Water droplet size determination for breakup of large diameter jets
Wind tunnel photography for determining water droplet size in breakup of water jets
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Wind tunnel photography for determining water droplet size in breakup of water jets
Maximum model-size determination and effect of sting diameter on entry shape and sphere for low Mach number testing - Apollo spacecraft wind tunnel tests
Instrumentation and data interpretation method for particle size determination by low-angle light scattering
A proposed method of measuring the size of particles entrained in a flow of a liquid or gas would involve utilization of data from digital particle-image velocimetry (DPIV) of the flow. That is to say, with proper design and operation of a DPIV system, the DPIV data could be processed according to the proposed method to obtain particle sizes in addition to particle velocities. As an additional benefit, one could then compute the mass flux of the entrained particles from the particle sizes and velocities. As in DPIV as practiced heretofore, a pulsed laser beam would be formed into a thin sheet to illuminate a plane of interest in a flow field and the illuminated plane would be observed by means of a charge-coupled device (CCD) camera aimed along a line perpendicular to the illuminated plane. Unlike in DPIV as practiced heretofore, care would be taken to polarize the laser beam so that its electric field would lie in the illuminated plane, for the reason explained in the next paragraph. The proposed method applies, more specifically, to transparent or semitransparent spherical particles that have an index of refraction different from that of the fluid in which they are entrained. The method is based on the established Mie theory, which describes the scattering of light by diffraction, refraction, and specular reflection of light by such particles. In the case of a particle illuminated by polarized light and observed in the arrangement described in the preceding paragraph, the Mie theory shows that the image of the particle on the focal plane of the CCD camera includes two glare spots: one attributable to light reflected toward the camera and one attributable to light refracted toward the camera. The distance between the glare spots is a known function of the size of the particle, the indices of refraction of the particle material, and design parameters of the camera optics. Hence, the size of a particle can be determined from the distance between the glare spots. The proposed method would be implemented in an algorithm that would automatically identify, and measure the distance between, the glare spots for each particle for which a suitable image has been captured in a DPIV image frame. The algorithm (see figure) would begin with thresholding of data from the entire image frame to reduce noise, thereby facilitating discrimination of particle images from the background and aiding in the separation of overlapping particles. It is important not to pick a threshold level so high that the light intensity between a given pair of glare spots does not fall below the threshold value, leaving the glare spots disconnected. The image would then be scanned in a sequence of rows and columns of pixels to identify groups of adjacent pixels that contain nonzero brightnesses and that are surrounded by pixels of zero brightness. Each such group would be assumed to constitute the image of one particle. Each such group would be further analyzed to determine whether the image was saturated; saturated particle images must be rejected because the locations of glare spots in saturated images cannot accurately be determined. Within each unsaturated particle image, the centroids (deemed to be the locations) of the glare spots would be determined by means of gradients of brightness distributions and three-point horizontal and three-point vertical Gaussian estimates based on the brightness values of the brightest pixels and the pixels adjacent to them. If the brightness of a given particle image contained only one peak, then it would be assumed that a second glare spot did not exist and that image would be rejected.
Three-quarters of a century have passed since the first engineering study of a human mission to Mars in 1948. During that time, dozens of study teams at NASA, its contractors, and other organizations in the U.S. and abroad have confronted what NASA mission architect John Connolly and his colleagues have called “the ultimate systems challenge.” This historical review of those studies focuses on the question of crew size and its relationship to crew workload.
It is pointed out that until very recently not even a crude idea of the sizes was available for any but the five brightest satellites and, more marginally, the three brightest asteroids. Attention is given to three new techniques which are yielding radii for dozens of small objects and which, by virtue of their independence of angular size, are capable of extension to even smaller and fainter objects. The first new technique, and by far the most precise, is to derive the radius, and in many cases the shape as well, from timings of an occultation of a star by the small body. Both of the other new techniques are based on methods of determining surface reflectivities, since once the geometric albedo is known, the radius can be determined from the brightness.
Explore the source record for details and available documents.
In compressorless Diesel engines and in explosion engines using fuels with high boiling points it is difficult to effect a good combustion of the fuel mixture. This report presents different methods for calculating the size and uniformity of fuel droplets and mixtures.
Aerosol mean particle size determined by rapid approximate method based on Mie light scattering theory
In this paper, an analytical treatment of the atmospheric remote sensing problem of determining the raindrop size distribution (DSD) with a spaceborne multifrequency microwave nadir-looking radar system is presented. It is typically assumed that with two radar measurements at different frequencies one ought to be able to calculate two state variables of the DSD: a bulk quantity, such as the rain rate, and a distribution shape parameter. To determine if this nonlinear problem can indeed be solved, the DSD is modeled as a Gamma distribution and quadratic approximations to the corresponding radar-rain relations are used to examine the invertibility of the resulting system of equations in the case of two as well as three radar frequencies. From the investigation, it is found that for regions of DSD state space multiple solutions exist for two or even three different frequency radar measurements. This should not be surprising given the nonlinear coupled nature of the problem.
Polarization properties of the angularly scattered laser light from a volume of air are used to determine the size distribution of the aerosol particles within the volume by the use of appropriate inversion techniques. Similar techniques are employed to determine a mean size distribution of the particulates within a vertical column through the atmosphere from determinations of the aerosol optical depth as a function of wavelength. In both of these examples, a modification of an inversion technique originally described by Twomey has been employed. Details of this method are presented as well as results from actual measurements employing bistatic lidar and solar radiometer.
Combined photometric and radiometric observations can be used to determine the albedos and radii of airless solar-system objects such as asteroids and most satellites. We use recent observations of the Galilean satellites to derive a new calibration of this method and use these results to calculate the radii and albedos of eight bright asteroids. Possible errors in the method are also discussed.
A dye-tracer technique has been developed whereby the quantity of dyed water collected on a blotter-wrapped body exposed to an air stream containing a dyed-water spray cloud can be colorimetrically determined in order to obtain local collection efficiencies, total collection efficiency, and rearward extent of impingement on the body. In addition, a method has been developed whereby the impingement characteristics obtained experimentally for a body can be related to theoretical impingement data for the same body in order to determine the droplet size distribution of the impinging cloud. Several cylinders, a ribbon, and an aspirating device to measure cloud liquid-water content were used in the studies presented herein for the purpose of evaluating the dye-tracer technique. Although the experimental techniques used in the dye-tracer technique require careful control, the methods presented herein should be applicable for any wind tunnel provided the humidity of the air stream can be maintained near saturation.
The effects of the grid transparency and finite collector size on the values of thermal ion density and temperature determined by the standard RPA (retarding potential analyzer) analysis method are investigated. The current-voltage curves calculated for varying RPA parameters and a given ion mass, temperature, and density are analyzed by the standard RPA method. It is found that only small errors in temperature and density are introduced for an RPA with typical dimensions, and that even when the density error is substantial for nontypical dimensions, the temperature error remains minimum.
An experiment was conducted at the 0.3 m Transonic Cryogenic Tunnel using a Laser Transit Anemometer (LTA) to probe the flow field around a 3.05 centimeter-diameter circular cylinder. Measurements were made along the stagnation line and determination of particle size was evaluated by their ability to follow the flow field. The LTA system was also used to scan into the boundary layer near the 45 degree point on the model. Results of these scans are presented in graphic and tabular form. Flow field particle seeding was accomplished by inbleeding dry service air. The residual moisture (5-10 ppm) condensed and formed ice particles which served as Mie scattering centers for the LTA detection system. Comparison of data taken along the stagnation streamline with theory indicated that these particles tracked the velocity gradient of the flow. Tunnel operating conditions for the tests were a Mach number of 0.3, a pressure of 1.93 x 100000 n/m squared, and a temperature of 225 degrees K. Free stream Mach number and pressure were varied for the particle size determination.
Conventional methods for reducing the pulsed thermographic responses of delaminations tend to overestimate the size of the flaw. Since the heat diffuses in the plane parallel to the surface, the resulting temperature profile over the flaw is larger than the flaw. A variational method is presented for reducing the thermographic data to produce an estimated size for the flaw that is much closer to the true size of the flaw. The size is determined from the spatial thermal response of the exterior surface above the flaw and a constraint on the length of the contour surrounding the flaw. The technique is applied to experimental data acquired on a flat bottom hole composite specimen.
The purpose of this project was to use the cosmic ray data from the IMP, Voyager and Pioneer spacecraft in the heliosphere out to approximately 65 AU to estimate the size of the heliosphere. We used several techniques to develop a consistent picture of the size of the heliosphere. The first method used a response function approach which determined the intensity as a function of time by scaling the modulation effect as they move outward and eventually reach the boundary of the heliosphere. In this model the effects of transient cosmic ray disturbances is included. A second approach using the perturbation method in which drifts are considered as a perturbation to the standard diffusion-convection modulation models was not fully developed. In a third approach the location of the modulation boundary beyond the termination shock was estimated using observations of the intensity and radial gradients between Voyager 2 and Pioneer 10 along with new estimates of the interstellar intensity of more than 70 MeV galactic cosmic rays. Using this method we found that for 7 years, from 1983 to 1990, the modulation boundary remained constant at 83 +/- 5 AU. We infer from these studies that a modulation boundary can be estimated only by extrapolating the observed radial gradients when the solar magnetic field polarity is such that cosmic-ray particles are drifting in the heliosphere inward toward the Earth along the neutral sheet. The boundary distance is larger than the estimates of the location of the termination shock at 67 +/- 5 AU using the same method. Two other studies partially supported by this grant are attached. The first deals with the recovery period of the greater than 70 MeV cosmic rays in the outer heliosphere from 1992-1995. In the second paper we compare the rigidity dependence of the 11-year cosmic ray variation at the Earth in two cycles of opposite solar magnetic field polarity.
A unifying approach, based on a generalization of Pearson's differential equation of statistical theory, is proposed for both the representation of particulate size distribution and the interpretation of radiometric measurements in terms of this parameter. A single-parameter gamma-type distribution is introduced, and it is shown that inversion can only provide the dimensionless parameter, r/ab (where r = particle radius, a = effective radius, b = effective variance), at least when the distribution vanishes at both ends. The basic inversion problem in reconstructing the particle size distribution is analyzed, and the existing methods are reviewed (with emphasis on their capabilities) and classified. A two-step strategy is proposed for simultaneously determining the complex refractive index and reconstructing the size distribution of atmospheric particulates.