Search NASA⌕ Search

SEARCH · Search NASA

Results for “SILVER 125”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation program for secondary spacecraft cells

The results of life cycle tests of secondary spacecraft cells are summarized. Cells consisted of seven sample classifications ranging from 3.0 to 20 ampere-hours, 1326 nlc nickel cadmium, 183 silver cadmium, and 125 silver zinc sealed cells. Variables examined include load, charge control, and temperature conditions.

Harkness, J. D.↗

Nuclear Data Sheets for A = 125

The 1999 evaluation for A = 125 mass chain (1999Ka26) has been revised using experimental results from decays and reactions. Adopted values for the level and decay properties are tabulated. Inconsistencies and discrepancies are noted.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development and fabrication of sealed silver-zinc cells, phase 1

A facility was designed, constructed and equipped for the production of prismatic alkaline rechargeable battery cells using inorganic (ceramic) separators. This unique facility is environmentally controlled and contains separate areas for electrode fabrication, separator processing, cell assembly, cell finishing and testing. An initial production run of 125 sealed silver zinc cells, using inorganic separators, was made in the facility in order to provide samples for baseline performance tests. Ten of these cells were given performance characterization and life cycle tests.

Blake, I. C.↗

Substrate Matters: Ionic Silver Alters Lettuce Growth, Nutrient Uptake, and Root Microbiome in a Hydroponics System

Ionic silver (Ag+) is being investigated as a residual biocide for use in NASA spacecraft potable water systems on future crewed missions. This water will be used to irrigate future spaceflight crop production systems. We have evaluated the impact of three concentrations (31 ppb, 125 ppb, and 500 ppb) of ionic silver biocide solutions on lettuce in an arcillite (calcinated clay particle substrate) and hydroponic (substrate-less) growth setup after 28 days. Lettuce plant growth was reduced in the hydroponic samples treated with 31 ppb silver and severely stunted for samples treated at 125 ppb and 500 ppb silver. No growth defects were observed in arcillite-grown lettuce. Silver was detectable in the hydroponic-grown lettuce leaves at each concentration but was not detected in the arcillite-grown lettuce leaves. Specifically, when 125 ppb silver water was applied to a hydroponics tray, Ag+ was detected at an average amount of 7 μg/g (dry weight) in lettuce leaves. The increase in Ag+ corresponded with a decrease in several essential elements in the lettuce tissue (Ca, K, P, S). In the arcillite growth setup, silver did not impact the plant root zone microbiome in terms of alpha diversity and relative abundance between treatments and control. However, with increasing silver concentration, the alpha diversity increased in lettuce root samples and in the water from the hydroponics tray samples. The genera in the hydroponic root and water samples were similar across the silver concentrations but displayed different relative abundances. This suggests that ionic silver was acting as a selective pressure for the microbes that colonize the hydroponic water. The surviving microbes likely utilized exudates from the stunted plant roots as a carbon source. Analysis of the root-associated microbiomes in response to silver showed enrichment of metagenomic pathways associated with alternate carbon source utilization, fatty-acid synthesis, and the ppGpp (guanosine 3′-diphosphate 5′-diphosphate) stringent response global regulatory system that operates under conditions of environmental stress. Nutrient solutions containing Ag+ in concentrations greater than 31 ppb in hydroponic systems lacking cation-exchange capacity can severely impact crop production due to stunting of plant growth.

lettuce↗

Novel Metal Sulfides to Achieve Effective Capture and Durable Consolidation of Radionuclides

This report documents the work done under NEUP grant to examine the capability of novel chalcogels and some binary metal chalcogenides as a host matrix for the capture of gaseous iodine and the feasibility of their iodine-laden materials to be converted into a permanent waste form. The presented work was conducted over last two years. A number of novel chalcogels Zn 2 Sn 2 S 6 , Sb 4 Sn 4 S 12 , NiMoS 4 , CoMoS 4 , antimony sulfide (SbS x ) chalcogels, silver functionalized chalcogels and binary metal sulfides (Sb 2 S 3 ) were developed and studies for their iodine absorption efficacies. A new and simple route was devised for the large scale preparation of antimony sulfide chalcogel. The chalcogel was obtained by treating Sb 2 S 3 with Na 2 S in the presence of water followed by addition of formamide. The obtained gels have a low-density sponge like network of meso porous nature having BET surface area of 125 m 2 /g. The chalcogels, silver functionalized chalcogel and the binary metal sulfides were exposed to iodine vapors in a closed container. Silver-functionalized chalcogels and Sb 2 S 3 powders showed iodine uptake up to 100 wt%, the highest iodine uptake of 200 wt% was observed for the SbS-III chalcogel. The PXRD patterns of iodine-laden specimens revealed that iodine shows spontaneous chemisorption to the matrix used. The iodine loaded chalcogels and the binary chalcogenides were sealed under vacuum in fused silica ampoules and heated in a temperature controlled furnace. The consolidated products were analyzed by PXRD, energy dispersive spectroscopy (EDS), UV-Vis and Raman spectroscopy. The final products were found to be amorphous in most of the cases with high amount (~4-35 wt%) of iodine and aapproximately ~60- 90 % of the absorbed iodine could be consolidated into the final waste form. Alginate reinforced composite scaffolds with SbS/SnS chalcogels and Sb 2 S 3 bulk powder were also fabricated aiming to study their efficacy as host matrices in capturing the gaseous molecular iodine in dynamic mode from nuclear spent fuel. The obtained composites looks robust in comparison to their respective pristine chalcogels and Sb 2 S 3 bulk powder.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Accelerated Alpha-s deterioration in a geostationary orbit

Between the Teflon substrate and the interference filter a 2 micron varnish layer was sandwiched in. The bending radius of the SSM, measured on a cone, decreased from about 13 mm to 6 mm prior to interference filter fracture, due to increased tensile strength of its substrate. These samples, and for comparison samples of the same make but without varnish and a conductive layer were included in the test. Additionally 2 Teflon FEP samples without the protective interference filter, one of them with a conductive layer, were tested. The sample substrate was 125 micron Teflon FEP, with vapor deposited silver reflector and a thin Inconel film for corrosion protection.

Husmann, O. K.↗

Experimental impacts into Teflon targets and LDEF thermal blankets

The Long Duration Exposure Facility (LDEF) exposed approximately 20 sq m of identical thermal protective blankets, predominantly on the Ultra-Heavy Cosmic Ray Experiment (UHCRE). Approximately 700 penetration holes greater than 300 micron in diameter were individually documented, while thousands of smaller penetrations and craters occurred in these blankets. As a result of their 5.7 year exposure and because they pointed into a variety of different directions relative to the orbital motion of the nonspinning LDEF platform, these blankets can reveal important dynamic aspects of the hypervelocity particle environment in near-earth orbit. The blankets were composed of an outer teflon layer (approximately 125 micron thick), followed by a vapor-deposited rear mirror of silver (less than 1000 A thick) that was backed with an organic binder and a thermal protective paint (approximately 50 to 75 micron thick), resulting in a cumulative thickness (T) of approximately 175 to 200 microns for the entire blanket. Many penetrations resulted in highly variable delaminations of the teflon/metal or metal/organic binder interfaces that manifest themselves as 'dark' halos or rings, because of subsequent oxidation of the exposed silver mirror. The variety of these dark albedo features is bewildering, ranging from totally absent, to broad halos, to sharp single or multiple rings. Over the past year experiments were conducted over a wide range of velocities (i.e., 1 to 7 km/s) to address velocity dependent aspects of cratering and penetrations of teflon targets. In addition, experiments were performed with real LDEF thermal blankets to duplicate the LDEF delaminations and to investigate a possible relationship of initial impact conditions on the wide variety of dark halo and ring features.

Hoerz, F.↗

Cysteine sensing by plasmons of silver nanocubes

Noble metal nanoparticles are considered to be valuable nanostructures in the field of sensors due to their spectral response sensitivity to small changes in the surrounding refractive index which enables them to detect a small amount of molecules. In this research, we use silver nanocubes of about 50 nm length to detect low concentrations of cysteine, a semi-essential amino acid. Following cysteine adsorption onto the nanocubes, a redshift in the plasmonic modes was observed, enabling the detection of cysteine down to 10 µM and high sensitivity of about 125 nm/RIU (refractive index units). Furthermore, we found that multilayer adsorption of cysteine leads to the stabilization of the silver nanocubes. The cysteine growth onto the nanocubes was also characterized by high-resolution transmission electron microscopy (HR-TEM). - Highlights: • Silver nanocubes (50 nm length) are used to detect low concentrations of cysteine. • A redshift in the plasmonic modes was observed following cysteine adsorption onto the nanocubes. • The cysteine growth onto the nanocubes is also characterized by TEM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Easily-assembled helical heater

Rugged, compact heater is made from 0.1 mm diameter Inconel wire (125 ohms per meter). Heating element is enclosed in PTFE heat-shrink sleeve. Ends of coal pass through small ceramic spools and are silver-brazed to lead wires. Junctions are potted in epoxy or silicon and covered with crimp sleeves and heat-shrink tubing.

Pizzeck, D. E.↗

PVA Based Ternary Nanocomposites with Enhanced Properties Prepared by Using a Combination of Rice Starch Nanocrystals and Silver Nanoparticles

Ternary nanocomposite films exhibiting better properties were prepared by incorporating two different nanoparticles such as rice starch nanocrystals (RSN) and silver nanoparticles (AgNPs) together in polyvinyl alcohol (PVA) matrix at various concentrations. The morphological evaluation using atomic force microscopy revealed that the particle size of RSN nanoparticles varied from 50 to 125 nm. The nanocomposite films made using these nanoparticles were evaluated for its chemical, mechanical and thermal properties. FTIR spectra of the films revealed some specific vibrational bands of RSN along with the characteristic bands of PVA. The mechanical property analysis of nanocomposite films indicated better tensile strength and elongation properties, which can be attributed to the strong interaction of PVA with RSN and AgNPs. The thermal properties of these films were also evaluated. These ternary nanocomposites exhibited superior mechanical properties, which is very much beneficial as far as the end use applications are concerned.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Charge carrier effective mass and concentration derived from combination of Seebeck coefficient and Te 125 NMR measurements in complex tellurides

Thermoelectric materials utilize the Seebeck effect to convert heat to electrical energy. The Seebeck coefficient (thermopower), S, depends on the free (mobile) carrier concentration, n, and effective mass, m*, as S ~ m*/n 2/3 . The carrier concentration in tellurides can be derived from 125 Te nuclear magnetic resonance (NMR) spin-lattice relaxation measurements. The NMR spin-lattice relaxation rate, 1/T 1 , depends on both n and m* as 1/T 1 ~(m*) 3/2 n (within classical Maxwell-Boltzmann statistics) or as 1/T1~(m*) 2 n 2/3 (within quantum Fermi-Dirac statistics), which challenges the correct determination of the carrier concentration in some materials by NMR. Here it is shown that the combination of the Seebeck coefficient and 125 Te NMR spin-lattice relaxation measurements in complex tellurides provides a unique opportunity to derive the carrier effective mass and then to calculate the carrier concentration. This approach was used to study Ag x Sb x Ge 50–2x Te 50 , well-known GeTe-based high-efficiency tellurium-antimony-germanium-silver thermoelectric materials, where the replacement of Ge by [Ag+Sb] results in significant enhancement of the Seebeck coefficient. Thus, values of both m* and n derived using this combination show that the enhancement of thermopower can be attributed primarily to an increase of the carrier effective mass and partially to a decrease of the carrier concentration when the [Ag+Sb] content increases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A fixed tilt solar collector employing reversible vee-through reflectors and evaluated tube receivers for solar heating and cooling systems

The Vee-Trough/Evacuated Tube Collector (VTETC) was analyzed rigorously and various mathematical models were developed to calculate the optical performance of the vee-trough concentrators, and the quasi-steady state thermal performance of the evacuated tube receivers. Tests were run to verify the mathematical analyses. Back-silvered glass mirror, Alzak, Aluminized Teflon, and Kinglux (electropolished aluminum reflectors) were tested. Additional tests were run at temperatures ranging from 80 to 190 C (176-374 F). For the glass mirror reflectors, peak efficiencies, based on aperture area and operating temperatures of 125 C (257 F), were over 40%. Efficiencies of about 40% were observed at temperatures of 150 C (302 F) and 30% at 175 C (347 F). Test data for several days, predicted daily useful heats, and efficiency values are presented for a full year. These theoretical values were then compared with actual data points for the same temperature range.

Selcuk, M. K.↗

SU-E-T-123: Anomalous Altitude Effect in Permanent Implant Brachytherapy Seeds

Purpose: Permanent seed implant brachytherapy procedures require the measurement of the air kerma strength of seeds prior to implant. This is typically accomplished using a well-type ionization chamber. Previous measurements (Griffin et al., 2005; Bohm et al., 2005) of several low-energy seeds using the air-communicating HDR 1000 Plus chamber have demonstrated that the standard temperature-pressure correction factor, P{sub TP}, may overcompensate for air density changes induced by altitude variations by up to 18%. The purpose of this work is to present empirical correction factors for two clinically-used seeds (IsoAid ADVANTAGE™ {sup 103}Pd and Nucletron selectSeed {sup 125}I) for which empirical altitude correction factors do not yet exist in the literature when measured with the HDR 1000 Plus chamber. Methods: An in-house constructed pressure vessel containing the HDR 1000 Plus well chamber and a digital barometer/thermometer was pumped or evacuated, as appropriate, to a variety of pressures from 725 to 1075 mbar. Current measurements, corrected with P{sub TP}, were acquired for each seed at these pressures and normalized to the reading at ‘standard’ pressure (1013.25 mbar). Results: Measurements in this study have shown that utilization of P{sub TP} can overcompensate in the corrected current reading by up to 20% and 17% for the IsoAid Pd-103 and the Nucletron I-125 seed respectively. Compared to literature correction factors for other seed models, the correction factors in this study diverge by up to 2.6% and 3.0% for iodine (with silver) and palladium respectively, indicating the need for seed-specific factors. Conclusion: The use of seed specific altitude correction factors can reduce uncertainty in the determination of air kerma strength. The empirical correction factors determined in this work can be applied in clinical quality assurance measurements of air kerma strength for two previously unpublished seed designs (IsoAid ADVANTAGE™ {sup 103}Pd and Nucletron selectSeed {sup 125}I) with the HDR 1000 Plus well chamber.

07 ISOTOPE AND RADIATION SOURCES↗

Study of CNT growth using nanocatalyst Ag precursor by HWC-VHF-PECVD

The study of CNT growth has been done by using silver (Ag) nanocatalyst as a guide precursor on corning glass 7059 substrate. The silver catalyst was prepared by the evaporation method by varying deposition time for 50, 25, and 14 seconds. The silver films were then annealed at temperature of 400°C for 4 hours. From Scanning Electron Microscope (SEM) and Energy Dispersive X-ray Spectroscopy (EDX) results the grain sizes are 65 nm, 57 nm, and 33 nm, and also the atomic compositions are 6,06%, 4,52%, and 3,73% for 14, 25 and 50 seconds samples, respectively. The 33 nm samples were then used for CNT growth by using Hot Wire Cell (HWC) – Very High Frequency (VHF) – Plasma Enhanced Chemical Vapor Deposition (PECVD) at 275 ° C deposition temperature and pressure of 300 mTorr. The rf power was varied from 8 to 20 watts, with deposition time for 60 minutes. The methane (CH4) 99.999% was used as Carbon sources. Hydrogen gas (H2) was used to etch the oxide layer formed during the pre-deposition process. The diameter and length for the CNT are 125 nm and 1.650 to 2.989 nm respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AGR-2 Loose Particle Heating Tests in the Furnace for Irradiated TRISO Testing

A furnace system was developed to thermally expose individual tristructural-isotropic (TRISO) coated particles to expand upon established postirradiation examination (PIE) safety testing that is used to explore particle failures and fission product release from compacts. Two systems were installed in the Irradiated Fuels Examination Facility (IFEL) at Oak Ridge National Laboratory (ORNL). The targeted design was intended to be simple and flexible to allow a range in conditions to be explored. Initial inert atmosphere testing indicated the presence of particle failures, so modifications to the testing approach were implemented to improve the furnace operation. Ultimately, burnback particles were analyzed to provide a direct measurement of fission product release, thus avoiding the complications from integral release that were observed during whole compact testing. Particles were exposed to temperatures ranging 1,150–1,300°C for up to 1,500 h and 1,600°C up to 500 h. No indication of uniform release of fission products such as 106 Ru, 125 Sb, or 154 Eu was observed, however, indication of particle dependent 154 Eu release was suggested for select particles. Exploration of 110m Ag release was limited to 1,150°C and 1,300°C up to 500 h. The analysis indicated that there was nonuniform release of 110m Ag and supports a possible bimodal temperature dependence on silver release.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A revised dosimetric characterization of the model S700 electronic brachytherapy source containing an anode-centering plastic insert and other components not included in the 2006 model

Purpose: The model S700 Axxent electronic brachytherapy source by Xoft, Inc., was characterized by Rivard et al. in 2006. Since then, the source design was modified to include a new insert at the source tip. Current study objectives were to establish an accurate source model for simulation purposes, dosimetrically characterize the new source and obtain its TG-43 brachytherapy dosimetry parameters, and determine dose differences between the original simulation model and the current model S700 source design. Methods: Design information from measurements of dissected model S700 sources and from vendor-supplied CAD drawings was used to aid establishment of an updated Monte Carlo source model, which included the complex-shaped plastic source-centering insert intended to promote water flow for cooling the source anode. These data were used to create a model for subsequent radiation transport simulations in a water phantom. Compared to the 2006 simulation geometry, the influence of volume averaging close to the source was substantially reduced. A track-length estimator was used to evaluate collision kerma as a function of radial distance and polar angle for determination of TG-43 dosimetry parameters. Results for the 50 kV source were determined every 0.1 cm from 0.3 to 15 cm and every 1° from 0° to 180°. Photon spectra in water with 0.1 keV resolution were also obtained from 0.5 to 15 cm and polar angles from 0° to 165°. Simulations were run for 10{sup 10} histories, resulting in statistical uncertainties on the transverse plane of 0.04% at r = 1 cm and 0.06% at r = 5 cm. Results: The dose-rate distribution ratio for the model S700 source as compared to the 2006 model exceeded unity by more than 5% for roughly one quarter of the solid angle surrounding the source, i.e., θ ≥ 120°. The radial dose function diminished in a similar manner as for an {sup 125}I seed, with values of 1.434, 0.636, 0.283, and 0.0975 at 0.5, 2, 5, and 10 cm, respectively. The radial dose function ratio between the current and the 2006 model had a minimum of 0.980 at 0.4 cm, close to the source sheath and for large distances approached 1.014. 2D anisotropy function ratios were close to unity for 50° ≤ θ ≤ 110°, but exceeded 5% for θ < 40° at close distances to the sheath and exceeded 15% for θ > 140°, even at large distances. Photon energy fluence of the updated model as compared to the 2006 model showed a decrease in output with increasing distance; this effect was pronounced at the lowest energies. A decrease in photon fluence with increase in polar angle was also observed and was attributed to the silver epoxy component. Conclusions: Changes in source design influenced the overall dose rate and distribution by more than 2% in several regions. This discrepancy is greater than the dose calculation acceptance criteria as recommended in the AAPM TG-56 report. The effect of the design change on the TG-43 parameters would likely not result in dose differences outside of patient applicators. Adoption of this new dataset is suggested for accurate depiction of model S700 source dose distributions.

60 APPLIED LIFE SCIENCES↗

AGR-1 Compact 4-1-1 Post-Irradiation Examination Results

Destructive post-irradiation examination was performed on AGR-1 fuel Compact 4-1-1, which was irradiated to a final compact-average burnup of 19.4% FIMA (fissions per initial metal atom) and a time-average, volume-average temperature of 1072°C. The analysis of this compact focused on characterizing the extent of fission product release from the particles and examining particles to determine the condition of the kernels and coating layers. The work included deconsolidation of the compact and leach-burn-leach analysis, visual inspection and gamma counting of individual particles, metallurgical preparation of selected particles, and examination of particle cross-sections with optical microscopy, electron microscopy, and elemental analysis. Deconsolidation-leach-burn-leach (DLBL) analysis revealed no particles with failed TRISO or failed SiC layers (as indicated by very low uranium inventory in all of the leach solutions). The total fractions of the predicted compact inventories of fission products Ce-144, Cs-134, Cs-137, and Sr-90 that were present in the compact outside of the SiC layers were <2×10 -6 , based on DLBL data. The Ag-110m fraction in the compact outside the SiC layers was 3.3×10 -2 , indicating appreciable release of silver through the intact coatings and subsequent retention in the OPyC layers or matrix. The Eu-154 fraction was 2.4×10 -4 , which is equivalent to the inventory in one average particle, and indicates a small but measurable level of release from the intact coatings. Gamma counting of 61 individual particles indicated no particles with anomalously low fission product retention. The average ratio of measured inventory to calculated inventory was close to a value of 1.0 for several fission product isotopes (Ce-144, Cs-134, and Cs-137), indicating good retention and reasonably good agreement with the predicted inventories. Measured-to-calculated (M/C) activity ratios for fission products Eu-154, Eu-155, Ru-106, Sb-125, and Zr-95 were significantly less than 1.0. However, as no significant release of these fission products from compacts was noted during previous analysis of the AGR-1 capsule components, the low M/C ratios are most likely an indication of a bias in the inventories predicted by physics simulations of the AGR-1 experiment. The distribution of Ag-110m M/C ratios was centered on a value of 1.02 and was fairly broad (standard deviation of 0.18, with values as high as 1.42 and as low as 0.68). Based on all data gathered to date, it is believed that silver retention in the particles was on average relatively high, but that the broad distribution in values among the particles represents significant variation in the inventory of Ag-110m generated in the particles. Ceramographic analysis of particle cross-sections revealed many of the characteristic microstructures often observed in irradiated AGR-1 particles from other fuel compacts. Palladium-rich fission product clusters were observed in the IPyC and SiC layers near the IPyC-SiC interface of three Compact 4-1-1 particle cross-sections. In spite of the presence of fission product clusters in the SiC layer, no significant corrosion or degradation of the layer was observed in any of the particles examined.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

In Situ ATR–SEIRAS of Carbon Dioxide Reduction at a Plasmonic Silver Cathode

Illumination of a voltage-biased plasmonic Ag cathode during CO 2 reduction results in a suppression of the H 2 evolution reaction while enhancing CO 2 reduction. This effect has been shown to be photonic rather than thermal, but the exact plasmonic mechanism is unknown. Here in this paper, we conduct an in situ ATR–SEIRAS (attenuated total reflectance–surface-enhanced infrared absorption spectroscopy) study of a sputtered thin film Ag cathode on a Ge ATR crystal in CO 2 -saturated 0.1 M KHCO 3 over a range of potentials under both dark and illuminated (365 nm, 125 mW cm –2 ) conditions to elucidate the nature of this plasmonic enhancement. We find that the onset potential of CO 2 reduction to adsorbed CO on the Ag surface is -0.25 V RHE and is identical in the light and the dark. As the production of gaseous CO is detected in the light near this onset potential but is not observed in the dark until -0.5 V RHE , we conclude that the light must be assisting the desorption of CO from the surface. Furthermore, the HCO 3 – wavenumber and peak area increase immediately upon illumination, precluding a thermal effect. We propose that the enhanced local electric field that results from the localized surface plasmon resonance (LSPR) is strengthening the HCO 3 – bond, further increasing the local pH. This would account for the decrease in H 2 formation and increase the CO 2 reduction products in the light.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗