Search NASA⌕ Search

SEARCH · Search NASA

Results for “SOLENOID”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Study on ion current density of different species in laser produced plasma in a solenoid magnet

A solenoid magnetic field along the expanding laser-produced plasma is an essential technique of the laser ion source. The solenoid field can increase ion beam current at beam extraction point by a factor of 2 to over 100 by confining moving laser produced plasma in transverse direction. This technique is used everywhere from development lab to operational machine for user operation. However, the motion of ions in laser produced plasma is not fully understood. In this study, we experimentally investigated the motion of ions in a solenoid magnet (inner diameter 102 mm, coil length 1980 mm) for Al, Fe, and Ta targets. Using the following three conditions: full solenoid bore, a φ51 mm collimator on the solenoid axis, and a thin-wall φ51 mm tube at the bottom of the solenoid, we found that extracting ions at off-axis position (20~30 mm from the solenoid axis in this study) can enhance ion intensity by a factor of three or more. We continue to investigate ion motion in a solenoid field to develop better laser ion source design.

43 PARTICLE ACCELERATORS↗

Alternative solenoid compensation scheme for the FCC-ee interaction region

We present the optics design of the solenoid compensation scheme at the FCC-ee. The 2T solenoids from the experiments induce coupling on the beams, generating an increase on vertical emittance. This compensation scheme minimizes emittance growth, with a final value of approximately 5% of the nominal. A screening solenoid is placed around the Final Focus Quadrupoles to protect them from the experiment’s field. A skew quadrupole component is added to the Final Doublet, aligning the magnet axis to the rotated reference frame of the beam. Two anti-solenoids placed approximately ±20 m from the IP are used to cancel the field integral. The vertical orbit generated by the horizontal crossing angle in the detector field is compensated by vertical correctors placed right after the beam pipe separation and next to the final focus quadrupoles. We describe the IR optics in this scheme, including the detector solenoid and the magnetic elements used for compensation.

43 PARTICLE ACCELERATORS↗

Absolute magneto-optical measurement of magnetic field on a long pulse high electrical current driven solenoid

We describe a direct absolute magneto-optical approach to measuring the magnetic field driven by long pulse width (>5 ms) and high electrical current (∼kA) in a solenoidal coil. The magnetic field and electrical current are among the most important operating parameters in lightning research and electrical power distribution and are essential to understanding the properties of the radiation output in pulsed energy accelerators as well as other research platforms. However, accurately measuring these magnetic fields and electrical currents using conventional electrical diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element material sensing crystal that is highly resistant to electromagnetic interference, allows for absolute measurement, and does not require an external calibration. Here, we focus on device theory, operating parameters, magneto-optical results from an experiment on a high current solenoid, and comparison with a calculation of the magnetic field and reference electrical current flowing downstream of the solenoid.

Owens, Israel [Sandia National Laboratories (SNL-N↗

Focusing of relativistic electron beams with permanent magnetic solenoid

Achieving strong focusing of MeV electron beams is a critical requirement for advanced beam applications such as compact laboratory x-ray sources, high gradient accelerators, and ultrafast electron scattering instrumentation. To address these needs, a compact radially magnetized permanent magnetic solenoid (PMS) has been designed, fabricated, and tested. The solenoid provides a compact and inexpensive solution for delivering high axial magnetic fields (1 T) to focus MeV electron beams. Field characterization of the solenoid demonstrates good agreement with analytical models, validating the PMS design. The electron beam test employs a high-brightness photoinjector to study the focusing properties of the PMS. The results indicate a focal length of less than 10 cm and a significant reduction in beam size with small spherical aberrations. Two application cases are evaluated: angular magnification in ultrafast electron diffraction setups and strong focusing for Compton scattering or other microfocus uses.

Electron diffraction↗

Reference Hardware and Software Architecture for a Solenoid Pulser for Scientific Instrumentation at the National Ignition Facility

High current, high voltage solenoid pulser power systems for the generation of magnetic fields in a solenoid is not a radical or new concept. Despite being a cornerstone of scientific and weapons research for over 100 years, a commercial off the shelf unit easily configurable for a broad set of applications has yet to appear on the open market. Pulser systems are instead designed for specific target requirements. For gigawatt to terawatt systems, this is unavoidable. For megawatt systems however, many hundreds of thousands of dollars are wasted designing pulser systems from the ground up for clients, when it is possible to simply architect a modular system once that can have its capacitors swapped for many possible target applications. The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory (LLNL) is one such institution that would benefit from such a system, having bought such pulsers for several imaging systems. Ideally, all such a system would require is only a bachelors-level circuit analysis to find the correct capacitor values, as well as a written procedure to calibrate the software to correctly deliver the voltages required by the application. In this work, systems architecture and software engineering techniques are used to design and analyze such a system. Such a design, it is the hope of this author, will be used in scientific and engineering purposes in the future to build solenoid pulsers at the National Ignition Facility and other institutions to drastically cut development costs of scientific instrumentation.

42 ENGINEERING↗

Tritium targets for use in solenoidal spectrometers

Nucleon adding and removing reactions are an ideal probe to study the single-particle foundations of nuclear structure. For experiments far away from the valley of stability, one needs to use radioactive beams in inverse kinematics. To maintain excellent resolution, solenoidal spectrometers like HELIOS at Argonne National Laboratory (ANL), ISS at CERN or SOLARIS at the Facility for Rare Isotope Beams (FRIB) are used. Typically, deuterated plastic foils are the targets of choice. Depending on the energy deposited, these targets might degrade quickly in beam. The potential of using tritium-implanted targets in conjunction with the solenoidal spectrometers was realized for access to even more exotic nuclei with outstanding resolving power. While no tritiated polyethylene is commercially available at the moment, tritium-containing titanium targets have been produced in the past. Unfortunately the loading fraction of tritium for the latter was often very low and not reproducible. The progress in the production of tritium-containing targets is presented, including the characterization of the foils.

Müller-Gatermann, Claus↗

Design of MARCO, the New Solenoidal Detector Magnet for the ePIC Experiment at BNL

MARCO is the new superconducting solenoid for ePIC, the general-purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider at Brookhaven National Laboratory. Here, this 3.84 m long solenoid, with a bore diameter of 2.84 m, will provide a magnetic field of 2.0 T at the center with a nominal current of 4 kA at 4.5 K, for a total stored energy of 45 MJ. Its conductor is a NbTi Rutherford in Copper Channel (RICC), specially designed to stand the high mechanical loads induced by the magnetic field. Its copper stabilizer will assure the protection in case of quench. The coils are wound into six layers inside a thin external mandrel in brass, with a triple role of mechanical reinforcement, cryogenic support for the thermosiphon circuit and quench-back propagator. With a cold mass average radial thickness of just 7 cm, the magnet fulfills all the criterions of transparency for the particles directed to the hadronic calorimeter forecast around the cryostat. In this paper, the design of MARCO is presented, with a specific focus on the magnetic and quench analysis.

Calvelli, Valerio [Commissariat a l'Energie Atomiq↗

A Low Loss, Fast Ramp HTS Solenoid Prototype for Compact Spherical Tokamaks

To explore AC loss characteristics of commercial Bi-2212 conductors made in the USA, a small ohmic heating (OH) prototype coil is being developed for compact tokamaks using high performance Bi-2212 wires newly manufactured by Bruker EST. Here, the goal is to build and test Bi-2212 prototype coils for fast ramp central solenoid (CS) operation of spherical tokamaks (ST). For a ST pilot plant, one of the key challenges is the tight space available for CS in a center column where in-board legs of the toroidal field (TF) and OH coils are assembled into a cryostat with a few millimeters clearance. A high current density Rutherford cable consisting of 17 legacy Bi-2212 wires, a contribution of the US Magnet Development Program (MDP), was fabricated at the Lawrence Berkeley National Laboratory (LBNL) for the development of fast ramp CS magnets in the ST Advanced Reactor (STAR) designed by PPPL. Characterization of the new and legacy HTS wires is presented, along with the coil design wound directly with new wire, and a Rutherford cable-wound solenoid using the legacy wire. A comparison of AC losses is made based on expected performance for a fast ramp ST operation. The HTS cable and cabled coil fabrication issues such as the heat treatment, coil mandrel design, assembly and 2212 quench characteristics are discussed, along with a test plan for CS design validation.

Zhai, Yuhu [Princeton Plasma Physics Laboratory (P↗

Solenoidal Fields from Permanent Magnets for a Polarized Electron Preinjector

This technical note describes the design of a compact focusing solenoid constructed from permanent bar magnets, intended for the low-energy section of a spin-polarized electron injector. Typically, quadrupole triplets provide appropriate focusing for the low-energy spin rotator section; however, their large footprint precludes the insertion of sufficient beam diagnostics. The primary motivation of this study is to provide beam focusing while preserving the vertical spin orientation of the electron beam. We propose a solenoidal field composed of multiple permanent magnets arranged to naturally yield a zero longitudinal magnetic field integral ($\int B_zdz = 0$). This design serves as a compact, passive, and non-coupling alternative to traditional quadrupole triplets. We present the magnet arrangement, field calculation methodology, spin tracking simulations using space charge codes, and calculations demonstrating that the required field strength is achievable.

43 PARTICLE ACCELERATORS↗

Precise Modeling of a Complex Solenoidal Magnetic Field Using a Combination of Analytic Functions and a PINN

We demonstrate an iterative approach to modeling a sparsely measured magnetic field in a large-bore solenoid. This approach uses a hybrid of traditional and machine learning techniques. The traditional technique is a linear least-squares fit using a series solution to Laplace's equation, while the machine learning technique involves the training of a physics-informed neural network (PINN) on the least-squares fit residuals. We use a newly defined activation function "DELTAsnake," a modification to the snake activation function proposed by Ziyin et al. that allows for stronger curvature and non-monotonicity. The combined model approximately obeys Maxwell's equations to a level sufficient for producing high quality physics simulations and analysis. Our approach is applied to a highly realistic calculation of the expected magnetic field in the Mu2e experiment's Detector Solenoid which includes a simple model for the expected statistical measurement uncertainties. Using ten toy measurement simulations, we demonstrate the capabilities of our model in comparison to the least-squares method alone; the least-squares method alone results in a reduced chi-squared statistic of ${2.15 \pm 0.01}$, while our approach improves the reduced chi-square to ${1.034 \pm 0.005}$. Furthermore, for an average toy simulation, we show that the range of the RMS of the three field component residuals reduces from ${0.07-0.37}$ Gauss to ${0.05-0.07}$ Gauss. We find that this novel method is robust against a realistic systematic uncertainty deriving from Hall probe calibration bias and can be used to significantly reduce the number of measurements required to achieve an accurate model.

Kampa, Cole [Caltech] (ORCID:0000000192972920)↗

Risk Assessment of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

As part of the BNL-JLab-CEA Electron Ion Collider (EIC) collaboration, the design of a 2 T, 2.8 m bore diameter, 3.8 m long conduction cooled superconducting detector magnet design is completed. Such magnet will be employed at the interaction region of ePIC for physics experiment. The magnet is a passive shielded solenoidal magnet system consisting of 3 coils wound with specially designed conductor using NbTi Rutherford type cable in copper stabilized channel. This paper describes the risk analysis as the part of Failure Modes and Effects Analysis (FMEA) that was carried out as a team to identify their various failure modes and risks associated with the magnets system. In conclusion, this FMEA is intended to become the content of the designed document as an integral part of the engineering assessment and the statement of work for the potential vendors towards design and built.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Rutherford-in-Copper-Channel Conductor for the MARCO Solenoidal Detector Magnet

MARCO will be a superconducting solenoid for a new particle physics detector of the upcoming Electron Ion Collider (EIC) at Brookhaven National Laboratory (NY, USA). The design field at the interaction point is 2.0 T with a nominal current of about 4 kA at 4.5 K. For this magnet, an aluminumstabilized conductor was considered at the very preliminary design phase. After that, since the lack of manufacturers able to deal with aluminum extrusion, copper has been chosen as stabilizer. Thanks to a dedicated design effort, the copper stabilizer and accompanying material choices provided acceptable hadronic interaction length. The conductor is based on a NbTi Rutherford cable that is soldered in a U-shaped copper profile. Here, this paper goes through the definition of the conductor crosssection according to the project requirements and the supplier capabilities. Its characteristics will be detailed and discussed, in particular the RRR and the yield strength of the copper channel needed for protection and mechanics respectively. Finally, a proposal on how to make the joint between two conductors is presented.

Stacchi, Francesco [Commissariat a l'Energie Atomi↗

Cryogenic Design and Thermal Analysis of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

The Electron Ion Collider (EIC) physics program utilizes a 2.0 T superconducting magnet at the heart of its ePIC detector system. This approximately 3.5 m long and 2.84 m diameter warm bore magnet has a 20 tons cold mass which is conduction-cooled using liquid helium at 4.5 K. A closed loop active thermosiphon system is chosen to facilitate the cooling and to maintain a minimum of 2 K temperature margin on the peak operating temperature (4.7 K) of the superconductor. Here, this paper presents the cryogenic design of the cooling system and the thermal analysis of the solenoid. A Computational fluid dynamics (CFD) model was developed to quantify the performance of the two–phase closed thermosiphon system and predict the temperature gradient on the cold mass.

Gopinath, Sandesh [Thomas Jefferson National Accel↗

Quench Analysis of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

The 2.0 T superconducting solenoid magnet (MARCO) being designed to be built for the EIC central detector (ePIC). Here, the magnet consists of three set of coil in a vacuum impregnated coil pack. Each coil pack consists of a total 554 turns winding wrapped with 6 layers of winding per coil. The coil case assembly is cooled by supercritical helium at 4.6 K. This manuscript presents quench analysis carried out on the magnet system along with the conductor stability. For the normal operation the magnet at 4.6 K and at normal operating current, the quench evaluation is carried out at 4.7 K for design assessment. The quench analysis carried out using commercial multi-physics FEA tool along an equivalent single coil quench model and the requirements for the magnet protection is also presented.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Mechanical Design of the MARCO Solenoid Detector Magnet

MARCO is the superconducting solenoid for ePIC, the new particle physics detector of the upcoming Electron Ion Collider (EIC) at the Brookhaven National Laboratory (NY, USA). The magnet has a 2.84 m warm bore diameter and is 3.85 m long. This 15 tons magnet provides a 2.0 T central field at the interaction point with a nominal current of about 4 kA at 4.5 K. The coil is composed of 6 layers of copper stabilized NbTi Rutherford in channel conductor (RIC) and it is wound internally to the brass mandrel. Here, this paper presents the detailed mechanical design of the magnet, starting with the magnet description, the material properties and the acceptance criteria considered. Then, the coil pack properties homogenization process is described. Subsequently, the 2D and 3D calculation models and their assumptions are described. At last, the computational results for the cool down and the energization are discussed. Index Terms—Superconducting Detector Magnet, material properties, homogenization, detector, EIC.

Reymond, Hugo [Commissariat a l'Energie Atomique e↗