Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL CONDITIONERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Universal dc signal conditioner

Signal conditioner was designed which can condition dc signals over range of + or - volts. It is lighter, has lower initial and maintenance costs, and higher reliability than conventional discrete circuit designs. System incorporates linear integrated circuits in conjunction with hybrid, thin film circuit technology to achieve high degree of circuit miniaturization.

Bradanini, P. A.↗

Advanced Signal Conditioners for Data-Acquisition Systems

Signal conditioners embodying advanced concepts in analog and digital electronic circuitry and software have been developed for use in data-acquisition systems that are required to be compact and lightweight, to utilize electric energy efficiently, and to operate with high reliability, high accuracy, and high power efficiency, without intervention by human technicians. These signal conditioners were originally intended for use aboard spacecraft. There are also numerous potential terrestrial uses - especially in the fields of aeronautics and medicine, wherein it is necessary to monitor critical functions. Going beyond the usual analog and digital signal-processing functions of prior signal conditioners, the new signal conditioner performs the following additional functions: It continuously diagnoses its own electronic circuitry, so that it can detect failures and repair itself (as described below) within seconds. It continuously calibrates itself on the basis of a highly accurate and stable voltage reference, so that it can continue to generate accurate measurement data, even under extreme environmental conditions. It repairs itself in the sense that it contains a micro-controller that reroutes signals among redundant components as needed to maintain the ability to perform accurate and stable measurements. It detects deterioration of components, predicts future failures, and/or detects imminent failures by means of a real-time analysis in which, among other things, data on its present state are continuously compared with locally stored historical data. It minimizes unnecessary consumption of electric energy. The design architecture divides the signal conditioner into three main sections: an analog signal section, a digital module, and a power-management section. The design of the analog signal section does not follow the traditional approach of ensuring reliability through total redundancy of hardware: Instead, following an approach called spare parts tool box, the reliability of each component is assessed in terms of such considerations as risks of damage, mean times between failures, and the effects of certain failures on the performance of the signal conditioner as a whole system. Then, fewer or more spares are assigned for each affected component, pursuant to the results of this analysis, in order to obtain the required degree of reliability of the signal conditioner as a whole system. The digital module comprises one or more processors and field-programmable gate arrays, the number of each depending on the results of the aforementioned analysis. The digital module provides redundant control, monitoring, and processing of several analog signals. It is designed to minimize unnecessary consumption of electric energy, including, when possible, going into a low-power "sleep" mode that is implemented in firmware. The digital module communicates with external equipment via a personal-computer serial port. The digital module monitors the "health" of the rest of the signal conditioner by processing defined measurements and/or trends. It automatically makes adjustments to respond to channel failures, compensate for effects of temperature, and maintain calibration.

Lucena, Angel↗

Physiological Signal Conditioner

Sensors 2000! is developing a Physiological Signal Conditioner (PSC) for monitoring of astronauts in the ISS Human Research Facility. The PSC is battery powered and worn by the crew. The Engineering Development Unit (PSC EDU) and the form-and-fit PSC Tooling Model will be displayed along with associated graphics and text explanations. Results of a recent advanced PSC-2 feasibility study will be presented. The presentation will stimulate discussion of the functional capabilities of a wireless, crew worn Physiological Signal Conditioner. Application of advanced technology to meet the conflicting demands of size, power, and functional capability will be of interest.

Friedericks, C.↗

Input signal conditioner for the multimegasymbol telemetry system feasibility model

The input signal conditioner portion of the multimegasymbol telemetry demodulator and detector feasibility model is described. The input signal conditioner accepts the 55 MHz wideband IF signal of a Block 4 Deep Space Network receiver and provides selectable bandpass filtering, total power automatic gain control, and frequency translation providing inphase and quadrature outputs at baseband.

Stevens, G. L.↗

The application of the analog signal to discrete time interval converter to the signal conditioner power supplies

The Analog Signal to Discrete Time Interval Converter microminiaturized module was utilized to control the signal conditioner power supplies. The multi-loop control provides outstanding static and dynamic performance characteristics, exceeding those generally associated with single-loop regulators. Eight converter boards, each containing three independent dc to dc converter, were built, tested, and delivered.

Schoenfeld, A. D.↗

Design of a signal conditioner for the Fermilab Magnet Test Facility

This thesis describes the design of a remotely-programmable signal conditioner for the harmonic measurement of accelerator magnets. A 10-channel signal conditioning circuit featuring bucking capabilities was designed from scratch and implemented to the level of the printed circuit board layout. Other system components were chosen from those available on the market. Software design was started with the definition of routine procedures. This thesis is part of an upgrade project for replacing obsolescent automated test equipment belonging to the Fermilab Magnet Test Facility. The design started with a given set of requirements. Using a top-down approach, all the circuits were designed and their expected performances were theoretically predicted and simulated. A limited prototyping phase followed. The printed circuit boards were laid out and routed using a CAD software and focusing the design on maximum electromagnetic interference immunity. An embedded board was selected for controlling and interfacing the signal conditioning circuitry with the instrumentation network. Basic low level routines for hardware access were defined. This work covered the entire design process of the signal conditioner, resulting in a project ready for manufacturing. The expected performances are in line with the requirements and, in the cases where this was not possible, approval of trade-offs was sought and received from the end users. Part I deals with the global structure of the signal conditioner and the subdivision in functional macro-blocks. Part II treats the hardware design phase in detail, covering the analog and digital circuits, the printed circuit layouts, the embedded controller and the power supply selection. Part III deals with the basic hardware-related routines to be implemented in the final software.

43 PARTICLE ACCELERATORS↗

Adaptive analog video signal conditioner

This paper presents an adaptive analog video signal conditioner. This system supplements conventional irises and automatic gain controls to condition video signals for digitizing with a uniform analog-to-digital converter. Employing two degree of freedom, this circuit adjusts an analog gain and analog offset to increase the average information content of digitized images as defined by an entropy measure. The globally near-optimized implementation tracks smoothly to adapt to changing scene conditions.

Jeong, Cheol-Ho↗

Hybrid respiration-signal conditioner

Hybrid impedance-pneumograph and respiration-rate signal conditioner element of hand-held vital signs monitor measures changes in impedance of chest during breathing cycle and generates analog respiration signal as output along with synchronous square wave that can be monitored by breath-rate processor.

Rinard, G. A.↗

B and F Signal Conditioner Checkout Unit

ATK Thiokol Propulsion, Test Services uses B&F Signal Conditioning units to provide excitation power and shunt calibration information to the data recording systems. Gage measurements such as force, temperature, pressure, strain, etc. are recorded using this equipment. Approximately 2500 reusable instrumentation B&F Signal Conditioning units were purchased over an interval from 1978 to 1988 at a cost of around $1000 each. Through use and over time, the relay contacts on the signal conditioning mode cards have become corroded, resulting in excessive contact resistance. This causes inaccurate and inconsistent calibration data and could jeopardize the test results. These signal conditioning cards are needed for product testing for an estimated five more years, therefore, it is necessary to develop a solution to isolate the malfunctioning units for repair. The current screening method requires Test Area technicians to check cards manually, however the connections and measurements required for this process are inefficient and time consuming. To resolve this problem, funding was approved to design and build two B&F Signal Conditioner Checkout Units. Each unit will allow technicians to test relay contact resistance on signal conditioning mode cards before they are installed for data collection procedures. This tool will allow Test Area to resolve calibration accuracy problems and extend the life of the data acquisition equipment, as well as save troubleshooting time for the technicians.

Magleby, Alyssa↗

120 MB/S and 240 MB/S bit synchronizer-signal conditioners for NASA high data rate applications

Two bit synchronizer-signal conditioners (BSSC) developed for NASA high data rate applications such as earth resources monitoring are described. One BSSC is centered at 120 MB/s and the other at 240 Mb/s. These subsystems are featured out of the total hardware developed because the BSSC is such a key subsystem in determining overall system statistical performance. These units represent an evolution of high data rate BSSC's available at low data rates. Numerous inputs/outputs, control functions, indicators, plus the ability to minimize the effects of various signal perturbations are provided. Examples of allowed perturbations are input level variations, bit rate variance static and dynamic, baseline, transition density, bandlimiting, etc., as well as noise. Emphasis in the past has been primarily concerned only with noise.

Gray, J. S.↗

Investigation into the common mode rejection ratio of the physiological signal conditioner circuit

The common mode rejection ratio (CMRR) of the single operational amplifier (op amp) differential amplifier and of the three operational amplifier differential amplifier was investigated. The three op amp differential amplifier circuit is used in the signal conditioner circuit which amplifies signals such as the electromyograph or electrocardiogram. The investigation confirmed via SPICE modeling what has been observed by others in the recent literature that the CMRR for the circuit can be maximized without precision resistor values or precisely matched op amps. This can be done if one resistor in the final stage can be adjusted either by a potentiometer or by laser trimming in the case of hybrid circuit fabrication.

Obrien, Edward M.↗

Signal conditioner test set

Compact, light-weight, solid-state test set can be used to check signal conditioning modules while they are installed in system. Test sets may also be used to cycle ground computer, if it is suspected of malfunctioning, rather than using signal conditioners.

Houck, W. H.↗

An experimental investigation of compressor stall using an on-line distortion indicator and signal conditioner

The relation of the steady-state and dynamic distortions and the stall margin of a J85-13 turbojet engine was investigated. A distortion indicator capable of computing two distortion indices was used. A special purpose signal conditioner was also used as an interface between transducer signals and distortion indicator. A good correlation of steady-state distortion and stall margin was established. The prediction of stall by using the indices as instantaneous distortion indicators was not successful. A sensitivity factor that related the loss of stall margin to the turbulence level was found.

Costakis, W. G.↗

A range expanding signal conditioner

Telemetry system modifications to improve signal resolution are described. Process uses zero suppression technique which consists of subtracting known voltage from input and amplifying remainder. Schematic diagram of circuit is provided and details of operation are presented.

Russell, W. A.↗

Signal conditioner for potentiometer type transducers

Low cost method is described for signal conditioning of pot-type transducers utilizing printed circuitry. Conditioner fits into standard rack, accommodates 56 channels, and can be operated by one attendant.

Armentrout, E. C.↗

Signal conditioner test set

A system was developed for testing components contained in a signal conditioning module with a transistor and capacitor included in a circuit. The system includes a housing with a socket into which the module to be tested is plugged. A test switch is provided for selectively connecting a variable load to either a transistor or capacitor in the circuit for testing the operation. A signal generating circuit is provided for generating signals for use in testing the components of the module.

Houck, W. H.↗