Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL CONDITIONERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Design of a signal conditioner for the Fermilab Magnet Test Facility

This thesis describes the design of a remotely-programmable signal conditioner for the harmonic measurement of accelerator magnets. A 10-channel signal conditioning circuit featuring bucking capabilities was designed from scratch and implemented to the level of the printed circuit board layout. Other system components were chosen from those available on the market. Software design was started with the definition of routine procedures. This thesis is part of an upgrade project for replacing obsolescent automated test equipment belonging to the Fermilab Magnet Test Facility. The design started with a given set of requirements. Using a top-down approach, all the circuits were designed and their expected performances were theoretically predicted and simulated. A limited prototyping phase followed. The printed circuit boards were laid out and routed using a CAD software and focusing the design on maximum electromagnetic interference immunity. An embedded board was selected for controlling and interfacing the signal conditioning circuitry with the instrumentation network. Basic low level routines for hardware access were defined. This work covered the entire design process of the signal conditioner, resulting in a project ready for manufacturing. The expected performances are in line with the requirements and, in the cases where this was not possible, approval of trade-offs was sought and received from the end users. Part I deals with the global structure of the signal conditioner and the subdivision in functional macro-blocks. Part II treats the hardware design phase in detail, covering the analog and digital circuits, the printed circuit layouts, the embedded controller and the power supply selection. Part III deals with the basic hardware-related routines to be implemented in the final software.

43 PARTICLE ACCELERATORS↗

NBSR reactor control room upgrade - 215

The maintenance and modernization of the National Institute of Standards and Technology (NIST) Center for Neutron Research (NCNR) reactor, known as the NBSR, is an ongoing process to endure until the eventual decommissioning of the reactor. As part of the renovation effort, the reactor control system is to be upgraded. Following some initial outsourcing efforts, the NBSR reactor control system upgrade has been restructured to be implemented by in-house means. The beginning stage of the upgrade involved the development of a simulator environment based on a PC system and digitization of the majority of nuclear reactor monitoring data. The NBSR reactor surveillance data consists of approximately thirteen hundred input/output points, including analog/digital sensor signals, signal conditioners, and relay logic. The aim of the current phase is to implement a new reactor data acquisition and display system (RDS) and lay out the infrastructure for the upgrade of the reactor control system (RCS). Key design criteria are to implement a reliable, redundant, diverse, modular and candid system where any complex digital manipulations are taken outside of the control room. Basically, the data analytics and custom codes are separated from reactor operation control and decision making logic. Furthermore, the new RDS is designed such that it could be maintained internally by NCNR personnel. The RDS is unique in design and modularity, minimizing custom codes and testing, making it ideal for research reactors. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design and Instrumentation of a Measurement and Calibration System for an Acoustic Telemetry System

The Juvenile Salmon Acoustic Telemetry System (JSATS) is an active sensing technology developed by Portland District, the U.S. Army Corps of Engineers for detecting and tracking small fish. It is used at hydroelectric projects and in the laboratory for evaluating behavior and survival of juvenile salmonids migrating through the Federal Columbia River Power System to the Pacific Ocean. It provides critical data for salmon protection and development of more “fish-friendly” hydroelectric facilities. The objective of this study was to design and build a measurement and calibration system for evaluating the JSATS component, because the JSATS requires comprehensive acceptance and performance testing in a controlled environment before it is deployed in the field. The system consists of a reference transducer, a water test tank lined with anechoic material, a motion control unit, a reference receiver, a signal conditioner and amplifier unit, a data acquisition board, MATLAB control and analysis interface, and a computer. The fully integrated system has been evaluated successfully at various simulated distances and using different encoded signals at frequencies within the bandwidth of the JSATS transmitter. It provides accurate acoustic mapping capability in a controlled environment and automates the process that allows real-time measurements and evaluation of the piezoelectric transducers, sensors, or the acoustic fields. The measurement and calibration system has been in use since 2009 for acceptance and performance testing of, and further improvements to, the JSATS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Model-Based Approach to Scintillator/Photomultiplier System Characterization

Scintillator/photomultiplier systems are prevalent in many instruments to measure a variety on nuclear events. When gamma energy from a nuclear event irradiates the scintillator, event radiation interacts with the scintillator material generating photons which are detected by the photomultiplier tube (PMT). The PMT photoelectrons or photocathode current is amplified in the PMT by a number of dynode stages producing a total charge out for a given radiation flux into scintillator. The resulting current is converted to a voltage when passed through a typical load impedance. This voltage is attenuated and provided as input to a digitizer through a variety of signal conditioners (filters, amplifiers, receivers) before analog-to-digital conversion. In this report, we concentrate on the development of analytic models for the scintillator/photomultiplier system and develop both a (1) statistical simulator; and (2) a model-based signal processor to extract the desired signal information while rejecting the noise and uncertainty. We develop the model analytically, transform it to the model-based framework (state-space), and then use actual experimental data to fit the model and apply it to our processing problem.

42 ENGINEERING↗

Hunting the Dark Matter with DEAP/CLEAN

The potential of the DEAP/CLEAN program for direct Dark Matter detection to test various dark matter models is illustrated. The scintillation pulse of a noble liquid like Argon or Neon has two well distinguished time constants allowing a very reliable correlation between pulse shape and type of event. This pulse shape discrimination already provides the power of rejecting a background10{sup 8}-10{sup 9} times larger than the signal. MiniCLEAN, a 500 kg LAr detector, is currently under construction, and a 3.6 ton detector, DEAP-3600, under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ABSOLUTE TIMING OF THE CRAB PULSAR WITH THE INTEGRAL/SPI TELESCOPE

We have investigated the pulse shape evolution of the Crab pulsar emission in the hard X-ray domain of the electromagnetic spectrum. In particular, we have studied the alignment of the Crab pulsar phase profiles measured in the hard X-rays and in other wavebands. To obtain the hard X-ray pulse profiles, we have used six years (2003-2009, with a total exposure of about 4 Ms) of publicly available data of the SPI telescope on-board the International Gamma-Ray Astrophysics Laboratory observatory, folded with the pulsar time solution derived from the Jodrell Bank Crab Pulsar Monthly Ephemeris. We found that the main pulse in the hard X-ray 20-100 keV energy band leads the radio one by 8.18 +- 0.46 milliperiods in phase, or 275 +- 15 mus in time. Quoted errors represent only statistical uncertainties. Our systematic error is estimated to be approx40 mus and is mainly caused by the radio measurement uncertainties. In hard X-rays, the average distance between the main pulse and interpulse on the phase plane is 0.3989 +- 0.0009. To compare our findings in hard X-rays with the soft 2-20 keV X-ray band, we have used data of quasi-simultaneous Crab observations with the proportional counter array monitor on-board the Rossi X-Ray Timing Explorer mission. The time lag and the pulses separation values measured in the 3-20 keV band are 0.00933 +- 0.00016 (corresponding to 310 +- 6 mus) and 0.40016 +- 0.00028 parts of the cycle, respectively. While the pulse separation values measured in soft X-rays and hard X-rays agree, the time lags are statistically different. Additional analysis show that the delay between the radio and X-ray signals varies with energy in the 2-300 keV energy range. We explain such a behavior as due to the superposition of two independent components responsible for the Crab pulsed emission in this energy band.

79 ASTRONOMY AND ASTROPHYSICS↗

Examining the feedback signals used in closed-loop control of intense laser fragmentation of CO{sup +}

A closed-loop feedback system is used to determine the optimal pulse shapes for manipulating the branching ratio of carbon monoxide following ionization by an intense laser pulse. We focus on manipulating the C{sup +}+O and C+O{sup +} branching ratios of excited states of transient CO{sup +}. The feedback control system consists of a high resolution time-of-flight spectrometer coupled via a genetic feedback algorithm to an acousto-optical programmable dispersive filter that is incorporated into the ultrafast laser system. Using the spectrometer resolution to distinguish dissociation pathways and select a specific pathway to drive the algorithm, we are able to demonstrate enhanced control of some fragmentation channels. Principal control analysis indicates that the more specific feedback results in numerically simpler optimal pulse shapes. The combination of a more specific target and reduction in pulse complexity could lead to more straightforward investigations of the control mechanism. Analysis of the pulse shapes in conjunction with measurement of the fragment kinetic energy release distributions obtained from the optimized laser pulses is used to probe the dissociative ionization mechanisms.

74 ATOMIC AND MOLECULAR PHYSICS↗

Front-end Electronics for the ALICE Calorimeters

The ALICE calorimeters PHOS and EMCal are based on Avalanche Photo-Diode (APD) photosensors with Charge Sensitive Preamplifiers (CSP) for readout of the scintillating elements. The amplified signals are read out via 32-channel shaper/digitizer front-end electronics (FEE) with 14-bit effective dynamic range. The electronics is based on second order shapers with dual gain for each channel, getting digitized by ALTRO chips. Each APD channel is equipped with an individual 10-bit APD gain adjustment and 2 x 2 channel clusters generate a 100 ns shaped analog sums output (Fast OR) for the associated Trigger Region Units (TRU). The Fast OR signals are generated by first order shapers with a dynamic range of 12-bit given by the ADC in the TRU cards. Board controller firmware in the FPGA provides local monitoring and configuration of all parameters via the ALICE DCS system. The signal to noise ratio for MIP at 215 MeV is {approx}7 per channel with a noise level of 30 MeV at room temperature for a dynamic range of 80 GeV for PHOS, and the fast-OR RMS noise level is about 75 MeV for a dynamic range of 250 GeV for EMCal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of simultaneous source and bias pulsing in inductively coupled plasma etching

Pulsed rf plasmas show promise to overcome challenges for plasma etching at future technological nodes. In pulsed plasmas, it is important to characterize the transient phenomena to optimize plasma processing of materials. In particular, it is important to evaluate the effect of the ion energy and angular distribution (IEAD) functions during pulsing on etching of nanoscale features. In this work, the impact of simultaneous pulsing of both source and bias in an inductively coupled plasma on plasma characteristics and feature profile evolution is discussed using results from a two-dimensional reactor scale plasma model coupled to a Monte Carlo based feature profile model. Results are discussed for an Ar/Cl{sub 2} gas mixture which is typically used for poly-Si etching. The consequences of duty cycle, pulse shape, and the phase lag between source and bias power pulses on discharge characteristics, IEADs to the wafer, and feature profile evolution are discussed. The low plasma density during the initial period of the pulse was found to introduce a high energy tail component to the IEADs. This high energy tail component can be affected by modifying the pulse shape. The Si etching rate is found to increase with increasing duty cycle but is lower compared to continuous mode of operation due to lower time averaged power deposition. Pulsing the source and bias out of phase provides for increased ion energies and fluxes to the wafer for a given duty cycle.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

New Organic Scintillators for Neutron Detection

This paper present the current work on neutron detection in Soltan Institute for Nuclear Studies. Lately, we have focused our research on the development of new organic scintillators including liquid scintillators for neutron detection and associated measurements. We measured liquid scintillators (also {sup 10}B-doped for thermal neutron detection){sup 3}He tubes, composites, etc. Response of the following detectors on thermal neutrons, fast neutrons and gamma radiation - the pulse shape discrimination (PSD)- has been mainly performed by means of a zero-crossing (ZC) method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compton Imaging Capabilities of AGATA for Background Rejection

In this work we present the results of the test performed at the Laboratori Nazionali di Legnaro (LNL) aiming to characterize the capabilities of the AGATA detectors to discriminate between different gamma source locations. AGATA detectors are position sensitive to the interaction points through Pulse Shape Analysis allowing location of the gamma sources by using Compton imaging algorithm. The final goal is to increase the array sensitivity reducing the background originated outside the AGATA target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LCP Identification Method based on Pulse Shape Analysis

An improved LCP identification method based on Pulse shape analyses has been designed, the module 'Dual Pulse-Shape Analyzer' has been built and tested and resent experimental results of instrument utilizing have been presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital Pulse Processing: A New Paradigm For Nuclear Instrumentation

In recent years, we have seen an impressive increase in the use of digital pulse processing in substitution of standard analog electronic modules for nuclear physics instrumentation. The main advantages of the new standard are compactness, no additional noise after digitization of the pre-amp signal, reliability (no cables and connectors), and possibility of easily reproducing the same tuning set up. Also, it opens new possibilities of pulse shape analysis, not possible with standard analog electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bunch characteristics of an electron beam generated by a diamond secondary emitter amplifier

Electron bunches for high performance free electron lasers are subject to constraints on charge per bunch and pulse shape. A Diamond secondary emitter used in conjunction with a photocathode and drive laser has potential to enable a high brightness, high peak current photoinjector by increasing the effective quantum efficiency of the photocathode. A theoretical characterization of the bunches so produced has been heretofore absent. Using a combination of Monte Carlo and analytical models, the shape of the bunches, their transit time, and emission time constants are determined and shown to be sensitive to the accelerating field in the diamond flake, incident beam profile, doping, and surface conditions. Methods to allow for extension to regimes of technological interest in terms of diamond thickness, external field, and primary pulse shape are given.

07 ISOTOPE AND RADIATION SOURCES↗

An analytical model for pulse shape and electrothermal stability in two-body transition-edge sensor microcalorimeters

High-resolution superconducting gamma-ray sensors show potential for the more accurate analysis of nuclear material. These devices are part of a larger class of microcalorimeters and bolometers based on transition edge sensors (TESs) that have two distinct thermal bodies. We derive the time domain behavior of the current and temperature for compound TES devices in the small signal limit and demonstrate the utility of these equations for device design and characterization. In particular, we use the model to fit pulses from our gamma-ray microcalorimeters and demonstrate how critical damping and electrothermal stability can be predicted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Method of Prompt Fission Neutron Energy Spectrum Unfolding

The prompt neutron emission in spontaneous fission of {sup 252}Cf has been investigated applying digital signal electronics along with associated digital signal processing algorithms. The goal was to find out the reasons of a long time existing discrepancy between theoretical calculations and the measurements of prompt fission neutron (PFN) emission dependence on the total kinetic energy (TKE) of fission fragments (FF). On the one hand the {sup 252}Cf(sf) reaction is one of the main references for nuclear data, on the other hand the understanding of PFN emission mechanism is very important for nuclear fission theory. Using a twin Frisch-grid ionization chamber for fission fragment (FF) detection and a NE213-equivalent neutron detector in total about 10{sup 7} fission fragment-neutron coincidences have been registered. Fission fragment kinetic energy, mass and angular distribution, neutron time-of-flight and pulse shape have been investigated using a 12 bit waveform digitizer. The signal waveforms have been analyzed using digital signal processing algorithms. For the first time the dependence of the number of emitted neutrons as a function of total kinetic energy (TKE) of the fragments is in very good agreement with theoretical calculations in the range of TKE from 140-220 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Generation of Stable (3+1)-dimensional High-intensity Ultrashort Light Pulses

The spatiotemporal dynamics of high-intensity femtosecond laser pulses is studied within a rigorous physical model. The pulse propagation is described by the nonlinear envelope equation. The propagation and the material equations are solved self-consistently at realistic physical conditions. Self-compression of the pulse around single-cycle regime and dramatic increase of the pulse intensity is found. At certain conditions, the peak intensity, transversal width, time duration, and the spatiotemporal pulse shape remain stable with the propagation of the pulse, resembling a soliton formation process. This, to our knowledge, is the first simulation of high-intensity ultrashort soliton formation dynamics in the (3+1)-dimensional case.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗