Search NASASearch

SEARCH · Search NASA

Results for “SIGNAL MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Spectral composition of a measuring signal during measurements of vibration rates of a moving body

Cybernetics diagnostics of machines and mechanisms using the spectral approach is discussed. The problem of establishing the accuracy of determination of the spectral composition is investigated. In systems with rectilinear or rotary movement, the vibrations appear in the form of movement rate vibrations, which are equivalent to frequency modulation of the signal, in proportion to the mean movement rate of the body. The case of a harmonic signal which reproduces and analyzes the characteristics of the frequency modulated signal is discussed. Mathematical models are developed to show the relationships of the parameters.

Daynauskas, I. A. I.

Transmitter Signal Measurements, Task 5C Report

Signal Measurements were obtained on four (4) different airport systems. Systems measured were Localizer (LOC), Very High Frequency Communication, (VHF), Glideslope, (G/S), and Global Positioning System (GPS). The task calls for path loss measurements to be taken at Hartsfield-Jackson International Airport (ATL) and one smaller airport which was Greenville/ Spartanburg Airport (GSP) to determine relative signal strengths on the airport properties.

Horton, Kent

Radiation-Hard Parallel Readout Circuit for Low-Frequency Voltage Signal Measurements

NASA Goddard Space Flight Center (GSFC) has successfully developed and tested a custom-designed low-noise multi-channel digitizer (MCD) application specific integrated circuit (ASIC) for operation in harsh radiation environments. The MCD-ASIC is optimized for low-frequency and low-voltage signal measurements from sensors and transducers. It has 20 input channels where each channel is comprised of auto-zeroed chopper variable-gain amplifier, post amplifier, and a second order ∑∆ modulator. ∑∆ analog-to-digital converter (ADC) relies on oversampling and noise shaping to achieve high-resolution conversion. However, the MCD-ASIC requires digital filtering and decimation to convert the output single bit streams from the ADC to useful data words. A parallel digital platform such as a field-programmable-gate-array (FPGA) is highly suitable to fully leverage the capabilities of the MCD-ASIC. The FPGA controls the MCD-ASIC via serial peripheral interface (SPI) protocol and acquires data from it. A Python-script communicates with the FPGA board through a USB interface on a cross operating platform. Using this architecture, the system is capable of monitoring up to 20 voltage readout channels simultaneously in a real-time manner. Each channel’s parameters can be programmed independently allowing maximum user versatility. In this paper, we present analysis of the analog front-end, the implementation of the digital processing unit on the FPGA, and provide noise performance results from the MCD-ASIC readout.

ASIC

Variable Time Base Integrator Circuit for Buffet Signal Measurements

A measurement circuit to obtain buffet data from wind tunnel models wherein a signal proportional to the average RMS value of buffet data is produced for subsequent recording. Feedback means are employed to suppress the D.C. portion of signals developed by the strain gages during dynamic testing. Automatic recording of gain settings of amplifiers employed in the circuit is also provided.

Batts, Colossie N.

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela

Natural Radio Source and Spacecraft Signal Measurements at Ka-Band (32.0 GHz) and X-Band (8.4 GHz) Using a 34-Meter Beam-Waveguide Antenna

From Intro.: NASA'a Deep Space Network (DSN) Technology Program at the Jet Propulsion Laboratory (JPL) is evaluating the use of the Ka-Band frequency allocation band (31.8 GHz to 32.3 GHz) for deep space to Earth telecommunications...This paper addresses the three current Ka-Band and X-Band activities, 1)KaAp, 2)SURSAT-1, and 3)KaBLE-II's upcoming Ka-Band experiments aboard Mars Global Surveyor.

Deep Space Network DSN Ka-Band Ka frequency

UCMS - A new signal parameter measurement system using digital signal processing techniques

The User Constraint Measurement System (UCMS) is a hardware/software package developed by NASA Goddard to measure the signal parameter constraints of the user transponder in the TDRSS environment by means of an all-digital signal sampling technique. An account is presently given of the features of UCMS design and of its performance capabilities and applications; attention is given to such important aspects of the system as RF interface parameter definitions, hardware minimization, the emphasis on offline software signal processing, and end-to-end link performance. Applications to the measurement of other signal parameters are also discussed.

Choi, H. J.

Analysis of the Performance Characteristics of the Five-Channel Microtops II Sun Photometer for Measuring Aerosol Optical Thickness and Precipitable Water Vapor

Five Microtops II sun photometers were studied in detail at the NASA Goddard Space Flight Center (GSFC) to determine their performance in measuring aerosol optical thickness (AOT or Tau(sub alphalambda) and precipitable column water vapor (W). Each derives Tau(sub alphalambda) from measured signals at four wavelengths lambda (340, 440, 675, and 870 nm), and W from the 936 nm signal measurements. Accuracy of Tau(sub alphalambda) and W determination depends on the reliability of the relevant channel calibration coefficient (V(sub 0)). Relative calibration by transfer of parameters from a more accurate sun photometer (such as the Mauna-Loa-calibrated AERONET master sun photometer at GSFC) is more reliable than Langley calibration performed at GSFC. It was found that the factory-determined value of the instrument constant for the 936 nm filter (k= 0.7847) used in the Microtops' internal algorithm is unrealistic, causing large errors in V(sub 0(936)), Tau(sub alpha936), and W. Thus, when applied for transfer calibration at GSFC, whereas the random variation of V(aub 0) at 340 to 870 nm is quite small, with coefficients of variation (CV) in the range of 0 to 2.4%, at 936 nm the CV goes up to 19%. Also, the systematic temporal variation of V(sub 0) at 340 to 870 nm is very slow, while at 936 nm it is large and exhibits a very high dependence on W. The algorithm also computes Tau(sub alpha936) as 0.91Tau(sub alpha870), which is highly simplistic. Therefore, it is recommended to determine Tau(sub alpha936) by logarithmic extrapolation from Tau(sub alpha675) and Tau(sub alpha 870. From the operational standpoint of the Microtops, apart from errors that may result from unperceived cloud contamination, the main sources of error include inaccurate pointing to the Sun, neglecting to clean the front quartz window, and neglecting to calibrate correctly. If these three issues are adequately taken care of, the Microtops can be quite accurate and stable, with root mean square (rms) differences between corresponding retrievals from clean calibrated Microtops and the AERONET sun photometer being about +/-0.02 at 340 nm, decreasing down to about +/-0.01 at 870 nm.

Ichoku, Charles

Phase-Noise and Amplitude-Noise Measurement of Low-Power Signals

Measuring the phase fluctuation between a pair of low-power microwave signals, the signals must be amplified before detection. In such cases the phase noise of the amplifier pair is the main cause of 1/f background noise of the instrument. this article proposes a scheme that makes amplification possible while rejecting the close in 1/f (flicker) noise of the two amplifiers. Noise rejection, which relies upon the understanding of the amplifier noise mechanism does not require averaging. Therefore, our scheme can also be the detector of a closed loop noise reduction system. the first prototype, compared to a traditional saturated mixer system under the same condition, show a 24 dB noise reduction of the 1/f region.

phase noise

Precision signal power measurement

Accurate estimation of signal power is an important Deep Space Network (DSN) consideration. Ultimately, spacecraft power and weight is saved if no reserve transmitter power is needed to compensate for inaccurate measurements. Spectral measurement of the received signal has proved to be an effective method of estimating signal power over a wide dynamic range. Furthermore, on-line spectral measurements provide an important diagnostic tool for examining spacecraft anomalies. Prototype equipment installed at a 64-m-diameter antenna site has been successfully used to make measurements of carrier power and sideband symmetry of telemetry signals received from the Mariner Mars 1971 spacecraft.

Winkelstein, R.

Technology test bed engine real-time failure control

The Real-Time Failure Control (RTFC) program involves development of a failure detection algorithm, for the Space Shuttle Main Engine (SSME). This failure detection approach is signal-based and entails monitoring SSME measurement signals based on predetermined as well as on-line computed mean and standard deviation values. Twenty-four engine measurements are monitored in the algorithm and provisions are made to add more parameters if needed. Each of the first values of every measurement signal at the algorithm start is checked against safety limits placed around a pre-computed engine-to-engine mean value (MV) with a bandwidth equal to a given multiple of the pre-computed standard deviation (SD). If several parameters are out of the bounds of these limits a failure is signaled. During the first two seconds (after algorithm start) a moving average (MA) and a SD is computed on-line in real-time. The moving average of each parameter is computed by averaging the incoming signal measurement with the four most recent previous signal measurements. The moving average is updated at every sampling interval (40 msec) and is checked against a similar safety band around the initial signal value for each parameter. If several anomalies are registered, a failure is signaled by the algorithm. At the end of the two-second interval the MA is fixed as the mean value for the rest of the algorithm operation and a safety band is placed above and below this value equal to a multiple of the computed SD. However, the safety band is adjusted by adjusting the mean value when propellant tank repressurization and venting take place. 'Influence Coefficients' are used to make the necessary adjustments to the safety limits of those parameters that are affected by repressurization and venting or valve closure and opening. The MA is, in both cases, continuously updated and checked against the safety band. Once more, if several parameters exceed the limits a failure is signaled. At the start of every scheduled power transient the algorithm is stopped. It is re-initiated after two seconds from the termination of the power transient and the process is repeated. The final report is divided into four major sections. The most encompassing of all is the discussion section that has sub-sections on: (1) RTFC algorithm development, (2) RTFC simulations; (3) RTFC current limitations; and (4) enhancements planned for.

Panossian, Hagop V.

Measuring signal-to-noise ratio automatically

Automated method of measuring signal-to-noise ratio in digital communication channels is more precise and 100 times faster than previous methods used. Method based on bit-error-rate (B&R) measurement can be used with cable, microwave radio, or optical links.

Bergman, L. A.

Comparison Between Sea Surface Wind Speed Estimates From Reflected GPS Signals and Buoy Measurements

Reflected signals from the Global Positioning System (GPS) have been collected from an aircraft at approximately 3.7 km altitude on 5 different days. Estimation of surface wind speed by matching the shape of the reflected signal correlation function against analytical models was demonstrated. Wind speed obtained from this method agreed with that recorded from buoys to with a bias of less than 0.1 m/s, and with a standard derivation of 1.3 meters per second.

Garrison, James L.

Interferometer for Measuring Acoustic Signals

Optical-fiber interferometer measures wave amplitude without contacting specimen surface. System contains remote detector head. Head includes beam splitter that divides input beam and recombines output beams, while spatial filter filters interference pattern at beam-splitter output; and lens focuses this on detector. Beams focused on specimen surface to record acoustic signals.

Claus, R. O.