Search NASASearch

SEARCH · Search NASA

Results for “SMART 2.0”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Raw Lidar and Camera Data Synchronized with Precipitation and Present Weather Data

As part of the sensor characterization task of the SMART 2.0 project, this dataset includes raw data from three spinning lidars ([Ouster OS2-128](https://ouster.com/products/scanning-lidar/os2-sensor/), [Velodyne Puck (VLP-16)](https://velodynelidar.com/products/puck/), and [Velodyne Ultra Puck (VLP-32)](https://velodynelidar.com/products/ultra-puck/)), one camera ([Mako G-319](https://www.alliedvision.com/en/camera-selector/detail/mako/g-319/)), and one present weather sensor ([Vaisala FD-70](https://www.vaisala.com/en/products/weather-environmental-sensors/forward-scatter-fd70)). All data were synchronized, with the log start time indicated in the file name (HHMMSS). The data can be filtered by date, log time (HHMMSS), sensor, frame ID, and weather classification. These data were gathered statically at the Argonne Testbed for Multiscale Observational Science (ATMOS). Two target stop signs were placed in view of the sensors to contribute a target for comparing sensor data under different conditions. The weather data for each day are stored in netCDF “.nc” files. The lidar data contain the X, Y, Z, intensity, reflectivity, and ring from Ouster OS2-128 rev6, Velodyne VLP-16, and Velodyne VLP-32 lidars. ![raw lidar image](LiDAR_pointcloud_ATMOS.png)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Energy Efficient Mobility Systems (2023 Annual Progress Report)

This document summarizes the progress of VTO Energy Efficient Mobility Systems projects supported during the fiscal year 2023. DOE conducts research to understand how the changing mobility landscape will affect transportation energy consumption and identifies opportunities to create more efficient, affordable, reliable, accessible, equitable, and secure transportation options that enhance mobility for individuals and businesses. Within EERE, the EEMS Program is responsible for this research portfolio. This APR describes work that the EEMS Program conducted during FY 2023 in support of the EEMS Program goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Sensos Smart Label Performance Summary as Observed by Oak Ridge National Laboratory

The Oak Ridge National Laboratory (ORNL) team performed an evaluation of the Sensos Smart Label Gen 2.0, as shown in Figure 1, for package tracking. A long-distance round-trip shipment between Oak Ridge, Tennessee, and Seattle, Washington, was completed to assess the device’s performance in location tracking, environment sensing capabilities, alerting features, threshold options, battery life, and real-time and historical data retrieval from the “Sync” data dashboard provided by Sensos. The evaluation was conducted to gain a general understanding of the capabilities of the device. Furthermore, due to time and resource constraints, ORNL did not conduct exhaustive testing to confirm reliability, availability, or effectiveness of alerting and tracking features. On equipment arrangement, Sensos (sensos.ai) graciously agreed to provide a Sensos Smart Label Gen 2.0 device to ORNL, at no cost, for testing and evaluation purposes. ORNL conducted assessments along with other commercial off-the-shelf (COTS) tracking devices. As a courtesy, ORNL will provide Sensos with this report summarizing the observations and findings specific to the Sensos label based on the tests performed.

42 ENGINEERING

Equitable Strategies for Residential Building Energy Efficiency and Electrification in San José, California

Hotter summers, heat waves, wildfires, and droughts are already affecting San Jose residents, with historically marginalized communities impacted first and worst. The City of San Jose has ambitious goals to make the city climate-neutral by 2030 and serve as an example for cities to accelerate climate action around the world. Electrifying and decarbonizing residential buildings are important priorities to achieve San Jose's plans to reach carbon neutrality while enabling residents to live the "Good Life 2.0" - a vision that aligns with community-identified priorities of safety, health, freedom, community, and positive experiences. This technical assistance built upon the Electrify San Jose: Framework for Existing Building Electrification to identify actionable strategies to make single- and multi-family buildings both energy-efficient and all-electric. This report is intended to provide the San Jose Climate Smart team and their partners with relevant data, insights, and actionable analysis to aid in-depth and nuanced engagements with key stakeholders. In particular, the findings in this report highlight opportunities and challenges for San Jose City Council, residents, building owners, developers, financial institutions, and utility partners instrumental in building support and earning buy-in for energy efficiency and electrification upgrades in existing buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Equitable Strategies for Residential Building Energy Efficiency and Electrification in San José, California [Slides]

Hotter summers, heat waves, wildfires, and droughts are already affecting San Jose residents, with historically marginalized communities impacted first and worst. The City of San Jose has ambitious goals to make the city climate-neutral by 2030 and serve as an example for cities to accelerate climate action around the world. Electrifying and decarbonizing residential buildings are important priorities to achieve San Jose's plans to reach carbon neutrality while enabling residents to live the "Good Life 2.0" - a vision that aligns with community-identified priorities of safety, health, freedom, community, and positive experiences. This technical assistance built upon the Electrify San Jose: Framework for Existing Building Electrification to identify actionable strategies to make single- and multi-family buildings both energy-efficient and all-electric. This report is intended to provide the San Jose Climate Smart team and their partners with relevant data, insights, and actionable analysis to aid in-depth and nuanced engagements with key stakeholders. In particular, the findings in this report highlight opportunities and challenges for San Jose City Council, residents, building owners, developers, financial institutions, and utility partners instrumental in building support and earning buy-in for energy efficiency and electrification upgrades in existing buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level.

AMI data