Search NASA⌕ Search

SEARCH · Search NASA

Results for “SOP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory (BMS and RMS SOP)

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nuctech-SOP-Image_Reconstruction (includes signatures)

This Standard Operating Procedure (SOP) describes the steps to reconstruct x-ray projection images from Nuctech LS1516BS data captured at facilities operating in cooperation with the Department of Homeland Security (DHS) Explosives Threat Assessment Program (ETA). This document also provides the steps for evaluating and approving the quality of the reconstructed images.

42 ENGINEERING↗

Explosive Formulation Code Naming SOP

The purpose of this SOP is to provide a procedure for giving individual HME formulations code names. A code name for an individual HME formulation consists of an explosive family code, given by the classified code dictionary, followed by a dash, -, and a number.

42 ENGINEERING↗

Special Observing Period (SOP) data for the Year of Polar Prediction site Model Intercomparison Project (YOPPsiteMIP)

The rapid changes occurring in the polar regions require an improved understanding of the processes that are driving these changes. At the same time, increased human activities such as marine navigation, resource exploitation, aviation, commercial fishing, and tourism require reliable and relevant weather information. One of the primary goals of the World Meteorological Organization's Year of Polar Prediction (YOPP) project is to improve the accuracy of numerical weather prediction (NWP) at high latitudes. During YOPP, two Canadian “supersites” were commissioned and equipped with new ground-based instruments for enhanced meteorological and system process observations. Additional pre-existing supersites in Canada, the United States, Norway, Finland, and Russia also provided data from ongoing long-term observing programs. These supersites collected a wealth of observations that are well suited to address YOPP objectives. In order to increase data useability and station interoperability, novel Merged Observatory Data Files (MODFs) were created for the seven supersites over two Special Observing Periods (February to March 2018 and July to September 2018). All observations collected at the supersites were compiled into this standardized NetCDF MODF format, simplifying the process of conducting pan-Arctic NWP verification and process evaluation studies. This paper describes the seven Arctic YOPP supersites, their instrumentation, data collection and processing methods, the novel MODF format, and examples of the observations contained therein. MODFs comprise the observational contribution to the model intercomparison effort, termed YOPP site Model Intercomparison Project (YOPPsiteMIP). All YOPPsiteMIP MODFs are publicly accessible via the YOPP Data Portal (Whitehorse: https://doi.org/10.21343/a33e-j150, Huang et al., 2023a; Iqaluit: https://doi.org/10.21343/yrnf-ck57, Huang et al., 2023b; Sodankylä: https://doi.org/10.21343/m16p-pq17, O'Connor, 2023; Utqiagvik: https://doi.org/10.21343/a2dx-nq55, Akish and Morris, 2023c; Tiksi: https://doi.org/10.21343/5bwn-w881, Akish and Morris, 2023b; Ny-Ålesund: https://doi.org/10.21343/y89m-6393, Holt, 2023; and Eureka: https://doi.org/10.21343/r85j-tc61, Akish and Morris, 2023a), which is hosted by MET Norway, with corresponding output from NWP models.

54 ENVIRONMENTAL SCIENCES↗

LTE-P-7 IEC AEM SOP

A procedure for measuring the ion exchange capacity (IEC) of an anion exchange membrane (AEM). This is done via a titration method (automated or manual).

08 HYDROGEN↗

LTE-P-3 IEC PEM SOP

A procedure for measuring the ion exchange capacity (IEC) of a proton exchange membrane (PEM).

08 HYDROGEN↗

Robust surfactant-assisted one-pot sample preparation for label-free single-cell and nanoscale proteomics

With advanced mass spectrometry (MS)-based proteomics, genome-scale proteome coverage can be achieved from bulk cells. However, such bulk measurement obscures cell to cell heterogeneity, precluding proteome profiling of single cells and small numbers of cells of interest. To address this issue, in recent 5 years there are a surge of small sample preparation methods developed for robust effective collection and processing of single cells and small numbers of cells for in-depth MS-based proteome profiling. Based on their broad accessibility, they can be categorized into two types: specific device- and standard PCR tube- or multi-well plate-based methods. Herein we describe the detailed protocol of our recently developed, easily adoptable, Surfactant-assisted One-Pot (SOP) sample preparation coupled with MS method termed SOP-MS for label-free single-cell and nanoscale proteomics. SOP-MS capitalizes on the combination of a MS-compatible surfactant, DDM (n-Dodecyl-ß-D-maltoside), and standard low-bind PCR tube or multi-well plate for ‘all-in-one’ one-pot sample preparation without sample transfer. With its robust and convenient features, SOP-MS can be readily implemented in any MS laboratory for single-cell and nanoscale proteomics. With further improvements in MS detection sensitivity and sample throughput, we believe that SOP-MS could open an avenue for single-cell proteomics with broad applicability in the biological and biomedical research.

Single-cell proteomics, nanoscale proteomics, SOP-↗

Facile One-Pot Nanoproteomics for Label-Free Proteome Profiling of 50–1000 Mammalian Cells

Recent advances in sample preparation enable label-free MS-based proteome profiling of small numbers of mammalian cells. However, specific devices are often required to downscale sample processing volume from the standard 50-200 µL to sub-µL for effective nanoproteomics, which greatly impedes the implementation of current nanoproteomics methods by broad proteomics research community. Here we report a facile one-pot nanoproteomics method termed SOPs-MS (Surfactant-assisted One-Pot sample processing at the standard volume coupled with MS) for convenient proteome profiling of 50-1000 mammalian cells. Building upon our recent development of SOP-MS for label-free single-cell proteomics at low µL volume (Commun Bio 2021, 4, 265), we have systematically evaluated its processing volume at 10-200 µL using 100 human cells for robust reproducible nanoproteomic analysis. The processing volume of 50 µL which is in the range of volume for standard proteomics sample preparation, has been selected for easy sample handling with benchtop micropipette. Using the commonly accessible LC-MS platform, SOPs-MS allows for reliable label-free quantification of ~1200-2700 protein groups from 50-1000 MCF10A cells. When applied to small subpopulations of mouse colon crypt cells, SOPs-MS can reveal distinct protein signatures between any two subpopulation cells with identification of ~1500-2500 protein groups for each subpopulation. SOPs-MS may pave the way for routine deep proteome profiling of small numbers of cells as well as low-input samples.

59 BASIC BIOLOGICAL SCIENCES↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory: 2024 Edition

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility. This 2024 edition includes updates to the appendices to reflect the instrument changes from one year to another.

14 SOLAR ENERGY↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory: 2025 Edition

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility. This 2025 edition includes updates to the appendices to describe the current instrumentation of the NREL-SRRL.

14 SOLAR ENERGY↗

Influence of liquid conductance on the temporal evolution of self-organization patterns in atmospheric pressure DC glow discharges

Abstract Self-Organized Patterns (SOPs) at plasma-liquid interface in atmospheric pressure plasma discharges refer to the formation of intricate and puzzling structures due to the interplay of electrodynamic and hydrodynamic processes. Studies conducted to date have shown that this phenomenon results in the formation of distinctive patterns such as circular ring, star, gear, dots, spikes, etc., and primarily depends on working gas, electrolyte type, gap distance, current, conductivity, etc. However, an adequate understanding of how these patterns change from one type to another is still not available. This study aims to elucidate the influence of initial liquid conductance ( σ i ) on the temporal evolution of SOPs in liquid-anode discharges. The discharge was generated in a pin-to-liquid anode configuration at a constant helium (He) flow rate of 500 sccm and DC applied voltage of 6 kV at a gap distance of 12 mm. Through the gradual increment of σ i from 1.8 μ S to 4820 μ S, we observe that the trend in the evolution of SOPS takes place as solid discs, spikes, dots, rings, double rings, and stars. The continuous formation of reactive species onto the liquid anode in all conductive solutions results in a decrease in pH, an increase in bulk liquid temperature, and an increase in total dissolved solutes, and these have been confirmed through experimental measurements. Observations using optical emission spectroscopy show that the electrons at the plasma-liquid interface participate in the reduction of cations followed by their excitation & ionization due to which electron density as well as emissions from excited species (mainly hydroxyl radicals & excited nitrogen) decrease with time. Our investigation provides experimental evidence on the presence of cations at the plasma-liquid interface required for SOP formation.

Physics↗

Reducing Spontaneous Orientational Polarization via Semiconductor Dilution Improves OLED Efficiency and Lifetime

Spontaneous orientational polarization (SOP) in the electron-transport layer (ETL) of organic light-emitting diodes (OLEDs) is increasingly recognized as a key factor influencing their performance. Here, we show that SOP is dramatically reduced in the common electron-transport material 2,2',2"-(1,3,5-benzinetriyl)-tris(1-phenyl-1-H-benzimidazole) by coevaporating it together with medium-density polyethylene. Eliminating SOP from the ETL of blue fluorescent OLEDs in this manner reduces their operating voltage by 0.5 V, increases their external quantum efficiency (EQE) by 30%, and leads to a threefold increase in device lifetime. We show that the EQE and lifetime improvements both originate from reduced exciton-polaron annihilation in the emissive layer, and that this leads to a functional relationship between the two quantities that can be used to quantify the rate of annihilation-induced degradation in the device. Furthermore, these results highlight a substantial opportunity to improve OLED performance by controlling SOP through semiconductor dilution and suggest that this capability can be used to systematically isolate and understand exciton-polaron degradation in the pursuit of stable blue OLEDs.

36 MATERIALS SCIENCE↗

Surfactant-assisted one-pot sample preparation for label-free single-cell proteomics

Large numbers of cells are generally required for quantitative global proteome profiling due to surface adsorption losses associated with sample processing. Such bulk measurement obscures important cell-to-cell variability (cell heterogeneity) and makes proteomic profiling impossible for rare cell populations (e.g., circulating tumor cells (CTCs)). Here we report a surfactant-assisted one-pot sample preparation coupled with mass spectrometry (MS) method termed SOP-MS for label-free global single-cell proteomics. SOP-MS capitalizes on the combination of a MS-compatible nonionic surfactant, n-Dodecyl-β-D-maltoside, and hydrophobic surface-based low-bind tubes or multi-well plates for ‘all-in-one’ one-pot sample preparation. This ‘all-in-one’ method including elimination of all sample transfer steps maximally reduces surface adsorption losses for effective processing of single cells, thus improving detection sensitivity for single-cell proteomics. This method allows convenient label-free quantification of hundreds of proteins from single human cells and ~1200 proteins from small tissue sections (close to ~20 cells). When applied to a patient CTC-derived xenograft (PCDX) model at the single-cell resolution, SOP-MS can reveal distinct protein signatures between primary tumor cells and early metastatic lung cells, which are related to the selection pressure of anti-tumor immunity during breast cancer metastasis. The approach paves the way for routine, precise, quantitative single-cell proteomics.

36 MATERIALS SCIENCE↗

Terrestrial laser scanning data (Levels 0 and 1) for Pasoh, Malaysia, Sep 2024

This data package contains data from terrestrial laser scanning (TLS) at the Pasoh Forest Reserve, Malaysia. The Pasoh Forest Reserve is a facility of the Forest Research Institute Malaysia, and contains evergreen lowland dipterocarp forest. The Next-Generation Ecosystem Experiments Tropics (NGEE-Tropics) study areas at Pasoh were established to study how different species respond to climatic variation and soil water availability. Two study areas were chosen representing different topography and species. The TLS data archived here were collected to provide detailed, three-dimensional information about forest structure. Specifically, data were collected to allow tree-level characterization of woody structure and leaf area for 12 focal trees with FloraPulse and sap flux sensors, facilitating estimation of woody biomass and leaf area to allow upscaling of water content and transpiration data to the tree-level. Scan positions were not selected to provide consistent data for non-focal trees with the study areas. This data package contains the following data: - High-level files document further details of the campaign and data package: 1_CampaignSummary.csv provides details about the campaign and study site, 2_ScanAreasDetail.csv provides details about each separate scan area (groups of scans post-processed into a single point cloud), 3_TerrestrialLidarSensor.csv provides further technical details about the Riegl VZ-400i TLS sensor, TLS_CSV_dd.csv is a CSV Data Dictionary providing information about the fields in CSV files following the ESS-DIVE CSV File Formatting Guidelines Reporting Format, TLS_flmd.csv is a File Level Metadata file providing information about each file in the data package following the ESS-DIVE File Level Metadata Reporting Format, and README.txt is a text file describing the overall project and file structure. - Level 0 data are the raw data (.PROJ folders) as recorded by the Riegl VZ-400i TLS instrument before scan co-registration and post-processing with the Riegl's proprietary RiSCAN PRO software, which requires a license. - Level 1 data contain post-processed, co-registered data from each scan area. The "PointClouds" folder for each scan area contains a .las file with 1 cm resolution point cloud data exported from RiSCAN PRO. These are the main files likely to be of interest to most users and can be further processed with any software capable of manipulating .las files (e.g. Python, R CloudCompare). The "Project Information" folder contains log files from post-processing in RiSCAN PRO that may be of interest to users who want to see detailed records of post-processing, including all PDF reports generated by RiSCAN PRO. The "ScanPositions" folder contains information about the final position of all TLS scans, after post-processing, in multiple formats. The file ScanPositions_*.csv provides final geo-referenced scan positions, and the file SOP_backup_*.csv can be used in RiSCAN PRO to restore the co-registered scan positions if users wish to re-process raw data (Level 0 .PROJ folders) with RiSCAN PRO software (e.g., subsample to a different resolution, exclude a certain scan position, or apply different filters on reflectance or deviation values) without redoing time-consuming co-registration steps.

54 ENVIRONMENTAL SCIENCES↗

Terrestrial laser scanning data (Levels 0 and 1) from Urban Biogeochemistry Pilot Project sites, Knoxville, Tennessee, Jul 2024 - Jul 2025

This data package contains data from terrestrial laser scanning (TLS) at five urban park sites in Knoxville, Tennessee, USA. All parks include open-grown and/or closed-canopy trees and mixed nearby land use. These study sites were established as part of the Urban Biogeochemistry Pilot Project, which has an overall goal of better understanding how hydrobiogeochemical cycling is altered within the human environment. These five sites represent a gradient of urbanization, and were instrumented to understand hydrological and biogeochemical cycling (e.g., soil moisture, soil physical properties and biogeochemistry, tree transpiration, species type). The TLS data archived here were collected to provide detailed, three-dimensional information about forest structure. Specifically, data were collected to allow tree- and stand-level characterization of woody structure and leaf area. TLS scans were placed to capture the area around trees with sap flow sensors, and as much of a 50 m radius area around the meteorological station as possible given site property limits. Derived products will allow upscaling of water content and transpiration data. This data package contains the following data: - High-level files document further details of the campaign and data package: 1_CampaignSummary.csv provides details about the campaign and study site, 2_ScanAreasDetail.csv provides details about each separate scan area (groups of scans post-processed into a single point cloud), 3_TerrestrialLidarSensor.csv provides further technical details about the Riegl VZ-400i TLS sensor, TLS_CSV_dd.csv is a CSV Data Dictionary providing information about the fields in CSV files following the ESS-DIVE CSV File Formatting Guidelines Reporting Format, TLS_flmd.csv is a File Level Metadata file providing information about each file in the data package following the ESS-DIVE File Level Metadata Reporting Format, and README.txt is a text file describing the overall project and file structure. - Level 0 data are the raw data (.PROJ folders) as recorded by the Riegl VZ-400i TLS instrument before scan co-registration and post-processing with the Riegl's proprietary RiSCAN PRO software, which requires a license. - Level 1 data contain post-processed, co-registered data from each scan area. The "PointClouds" folder for each scan area contains a .las file with 1 cm resolution point cloud data exported from RiSCAN PRO. These are the main files likely to be of interest to most users and can be further processed with any software capable of manipulating .las files (e.g. Python, R CloudCompare). The "Project Information" folder contains log files from post-processing in RiSCAN PRO that may be of interest to users who want to see detailed records of post-processing, including all PDF reports generated by RiSCAN PRO. The "ScanPositions" folder contains information about the final position of all TLS scans, after post-processing, in multiple formats. The file ScanPositions_*.csv provides final geo-referenced scan positions, and the file SOP_backup_*.csv can be used in RiSCAN PRO to restore the co-registered scan positions if users wish to re-process raw data (Level 0 .PROJ folders) with RiSCAN PRO software (e.g., subsample to a different resolution, exclude a certain scan position, or apply different filters on reflectance or deviation values) without redoing time-consuming co-registration steps.

54 ENVIRONMENTAL SCIENCES↗

Practical procedures for sensor quality assessment

Sensors are increasingly deployed for process monitoring and control. These produce on-line measurements at a high frequency, in parallel with low-frequency laboratory measurements. Compared to laboratory practices, sensor data quality assessment and control practices are far less structured at most utilities. This leads to inaccurate sensor data with unknown uncertainty factors.This chapter shows how to establish standard operating procedures (SOPs) to support sensor data quality assessment and control and subsequent maintenance actions by producing relevant sensor metadata. Furthermore, SOPs are provided for the most commonly used wastewater quality sensors, inspired by utility and academic best practices. This chapter builds on definitions provided in Chapter 3 and provides additional definitions specifically related to sensors maintenance. Chapter 6 complements the methods in this chapter, which are based on reference measurements, with data-analytical techniques.

Alferes, Janelcy↗

PNNL ARENA Cable Motor Test Bed Update

A major focus of the Light Water Reactor Sustainability (LWRS) Cable Nondestructive Examination (NDE) 2021 research is to acquire new equipment and integrate it with existing NDE instruments for a cable motor test bed which has been dubbed the Accelerated and Real Time Experimental Nodal Analysis or “ARENA”. All the primary components have been received and are being staged in the 2410 Stevens building on PNNL’s Richland campus. Building modifications to support a plug-in 480VAC receptacle have been completed and details of the system operating procedure (SOP) are in review. The approved SOP is required before the system is energized but is expected before July 2021. The ARENA system will support planned cable tests for 2021 and beyond that cannot conveniently be performed with on-site installations of cable test equipment including: (1) NDE Tests including Frequency Domain Reflectometry (FDR), Time Domain Reflectometry (TDR), Tan Delta (TD) Impedance measurements, Low Frequency Dielectric Spectroscopy (DS) measurements, standard multi-meter resistance checks, withstand tests and other bulk and distributed tests from the instrument panel with and without motors connected. (2) Online energized live wire tests using partial discharge instruments and LIVE-WIRE spread-spectrum TDR instruments. (3) Cable tests with partially submerged cable segments (including ability to submerge live cable segments). (4) Cable tests with partially or completely thermally aged segments (including ability to expose energized cable segments to thermal aging and use online monitoring instruments to monitor cable performance. (5) Ability to introduce low resistance simulations of connector or splice faults to off-line and on-line instrument setups.

42 ENGINEERING↗

Battery data integrity and usability: Navigating datasets and equipment limitations for efficient and accurate research into battery aging

A tremendous commitment of resources is needed to acquire, understand and apply battery data in terms of performance and aging behavior. There are many state of performance (SOP) and state of health (SOH) metrics that are useful to guide alignment of batteries to end-use, yet how these metrics are measured or extracted can make the difference between usable, valuable datasets versus data that lacks the necessary integrity to meet baseline confidence levels for SOP/SOH quantification. This work will speak to 1) types of data that support SOP and SOH evaluations on mechanistic terms, 2) measurement conditions needed to assure high data integrity, 3) equipment limitations that can compromise data high fidelity, and 4) the impact of cell polarization on data quality. A common goal in battery research and field use is to work from a data platform that supports economical paths of data capture while minimizing down-time for battery diagnostics. An ideal situation would be to utilize data obtained during normal daily use (“pulses or cycles of convenience”) without stopping the daily duty cycles to perform dedicated SOP/SOH diagnostic routines. However, difficulties arise in trying to make use of daily duty cycle data (denoted as cycle-by-cycle, CBC) that underscores the need for standardization of conditions: temperature and duty cycles can vary over the course of a day and throughout a week, month and year; polarization can develop within an immediate cycle and throughout successive cycles as a hysteresis. If CBC data is envisioned as a data source to determine performance and aging trends, it should be recognized that polarization is a frequent consequence of CBC and thus makes it difficult to separate reversible and irreversible components to metrics such as capacity loss and resistance increase over aging. Since CBC conditions can have a major impact on data usability, we will devote part of this paper to CBC data conditioning and management. Differential analyses will also be discussed as a means to detect changing trends in data quality. Our target cell chemistries will be lithium-ion types NMC/graphite and LMO/LTO.

25 ENERGY STORAGE↗