reentry. To accomplish this task we began with estimated surface temperatures derived from CFD models at integral high Mach numbers and used them, the Shuttle's surface properties and reasonable estimates of the sensor-to-target geometry to predict the emitted spectral radiance from the surface (in units of W sr-1 m-2 nm-1). These data were converted to sensor counts using properties of the sensor (e.g. aperture, spectral band, and various efficiencies), the expected background, and the atmosphere transmission to inform the optimal settings for the near-infrared and midwave IR cameras on the Cast Glance aircraft. Once these data were collected, calibrated, edited, registered and co-added we formed both 2-D maps of the scene in the above units and 3-D maps of the bottom surface in temperature that could be compared with not only the initial inputs but also thermocouple data from the Shuttle itself. The 3-D temperature mapping process was based on the initial radiance modeling process. Here temperatures were guessed for each node in a well-resolved 3-D framework, a radiance model was produced and compared to the processed imagery, and corrections to the temperature were estimated until the iterative process converged. This process did very well in characterizing the temperature structure of the large asymmetric boundary layer transition the covered much of the starboard bottom surface of STS-119 Discovery. Both internally estimated accuracies and differences with CFD models and thermocouple measurements are at most a few percent. The technique did less well characterizing the temperature structure of the turbulent wedge behind the trip due to limitations in understanding the true sensor resolution. (Note: Those less inclined to read the entire paper are encouraged to read an Executive Summary provided at the end.)

Gibson, David M.↗

Massively distributed fiber strain sensing using Brillouin lasing

Brillouin based distributed fiber sensors present a unique set of characteristics amongst fiber sensing architectures. They are able to measure absolute strain and temperature over long distances, with high spatial resolution, and very large dynamic range in off-the-shelf fiber. However, Brillouin sensors traditionally provide only modest sensitivity due to the weak dependence of the Brillouin frequency on strain and the high signal to noise ratio required to identify the resonance’s peak frequency to within a small fraction of its linewidth. Recently, we introduced a technique which substantially improves the precision of Brillouin fiber sensors by exciting a series of lasing modes in a fiber loop cavity that experience Brillouin amplification at discrete locations in the fiber. The narrow-linewidth and high intensity of the lasing modes enabled ultra-low noise Brillouin sensors with large dynamic range. However, our initial demonstration was only modestly distributed: measuring strain at 40, non-contiguous positions along a 400 m fiber. In this work, we greatly extend this methodology to enable fully distributed sensing at 1000 contiguous locations along 3.5 km of fiber—an order of magnitude increase in sensor count and range. This highly-multiplexed Brillouin fiber laser sensor provides a strain noise as low as 34 nɛ/√Hz and we analyze the limiting factors in this approach.

47 OTHER INSTRUMENTATION↗

Electronic 4-wheel drive control device

The internal rotation torque generated during operation of a 4-wheel drive vehicle is reduced using a control device whose clutch is attached to one part of the rear-wheel drive shaft. One torque sensor senses the drive torque associated with the rear wheel drive shaft. A second sensor senses the drive torque associated with the front wheel drive shaft. Revolution count sensors sense the revolutions of each drive shaft. By means of a microcomputer, the engagement of the clutch is changed to insure that the ratio of the torque sensors remains constant.

Hayato, S.↗

Strapdown cost trend study and forecast

The potential cost advantages offered by advanced strapdown inertial technology in future commercial short-haul aircraft are summarized. The initial procurement cost and six year cost-of-ownership, which includes spares and direct maintenance cost were calculated for kinematic and inertial navigation systems such that traditional and strapdown mechanization costs could be compared. Cost results for the inertial navigation systems showed that initial costs and the cost of ownership for traditional triple redundant gimbaled inertial navigators are three times the cost of the equivalent skewed redundant strapdown inertial navigator. The net cost advantage for the strapdown kinematic system is directly attributable to the reduction in sensor count for strapdown. The strapdown kinematic system has the added advantage of providing a fail-operational inertial navigation capability for no additional cost due to the use of inertial grade sensors and attitude reference computers.

Eberlein, A. J.↗

Prelaunch Calibrations of the Clouds and the Earth's Radiant Energy System (CERES) Tropical Rainfall Measuring Mission and Earth Observing System Morning (EOS-AM1) Spacecraft Thermistor Bolometer Sensors

The Clouds and the Earth's Radiant Energy System (CERES) spacecraft scanning thermistor bolometer sensors measure earth radiances in the broadband shortwave solar (O.3 - 5.0 micron and total (0.3 to 100 microns) spectral bands as well as in the 8-12 microns water vapor window spectral band. On November 27, 1997, the launch of the Tropical Rainfall Measuring Mission (TRMM) spacecraft placed the first set of CERES sensors into orbit, and 30 days later, the sensors initiated operational measurements of the earth radiance fields. In 1998, the Earth Observing System morning (EOS-AM1) spacecraft will place the second and third sensor sets into orbit. The prelaunch CERES sensors' count conversion coefficients (gains and zero-radiance offsets) were determined in vacuum ground facilities. The gains were tied radiometrically to the International Temperature Scale of 1990 (ITS-90). The gain determinations included the spectral properties (reflectance, transmittance, emittance, etc.) of both the sources and sensors as well as the in-field-of-view (FOV) and out-of-FOV sensor responses. The resulting prelaunch coefficients for the TRMM and EOS-AM1 sensors are presented. Inflight calibration systems and on-orbit calibration approaches are described, which are being used to determine the temporal stabilities of the sensors' gains and offsets from prelaunch calibrations through on-orbit measurements. Analyses of the TRMM prelaunch and on-orbit calibration results indicate that the sensors have retained their ties to ITS-90 at accuracy levels better than /- 0.3% between the 1995 prelaunch and 1997 on-orbit calibrations.

Lee, Robert B., III↗

Radiometric calibration and atmospheric correction of satellite and aircraft data for FIFE

The satellite and aircraft radiometric calibration and atmospheric correction work carried out as part of the first International Satellite Land Surface Climatology Project (ISLSCP) Field Experiment (FIFE) are summarized. A large volume (120 Gbytes) of radiometric data were acquired and derived from a number of different instruments on a variety of platforms. The same basic procedure was applied to each instrument: derive the most recent calibration coefficients for converting sensor counts to reflective spectral radiances; correct the radiances for earth-sun distance variations and incident solar spectral irradiance within the bandpass of each respective instrument channel at the top of the atmosphere; characterize the atmosphere for aerosols and absorbing gases; and derive apparent surface reflectance by correcting the exoatmospheric values for atmospheric attenuation. The same basic approach was used for surface temperature derivation. The results of this processing were verified by surface measurements, and corroborated by sensor intercomparisons.

Goetz, Scott J.↗

Coastal zone color scanner 'system calibration': A retrospective examination

During its lifetime the Coastal Zone Color Scanner (CZCS) produced approximately 66,000 images. These have been placed in an archive of 'raw' radiance (sensor counts) in a subsampled format that is easily accessible. They have also been processed to form global fields, at reduced resolution, of normalized water-leaving radiance, phytoplankton pigments, and diffuse attenuation coefficient. Using this archive, we have tried to characterize some aspects of the 'system calibration' for the 8-year lifetime of CZCS. Specifically, we have assumed that the sensitivity of the red band decayed in a simple manner similar to the well-known long-term degradation of the shorter-wavelength bands, and we examined the sensitivity of the green and yellow bands by computing the globally averaged water-leaving radiance, over 10-day periods, for all of the imagery. The results provided evidence that in addition to the long-term degradation, short-term (2 weeks to 1 month) variations in the radiometric sensitivity of these bands started in early fall 1981 and continued for the rest of the mission. In contrast, the data suggested the absence of such variations prior to August 1981. It is reasonable to believe that the sensitivity of the blue (and probably the red) band underwent such variations as well; however our methodology cannot be used to study the other bands. Thus, after these fluctuations began, the actual values of CZCS - estimated pigment concentrations at a given location should be viewed with skepticism; however, the global patterns of derived pigment concentrations should be valid. Had an extensive set of surface measurements of water-leaving radiance, e.r., from moored buoyes or drifters, had been available during the CZCS mission, these fluctuations could have been removed from the data set, and this would have greatly increased its value. The lessons learned from CZCS that is, the requirement of good radiometric calibration and stability and the necessity of 'sea truth' stations to monitor the performance of the system (sensor plus algorithms), are being applied to the sea-viewing wide-field-of-view senso (Sea WiFS) scheduled for launch in August 1993.

Evans, Robert H.↗

Formulation and solution approach for calibrating activity-based travel demand model-system via microsimulation

This study addresses the problem of calibrating utility-maximizing nested logit activity-based travel demand model-systems. After estimation, it is common practice to use aggregate measurements to calibrate the estimated model-system’s parameters prior to their application in transportation planning, policy making, and operations. However, calibration of activity-based model-systems has received much less attention. Existing calibration approaches are myopic heuristics in the sense that they do not consider the fundamental inter-dependencies among choice-models and do not have a systematic way to adjust model parameters. Also, other purely simulation-based approaches do not perform well in large-scale applications. In this study, we focus on utility-maximizing nested logit activity-based model-systems and calibrating aggregate statistics such as activity shares, mode shares, time-dependent & mode-specific OD flows, and time-dependent & mode-specific sensor counts. We formulate the calibration problem as a simulation-based optimization problem and propose a stochastic gradient-based solution procedure to solve it. The solution procedure relies on microsimulation to calculate expectations of the aggregate statistics of interest to the calibration problem. Additionally, we derive approximate analytical expressions for the gradient of the objective function —that are evaluated through microsimulation on mini-batches of the population. The proposed solution procedure is sensitive to the fundamental structure of the activity-based model-system and is non-myopic in considering the dependencies across its model components. The formulated optimization problem is non-convex, highly nonlinear, and potentially has multiple-minima. Lastly, we show —through a real-world application— that the proposed solution procedure outperforms other state-of-the-art purely simulation-based optimization approaches in terms of computational efficiency, stability, and convergence. We also compare various gradient-based solution algorithms to determine the best algorithm to update the parameters. This work has the potential to facilitate wider and easier application of activity-based model-systems.

97 MATHEMATICS AND COMPUTING↗