Search NASA⌕ Search

SEARCH · Search NASA

Results for “SHUNT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Measurement of band offsets and shunt resistance in CdTe solar cells through temperature and intensity dependence of open circuit voltage and photoluminescence

Band offsets at the back contact and front window layer in CdTe-based solar cells affect photovoltaic performance and challenge standard characterization methods. By analyzing the temperature and excitation dependence of both open circuit voltage and absolute photoluminescence intensity, we show that the effects band offsets can be separated from the effects of recombination and shunting. Solar cells were grown with MgZnO window layers and compared to cells with CdS window layers containing varying amounts of oxygen. It was demonstrated that band alignment rather than reduced recombination velocity is the reason for the success of MgZnO as a front interface contact. An assortment of thin back contact interlayers were also deposited, and a PbTe interlayer showed some promise as an Ohmic contact to the CdTe, though it appears to induce a photoconductive shunt. Finally, we show that the shunting resistance given by a standard current-voltage curve technique generally does not represent a physically meaningful quantity unless it is well below one kiloOhm square cm.

14 SOLAR ENERGY↗

High-Flow Arterio-Hepatic Venous Shunt in Hepatocellular Carcinoma: Use of Multi-Electrode Radiofrequency for Shunt Obliteration

Intra-tumoral arterio-hepatic venous shunting (AHVS) poses an impediment to transarterial chemoembolization of liver tumors. Not only does it present a potential hazard for systemic shunting and embolization, but also the altered flow dynamics may also result in poor delivery of drug/embolics to the target tumor bed. Current available techniques to overcome AVHS include arterial embolization (particles, coils, glue, etc.) or temporary venous occlusion using balloons. We hereby illustrate the use of radiofrequency ablation to obliterate a complex AHVS consisting of a varix-like venous aneurysm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temporary arterial shunts to maintain limb perfusion after arterial injury: an animal study

BACKGROUND: Temporary shunt placement can quickly restore perfusion after extremity arterial injury. This study examined the adequacy of limb blood flow with shunt use, non-heparin-bonded shunt patency over prolonged periods, and the safety of this technique. METHODS: Common iliac arteries were divided and 4.0-mm Silastic Sundt shunts placed in 16 anesthetized pigs. Eight (group I) had shunts placed immediately; eight others (group II) were shunted after an hour of limb ischemia and hemorrhagic shock. Physiologic parameters and femoral artery blood flow in both hindlimbs were continuously monitored. Limb lactic acid generation, oxygen utilization, and hematologic and metabolic effects were serially evaluated for 24 hours. RESULTS: Shunts remained patent in 13 of 16 pigs. Shunts thrombosed in two group I animals because of technical errors, but functioned well after thrombectomy and repositioning. Patency could not be maintained in one animal that died from shock. Flow in group I shunted limbs was 57 (+/-11 SD) % of control. For group II animals in shock, shunted limb flow initially averaged 46 +/- 15% of control, but 4 hours after shunt placement, the mean limb blood flow was the same as in group I. Increased oxygen extraction compensated for the lower flow. Lactic acid production was not increased in comparison to control limbs. CONCLUSION: Shunts provided adequate flow in this model of extremity trauma. Correctly placed shunts stayed patent for 24 hours, without anticoagulation, if shunt placement followed resuscitation.

Hindlimb/blood supply/injuries↗

Investigating PID shunting in polycrystalline silicon modules via multiscale, multitechnique characterization

We investigated the potential-induced degradation (PID) shunting mechanism in multicrystalline-silicon photovoltaic modules by using a multiscale, multitechnique characterization approach. Both field-stressed modules and laboratory-stressed mini modules were studied. We used photoluminescence, electroluminescence, and dark lock-in thermography imaging to identify degraded areas at the module scale. Small samples were then removed from degraded areas, laser marked, and imaged by scanning electron microscopy. We used simultaneous electron-beam induced current imaging and focused ion beam milling to mark around PID shunts for chemical analysis by time-of-flight secondary-ion mass spectrometry or to isolate individual shunt defects for transmission electron microscopy and atom-probe tomography analysis. By spanning a range of 10 orders of magnitude in size, this approach enabled us to investigate the root-cause mechanisms for PID shunting. We observed a direct correlation between recombination active shunts and sodium content. The sodium content in shunted areas peaks at the SiNX/Si interface and is consistently observed at a concentration of 0.1% to 2% in shunted areas. Analysis of samples subjected to PID recovery, either activated by electron beam or thermal effects only, reveals that recovery of isolated shunts correlates with diffusion of sodium out of the structural defects to the silicon surface. We observed the role of oxygen and chlorine in PID shunting and found that those species - although sometimes present in structural defects where PID shunting was observed - do not play a consistent role in PID shunting.

14 SOLAR ENERGY↗

Short-Term Oral Sorafenib for Therapy of Intratumoral Shunts of Hepatocellular Carcinoma to Enable Intraarterial Treatment

Introduction: Significant intratumoral shunts between tumor-supplying arteries and portal or liver veins are a contraindication for transarterial therapy of HCC because interventional treatment of these shunts is frequently insufficient. Sorafenib has anti-angiogenic effects and is indicated for palliative treatment of patients with HCC. Here, we report our experience with the use of sorafenib for the closure of intratumoral shunts in patients scheduled for transarterial therapy of HCC. Materials and Methods: Three patients with HCC, aged 65, 82 and 79 years, exhibited a significant intratumoral shunting from tumor artery to portal (n = 1) or liver veins (n = 2). In all cases, intratumoral shunting had already been suspected based on pre-interventional CT angiography, and DSA confirmed the shunt. Oral sorafenib (800 mg/day) was administered for at least four weeks, only and specifically to occlude the shunt. Hereafter, patients were re-evaluated by CT and DSA. Results: All patients tolerated the full prescribed dose for at least 4 weeks. In one case, therapy was prolonged with an adapted dose (400 mg/day) due to sorafenib-related hand–foot syndrome. After sorafenib treatment, CT and DSA confirmed a complete closure of intratumoral shunts for all patients. No tumor progression was observed. All three patients hereafter underwent successful transarterial treatment by TACE (n = 2) or TARE (n = 1) without complications. Progression-free survival according to mRECIST was 501, 397 and 599 days, respectively. Conclusion: Even short-term oral sorafenib seems to effectively close intratumoral shunts in patients with HCC and thus might enable transarterial treatment of these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Piezoelectric Shunt Vibration Damping of F-15 Panel under High Acoustic Excitation

At last year's SPIE symposium, we reported results of an experiment on structural vibration damping of an F-15 underbelly panel using piezoelectric shunting with five bonded PZT transducers. The panel vibration was induced with an acoustic speaker at an overall sound pressure level (OASPL) of about 90 dB. Amplitude reductions of 13.45 and 10.72 dB were achieved for the first and second modes, respectively, using single- and multiple-mode shunting. It is the purpose of this investigation to extend the passive piezoelectric shunt-damping technique to control structural vibration induced at higher acoustic excitation levels, and to examine the controllability and survivability of the bonded PZT transducers at these high levels. The shunting experiment was performed with the Thermal Acoustic Fatigue Apparatus (TAFA) at the NASA Langley Research Center using the same F-15 underbelly panel. The TAFA is a progressive wave tube facility. The panel was mounted in one wall of the TAFA test section using a specially designed mounting fixture such that the panel was subjected to grazing-incidence acoustic excitation. Five PZT transducers were used with two shunt circuits designed to control the first and second modes of the structure between 200 and 400 Hz. We first determined the values of the shunt inductance and resistance at an OASPL of 130 dB. These values were maintained while we gradually increased the OASPL from 130 to 154 dB in 6-dB steps. During each increment, the frequency response function between accelerometers on the panel and the acoustic excitation measured by microphones, before and after shunting, were recorded. Good response reduction was observed up to the 148dB level. The experiment was stopped at 154 dB due to wire breakage from vibration at a transducer wire joint. The PZT transducers, however, were still bonded well on the panel and survived at this high dB level. We also observed shifting of the frequency peaks toward lower frequency when the OASPL was increased. Detailed experimental results will be presented.

Wu, Shu-Yau↗

Patent Foramen Ovale: Association between the Degree of Shunt by Contrast Transesophageal Echocardiography and the Risk of Future Ischemic Neurologic Events

This study investigated whether there is an association between the degree of interatrial shunting across a patent foramen ovale, as determined by saline contrast transesophageal echocardiography, and the risk of subsequent systemic embolic events, including stroke. Thirty-four patients found to have patent foramen ovale during transesophageal echocardiography were divided into two groups on the basis of the maximum number of microbubbles in the left heart in any single frame after intravenous saline contrast injection: group 1 (n = 16) with a "large" degree of shunt (220 microbubbles) and group 2 (n = 18) with a "small" degree of shunt (23 but <20 microbubbles). Patients were followed up over a mean period of 21 months for subsequent systemic embolic events, including transient ischemic attack and stroke. Five (31%) of the patients with large shunts had subsequent ischemic neurologic events, whereas none of the patients with small shunts had embolic events (p= 0.03). These events occurred in spite of antiplatelet or anticoagulant therapy. We conclude that patients with a large degree of shunt across a patent foramen ovale, as determined by contrast transesophageal echocardiography, are at a significantly higher risk for subsequent adverse neurologic events compared with patients with a small degree of shunt.

Stone, David A.↗

Passively Shunted Piezoelectric Damping of Centrifugally-Loaded Plates

Researchers at NASA Glenn Research Center have been investigating shunted piezoelectric circuits as potential damping treatments for turbomachinery rotor blades. This effort seeks to determine the effects of centrifugal loading on passively-shunted piezoelectric - damped plates. Passive shunt circuit parameters are optimized for the plate's third bending mode. Tests are performed both non-spinning and in the Dynamic Spin Facility to verify the analysis, and to determine the effectiveness of the damping under centrifugal loading. Results show that a resistive shunt circuit will reduce resonant vibration for this configuration. However, a tuned shunt circuit will be required to achieve the desired damping level. The analysis and testing address several issues with passive shunt circuit implementation in a rotating system, including piezoelectric material integrity under centrifugal loading, shunt circuit implementation, and tip mode damping.

Duffy, Kirsten P.↗

Sodium accumulation at potential-induced degradation shunted areas in polycrystalline silicon modules

Here, we investigated potential-induced degradation (PID) in silicon mini-modules that were subjected to accelerated stressing to induce PID conditions. Shunted areas on the cells were identified with photoluminescence and dark lock-in thermography (DLIT) imaging. The identical shunted areas were then analyzed via time-of-flight secondary-ion mass spectrometry (TOFSIMS) imaging, 3-D tomography, and high-resolution transmission electron microscopy. The TOF-SIMS imaging indicates a high concentration of sodium in the shunted areas, and 3-D tomography reveals that the sodium extends more than 2 um from the surface below shunted regions. Transmission electron microscopy investigation reveals that a stacking fault is present at an area identified as shunted by DLIT imaging. After the removal of surface sodium, tomography reveals persistent sodium present around the junction depth of 300 nm and a drastic difference in sodium content at the junction when comparing shunted and nonshunted regions.

14 SOLAR ENERGY↗

Shunted Piezoelectric Vibration Damping Analysis Including Centrifugal Loading Effects

Excessive vibration of turbomachinery blades causes high cycle fatigue problems which require damping treatments to mitigate vibration levels. One method is the use of piezoelectric materials as passive or active dampers. Based on the technical challenges and requirements learned from previous turbomachinery rotor blades research, an effort has been made to investigate the effectiveness of a shunted piezoelectric for the turbomachinery rotor blades vibration control, specifically for a condition with centrifugal rotation. While ample research has been performed on the use of a piezoelectric material with electric circuits to attempt to control the structural vibration damping, very little study has been done regarding rotational effects. The present study attempts to fill this void. Specifically, the objectives of this study are: (a) to create and analyze finite element models for harmonic forced response vibration analysis coupled with shunted piezoelectric circuits for engine blade operational conditions, (b) to validate the experimental test approaches with numerical results and vice versa, and (c) to establish a numerical modeling capability for vibration control using shunted piezoelectric circuits under rotation. Study has focused on a resonant damping control using shunted piezoelectric patches on plate specimens. Tests and analyses were performed for both non-spinning and spinning conditions. The finite element (FE) shunted piezoelectric circuit damping simulations were performed using the ANSYS Multiphysics code for the resistive and inductive circuit piezoelectric simulations of both conditions. The FE results showed a good correlation with experimental test results. Tests and analyses of shunted piezoelectric damping control, demonstrating with plate specimens, show a great potential to reduce blade vibrations under centrifugal loading.

Min, James B.↗

The Relationship between Shunt Currents and Edge Corrosion in Flow Batteries

Shunt currents occur in electrochemical reactors like flow batteries, electrolyzers, and fuel cells where many bipolar cells that are connected in series electrically contact a mobile electrolyte through one or more common fluid distribution manifolds. Shunt currents reduce energy efficiency, and can cause unwanted side reactions including corrosion and gas generation. Equivalent-circuit models have been widely used to examine shunt currents in multi-cell electrochemical reactors. However, a detailed investigation of the interesting electrochemical processes occurring at the edges of the active areas has not been presented. In this work, the generation of shunt currents and their tendency to drive corrosion at the edges of positive electrodes in the most positive cells in a reactor stack are investigated with a comprehensive numerical model. An analytical model based on the penetration of current into a semi-infinite electrode, that can be used in conjunction with traditional equivalent-circuit models to assess the tendency for shunt currents to drive corrosion, is developed and compared to the numerical model. The models provided here can be used to set requirements on maximum allowable port currents in order to achieve a particular durability goal.

25 ENERGY STORAGE↗

Experimental Comparison of Piezoelectric and Magnetostrictive Shunt Dampers

A novel mechanism called the vibration ring is being developed to enable energy conversion elements to be incorporated into the driveline of a helicopter or other rotating machines. Unwanted vibration is transduced into electrical energy, which provides a damping effect on the driveline. The generated electrical energy may also be used to power other devices (e.g., health monitoring sensors). PZT (piezoceramic) and PMN-30PT (single crystal) stacks, as well as a Tb_0.3 Dy_0.7 Fe_1.92 (Terfenol-D) rod with a bias magnet array and a pickup coil, were tested as alternative energy conversion elements to use within the vibration ring. They were tuned for broadband damping using shunt resistors, and dynamic compression testing was conducted in a high-speed load frame. Energy conversion was experimentally optimized at 750Hz by tuning the applied bias stress and resistance values. Dynamic testing was conducted up to 1000Hz to determine the effective compressive modulus, shunt loss factor, internal loss factor, and total loss factor. Some of the trends of modulus and internal loss factor versus frequency were unexplained. The single crystal device exhibited the greatest shunt loss factor whereas the Terfenol-D device had the highest internal and total loss factors. Simulations revealed that internal losses in the Terfenol-D device were elevated by eddy current effects, and an improved magnetic circuit could enhance its shunt damping capabilities. Alternatively, the Terfenol-D device may be simplified to utilize only the eddy current dissipation mechanism (no pickup coil or shunt) to create broadband damping.

energy conversion↗

Experimental Comparison of Piezoelectric and Magnetostrictive Shunt Dampers

A novel mechanism called the vibration ring is being developed to enable energy conversion elements to be incorporated into the driveline of a helicopter or other rotating machines. Unwanted vibration is transduced into electrical energy, which provides a damping effect on the driveline. The generated electrical energy may also be used to power other devices (e.g., health monitoring sensors). PZT (piezoceramic) and PMN-30%PT (single crystal) stacks, as well as a Tb_0.3 Dy_0.7 Fe_1.92 (Terfenol-D) rod with a bias magnet array and a pickup coil, were tested as alternative energy conversion elements to use within the vibration ring. They were tuned for broadband damping using shunt resistors, and dynamic compression testing was conducted in a high-speed load frame. Energy conversion was experimentally optimized at 750Hz by tuning the applied bias stress and resistance values. Dynamic testing was conducted up to 1000Hz to determine the effective compressive modulus, shunt loss factor, internal loss factor, and total loss factor. Some of the trends of modulus and internal loss factor versus frequency were unexplained. The single crystal device exhibited the greatest shunt loss factor whereas the Terfenol-D device had the highest internal and total loss factors. Simulations revealed that internal losses in the Terfenol-D device were elevated by eddy current effects, and an improved magnetic circuit could enhance its shunt damping capabilities. Alternatively, the Terfenol-D device may be simplified to utilize only the eddy current dissipation mechanism (no pickup coil or shunt) to create broadband damping.

piezoelectric↗

An Approach to Endovascular and Percutaneous Management of Transjugular Intrahepatic Portosystemic Shunt (TIPS) Dysfunction: A Pictorial Essay and Clinical Practice Algorithm

Transjugular intrahepatic portosystemic shunts (TIPS) have evolved as an effective and durable nonsurgical option in the treatment of portal hypertension (PH). It has been shown to improve survival in decompensated cirrhosis and may also serve as a bridge to liver transplantation. In spite of the technical improvements in the procedure, problems occur with the shunt which jeopardizes effective treatment of the PH. Appropriate management is vital to ensure the longevity of the conduit. Shunt revision techniques include endovascular revision techniques and new shunt creation or, in the appropriate patients, alternative/rescue therapies. The ability of interventional radiologists to restore adequate TIPS function has enormous implications for quality of life with palliation, morbidity/mortality related to variceal bleeding and survival if transplant candidates can live long enough to receive a new liver. As such, it is imperative that these treatment strategies are understood and employed when these patients are encountered. In this review, the restoration of appropriate shunt function using various techniques will be discussed as they apply to a variety of clinical scenarios, based on literature. In addition, illustrative case examples highlighting our experience at an academic tertiary medical center will be included. It is the intent to have this document serve as a concise and informative reference to be used by those who may encounter patients with suboptimal functioning TIPS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of C-Arm Cone Beam CT During Hepatic Radioembolization: Protocol Optimization for Extrahepatic Shunting and Parenchymal Enhancement

PurposeTo optimize a C-arm computed tomography (CT) protocol for radioembolization (RE), specifically for extrahepatic shunting and parenchymal enhancement.Materials and MethodsA prospective development study was performed per IDEAL recommendations. A literature-based protocol was applied in patients with unresectable and chemorefractory liver malignancies undergoing an angiography before radioembolization. Contrast and scan settings were adjusted stepwise and repeatedly reviewed in a consensus meeting. Afterwards, two independent raters analyzed all scans. A third rater evaluated the SPECT/CT scans as a reference standard for extrahepatic shunting and lack of target segment perfusion.ResultsFifty scans were obtained in 29 procedures. The first protocol, using a 6 s delay and 10 s scan, showed insufficient parenchymal enhancement. In the second protocol, the delay was determined by timing parenchymal enhancement on DSA power injection (median 8 s, range 4–10 s): enhancement improved, but breathing artifacts increased (from 0 to 27 %). Since the third protocol with a 5 s scan decremented subjective image quality, the second protocol was deemed optimal. Median CNR (range) was 1.7 (0.6–3.2), 2.2 (−1.4–4.0), and 2.1 (−0.3–3.0) for protocol 1, 2, and 3 (p = 0.80). Delineation of perfused segments was possible in 57, 73, and 44 % of scans (p = 0.13). In all C-arm CTs combined, the negative predictive value was 95 % for extrahepatic shunting and 83 % for lack of target segment perfusion.ConclusionAn optimized C-arm CT protocol was developed that can be used to detect extrahepatic shunts and non-perfusion of target segments during RE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Balloon-Assisted Chemoembolization Using a Micro-Balloon Catheter Alongside a Microcatheter for a Hepatocellular Carcinoma with a Prominent Arterioportal Shunt: A Case Report

Although transcatheter arterial chemoembolization is one of the established treatments for hepatocellular carcinoma (HCC), it is difficult to treat HCCs with prominent arterioportal (AP) shunts because anticancer drugs and embolic materials migrate into the non-tumorous liver through the AP shunts and may cause liver infarction. We developed a novel method of balloon-assisted chemoembolization using a micro-balloon catheter alongside a microcatheter simultaneously inserted through a single 4.5-Fr guiding sheath, comprising proximal chemoembolization with distal arterial balloon occlusion. We applied this method to treat an HCC with a prominent distal AP shunt induced by previous proton beam therapy and achieved successful chemoembolization without non-tumorous liver infarction under temporal balloon occlusion of a distal AP shunt.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RFB Side Effects - Shunt Currents

The various models related to fluid flow, electrochemistry and shunt current, and their interactions are reviewed, and gaps identified in the development of flow battery holistic models. In a flow battery stack, the cells are electrically connected through the manifolds via the electrolyte. This results in shunt current through the electrolyte, which is a source of loss in the battery stack. This issue is examined in depth with a mathematical method of calculating shunt current distribution, the associated losses, and strategies to mitigate shunt current losses, along with the trade-offs.

Crawford, Aladsair J.↗