Search NASA⌕ Search

SEARCH · Search NASA

Results for “SLIM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cyclable Variable Path Length Multilevel Structures for Lossless Ion Manipulations (SLIM) Platform for Enhanced Ion Mobility Separations

Ion mobility-mass spectrometry (IMS-MS) is increasingly used to analyze complex samples and provide structural information of unknown compounds. As the complexity of samples increases, there is a need to improve the resolution of IMS-MS instruments to increase the rate of molecular identification. In this work, we evaluated a cyclable and variable-pathlength multilevel Structures for Lossless Ion Manipulations (SLIM) platform to achieve a higher resolving power than previously possible. This new multilevel SLIM platform has eight separation levels connected by ion escalators and a path length of ~88 meters (~11 meters per level). Our new multilevel SLIM can also be operated in an ‘ion cycling’ mode where a set of return ion escalators transport ions from the eighth back to the first level, allowing even longer path lengths (and higher IMS resolution). The platform has been improved to enhance the ion transmission and IMS separation quality by reducing the spacing between SLIM boards as well as board thickness, reducing the ions’ escalator residence time. Compared to the previous generation, the new multilevel SLIM demonstrated a better transmission for a set of phosphazene ions, especially for the low-mobility ions. The new multilevel SLIM achieved better resolving powers than our previous 4-level SLIM. The collision cross-section-based resolving power of the SLIM platform was tested using a pair of singly-charged reverse sequence peptides (SDGRG 1+ , GRGDS 1+ ). We achieved 1100 resolving power using 88 meters of path length (i.e., 8 levels) and 1400 following an additional pass through the eight levels (i.e., 16 levels or 173.5 m). The multilevel SLIM was further evaluated to demonstrate the enhanced separation for a positively and negatively charged brain total lipid extract sample. Finally, the new multilevel SLIM enables much higher resolving powers for a wide range of ion mobilities, improved transmission for low-mobility ions, and the ability to perform even higher resolving power for ions of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accumulation of Large Ion Populations with High Ion Densities and Effects Due to Space Charge in Traveling Wave-Based Structures for Lossless Ion Manipulations (SLIM) IMS-MS

The accumulation of very large ion populations in traveling wave (TW)-based Structures for Lossless ion Manipulations (SLIM) has been studied to better understand aspects of ‘in-SLIM’ ion accumulation, and particularly its use in conjunction with ion mobility spectrometry (IMS). A linear SLIM ion path was implemented that had a ‘gate’ for blocking and accumulating ions for arbitrary time periods. Removing the gate potential caused ions to exit and the spatial distributions of accumulated ions were examined. The ion populations for a set of peptides were observed to increase with increased accumulation times until space change effects became significant, after which the peptide precursor ion populations decreased due to growing space charge-related ion activation, reactions, and losses. Ions closest to the gate were preferentially activated, and increasingly so with added storage times, TW amplitude, and the size of the total ion population. For analytical applications, we found that relatively weak TWs in the accumulation/storage region should be utilized to prevent or minimize ion losses and/or ion heating effects that can also lead to fragmentation. Our results further indicate that an accumulation region close to the SLIM entrance is advantageous for both speeding accumulation, minimizing ion heating, and avoiding ion population profiles that result in IMS peak tailing. Importantly, space charge-driven separations were observed for large populations of accumulated species and attributed to the opposing effects of space charge and the TW. In these separations, ion species form distributions or peaks, sometimes moving against the TW, and ordered in the SLIM based on their mobilities. Such separations may offer utility for ion pre-fractionation of ions and increasing the dynamic range measurements, increasing the resolving power of IMS separations by decreasing peak widths for accumulated ion populations, and other purposes benefitting from separations of extremely large ion populations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An On-Sky Atmospheric Calibration of SPT-SLIM

We present the methodology and results of the on-sky responsivity calibration of the South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM). SPT-SLIM is a pathfinder line intensity mapping experiment utilizing the on-chip spectrometer technology, and was first deployed during the 2024-2025 Austral Summer season on the South Pole Telescope. During the two-week on-sky operation of SPT-SLIM, we performed periodic measurements of the detector response as a function of the telescope elevation angle. Combining these data with atmospheric opacity measurements from an on-site atmospheric tipping radiometer, simulated South Pole atmospheric spectra, and measured detector spectral responses, we construct estimates for the responsivity of SPT-SLIM detectors to sky loading. We then use this model to calibrate observations of the moon taken by SPT-SLIM, cross-checking the result against the known brightness temperature of the Moon as a function of its phase.

Dibert, K. R. [Chicago U., Astron. Astrophys. Ctr.↗

Spectral characterization and performance of SPT-SLIM on-chip filterbank spectrometers

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) experiment is a pathfinder for demonstrating the use of on-chip spectrometers for millimeter (mm) Line Intensity Mapping (LIM). We present spectral bandpass measurements of the SPT-SLIM spectrometer channels made on site using a Fourier Transform Spectrometer during the first deployment of SPT-SLIM in the 2024-2025 Austral summer season. We note the effect of FTS systematics on measurements of on-chip filterbank spectrometer resolutions and demonstrate a technique for measuring the narrow band passes of the SPT-SLIM filterbanks that improves beyond the intrinsic resolution of a Fourier Transform Spectrometer.

Benson, C. S. [Cardiff U.]↗

SPT-SLIM: Line Intensity Mapping with the South Pole Telescope

Line-intensity mapping (LIM) at millimeter wavelengths is a powerful emerging probe of the large-scale structure of the Universe, but achieving meaningful constraints on cosmological parameters with LIM requires focal planes with orders of magnitudes more detectors than existing instruments. SPT-SLIM is an upcoming experiment to demonstrate LIM observations of CO at 0.5 < z < 2.0 using on-chip spectrometers with kinetic inductance detectors (KIDs), a new technology that enables scaling to the much larger arrays of detectors needed to probe cosmology. I will describe the overall experimental design and specific goals of SPT-SLIM. In addition, I will highlight results of the detector and readout electronics development for SPT-SLIM and the status of the camera integration and commissioning in the lab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cryogenic Performance of the SPT-SLIM Receiver

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wave line-intensity mapping experiment, deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral Summer season. This pathfinder experiment serves to demonstrate the on-sky operation of multi-pixel on-chip spectrometer technology. We present on the cryogenic performance of the SPT-SLIM receiver for this Year 1 observing campaign. The SPT-SLIM receiver utilizes an Adiabatic Demagnetization Referigerator (ADR) for cooling the focal plane of superconducting filterbank spectrometers to a temperature of 150mK. We demonstrate stable thermal performance of the focal plane module during observing operations in line with thermal modelling, enabling a cryogenic operation efficiency above 80%. We also report on the receiver control system design utilizing the Observatory Control System (OCS) platform for automated cryogenic operation on the SPT.

Young, Matthew [Fermilab]↗

Design and Performance of the SPT-SLIM Receiver Cryostat

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wavelength line-intensity mapping experiment, which was deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral summer season. This pathfinder experiment serves to demonstrate the on-sky operation of multi-pixel on-chip spectrometer technology. We report on the cryogenic performance of the SPT-SLIM receiver for the first year of commissioning observations. The SPT-SLIM receiver utilizes an Adiabatic Demagnetization Refrigerator (ADR) for cooling the focal plane of superconducting filterbank spectrometers to a temperature of 150 mK. We demonstrate stable thermal performance of the focal plane module during observations consistent with thermal modeling, enabling a cryogenic operating efficiency above 80%. We also report on the receiver control system design utilizing the Observatory Control System (OCS) platform for automated cryogenic operation on the SPT.

Young, M. R. [Fermilab; Chicago U., KICP]↗

Evaluating the performance of a high resolution SLIM IM module integrated with an Agilent 6560 IM-QTOF MS

Integrate a combined Structures of Lossless Ion Manipulations (SLIM) module that incorporates both constant (not time-varying) field (CF) and oscillatory (time-varying) field (OF) IM separation stages into an Agilent 6560 IM-QTOF mass spectrometer system. Once the SLIM module has been integrated into the Agilent system, its performance will be evaluated using a variety of different samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPT-SLIM: Line-Intensity Mapping Pathfinder on the South Pole Telescope

The Shirokoff Line-Intensity Mapper (SPT-SLIM) is a mm-wavelength, superconducting on-chip spectrometer observing redshifted CO in the 2mm atmospheric window using the 10-meter South Pole Telescope (SPT). The instrument was recently deployed for the first time during the 2024-2025 austral summer season at South Pole, where it conducted a short two-week observing campaign. We will present an overview of the SPT-SLIM instrument and project, discuss early results from its initial deployment, and preview the prospects for a longer survey using upgraded instrumentation in the 2025-2026 austral summer.

Anderson, Adam [Fermilab; Chicago U.]↗

Evaluation of a Reference-Free Collision Cross Section Calibration Strategy for Proteomics Using SLIM-Based High-Resolution Ion Mobility Spectrometry–Mass Spectrometry

Ion mobility spectrometry (IMS) is a gas-phase analytical technique that separates ions with different sizes and shapes and is compatible with mass spectrometry (MS) to provide an additional separation dimension. The rapid nature of the IMS separation combined with the high sensitivity of MS-based detection and the ability to derive structural information on analytes in the form of the property collision cross section (CCS) makes IMS particularly well-suited for characterizing complex samples in -omics applications. In such applications, the quality of CCS from IMS measurements is critical to confident annotation of the detected components in the complex -omics samples. However, most IMS instrumentation in mainstream use requires calibration to calculate CCS from measured arrival times, with the most notable exception being drift tube IMS measurements using multifield methods. The strategy for calibrating CCS values, particularly selection of appropriate calibrants, has important implications for CCS accuracy, reproducibility, and transferability between laboratories. The conventional approach to CCS calibration involves explicitly defining calibrants ahead of data acquisition and crucially relies upon availability of reference CCS values. In this work, we present a novel reference-free approach to CCS calibration which leverages trends among putatively identified features and computational CCS prediction to conduct calibrations post-data acquisition and without relying on explicitly defined calibrants. We demonstrated the utility of this reference-free CCS calibration strategy for proteomics application using high-resolution structures for lossless ion manipulations (SLIM)-based IMS-MS. In conclusion, we first validated the accuracy of CCS values using a set of synthetic peptides and then demonstrated using a complex peptide sample from cell lysate.

59 BASIC BIOLOGICAL SCIENCES↗

2023 T120 Horizon and Slim Posthole Seismometer Exploratory Evaluation

Sandia National Laboratories has tested and evaluated a suite of four T120 broadband seismometers designed and manufactured by Nanometrics. Specifically, two T120 Horizon V2 sensors, one T120 Horizon V1 sensor and one T120 Slim Posthole (PH) sensor were evaluated. The purpose of this seismometer evaluation is to measure performance characteristics in areas such as power consumption, sensitivity, frequency response, full scale, self-noise, dynamic range, calibration system response, and passband. The T120 model of sensors are being evaluated to explore the potential for a future seismometer Type Approval process in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT).

47 OTHER INSTRUMENTATION↗

Evaluating Ion Accumulation and Storage in Traveling Wave Based Structures for Lossless Ion Manipulations

Structures for lossless ion manipulations (SLIM) technology has demonstrated high resolving power ion mobility separation and flexibility to integrate complex ion manipulations into a single experimental platform. To enable IMS separations, trapping/accumulating ions inside SLIM (or in-SLIM) prior to injection of a packet for separations provides ease of operation and reduces the need for dedicated ion traps external to SLIM. To fully characterize the ion accumulation process, we have evaluated the effect of TW amplitudes, ion collection times, and storage times on the “in-SLIM” accumulation process. The study utilized a SLIM module comprising 5 distinct tracks, each with a specific ion accumulation configuration. The effect of the TW conditions on the accumulation process was investigated for a 3-peptide mixture: kemptide, angiotensin II, and neurotensin at a TW speed of 106 m/s. The effect of ion accumulation time/collection time and storage time was investigated, in addition to TW amplitude. Overall, the signal of the analyte ions increased when the ion collection time increased from 49 to 163 ms but decreased when the ion collection time increased further to 652 ms due to the space charge effects. Ion losses were observed at high TW amplitudes (e.g., 15 V p–p and 20 V p–p ). In addition, under space charge conditions (e.g., collection times of 163 and 652 ms), the signal of the analyte ions decreased with an increase in storage times for all TW amplitudes applied to the trapping region. For ion accumulation, the data indicate that gentler TW conditions must be utilized to minimize ion losses and fragments to benefit from the “in-SLIM” accumulation process. Finally, wider SLIM tracks provided better performance than those with narrower tracks.

59 BASIC BIOLOGICAL SCIENCES↗

High-resolution ion mobility based on traveling wave structures for lossless ion manipulation resolves hidden lipid features

Abstract High-resolution ion mobility (resolving power > 200) coupled with mass spectrometry (MS) is a powerful analytical tool for resolving isobars and isomers in complex samples. High-resolution ion mobility is capable of discerning additional structurally distinct features, which are not observed with conventional resolving power ion mobility (IM, resolving power ~ 50) techniques such as traveling wave IM and drift tube ion mobility (DTIM). DTIM in particular is considered to be the “gold standard” IM technique since collision cross section (CCS) values are directly obtained through a first-principles relationship, whereas traveling wave IM techniques require an additional calibration strategy to determine accurate CCS values. In this study, we aim to evaluate the separation capabilities of a traveling wave ion mobility structures for lossless ion manipulation platform integrated with mass spectrometry analysis (SLIM IM-MS) for both lipid isomer standards and complex lipid samples. A cross-platform investigation of seven subclass-specific lipid extracts examined by both DTIM-MS and SLIM IM-MS showed additional features were observed for all lipid extracts when examined under high resolving power IM conditions, with the number of CCS-aligned features that resolve into additional peaks from DTIM-MS to SLIM IM-MS analysis varying between 5 and 50%, depending on the specific lipid sub-class investigated. Lipid CCS values are obtained from SLIM IM ( TW(SLIM) CCS) through a two-step calibration procedure to align these measurements to within 2% average bias to reference values obtained via DTIM ( DT CCS). A total of 225 lipid features from seven lipid extracts are subsequently identified in the high resolving power IM analysis by a combination of accurate mass-to-charge, CCS, retention time, and linear mobility-mass correlations to curate a high-resolution IM lipid structural atlas. These results emphasize the high isomeric complexity present in lipidomic samples and underscore the need for multiple analytical stages of separation operated at high resolution. Graphical abstract

Reardon, Allison R. (ORCID:0000000165830134)↗

Characterization of Gas-Phase Native(-like) Proteins Using Structures for Lossless Ion Manipulations

High-resolution mobility-based ion separations in Structures for Lossless Ion Manipulations (SLIM) have been useful for ion mobility separations for a variety of molecular classes in the gas phase. Here, in this study, we present multipass SLIM separations for gas-phase proteins in their near-native state exhibiting charge-state-dependent arrival time distributions using carbonic anhydrase (29 kDa), alcohol dehydrogenase (148 kDa), and apo-transferrin (79 kDa). The experimental CCS values were obtained from calibration curves for the arrival times of Agilent Tune Mix ions. For multipass separations, the ATDs were converted to CCS values by deconvoluting the multipass arrival times into accurate single-pass values amenable to the single-pass calibration curves. Mass spectra of carbonic anhydrase (CA) showed three different charge states (z = 9+ to 11+). Their corresponding mobility peaks were baseline-separated by using 8-m single-pass separations. When compared to the corresponding drift tube ion mobility (DTIMS) measurements, the CCS values obtained from DTIMS and SLIM were in agreement within experimental error. Single-pass analysis of alcohol dehydrogenase (ADH) exhibits three predominant charge states (z = 23+ to 25+) with mobility overlap between adjacent charge states. The mobility peak resolution for ADH improved with multipass separations (up to 24-m path length). In addition, CCS distributions obtained for charge states z = 16+ to 18+ of apo-transferrin reveal a transition from a compact unimodal form (z = 18+ and 19+) to broader multimodal CCS distributions for z = 16+. For apo-transferrin, 40-m multipass separations were performed allowing for complete isolation of the selected mobility range corresponding to z = 17+, leading to selective isolation of a narrow arrival time window. The extended mobility separations provided minimal alterations to the structure of the proteins, and the experimentally derived CCS values showed minimal change as a function of the separation time or number of passes. Mobility-based ion separations for native-like proteins, using SLIM, open opportunities for native-IMS applications as well as other manipulations enabled by SLIM-like mobility-selective isolation and collection.

charge state distribution↗

Allosteric control of dynamin-related protein 1 through a disordered C-terminal Short Linear Motif

Abstract The mechanochemical GTPase dynamin-related protein 1 (Drp1) catalyzes mitochondrial and peroxisomal fission, but the regulatory mechanisms remain ambiguous. Here we find that a conserved, intrinsically disordered, six-residue Short Linear Motif at the extreme Drp1 C-terminus, named CT-SLiM, constitutes a critical allosteric site that controls Drp1 structure and function in vitro and in vivo. Extension of the CT-SLiM by non-native residues, or its interaction with the protein partner GIPC-1, constrains Drp1 subunit conformational dynamics, alters self-assembly properties, and limits cooperative GTP hydrolysis, surprisingly leading to the fission of model membranes in vitro. In vivo, the involvement of the native CT-SLiM is critical for productive mitochondrial and peroxisomal fission, as both deletion and non-native extension of the CT-SLiM severely impair their progression. Thus, contrary to prevailing models, Drp1-catalyzed membrane fission relies on allosteric communication mediated by the CT-SLiM, deceleration of GTPase activity, and coupled changes in subunit architecture and assembly-disassembly dynamics.

Science & Technology - Other Topics↗

Mobility Selective Ion Soft-Landing and Characterization Enabled Using Structures for Lossless Ion Manipulation

In this study, while conventional ion-soft landing uses the mass-to-charge (m/z) ratio to achieve molecular selection for deposition, here we demonstrate the use of Structures for Lossless Ion Manipulation (SLIM) for mobility-based ion selection and deposition. The dynamic rerouting capabilities of SLIM were leveraged to enable the rerouting of a selected range of mobilities to a different SLIM path (rather than MS) that terminated at a deposition surface. A selected mobility range from a phosphazene ion mixture was rerouted and deposited with a current pulse (~150 pA) resembling its mobility peak. In addition, from a mixture of tetra-alkyl ammonium (TAA) ions containing chain lengths of C5–C8, selected chains (C6, C7) were collected on a surface, reconstituted into solution-phase, and subsequently analyzed with a SLIM-qToF to obtain an IMS/MS spectrum, confirming the identity of the selected species. Further, this method was used to characterize triply charged tungsten-polyoxometalate anions, PW 12 O 40 3– (WPOM). The arrival time distribution of the IMS/MS showed multiple peaks associated with the triply charged anion (PW 12 O 40 3– ), of which a selected ATD was deposited and imaged using TEM. Additionally, the identity of the deposited WPOM was ascertained using energy-dispersive (EDS) spectroscopy. Further, we present theory and computations that reveal ion landing energies, the ability to modulate the energies, and deposition spot sizes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Platform for High-Resolution Ion Mobility Separations Coupled with Messenger Tagging Infrared Spectroscopy for High-Precision Structural Characterizations

The ability to uniquely identify a compound requires highly precise and orthogonal measurements. Here we describe a newly developed analytical platform that integrates high resolution ion mobility and cryogenic vibrational ion spectroscopy for high-precision structural characterizations. This platform allows for the temporal separation of isomeric/isobaric ions and provides a highly sensitive description of the ion’s adopted geometry in the gas phase. The combination of these orthogonal structural measurements yields precise descriptors that can be used to resolve between and confidently identify highly similar ions. The unique benefits of our instrument, which integrates a structures for lossless ion manipulations ion mobility (SLIM IM) device with messenger tagging infrared spectroscopy, include the ability to perform high-resolution ion mobility separations and to record the IR spectra of all ions simultaneously. The SLIM IM device, with its 13 m separation path length, allows for multipass experiments to be performed for increased resolution as needed. It is integrated with an Agilent qTOF MS where the collision cell was replaced with a cryogenically held (30 K) TW-SLIM module. The cryo-SLIM is operated in a novel manner that allows ions to be streamed through the device and collisionally cooled to a temperature where they can form noncovalently bound N 2 complexes that are maintained as they exit the device and are detected by the TOF mass analyzer. The instrument can be operated in two modes: IMS+IR where the IR spectra for mobility-selected ions can be recorded and IR-only mode where the IR spectra for all mass-resolved ions can be recorded. In IR-only mode, IR spectra (400 cm –1 spectral range) can be recorded in as short as 2 s for high throughput measurements. Further, this work details the construction of the instrument and modes of operation. It provides initial benchmarking of CCS and IR measurements to demonstrate the utility of this instrument for targeted and untargeted approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing the Range and Reliability of the Spacer Layer Imaging Method

The spacer layer imaging method (SLIM) is widely used to measure the thickness of additive and lubricant films, in lubricant development and evaluation, and for fundamental research into elastohydrodynamic lubrication and tribofilm formation mechanisms. The film thickness measurement, as implemented on several popular tribometers, provides powerful, non-destructive in-situ mapping of film topography with nanometre-scale height sensitivity. However, the results can be highly sensitive to experimental procedure, machine condition, and image analysis, in some cases reporting unphysical film thickness trends. The prevailing image analysis techniques make it challenging to interrogate these errors, often hiding their multivariate nonlinear behaviour from the user by spatial averaging. Herein, several common ‘silent errors’ in the SLIM measurement, including colour matching to incorrect fringe orders, and colour drift due to the optical properties of the system or film itself, are discussed, with examples. A robust suite of novel a priori and a posteriori methods to address these issues, and to improve the accuracy and reliability of the measurement, are also presented, including a novel, computationally inexpensive circle-finding algorithm for automated image processing. In combination, these methods allow reliable mapping of films up to at least 800 nm in thickness, representing a significant milestone for the utility of SLIM applied to elastohydrodynamic contact.

EHL film geometry↗