A vareity of Hg capture solutions are available

While vacating the Clean Air Mercury Rule (CAMR) has postponed implementation of capturing mercury emitted by coal-fired power plants improvements in ways to capture and monitor mercury have continued. One method of enhancing Hg capture from FGD and SCR is to treat the coal by adding a halogen, such as calcium bromide in Alstom's KNX process prior to combustion. Power plants without FGD usually use sorbent injection, mostly an activated carbon, upstream of a particulate control device. 1 fig.

01 COAL, LIGNITE, AND PEAT↗

Mercury control in 2009

Although activated carbon injection (ACI) has been proven to be effective for many configurations and is a preferred option at many plants sufficient quantities of powdered activated coking (PAC) must be available to meet future needs. The authors estimate that upcoming federal and state regulations will result in tripling the annual US demand for activated carbon to nearly 1.5 billion lb from approximately 450 million lb. Rapid expansion of US production capacity is required. Many PAC manufacturers are discussing expansion of their existing production capabilities. One company, ADA Carbon Solutions, is in the process of constructing the largest activated carbon facility in North America to meet the future demand for PAC as a sorbent for mercury control. Emission control technology development and commercialization is driven by regulation and legislation. Although ACI will not achieve > 90% mercury control at every plant, the expected required MACT legislation level, it offers promise as a low-cost primary mercury control technology option for many configurations and an important trim technology for others. ACI has emerged as the clear mercury-specific control option of choice, representing over 98% of the commercial mercury control system orders to date. As state regulations are implemented and the potential for a federal rule becomes more imminent, suppliers are continuing to develop technologies to improve the cost effectiveness and limit the balance of plant impacts associated with ACI and are developing additional PAC production capabilities to ensure that the industry's needs are met. The commercialisation of ACI is a clear example of industry, through the dedication of many individuals and companies with support from the DOE and EPRI, meeting the challenge of developing cost-effectively reducing emissions from coal-fired power plants. 7 refs., 1 fig.

01 COAL, LIGNITE, AND PEAT↗

Mercury capture within coal-fired power plant electrostatic precipitators: model evaluation

Efforts to reduce anthropogenic mercury emissions worldwide have recently focused on a variety of sources, including mercury emitted during coal combustion. Toward that end, much research has been ongoing seeking to develop new processes for reducing coal combustion mercury emissions. Among air pollution control processes that can be applied to coal-fired boilers, electrostatic precipitators (ESPs) are by far the most common, both on a global scale and among the principal countries of India, China, and the U.S. that burn coal for electric power generation. A previously reported theoretical model of in-flight mercury capture within ESPs is herein evaluated against data from a number of full-scale tests of activated carbon injection for mercury emissions control. By using the established particle size distribution of the activated carbon and actual or estimated values of its equilibrium mercury adsorption capacity, the incremental reduction in mercury concentration across each ESP can be predicted and compared to experimental results. Because the model does not incorporate kinetics associated with gas-phase mercury transformation or surface adsorption, the model predictions represent the mass-transfer-limited performance. Comparing field data to model results reveals many facilities performing at or near the predicted mass-transfer-limited maximum, particularly at low rates of sorbent injection. Where agreement is poor between field data and model predictions, additional chemical or physical phenomena may be responsible for reducing mercury removal efficiencies. 26 refs., 5 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Mercury capture from flue gas using palladium nanoparticle-decorated substrates as injected sorbent

Although the Clean Air Mercury Rule (CAMR) was recently vacated by the District of Columbia Court of Appeals, efficient mercury (Hg) capture is still an important topic for the coal-fired power plant industry. Several states have Hg emission regulations that are even more stringent than CAMR guidelines. All coals contain Hg, which is released during combustion. Significant research efforts have been made to capture this toxic element before it is released to the atmosphere where it can stay suspended and travel for great distances. A variety of approaches have been examined, among which the injection of sorbent materials such as powdered activated carbon (PAC) is the current method of choice. The work presented here examined the mercury capture capability of various carbon substrates decorated with metal nanoparticles when injected as sorbents. Sorbent injections were carried out in a Hg in air mixture for laboratory-scale screening and in a real flue gas at a coal-fired power plant. It was found that palladium-decorated carbon substrates showed excellent mercury capture capabilities, with total efficiencies greater than 90% in laboratory-scale tests. In the real flue gas, the total efficiency was on the order of 60%, comparable to the benchmark commercial sorbent Darco Hg-LH, a brominated PAC, although the tested adsorbents had much lower surface areas. The results of this study are presented herein. Novel mercury capture from a coal-fired flue gas was achieved using carbon substrates decorated with palladium nanoparticles. 15 refs., 7 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Projections of global mercury emissions in 2050.

Global Hg emissions are presented for the year 2050 under a variety of assumptions about socioeconomic and technology development. We find it likely that Hg emissions will increase in the future. The range of 2050 global Hg emissions is projected to be 2390-4860 Mg, compared to 2006 levels of 2480 Mg, reflecting a change of -4% to +96%. The main driving force for increased emissions is the expansion of coal-fired electricity generation in the developing world, particularly Asia. Our ability to arrest the growth in Hg emissions is limited by the relatively low Hg removal efficiency of the current generation of emission control technologies for coal-fired power plants (flue-gas desulfurization). Large-scale deployment of advanced Hg sorbent technologies, such as Activated Carbon Injection, offers the promise of lowering the 2050 emissions range to 1670-3480 Mg, but these technologies are not yet in commercial use. The share of elemental Hg in total emissions will decline from today's levels of {approx}65% to {approx}50-55% by 2050, while the share of divalent Hg will increase. This signals a shift from long-range transport of elemental Hg to local deposition of Hg compounds though emissions of both species could increase under the worst case.

54 ENVIRONMENTAL SCIENCES↗

Computer simulation as a NOx reduction design tool

Nalco Mobotec engineers were charged with reducing emissions on a utility boiler converted from burning oil to eastern bituminous coal using the company's Rotamix selective noncatalytic reduction (SNCR) system which injects urea into the furnace. A CFD simulation of the existing boiler was first conducted and then the furnace was simulated with the SNCR system added and the design was optimised. Operating and capital costs were minimised by optimal placement of 50 injector ports. 6 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Bringing down the cost of SO{sub 2} and NOx removal

A twist of an old technique, flue gas recirculating, helps prevent slagging in the upper furnace and convective pass, according to pilot testing recently completed by APTECH CST and the South Research Institute. The technology, along with a companion technology for furnace sorbent and urea injection for SO{sub 2} and NOx control, could help owner/operators of smaller, older coal-fired plants meet emissions limits at a reasonable cost. The article reviews the details and results of initial pilot-scale testing. Results met all the company's expectations when testing Powder River Basin and Galatia coals. A full-scale project is planned for operation in 2009. 7 figs.

01 COAL, LIGNITE, AND PEAT↗

Performance of copper chloride-impregnated sorbents on mercury vapor control in an entrained-flow reactor system

An entrained-flow system has been designed and constructed to simulate in-flight mercury (Hg) capture by sorbent injection in ducts of coal-fired utility plants. The test conditions of 1.2-sec residence time, 140{degree}C gas temperature, 6.7 m/sec (22 ft/sec) gas velocity, and 0-0.24 g/m{sup 3} (0-15 lbs of sorbent per 1 million actual cubic feet of flue gas sorbent injection rates were chosen to simulate conditions in the ducts. Four kinds of sorbents were used in this study. Darco Hg-LH (lignite-based) served as a benchmark sorbent with which Hg control capability of other sorbents could be compared. Also, Darco-FGD (lignite-based) was used as a representative raw activated carbon sorbent. Two different copper chloride-impregnated sorbents were developed in the laboratory and tested in the entrained-flow system to examine the possibility of using these sorbents at coal-fired power plants. The test results showed that one of the copper chloride sorbents has remarkable elemental mercury (Hg{sup 0}) oxidation capability, and the other sorbent demonstrated a better performance in Hg removal than Darco Hg-LH. 13 refs., 4 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Enhancement of mercury capture by the simultaneous addition of hydrogen bromide (HBr) and fly ashes in a slipstream facility

Low halogen content in tested Powder River Basin (PRB) coals and low loss of ignition content (LOI) in PRB-derived fly ash were likely responsible for higher elemental mercury content (averaging about 75%) in the flue gas and also lower mercury capture efficiency by electrostatic precipitator (ESP) and wet-FGD. To develop a cost-effective approach to mercury capture in a full-scale coal-fired utility boiler burning PRB coal, experiments were conducted adding hydrogen bromide (HBr) or simultaneously adding HBr and selected fly ashes in a slipstream reactor (0.152 x 0.152 m) under real flue gas conditions. The residence time of the flue gas inside the reactor was about 1.4 s. The average temperature of the slipstream reactor was controlled at about 155{sup o}C. Tests were organized into two phases. In Phase 1, only HBr was added to the slipstream reactor, and in Phase 2, HBr and selected fly ash were added simultaneously. HBr injection was effective (>90%) for mercury oxidation at a low temperature (155{sup o}C) with an HBr addition concentration of about 4 ppm in the flue gas. Additionally, injected HBr enhanced mercury capture by PRB fly ash in the low-temperature range. The mercury capture efficiency, at testing conditions of the slipstream reactor, reached about 50% at an HBr injection concentration of 4 ppm in the flue gas. Compared to only the addition of HBr, simultaneously adding bituminous-derived fly ash in a minimum amount (30 lb/MMacf), together with HBr injection at 4 ppm, could increase mercury capture efficiency by 30%. Injection of lignite-derived fly ash at 30 lb/MMacf could achieve even higher mercury removal efficiency (an additional 35% mercury capture efficiency compared to HBR addition alone). 25 refs., 5 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Bench-scale studies of in-duct mercury capture using cupric chloride-impregnated carbons

A brominated activated carbon (Darco Hg-LH) and cupric chloride-impregnated activated carbon (CuCl{sub 2}-ACs) sorbent have been tested in a bench-scale entrained-flow reactor system which was developed for simulating in-flight mercury capture in ducts upstream of particulate matter control devices. The bench-scale experimental system has been operated with the conditions of a residence time of 0.75 s and a gas temperature of 140{sup o}C to simulate typical conditions in the duct of coal-fired exhaust gas. In addition, sorbent deposition on walls which can occur in a laboratory-scale system more than in a full-scale system was significantly reduced so that additional mercury capture by the deposited sorbent was minimized. In the entrained-flow system, CuCl{sub 2}-ACs demonstrated similar performance in Hg adsorption and better performance in Hg{sup 0} oxidation than Darco Hg-LH. In addition, the carbon content of those sorbents was found to determine their Hg adsorption capability in the entrained-flow system. The bench-scale entrained-flow system was able to demonstrate the important Hg adsorption and oxidation characteristics of the tested sorbents. 18 refs., 9 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Removing mercury from coal emissions: options for ash-friendly technologies

The article gives a brief description of techniques to remove mercury emitted from coal-fired power plants and discusses environmental considerations associated with the effect of emission controls on coal fly ash. Techniques covered include use of injected mercury sorbents (activated carbon, metal oxide catalysts, MerCAP{trademark} and MercScreen{trademark}) and fuel cleaning. Technologies currently being researched are mentioned. 8 refs.

01 COAL, LIGNITE, AND PEAT↗

Technology could deliver 90% Hg reduction from coal

Reducing mercury emissions at coal-fired power plants by 90% has been considered the holy grail of mercury control. A new technology promises to get used there, but at a price. This is a mixture of chemical approaches, including activated carbon injection into the gases coming off the combustor along with injection of trona or calcium carbonate to reduce sulfur trioxide in the exhaust gases. The trick according to Babcock and Wilcox's manager Sam Kumar, to 'capture the mercury as a particulate on the carbon and then capture the particulate' in an electrostatic precipitator or a fabric filter baghouse. 2 figs.

01 COAL, LIGNITE, AND PEAT↗

Mercury control challenge for industrial boiler MACT affected facilities

An industrial coal-fired boiler facility conducted a test program to evaluate the effectiveness of sorbent injection on mercury removal ahead of a fabric filter with an inlet flue gas temperature of 375{sup o}F. The results of the sorbent injection testing are essentially inconclusive relative to providing the facility with enough data upon which to base the design and implementation of permanent sorbent injection system(s). The mercury removal performance of the sorbents was significantly less than expected. The data suggests that 50 percent mercury removal across a baghouse with flue gas temperatures at or above 375{sup o}F and containing moderate levels of SO{sub 3} may be very difficult to achieve with activated carbon sorbent injection alone. The challenge many coal-fired industrial facilities may face is the implementation of additional measures beyond sorbent injection to achieve high levels of mercury removal that will likely be required by the upcoming new Industrial Boiler MACT rule. To counter the negative effects of high flue gas temperature on mercury removal with sorbents, it may be necessary to retrofit additional boiler heat transfer surface or spray cooling of the flue gas upstream of the baghouse. Furthermore, to counter the negative effect of moderate or high SO{sub 3} levels in the flue gas on mercury removal, it may be necessary to also inject sorbents, such as trona or hydrated lime, to reduce the SO{sub 3} concentrations in the flue gas. 2 refs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Controlling mercury emissions from coal-fired power plants

Increasingly stringent US federal and state limits on mercury emissions form coal-fired power plants demand optimal mercury control technologies. This article summarises the successful removal of mercury emissions achieved with activated carbon injection and boiler bromide addition, technologies nearing commercial readiness, as well as several novel control concepts currently under development. It also discusses some of the issues standing in the way of confident performance and cost predictions. In testing conducted on western coal-fired units with fabric filters or TOXECON to date, ACI has generally achieved mercury removal rates > 90%. At units with ESPs, similar performance requires brominated ACI. Alternatively, units firing western coals can use boiler bromide addition to increase flue gas mercury oxidation and downstream capture in a wet scrubber, or to enhance mercury removal by ACI. At eastern bituminous fired units with ESPs, ACI is not as effective, largely due to SO{sub 3} resulting from the high sulfur content of the coal or the use of SO{sub 3} flue gas conditioning to improve ESP performance. 7 refs., 3 figs.

01 COAL, LIGNITE, AND PEAT↗

Sorption Mechanisms for Mercury Capture in Warm Post-Gasification Gas Clean-Up Systems

The research was directed towards a sorbent injection/particle removal process where a sorbent may be injected upstream of the warm gas cleanup system to scavenge Hg and other trace metals, and removed (with the metals) within the warm gas cleanup process. The specific objectives of this project were to understand and quantify, through fundamentally based models, mechanisms of interaction between mercury vapor compounds and novel paper waste derived (kaolinite + calcium based) sorbents (currently marketed under the trade name MinPlus). The portion of the research described first is the experimental portion, in which sorbent effectiveness to scavenge metallic mercury (Hg{sup 0}) at high temperatures (>600 C) is determined as a function of temperature, sorbent loading, gas composition, and other important parameters. Levels of Hg{sup 0} investigated were in an industrially relevant range ({approx} 25 {micro}g/m{sup 3}) although contaminants were contained in synthetic gases and not in actual flue gases. A later section of this report contains the results of the complementary computational results.

01 COAL, LIGNITE, AND PEAT↗

Utilization of Partially Gasified Coal for Mercury Removal

In this project, General Electric Energy and Environmental Research Corporation (EER) developed a novel mercury (Hg) control technology in which the sorbent for gas-phase Hg removal is produced from coal in a gasification process in-situ at a coal burning plant. The main objective of this project was to obtain technical information necessary for moving the technology from pilot-scale testing to a full-scale demonstration. A pilot-scale gasifier was used to generate sorbents from both bituminous and subbituminous coals. Once the conditions for optimizing sorbent surface area were identified, sorbents with the highest surface area were tested in a pilot-scale combustion tunnel for their effectiveness in removing Hg from coal-based flue gas. It was determined that the highest surface area sorbents generated from the gasifier process ({approx}600 m{sup 2}/g) had about 70%-85% of the reactivity of activated carbon at the same injection rate (lb/ACF), but were effective in removing 70% mercury at injection rates about 50% higher than that of commercially available activated carbon. In addition, mercury removal rates of up to 95% were demonstrated at higher sorbent injection rates. Overall, the results of the pilot-scale tests achieved the program goals, which were to achieve at least 70% Hg removal from baseline emissions levels at 25% or less of the cost of activated carbon injection.

01 COAL, LIGNITE, AND PEAT↗

Evaluation of the efficacy of polyphosphate remediation technology: Direct and indirect remediation of uranium under alkaline conditions

A field-scale technology demonstration has been conducted to optimize polyphosphate remediation technology for enhanced monitored natural attenuation of the uranium plume within the 300 Area aquifer at the Hanford Site, southeastern Washington State. The objective was to evaluate the efficacy of polyphosphate to treat uranium-contaminated groundwater in situ. Focused application of polyphosphate was conducted in a source or 'hot spot' area to reduce the inventory of available uranium contributing to the groundwater plume through direct precipitation of uranyl-phosphate solids and secondary containment via precipitation of apatite which can serve as a long-term sorbent for uranium. The test site consisted of an injection well and 15 monitoring wells installed in the 300 Area near the process trenches that had previously received uranium-bearing effluents. The results indicated sequestration of uranium as insoluble phosphate phases appears to be a promising alternative for treating the uranium- contaminated groundwater at the Hanford Site 300 Area. However, the formation of the apatite during the test was limited due to two separate overarching issues: (1) formation and emplacement of apatite via polyphosphate technology, and (2) efficacy of apatite for sequestering uranium under the present geochemical and hydrodynamic conditions.

54 ENVIRONMENTAL SCIENCES↗