Search NASA⌕ Search

SEARCH · Search NASA

Results for “SERFE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Constraints on axion-like dark matter from a SERF comagnetometer

Ultralight axion-like particles are well-motivated relics that might compose the cosmological dark matter and source anomalous time-dependent magnetic fields. We report on terrestrial bounds from the Noble And Alkali Spin Detectors for Ultralight Coherent darK matter (NASDUCK) collaboration on the coupling of axion-like particles to neutrons and protons. The detector uses nuclei of noble-gas and alkali-metal atoms and operates in the Spin-Exchange Relaxation-Free (SERF) regime, achieving high sensitivity to axion-like dark matter fields. Conducting a month-long search, we cover the mass range of 1.4 × 10 -12 eV/c 2 to 2 × 10 -10 eV/c 2 and provide limits which supersede robust astrophysical bounds, and improve upon previous terrestrial constraints by over two orders of magnitude for many masses within this range for protons, and up to two orders of magnitude for neutrons. These are the sole reliable terrestrial bounds reported on the coupling of protons with axion-like dark matter, covering an unexplored terrain in its parameter space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

1st Quarter Emergency Drill at SERF: Player's Briefing [Slides]

The purpose of this briefing is to provide drill information to players participating in the 1st Quarter Emergency Drill at SERF as follows: Communicate general drill information and conduct expectations; Outline roles and responsibilities; and Provide safely and securely guidance to ensure unsafe act or security violation does not occur during the drill.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Water Quality for High Performance Computing

To support future generations of high performance computers, the Advanced Simulation and Computing Program has a mission need for 80MW of peak power and cooling. Currently the water for the cooling towers at the Strategic Computing Complex (SCC) are cooled by the LANL waste water treated Sanitary Effluent Recovery Facility (SERF) or potable water from the county. The SCC cooling towers currently operate by cycling water between 2-3 cycles of concentration (COC), which is less than the ideal 6 cycles for maximizing water usage. SERF is the ideal water supplier, however when it’s not available potable water is used. The amount of water that the SCC needs nominally is around 45 Million-Gallons/Year (MGY). The future super computer infrastructure (FSI) will need around 125 MGY nominally. SERF is approaching its production limit for reclaimed water. In order to avoid using 100% potable water for the FSI, the option of using non-potable reuse water from Los Alamos County (LAC) was analyzed. This project scope is to focus on the water quality needed for the new super computer cooling towers. Once water quality needs are established, the ideal treatment process needs to be determined. Due to high silica content in water at Los Alamos, emphasis has been placed on treatment processes to remove silica. SERF’s current and future ability to treat water was assessed, as well as the cost of running a SERF like facility or alternative.

97 MATHEMATICS AND COMPUTING↗

The atomic magnetometer: A new era in biomagnetism

The high cost and impracticality of SQUID (Superconducting QUantum Interference Device) magnetometers has limited the expansion of magnetoencephalography (MEG) and magnetocardiography (MCG), especially in countries where the cost of liquid helium is high. A recent breakthrough, however, has the potential to radically change this situation. In 2003, a group at Princeton University demonstrated an atomic magnetometer, known as the SERF (spin-exchange free relaxation) magnetometer, with unprecedented sensitivity. Since then, several research groups have utilized SERF magnetometers to record MEG, MCG, and fetal MCG signals. Despite some modest drawbacks, it now seems almost certain that SERF magnetometers can replace SQUIDs for many applications. With a price tag that is likely to be far less than that of SQUIDs, SERF magnetometers can propel the next wave of growth in biomagnetism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analyzing the Effects of Water Output Rates on the Strategic Computing Complex

At the Los Alamos National Laboratory, the Strategic Computing Complex (SCC) requires chilled water to properly allow its supercomputers and other systems to properly function. In order to do so, the SCC heavily relies on the use of treated water from the Sanitary Waste Water System (SWWS) and the Sanitary Effluent Reclamation Facility (SERF). Industrial water that can be reused, such as from toilets and sinks, as well as rain and well water, arrives at the SWWS where it is aerated and processed. From there, a portion of the water can evaporate, while some of it is removed in the form of sludge or discharged into the nearby canyon. However, a majority of this reuse water is transported to SERF, where it is further processed and treated. Here is the location where this water becomes “usable” once again. From there, is transported to cooling towers where the water becomes chilled and can properly cool the supercomputers at the SCC. In fact, nearly all of the reuse water utilized by the SCC is treated and processed at SERF. This analysis specifically examines the water that leaves SWWS for SERF.

54 ENVIRONMENTAL SCIENCES↗

Saving Water at Los Alamos National Laboratory

Los Alamos National Laboratory decreased its water usage by 26 percent in 2014, with about one-third of the reduction attributable to using reclaimed water to cool a supercomputing center. The Laboratory's goal during 2014 was to use only re-purposed water to support the mission at the Strategic Computing Complex. Using reclaimed water from the Sanitary Effluent Reclamation Facility, or SERF, substantially decreased water usage and supported the overall mission. SERF collects industrial wastewater and treats it for reuse. The reclamation facility contributed more than 27 million gallons of re-purposed water to the Laboratory's computing center, a secured supercomputing facility that supports the Laboratory’s national security mission and is one of the institution’s larger water users. In addition to the strategic water reuse program at SERF, the Laboratory reduced water use in 2014 by focusing conservation efforts on areas that use the most water, upgrading to water-conserving fixtures, and repairing leaks identified in a biennial survey.

54 ENVIRONMENTAL SCIENCES↗

Search for exotic spin-dependent interactions with a spin-exchange relaxation-free magnetometer

We propose a novel experimental approach to explore exotic spin-dependent interactions using a spin-exchange relaxation-free (SERF) magnetometer, the most sensitive noncryogenic magnetic-field sensor. This approach studies the interactions between optically polarized electron spins located inside a vapor cell of the SERF magnetometer and unpolarized or polarized particles of external solid-state objects. The coupling of spin-dependent interactions to the polarized electron spins of the magnetometer induces the tilt of the electron spins, which can be detected with high sensitivity by a probe laser beam similarly as an external magnetic field. Lastly, we estimate that by moving unpolarized or polarized objects next to the SERF Rb vapor cell, the experimental limit to the spin-dependent interactions can be significantly improved over existing experiments, and new limits on the coupling strengths can be set in the interaction range below 10 –2 m.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A fast determination method for transverse relaxation of spin-exchange-relaxation-free magnetometer

We propose a fast and accurate determination method for transverse relaxation of the spin-exchange-relaxation-free (SERF) magnetometer. This method is based on the measurement of magnetic resonance linewidth via a chirped magnetic field excitation and the amplitude spectrum analysis. Compared with the frequency sweeping via separate sinusoidal excitation, our method can realize linewidth determination within only few seconds and meanwhile obtain good frequency resolution. Therefore, it can avoid the drift error in long term measurement and improve the accuracy of the determination. As the magnetic resonance frequency of the SERF magnetometer is very low, we include the effect of the negative resonance frequency caused by the chirp and achieve the coefficient of determination of the fitting results better than 0.998 with 95% confidence bounds to the theoretical equation. The experimental results are in good agreement with our theoretical analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the operation temperature in the spin-exchange relaxation free magnetometer

We study the influence of the cell temperature on the sensitivity of the spin-exchange relaxation free (SERF) magnetometer and analyze the possibility of operating at a low temperature. Utilizing a 25 × 25 × 25 mm{sup 3} Cs vapor cell with a heating temperature of 85 {sup ∘}C, which is almost half of the value of potassium, we obtain a linewidth of 1.37 Hz and achieve a magnetic field sensitivity of 55 fT/Hz{sup 1/2} in a single channel. Theoretical analysis shows that fundamental sensitivity limits of this device with an active volume of 1 cm{sup 3} could approach 1 fT/Hz{sup 1/2}. Taking advantage of the higher saturated vapor pressure, SERF magnetometer based on Cs opens up the possibility for low cost and portable sensors and is particularly appropriate for lower temperature applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Suppression of vapor cell temperature error for spin-exchange-relaxation-free magnetometer

This paper presents a method to reduce the vapor cell temperature error of the spin-exchange-relaxation-free (SERF) magnetometer. The fluctuation of cell temperature can induce variations of the optical rotation angle, resulting in a scale factor error of the SERF magnetometer. In order to suppress this error, we employ the variation of the probe beam absorption to offset the variation of the optical rotation angle. The theoretical discussion of our method indicates that the scale factor error introduced by the fluctuation of the cell temperature could be suppressed by setting the optical depth close to one. In our experiment, we adjust the probe frequency to obtain various optical depths and then measure the variation of scale factor with respect to the corresponding cell temperature changes. Our experimental results show a good agreement with our theoretical analysis. Under our experimental condition, the error has been reduced significantly compared with those when the probe wavelength is adjusted to maximize the probe signal. The cost of this method is the reduction of the scale factor of the magnetometer. However, according to our analysis, it only has minor effect on the sensitivity under proper operating parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin-exchange relaxation-free magnetometer with nearly parallel pump and probe beams

We constructed a spin-exchange relaxation-free (SERF) magnetometer with a small angle between the pump and probe beams facilitating a multi-channel design with a flat pancake cell. This configuration provides almost complete overlap of the beams in the cell, and prevents the pump beam from entering the probe detection channel. By coupling the lasers in multi-mode fibers, without an optical isolator or field modulation, we demonstrate a sensitivity of 10 fT$/\sqrt{\text{Hz}}$ for frequencies between 10 Hz and 100 Hz. In addition to the experimental study of sensitivity, we present a theoretical analysis of SERF magnetometer response to magnetic fields for small-angle and parallel-beam configurations, and show that at optimal DC offset fields the magnetometer response is comparable to that in the orthogonal-beam configuration. Based on the analysis, we also derive fundamental and probe-limited sensitivities for the arbitrary non-orthogonal geometry. The expected practical and fundamental sensitivities are of the same order as those in the orthogonal geometry. As a result, we anticipate that our design will be useful for magnetoencephalography (MEG) and magnetocardiography (MCG) applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Searching for new spin-dependent interactions with SmCo 5 spin sources and a spin-exchange-relaxation-free comagnetometer

We propose a novel method to search for possible new macroscale spin- and/or velocity-dependent forces (SVDFs) based on specially designed SmCo 5 spin sources and a spin exchange relaxation-free (SERF) comagnetometer. A simulation shows that, by covering a SmCo 5 permanent magnet with a layer of pure iron, a high net spin density source of about $1×10^{22}/cm^3$ could be obtained. Taking advantages of the high spin density of this iron-shielded SmCo 5 and the high sensitivity of the SERF, the proposed method could set up new limits of greater than 10 orders of magnitude more sensitive than those from previous experiments or proposals in exploring SVDFs in force ranges larger than 1 cm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental Constraint on an Exotic Spin- and Velocity-Dependent Interaction in the Sub-meV Range of Axion Mass with a Spin-Exchange Relaxation-Free Magnetometer

Here, we conducted a search for an exotic spin- and velocity-dependent interaction for polarized electrons with an experimental approach based on a high-sensitivity spin-exchange relaxation-free (SERF) magnetometer, which serves as both a source of polarized electrons and a magnetic-field sensor. The experiment aims to sensitively detect magnetic-fieldlike effects from the exotic interaction between the polarized electrons in a SERF vapor cell and unpolarized nucleons of a closely located solid-state mass. We report experimental results on the interaction with 82 h of data averaging, which sets an experimental limit on the coupling strength around 10 –19 for the axion mass m a ≲ 10 –3 eV, within the important axion window.

74 ATOMIC AND MOLECULAR PHYSICS↗

Los Alamos National Laboratory Reclaimed Water Usage for Data Centers: A Case Study

Water is a valuable resource that is all too often ignored when thinking about sustainability and High-Performance Computing (HPC). Los Alamos National Laboratory (LANL) found a solution to eliminate the amount of potable water usage needed for cooling HPC facilities. The Sanitary Effluent Reclamation Facility (SERF) was constructed in 2013 with the main purpose of removing silica from water in Los Alamos, New Mexico, to increase the cycles of concentration for the HPC Complex. SERF enabled Los Alamos National Laboratory to remove silica, reclaim effluent from the wastewater treatment plant and reduce the usage of potable water for HPC cooling.

54 ENVIRONMENTAL SCIENCES↗

Ultra-sensitive magnetic microscopy with an optically pumped magnetometer

Optically pumped magnetometers (OPMs) based on lasers and alkali-metal vapor cells are currently the most sensitive non-cryogenic magnetic field sensors. Many applications in neuroscience and other fields require high-resolution, high-sensitivity magnetic microscopic measurements. In order to meet this demand we combined a cm-size spin-exchange relaxation-free (SERF) OPM and flux guides (FGs) to realize an ultra-sensitive FG-OPM magnetic microscope. The FGs serve to transmit the target magnetic flux to the OPM thus improving both the resolution and sensitivity to small magnetic objects. We investigated the performance of the FG-OPM device using experimental and numerical methods, and demonstrated that an optimized device can achieve a unique combination of high resolution (80 μm) and high sensitivity (8.1 pT/). Additionally, we also performed numerical calculations of the magnetic field distribution in the FGs to estimate the magnetic noise originating from the domain fluctuations in the material of the FGs. We anticipate many applications of the FG-OPM device such as the detection of micro-biological magnetic fields; the detection of magnetic nano-particles; and non-destructive testing. From our theoretical estimate, an FG-OPM could detect the magnetic field of a single neuron, which would be an important milestone in neuroscience.

47 OTHER INSTRUMENTATION↗