Search NASA⌕ Search

SEARCH · Search NASA

Results for “SLAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Calibration of the EGRET high-energy gamma-ray telescope in the range 20-10,000 MeV with a tunable beam of quasi-monoenergetic gamma rays at SLAC

The EGRET telescope, one of the instruments to be carried on NASA's Gamma Ray Observatory, is designed to explore the high-energy portion (20-24,000 MeV) of the electromagnetic spectrum. A calibration source of gamma-rays over this wide energy range has been used together with an appropriate set of intensity-monitoring instruments, to conduct a calibration of the EGRET telescope over this energy range for the full telescope aperture. The calibration method and an overview of the results are described.

Thompson, D. J.↗

The Sloan Lens ACS Survey. I. A Large Spectroscopically Selected Sample of Massive Early-Type Lens Galaxies

The Sloan Lens ACS (SLACS) Survey is an efficient Hubble Space Telescope (HST) Snapshot imaging survey for new galaxy-scale strong gravitational lenses. The targeted lens candidates are selected spectroscopically from the Sloan Digital Sky Survey (SDSS) database of galaxy spectra for having multiple nebular emission lines at a redshift significantly higher than that of the SDSS target galaxy. The SLACS survey is optimized to detect bright early-type lens galaxies with faint lensed sources in order to increase the sample of known gravitational lenses suitable for detailed lensing, photometric, and dynamical modeling. In this paper, the first in a series on the current results of our HST Cycle 13 imaging survey, we present a catalog of 19 newly discovered gravitational lenses, along with nine other observed candidate systems that are either possible lenses, nonlenses, or nondetections. The survey efficiency is thus >=68%. We also present Gemini 8 m and Magellan 6.5 m integral-field spectroscopic data for nine of the SLACS targets, which further support the lensing interpretation. A new method for the effective subtraction of foreground galaxy images to reveal faint background features is presented. We show that the SLACS lens galaxies have colors and ellipticities typical of the spectroscopic parent sample from which they are drawn (SDSS luminous red galaxies and quiescent MAIN sample galaxies), but are somewhat brighter and more centrally concentrated. Several explanations for the latter bias are suggested. The SLACS survey provides the first statistically significant and homogeneously selected sample of bright early-type lens galaxies, furnishing a powerful probe of the structure of early-type galaxies within the half-light radius. The high confirmation rate of lenses in the SLACS survey suggests consideration of spectroscopic lens discovery as an explicit science goal of future spectroscopic galaxy surveys.

galaxies↗

Electron showers of high primary energy in lead.

The development of electron cascade showers in a lead-scintillator sandwich of 8 plastic scintillators in about 20 radiation lengths of lead has been investigated. This detector, which was used for cosmic-ray studies, has been calibrated with electrons with energies from 2 to 15 GeV at SLAC. Measured shower profiles are presented, and expressions are given which allow an extrapolation of the measured data up to energies around 1000 GeV. The results are compared with analytical shower theories and Monte Carlo calculations.

Mueller, D.↗

The spectrum of galactic electrons with energies between 10 and 900 GeV

A cosmic-ray electron detector has been exposed during 1970 in three high-altitude balloon flights from Palestine, Texas. The data analysis is based on results from accelerator calibrations with electrons and pions at SLAC. Discrimination against a contamination of the electron data due to interacting protons has been achieved by statistical methods. The resulting differential energy spectrum of cosmic-ray electrons can be well described by a single power law with spectral index 2.66 plus or minus 0.1 up to energies around 250 GeV. Within the experimental uncertainty, no change in this spectral slope up to almost 1000 GeV can be detected. Some implications of these results are discussed.

Mueller, D.↗

Measurements of the spectrum of galactic electrons at very high energies

A counter telescope has been exposed in three balloon flights in 1970 to measure the flux and energy spectrum of cosmic ray electrons between 10 and 1000 GeV. This instrument has been modified by incorporating a large area CsI crystal as well as highly efficient time of flight circuitry, and was flown again twice during 1972. The methods of data analysis are based on extensive accelerator calibrations at SLAC. The resulting electron spectrum fits well to a single power law with an index (gamma) equal to 2.66 over the whole energy region. No obvious steepening can be observed, although statistical uncertainties prohibit definite claims beyond 250 GeV.

Mueller, D.↗

The efficient identification of relativistic particles by transition radiation

A system of transition radiation detectors has been constructed and exposed to beams of electrons and pions in the energy range of 3 to 15 GeV at SLAC. Transition radiation was generated in a variety of stacks of mylar foils (radiators), and its intensity was detected with 7 multiwire proportional chambers. The raw data demonstrate a good separation between electron and pion induced signals. A more detailed analysis shows that a very efficient identification of individual particles is possible. Typically, a detection efficiency for electrons above 90%, combined with a pion-electron discrimination ratio of .001, has been achieved. Some conclusions with respect to the design of a practical detector for relativistic particles are drawn.

Cherry, M. L.↗

Transition radiation from relativistic electrons in periodic radiators

The generation and detection of transition radiation have been studied in a series of experiments with electrons from 1 to 15 GeV at SLAC and at the Cornell Synchrotron. Periodic radiators, consisting of thin plastic foils stretched in air at constant spacings, were used, and proportional chambers filled with krypton or xenon served as detectors. A detailed discussion of the theoretical predictions is given, and the measurements are systematically compared with the predictions by varying the most critical parameters, such as configuration of radiators and detectors, and energy of the electrons. In general, good agreement between theory and experiment has been found. On the basis of these results, the criteria are summarized under which transition radiation can readily be observed.

Cherry, M. L.↗

Photo nuclear energy loss term for muon-nucleus interactions based on xi scaling model of QCD

Extensive air showers (EMC) experiments discovered a significant deviation of the ratio of structure functions of iron and deuteron from unity. It was established that the quark parton distribution in nuclei are different from the corresponding distribution in the nucleus. It was examined whether these results have an effect on the calculation of photo nucleus energy loss term for muon-nucleus nuclear interaction. Though the EMC and SLAC data were restricted to rather large q sq region it is expected that the derivation would persist even in the low q sq domain. For the ratio of iron and deuteron structure function a rather naive least square fit of the form R(x) = a + bx was taken and it is assumed that the formula is valid for the whole q sq region the absence of any knowledge of R(x) for small q sq.

Roychoudhury, R.↗

Spacelab Lyman Alpha-White Light Coronagraph Program

The Spacelab Lyman Alpha Coronagraph (SLAC) of the Smithsonian Astrophysical Observatory (SAO) and the White Light Coronagraph (WLC) to be provided by the High Altitude Observatory (HAO) are two separate coronagraphs which would be operated in a joint fashion during Spacelab missions to be flown by the Space Shuttle. The two instruments would be used to perform joint observations of solar coronal structures from 1.2 to 8.0 solar radii from sun-center in vacuum ultraviolet and visible radiations. Temperatures, densities, and flow velocities throughout the solar wing acceleration region of the inner solar corona were measured. The Phase I Definition activity resulted in the successful definition and preliminary design of the experiment/instrumentation subsystem and associated software, ground support equipment and interfaces to the extended required to accurately estimate the scope of the investigation and prepare an Investigational Development Plan; the performance of the necessary functional, operations, and safety analyses necessary to complete the Experiment Requirements document.

Kohl, J. L.↗

Plastic scintillator block as photon beam monitor for EGRET calibration

The EGRET (Energetic Gamma Ray Experiment Telescope) detector has been calibrated at SLAC (Stanford Linear Accelerator) and, to a lesser degree, at the MIT Bates Linear Accelerator Center. To monitor the photon beams for the calibration, a plastic scintillator block, 5 cm x 5 cm in cross section, 15 cm in length, and viewed by a single photomultiplier tube, was used for the entire beam energy range of 15 MeV to 10 GeV. The design operation, and method of analysis of the beam intensity are presented. A mathematical framework has been developed to treat the general case of a beam with multiphoton beam pulses and with a background component. A procedure to deal with the fluctuations of the beam intensity over a data-taking period was also developed. The photon beam monitor is physically sturdy, electronically steady, simple to construct, and easy to operate. Its major merits lie in its sheer simplicity of construction and operation and in the wide energy range it can cover.

Lin, Y. C.↗

Studying the High Energy Gamma Ray Sky with Gamma Ray Large Area Space Telescope (GLAST)

Building on the success of the Energetic Gamma Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory, the Gamma Ray Large Area Space Telescope (GLAST) will make a major step in the study of such subjects as blazars, gamma Ray bursts, the search for dark matter, supernova remnants, pulsars, diffuse radiation, and unidentified high energy sources. The instrument will be built on new and mature detector technologies such as silicon strip detectors, low-power low-noise LSI, and a multilevel data acquisition system. GLAST is in the research and development phase, and one full tower (of 25 total) is now being built in collaborating institutes. The prototype tower will be tested thoroughly at Stanford Linear Accelerator Center (SLAC) in the fall of 1999.

Kamae, T.↗

Ordering Unstructured Meshes for Sparse Matrix Computations on Leading Parallel Systems

The ability of computers to solve hitherto intractable problems and simulate complex processes using mathematical models makes them an indispensable part of modern science and engineering. Computer simulations of large-scale realistic applications usually require solving a set of non-linear partial differential equations (PDES) over a finite region. For example, one thrust area in the DOE Grand Challenge projects is to design future accelerators such as the SpaHation Neutron Source (SNS). Our colleagues at SLAC need to model complex RFQ cavities with large aspect ratios. Unstructured grids are currently used to resolve the small features in a large computational domain; dynamic mesh adaptation will be added in the future for additional efficiency. The PDEs for electromagnetics are discretized by the FEM method, which leads to a generalized eigenvalue problem Kx = AMx, where K and M are the stiffness and mass matrices, and are very sparse. In a typical cavity model, the number of degrees of freedom is about one million. For such large eigenproblems, direct solution techniques quickly reach the memory limits. Instead, the most widely-used methods are Krylov subspace methods, such as Lanczos or Jacobi-Davidson. In all the Krylov-based algorithms, sparse matrix-vector multiplication (SPMV) must be performed repeatedly. Therefore, the efficiency of SPMV usually determines the eigensolver speed. SPMV is also one of the most heavily used kernels in large-scale numerical simulations.

Oliker, Leonid↗

Robust Extraction and Multi-Technique Analysis of Micrometeoroids Captured in Low Earth Orbit

The use of low-density silica aerogel as the primary capture cell technology for the NASA Discovery mission Stardust to Comet Wild-2 [1] is a strong motivation for researchers within the Meteoritics community to develop techniques to handle this material. The unique properties of silica aerogel allow dust particles to be captured at hypervelocity speeds and to remain partially intact. The same unique properties present difficulties in the preparation of particles for analysis. Using tools borrowed from microbiologists, we have developed techniques for robustly extracting captured hypervelocity dust particles and their residues from aerogel collectors[2-3]. It is important not only to refine these extraction techniques but also to develop protocols for analyzing the captured particles. Since Stardust does not return material to Earth until 2006, researchers must either analyze particles that are impacted in the laboratory using light-gasgun facilities [e.g. 41 or examine aerogel collectors that have been exposed in low-Earth orbit (LEO) [5]. While there are certainly benefits in laboratory shots, i.e. accelerating known compositions of projectiles into aerogel, the LEO capture particles offer the opportunity to investigate real particles captured under real conditions. The aerogel collectors used in this research are part of the NASA Orbital Debris Collection Experiment that was exposed on the MIR Space Station for 18 months [5]. We have developed the capability at the UCB Space Sciences Laboratory to extract tiny volumes of aerogel that completely contain each impact event, and to mount them on micromachined fixtures so that they can be analyzed with no interfering support (Fig.1). These aerogel keystones simultaneously bring the terminal particle and the particle track to within 10 m (15 g cm- ) of the nearest aerogel surface. The extracted aerogel wedges containing both the impact tracks and the captured particles have been characterized using the synchrotron total external reflection X-ray fluorescence (TXRF) microprobe at SSRL, the Nuclear Microprobe at LLNL, synchrotron infrared microscopy at the ALS facility at LBL and the NSLS at BNL, and the Total Reflection X-ray Fluorescence (TXRF) facility at SLAC.

Westphal, A. J.↗

GEANT4 and Secondary Particle Production

GEANT 4 is a Monte Carlo tool set developed by the High Energy Physics Community (CERN, SLAC, etc) to perform simulations of complex particle detectors. GEANT4 is the ideal tool to study radiation transport and should be applied to space environments and the complex geometries of modern day spacecraft.

radiation transport↗

Put X-Ray Polarimetry on the MAP!

With Prof. R. Novick and others at the Columbia Astrophysics Laboratory I help found the field of X-ray polarimetry in the early 1970s. Currently I have more experience with the design, construction, calibration, and space flight of such instruments than anyone on the planet. The early probing beginnings saw only one definitive measurement (that of the integrated low-energy X-ray emission from the Crab Nebula sans pulsar) and a number of upper limits. The limited success did nevertheless inspire a number of detailed theoretical calculations, concentrating at first on neutron stars and black holes showing how precise measurements (e.g. degree of polarization and position angle as a function of pulse phase) would provide definitive limitations on otherwise equally plausible theoretical models. Over time the theoretical foundation has grown (e.g. the proceedings of the X-Ray Polarimetry Workshop held at SLAC in 2004). I will outline these foundations. It is important to understand the history of X-ray polarimetry beyond the early excitement. A polarimeter was at the focus of the original Einstein mission but was dropped during the restructuring. A polarimeter was successfully proposed (R. Novick PI, I was a Co-I) and built for the original Spectrum-X mission. During the years before the cancellation of Spectrum-X, the potential flight of this device stood in the way of other space flights for polarimeters --- "let us wait and see what it finds". This was unfortunate as there were a number of reasons why that polarimeter should not have been flown on the mission. Perhaps the most significant (but not only) reason was that a shared focal plane provided very little observing time. This is an extremely important point in considering the Roadmap. It is doubtful that there many 100%-polarized sources and so the "signal" is more typically a small fraction of the source flux. Thus, the source itself provides a substantial background, making continuum polarimetry even more difficult than narrow-line spectroscopy. X-ray polarimetry thus requires a dedicated mission that can, without programmatic pressures from other instruments/users, devote the integration time to perform meaningful measurements. The recently cancelled GEMS might have been such a mission. At least it was dedicated to polarimetry. Performing meaningful measurements is not going to be easy. In part because of the long hiatus and lack of experience, there appears to be too much pressure to "sell" polarimetry missions by the number of sources for which one might answer the simple question is, or is not, the integrated and time averaged emission from the source polarized at some confidence level? This was a fine question for the 1970 s but, I maintain, it is not today. One simply doesn't want to measure the time averaged polarization of the Crab s pulsar, but one wants to know the polarization as a function of energy and pulse phase to compare, e.g. to optical and radio measurements which divide even the primary pulse into dozens of phase bins. Such observations can distinguish amongst competing theories for the pulsed emission. The Roadmap should define what meaningful experiments are. I will pose some suggestions. Note that , because X-rays are usually believed originate in either non-thermal or highly aspherical situations we expect X-ray polarimetry to be much more important and rich in astrophysical information as opposed to the visible, where starlight often dominates the emission. One has often dreamt about an instrument that does polarimetry whilst it does other things, and I will discuss this. Even in this case, one needs to realize that the observing time will be driven by the polarimetry, otherwise no useful polarization measurements will be made. Finally, I will discuss some misconceptions that have appeared in the literature and at conferences which indicate to me that certain fundamental principles of polarimeter design and performance are not clearly understoodt is important for the Roadmap that we understand these principles and not advocate instruments that will not (or even worse cannot) accomplish the promised scientific return. I will discuss these principles.

Weisskopf, Martin C.↗

The Mapping X-Ray Fluorescence Spectrometer (MAPX)

MapX will provide elemental imaging at ≤100 micron spatial resolution over 2.5 X 2.5 centimeter areas, yielding elemental chemistry at or below the scale length where many relict physical, chemical, and biological features can be imaged and interpreted in ancient rocks. MapX is a full-frame spectroscopic imager positioned on soil or regolith with touch sensors. During an analysis, an X-ray source (tube or radioisotope) bombards the sample surface with X-rays or αlpha-particles / gamma rays, resulting in sample X-ray Fluorescence (XRF). Fluoresced X-rays pass through an X-ray lens (X-ray μ-Pore Optic, "MPO") that projects a spatially resolved image of the X-rays onto a CCD. The CCD is operated in single photon counting mode so that the positions and energies of individual photons are retained. In a single analysis, several thousand frames are stored and processed. A MapX experiment provides elemental maps having a spatial resolution of ≤100 micron and quantitative XRF spectra from Regions of Interest (ROI) 2 centimers ≤ x ≤ 100 micron. ROI are compared with known rock and mineral compositions to extrapolate the data to rock types and putative mineralogies. The MapX geometry is being refined with ray-tracing simulations and with synchrotron experiments at SLAC. Source requirements are being determined through Monte Carlo modeling and experiment using XMIMSIM [1], GEANT4 [2] and PyMca [3] and a dedicated XRF test fixture. A flow-down of requirements for both tube and radioisotope sources is being developed from these experiments. In addition to Mars lander and rover missions, MapX could be used for landed science on other airless bodies (Phobos/Deimos, Comet nucleus, asteroids, the Earth's moon, and the icy satellites of the outer planets, including Europa.

Blake, David↗

Conceptual Design of an Experiment to Study Dust Destruction by Astrophysical Shock Waves

A novel laboratory experimental design is described that will investigate the processing of dust grains in astrophysical shocks. Dust is a ubiquitous ingredient in the interstellar medium (ISM) of galaxies; however, its evolutionary cycle is still poorly understood. Especially shrouded in mystery is the efficiency of grain destruction by astrophysical shocks generated by expanding supernova remnants. While the evolution of these remnants is fairly well understood, the grain destruction efficiency in these shocks is largely unknown. The experiments described herein will fill this knowledge gap by studying the dust destruction efficiencies for shock velocities in the range of approximately 10-30 kilometers per second (microns per nanosecond), at which most of the grain destruction and processing in the ISM takes place. The experiments focus on the study of grain-grain collisions by accelerating small (1 millimeter) dust particles into a large (approximately 5-10 millimeter diameter) population; this simulates the astrophysical system well in that the more numerous, small grains impact and collide with the large population. Facilities that combine the versatility of high-power optical lasers with the diagnostic capabilities of X-ray free-electron lasers, e.g., the Matter in Extreme Conditions instrument at the SLAC (originally named Stanford Linear Accelerator Center) National Accelerator Laboratory, provide an ideal laboratory environment to create and diagnose dust destruction by astrophysically relevant shocks at the micron scale.

Manuel, M. J.-E.↗