Search NASA⌕ Search

SEARCH · Search NASA

Results for “SERVER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Distributed metadata servers in a file system with separate metadata servers for file metadata and directory metadata

A file system is provided having a plurality of distributed metadata servers with separate metadata servers for file metadata and directory metadata. An exemplary distributed metadata storage system comprises a plurality of compute nodes, wherein at least one compute node comprises a file system client that generates a directory metadata request and/or a file metadata request; a plurality of directory metadata servers to serve directory metadata in response to a given directory metadata request; and a plurality of file metadata servers to serve file metadata in response to a given file metadata request. The plurality of directory metadata servers are distinct from the plurality of file metadata servers. The compute nodes optionally comprise an object client that requests object data from an object store system. The number of directory metadata servers and the number of file metadata servers are optionally determined independently to balance for different workloads, and can be dynamically readjusted for evolving workloads.

97 MATHEMATICS AND COMPUTING↗

Data decomposition of Monte Carlo particle transport simulations via tally servers

An algorithm for decomposing large tally data in Monte Carlo particle transport simulations is developed, analyzed, and implemented in a continuous-energy Monte Carlo code, OpenMC. The algorithm is based on a non-overlapping decomposition of compute nodes into tracking processors and tally servers. The former are used to simulate the movement of particles through the domain while the latter continuously receive and update tally data. A performance model for this approach is developed, suggesting that, for a range of parameters relevant to LWR analysis, the tally server algorithm should perform with minimal overhead on contemporary supercomputers. An implementation of the algorithm in OpenMC is then tested on the Intrepid and Titan supercomputers, supporting the key predictions of the model over a wide range of parameters. We thus conclude that the tally server algorithm is a successful approach to circumventing classical on-node memory constraints en route to unprecedentedly detailed Monte Carlo reactor simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LigSearch: a knowledge-based web server to identify likely ligands for a protein target

LigSearch is a web server for identifying ligands likely to bind to a given protein. Identifying which ligands might bind to a protein before crystallization trials could provide a significant saving in time and resources. LigSearch, a web server aimed at predicting ligands that might bind to and stabilize a given protein, has been developed. Using a protein sequence and/or structure, the system searches against a variety of databases, combining available knowledge, and provides a clustered and ranked output of possible ligands. LigSearch can be accessed at http://www.ebi.ac.uk/thornton-srv/databases/LigSearch.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

CORAL Server and CORAL Server Proxy: Scalable Access to Relational Databases from CORAL Applications

The CORAL software is widely used at CERN by the LHC experiments to access the data they store on relational databases, such as Oracle. Two new components have recently been added to implement a model involving a middle tier 'CORAL server' deployed close to the database and a tree of 'CORAL server proxies', providing data caching and multiplexing, deployed close to the client. A first implementation of the two new components, released in the summer 2009, is now deployed in the ATLAS online system to read the data needed by the High Level Trigger, allowing the configuration of a farm of several thousand processes. This paper reviews the architecture of the software, its development status and its usage in ATLAS.

99 GENERAL AND MISCELLANEOUS↗

HILIGT, Upper Limit Servers II - Implementing the Data Servers

The High-Energy Light curve Generator(HILIGT) is a new web-based tool which allows the user to generate long-term light curves of X-ray sources. It provides historical data and calculates upper limits from image data in real-time. HILIGT utilizes data from twelve satellites, both modern missions such as XMM-Newton and Swift, and earlier facilities such as ROSAT, EXOSAT, Einstein or Ariel V. Together, this enables the user to query 50 years of X-ray data and, for instance, study outburst behavior of transient sources. In this paper we focus on the individual back-end servers for each satellite, detailing the software layout, database design, catalog calls, and image footprints. We compile all relevant calibration information of these missions and provide an in-depth summary of the details of X-ray astronomical instrumentation and data.

Ole Konig↗

Trade Study: Storing NASA HDF5/netCDF-4 Data in the Amazon Cloud and Retrieving Data via Hyrax Server / THREDDS Data Server

As part of the overall effort to understand implications of migrating ESDIS data and services to the cloud we are testing several common OPeNDAP and HDF use cases against three architectures for general performance and cost characteristics. The architectures include retrieving entire files, retrieving datasets using HTTP range gets, and retrieving elements of datasets (chunks) with HTTP range gets. We will describe these architectures and discuss our approach to estimating cost.

HDF↗

Trade Study: Storing NASA HDF5/netCDF-4 Data in the Amazon Cloud and Retrieving Data Via Hyrax Server Data Server

This study explored three candidate architectures with different types of objects and access paths for serving NASA Earth Science HDF5 data via Hyrax running on Amazon Web Services (AWS). We studied the cost and performance for each architecture using several representative Use-Cases. The objectives of the study were: Conduct a trade study to identify one or more high performance integrated solutions for storing and retrieving NASA HDF5 and netCDF4 data in a cloud (web object store) environment. The target environment is Amazon Web Services (AWS) Simple Storage Service (S3). Conduct needed level of software development to properly evaluate solutions in the trade study and to obtain required benchmarking metrics for input into government decision of potential follow-on prototyping. Develop a cloud cost model for the preferred data storage solution (or solutions) that accounts for different granulation and aggregation schemes as well as cost and performance trades.We will describe the three architectures and the use cases along with performance results and recommendations for further work.

AWS cost↗

Characteristics and Energy Use of Volume Servers in the United States

Servers’ field energy use remains poorly understood, given heterogeneous computing loads, configurable hardware and software, and operation over a wide range of management practices. This paper explores various characteristics of 1- and 2-socket volume servers that affect energy consumption, and quantifies the difference in power demand between higher-performing SPEC and ENERGY STAR servers and our best understanding of a typical server operating today. We first establish general characteristics of the U.S. installed base of volume servers from existing IDC data and the literature, before presenting information on server hardware configurations from data collection events at a major online retail website. We then compare cumulative distribution functions of server idle power across three separate datasets and explain the differences between them via examination of the hardware characteristics to which power draw is most sensitive. We find that idle server power demand is significantly higher than ENERGY STAR benchmarks and the industry-released energy use documented in SPEC, and that SPEC server configurations—and likely the associated power-scaling trends—are atypical of volume servers. Next, we examine recent trends in server power draw among high-performing servers across their full load range to consider how representative these trends are of all volume servers before inputting weighted average idle power load values into a recently published model of national server energy use. Finally, we present results from two surveys of IT managers (n=216) and IT vendors (n=178) that illustrate the prevalence of more-efficient equipment and operational practices in server rooms and closets; these findings highlight opportunities to improve the energy efficiency of the U.S. server stock.

97 MATHEMATICS AND COMPUTING↗

Comparing datasets of volume servers to illuminate their energy use in data centers

As data centers proliferate, their energy intensity deserves close attention. Always-on operations and growing usage for cloud and other backend processes make servers the fundamental driver of data center energy use. Yet servers’ power draw under real-world conditions is poorly understood. This paper explores characteristics of volume servers that affect energy use, quantifying differences in power draw between higher-performing Standard Performance Evaluation Corporation (SPEC) and ENERGY STAR servers and that of a typical server. First, we establish general characteristics of the US installed base, before reporting hardware configurations from a major online retail website. We then compare idle power across three datasets (one unique to this paper) and explain their differences via the hardware characteristics to which power draw is most sensitive. We find idle server power demand to be significantly higher than benchmarks from ENERGY STAR and the industry-released SPEC database, and SPEC server configurations—and likely their power scaling—to be atypical of volume servers. Next, we examine power draw trends among high-performing servers across their load range to consider whether these trends are representative of volume servers, before inputting average idle power load values into a recent national server energy use model. Lastly, results from two surveys of IT professionals illustrate the incidence of more efficient equipment and operational practices in server rooms/closets. Future work should include server power field measurements in data centers of different sizes, accounting for variations in configurations and setting changes post-purchase, as well as investigating the linkage between time and server energy efficiency.

Fuchs, Heidi (ORCID:0000000300105411)↗

Energy Efficiency in Small Server Rooms: Field Surveys and Findings

Fifty-seven percent of US servers are housed in server closets, server rooms, and localized data centers, in what are commonly referred to as small server rooms, which comprise 99percent of all server spaces in the US. While many mid-tier and enterprise-class data centers are owned by large corporations that consider energy efficiency a goal to minimize business operating costs, small server rooms typically are not similarly motivated. They are characterized by decentralized ownership and management and come in many configurations, which creates a unique set of efficiency challenges. To develop energy efficiency strategies for these spaces, we surveyed 30 small server rooms across eight institutions, and selected four of them for detailed assessments. The four rooms had Power Usage Effectiveness (PUE) values ranging from 1.5 to 2.1. Energy saving opportunities ranged from no- to low-cost measures such as raising cooling set points and better airflow management, to more involved but cost-effective measures including server consolidation and virtualization, and dedicated cooling with economizers. We found that inefficiencies mainly resulted from organizational rather than technical issues. Because of the inherent space and resource limitations, the most effective measure is to operate servers through energy-efficient cloud-based services or well-managed larger data centers, rather than server rooms. Backup power requirement, and IT and cooling efficiency should be evaluated to minimize energy waste in the server space. Utility programs are instrumental in raising awareness and spreading technical knowledge on server operation, and the implementation of energy efficiency measures in small server rooms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing Server Energy Use and Efficiency Using Small Sample Sizes

This report documents a demonstration that compared the energy consumption and efficiency of a limited sample size of server-type IT equipment from different manufacturers by measuring power at the server power supply power cords. The results are specific to the equipment and methods used. However, it is hoped that those responsible for IT equipment selection can used the methods described to choose models that optimize energy use efficiency. The demonstration was conducted in a data center at Lawrence Berkeley National Laboratory in Berkeley, California. It was performed with five servers of similar mechanical and electronic specifications; three from Intel and one each from Dell and Supermicro. Server IT equipment is constructed using commodity components, server manufacturer-designed assemblies, and control systems. Server compute efficiency is constrained by the commodity component specifications and integration requirements. The design freedom, outside of the commodity component constraints, provides room for the manufacturer to offer a product with competitive efficiency that meets market needs at a compelling price. A goal of the demonstration was to compare and quantify the server efficiency for three different brands. The efficiency is defined as the average compute rate (computations per unit of time) divided by the average energy consumption rate. The research team used an industry standard benchmark software package to provide a repeatable software load to obtain the compute rate and provide a variety of power consumption levels. Energy use when the servers were in an idle state (not providing computing work) were also measured. At high server compute loads, all brands, using the same key components (processors and memory), had similar results; therefore, from these results, it could not be concluded that one brand is more efficient than the other brands. The test results show that the power consumption variability caused by the key components as a group is similar to all other components as a group. However, some differences were observed. The Supermicro server used 27 percent more power at idle compared to the other brands. The Intel server had a power supply control feature called cold redundancy, and the data suggest that cold redundancy can provide energy savings at low power levels. Test and evaluation methods that might be used by others having limited resources for IT equipment evaluation are explained in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Server-Based KML Code Generator Method for Level-of-Detail Traversal of Geospatial Data

Web-based geospatial client applications such as Google Earth and NASA World Wind must listen to data requests, access appropriate stored data, and compile a data response to the requesting client application. This process occurs repeatedly to support multiple client requests and application instances. Newer Web-based geospatial clients also provide user-interactive functionality that is dependent on fast and efficient server responses. With massively large datasets, server-client interaction can become severely impeded because the server must determine the best way to assemble data to meet the client applications request. In client applications such as Google Earth, the user interactively wanders through the data using visually guided panning and zooming actions. With these actions, the client application is continually issuing data requests to the server without knowledge of the server s data structure or extraction/assembly paradigm. A method for efficiently controlling the networked access of a Web-based geospatial browser to server-based datasets in particular, massively sized datasets has been developed. The method specifically uses the Keyhole Markup Language (KML), an Open Geospatial Consortium (OGS) standard used by Google Earth and other KML-compliant geospatial client applications. The innovation is based on establishing a dynamic cascading KML strategy that is initiated by a KML launch file provided by a data server host to a Google Earth or similar KMLcompliant geospatial client application user. Upon execution, the launch KML code issues a request for image data covering an initial geographic region. The server responds with the requested data along with subsequent dynamically generated KML code that directs the client application to make follow-on requests for higher level of detail (LOD) imagery to replace the initial imagery as the user navigates into the dataset. The approach provides an efficient data traversal path and mechanism that can be flexibly established for any dataset regardless of size or other characteristics. The method yields significant improvements in userinteractive geospatial client and data server interaction and associated network bandwidth requirements. The innovation uses a C- or PHP-code-like grammar that provides a high degree of processing flexibility. A set of language lexer and parser elements is provided that offers a complete language grammar for writing and executing language directives. A script is wrapped and passed to the geospatial data server by a client application as a component of a standard KML-compliant statement. The approach provides an efficient means for a geospatial client application to request server preprocessing of data prior to client delivery. Data is structured in a quadtree format. As the user zooms into the dataset, geographic regions are subdivided into four child regions. Conversely, as the user zooms out, four child regions collapse into a single, lower-LOD region. The approach provides an efficient data traversal path and mechanism that can be flexibly established for any dataset regardless of size or other characteristics.

Baxes, Gregory↗

Performance of a distributed superscalar storage server

The RS/6000 performed well in our test environment. The potential exists for the RS/6000 to act as a departmental server for a small number of users, rather than as a high speed archival server. Multiple UniTree Disk Server's utilizing one UniTree Disk Server's utilizing one UniTree Name Server could be developed that would allow for a cost effective archival system. Our performance tests were clearly limited by the network bandwidth. The performance gathered by the LibUnix testing shows that UniTree is capable of exceeding ethernet speeds on an RS/6000 Model 550. The performance of FTP might be significantly faster if asked to perform across a higher bandwidth network. The UniTree Name Server also showed signs of being a potential bottleneck. UniTree sites that would require a high ratio of file creations and deletions to reads and writes would run into this bottleneck. It is possible to improve the UniTree Name Server performance by bypassing the UniTree LibUnix Library altogether and communicating directly with the UniTree Name Server and optimizing creations. Although testing was performed in a less than ideal environment, hopefully the performance statistics stated in this paper will give end-users a realistic idea as to what performance they can expect in this type of setup.

Finestead, Arlan↗

Understanding Customer Dissatisfaction with Underutilized Distributed File Servers

An important trend in the design of storage subsystems is a move toward direct network attachment. Network-attached storage offers the opportunity to off-load distributed file system functionality from dedicated file server machines and execute many requests directly at the storage devices. For this strategy to lead to better performance, as perceived by users, the response time of distributed operations must improve. In this paper we analyze measurements of an Andrew file system (AFS) server that we recently upgraded in an effort to improve client performance in our laboratory. While the original server's overall utilization was only about 3%, we show how burst loads were sufficiently intense to lead to period of poor response time significant enough to trigger customer dissatisfaction. In particular, we show how, after adjusting for network load and traffic to non-project servers, 50% of the variation in client response time was explained by variation in server central processing unit (CPU) use. That is, clients saw long response times in large part because the server was often over-utilized when it was used at all. Using these measures, we see that off-loading file server work in a network-attached storage architecture has to potential to benefit user response time. Computational power in such a system scales directly with storage capacity, so the slowdown during burst period should be reduced.

Riedel, Erik↗

WMS Server 2.0

This software is a simple, yet flexible server of raster map products, compliant with the Open Geospatial Consortium (OGC) Web Map Service (WMS) 1.1.1 protocol. The server is a full implementation of the OGC WMS 1.1.1 as a fastCGI client and using Geospatial Data Abstraction Library (GDAL) for data access. The server can operate in a proxy mode, where all or part of the WMS requests are done on a back server. The server has explicit support for a colocated tiled WMS, including rapid response of black (no-data) requests. It generates JPEG and PNG images, including 16-bit PNG. The GDAL back-end support allows great flexibility on the data access. The server is a port to a Linux/GDAL platform from the original IRIX/IL platform. It is simpler to configure and use, and depending on the storage format used, it has better performance than other available implementations. The WMS server 2.0 is a high-performance WMS implementation due to the fastCGI architecture. The use of GDAL data back end allows for great flexibility. The configuration is relatively simple, based on a single XML file. It provides scaling and cropping, as well as blending of multiple layers based on layer transparency.

Plesea, Lucian↗

Asynchronous data change notification between database server and accelerator controls system

Database data change notification (DCN) is a commonly used feature. Not all database management systems (DBMS) provide an explicit DCN mechanism. Even for those DBMS's which support DCN (such as Oracle and MS SQL server), some server side and/or client side programming may be required to make the DCN system work. This makes the setup of DCN between database server and interested clients tedious and time consuming. In accelerator control systems, there are many well established software client/server architectures (such as CDEV, EPICS, and ADO) that can be used to implement data reflection servers that transfer data asynchronously to any client using the standard SET/GET API. This paper describes a method for using such a data reflection server to set up asynchronous DCN (ADCN) between a DBMS and clients. This method works well for all DBMS systems which provide database trigger functionality. Asynchronous data change notification (ADCN) between database server and clients can be realized by combining the use of a database trigger mechanism, which is supported by major DBMS systems, with server processes that use client/server software architectures that are familiar in the accelerator controls community (such as EPICS, CDEV or ADO). This approach makes the ADCN system easy to set up and integrate into an accelerator controls system. Several ADCN systems have been set up and used in the RHIC-AGS controls system.

43 PARTICLE ACCELERATORS↗

Liquid-Cooled Server Technology that Dramatically Reduces Electricity in Building-Connected Data Centers and Enables 95% Waste Heat Reuse

Today data centers in the U.S consume about 70 TWh of electricity annually. What if there was an easy way to reduce this electricity use by up to 35%? Even better, what if data centers were located in ordinary buildings without the need for expensive air conditioning and air handing systems? Better still, what if the heat energy produced by the data center's servers could be easily recovered and reused for building heating? This presentation will provide an overview of a unique and innovative form of liquid immersion cooling for data center servers developed by LiquidCool Solutions that can be easily deployed to achieve the benefits described above. As validation of the benefits, the presentation will describe testing of a small-scale version of this immersion cooling system conducted at the National Renewable Energy Laboratory. Testing demonstrated that the system was able to recover 90% to 95% of server heat energy at a temperature high enough for use by conventional building heating systems while eliminating internal server fans and using just 1% of the server power to circulate cooling fluid through the system. The concluding section of the presentation will focus on development of a roadmap for scaling-up and commercializing this innovative cooling technology. This will include proposals for how specific commercial building types could make effective use of this technology to recover and reuse server waste heat and a strategy for overcoming barriers to adoption of such a new and innovative technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗