Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPECS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Second-generation Micro-Spec: Spectrometer Design for the Experiment for Cryogenic Large-Aperture Intensity Mapping

Micro-Spec (μ-Spec) is a direct-detection spectrometer that integrates all the components of a diffraction-grating spectrometer onto a ∼10-cm2 chip using superconducting microstrip transmission lines on a single-crystal silicon substrate. The second-generation μ-Spec has been designed to operate with a spectral resolution of ∼512 in the far-infrared and submillimeter (420–540 GHz, 714–555 μm) wavelength range, a band of interest for NASA’s EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM). EXCLAIM will be a high-altitude balloon mission that is being designed to map the emission of redshifted carbon monoxide and singly-ionized carbon lines over a redshift range 0 < z < 3.5. EXCLAIM will be the first demonstration of the μ-Spec technology in a space-like environment. This work reviews the status of the μ-Spec design for the EXCLAIM instrument, with emphasis on the spectrometer’s two-dimensional diffractive region, through which light of different wavelengths is focused on microwave kinetic inductance detectors (MKIDs) along the spectrometer focal plane. An optimization process generates a geometrical configuration of the diffractive region that satisfies specific requirements on size, operating spectral range and performance. An initial optical design optimized for EXCLAIM is presented in terms of geometric layout, spectral purity and efficiency.

Giuseppe Cataldo↗

Verification of the Shafranov shift in free-boundary VMEC, DESC, and SPEC calculations with elliptical geometry

Here, given a set of current-carrying filaments that create a magnetic field with rotating elliptical flux surfaces, we present verification calculations using the VMEC, DESC, and SPEC free-boundary magnetohydrostatic equilibrium codes for both the “vacuum” equilibrium, for which there is no plasma pressure and no plasma currents, and for a non-zero pressure, zero toroidal current equilibrium. For the vacuum case, these codes are quantitatively compared to the magnetic field produced by the coils. For the non-zero pressure case, they are compared to each other. As the stepped pressure profile used in SPEC approaches the continuous profile used in VMEC and DESC, the SPEC magnetic axis approaches the VMEC and DESC axes. To within an error given by the difference between the pressure profiles, the VMEC, DESC, and SPEC calculations give the same pressure-induced geometric shift of the magnetic axis, known as the Shafranov shift.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Performance of Micro-Spec, an Ultra Compact High-Sensitivity Far-Infrared Spectrometer for SPICA

Micro-Spec (u-Spec) is a high-performance spectrometer working in the 250-700-micrometer wavelength range, whose modules use low-loss superconducting microstrip transmission lines on a single 4-inch-diameter silicon wafer. Creating the required phase delays in transmission lines rather than free space allows such an instrument to have, in principle, the performance of a meter-scale grating spectrometer. Such a dramatic size reduction enables classes of instruments for space that would be impossible with conventional technologies. This technology can dramatically enhance the long-wavelength capability of the space infrared telescope for cosmology and astrophysics SPICA. u-Spec is analogous to a grating spectrometer. The phase retardation generated by the reflection from the grating grooves is instead produced by propagation through a transmission line. The power received by a broadband antenna is progressively divided by binary microstrip power dividers, and the required phase delays are generated by different lengths of microstrip transmission lines. by arranging these outputs along a circular focal surface, the analog of a Rowland spectrometer can he created. The procedure to optimize the Micro-Spec design is based on the stigmatization and minimization of the light path function in a two-dimensional hounded region, which results in an optimized geometry arrangement with three stigmatic points. In addition, in order to optimize the overall efficiency of the instrument, the emitters are directed to the center of the focal surface. The electric field amplitude and phase as well as the power transmitted and absorbed throughout the region are analyzed. Measurements are planned in late summer to validate the designs.

Cataldo, Giuseppe↗

Second-Generation Design of Micro-Spec: A Medium-Resolution, Submillimeter-Wavelength Spectrometer-on-a-Chip

Micro-Spec (μ-Spec) is a direct-detection spectrometer which integrates all the components of a diffraction-grating spectrometer onto a ∼10-cm2 chip through the use of superconducting microstrip transmission lines on a single-crystal silicon substrate. A second-generation μ-Spec is being designed to operate with a spectral resolution of 512 in the submillimeter (500-1000 μm, 300-600 GHz) wavelength range, a band of interest for several spectroscopic applications in astrophysics. High altitude balloon missions would provide the first test bed to demonstrate the μ-Spec technology in a space-like environment and would be an economically viable venue for multiple observation campaigns. This work reports on the current status of the instrument design and will provide a brief overview of each instrument subsystem. Particular emphasis will be given to the design of the spectrometer's two-dimensional diffractive region, through which the light of different wavelengths is focused on the detectors along the focal plane. An optimization process is employed to generate geometrical configurations of the diffractive region that satisfy specific requirements on spectrometer size, operating spectral range, and performance. An optical design optimized for balloon missions will be presented in terms of geometric layout, spectral purity, and efficiency.

Cataldo, G.↗

Second-Generation Micro-Spec: A Compact Spectrometer for Far-Infrared and Submillimeter Space Missions

Micro-Spec is a direct-detection spectrometer which integrates all the components of a diffraction-grating spectrometer onto a ≈ 10-sq.cm chip through the use of superconducting microstrip transmission lines on a single- crystal silicon substrate. The second generation of Micro-Spec is being designed to operate with a spectral re- solution of at least 512 in the far-infrared and submillimeter (420–540 GHz, 714–555 μm) wavelength range, a band of interest for NASA's experiment for cryogenic large-aperture intensity mapping called EXCLAIM. EXCLAIM will be a balloon-borne telescope that is being designed to map the emission of redshifted carbon monoxide and singly-ionized carbon lines over a redshift range 0 < z < 3.5 and it will be the first demonstration of the Micro-Spec technology in a space-like environment. This work reviews the status of the Micro-Spec design for the EXCLAIM telescope, with emphasis on the spectrometer's two-dimensional diffractive region, through which light of different wavelengths is focused on kinetic inductance detectors along the instrument focal plane. An optimization process is used to generate a geometrical configuration of the diffractive region that satisfies l range and performance. An initial optical design optimized for n terms of geometric layout, spectral purity and efficiency.

Cataldo, Giuseppe↗

Developing a New Generation of Integrated Micro-Spec Far Infrared Spectrometers for the EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)

The current state of far-infrared astronomy drives the need to develop compact, sensitive spectrometers for future space and ground-based instruments. Here we present details of the µ-Spec spectrometers currently in development for the far-infrared balloon mission EXCLAIM. The spectrometers are designed to cover the 555 – 714 µm range with a resolution of R = λ/∆λ = 512 at the 638 µm band center. The spectrometer design incorporates a Rowland grating spectrometer implemented in a parallel plate waveguide on a low-loss single-crystal Si chip, employing Nb microstrip planar transmission lines and thin-film Al kinetic inductance detectors (KIDs). The EXCLAIM µ-Spec design is an advancement upon a successful R = 64 µ-Spec prototype, and can be considered a sub-mm superconducting photonic integrated circuit (PIC) that combines spectral dispersion and detection. The design operates in a single M=2 grating order, allowing one spectrometer to cover the full EXCLAIM band without requiring a multi-order focal plane. The EXCLAIM instrument will fly six spectrometers, which are fabricated on a single 150 mm diameter Si wafer. Fabrication involves a flip-wafer-bonding process with patterning of the superconducting layers on both sides of the Si dielectric. The spectrometers are designed to operate at 100 mK, and will include 355 Al KID detectors targeting a goal of NEP ∼8 × 10−19 W/√( Hz). We summarize the design, fabrication, and ongoing development of these µ-Spec spectrometers for EXCLAIM.

Carolyn G. Volpert↗

Evaluating Performance Portability of Accelerator Programming Models using SPEC ACCEL 1.2 Benchmarks

As heterogeneous architectures are becoming mainstream for HPC systems, application programmers are looking for programming model implementations that offer both performance and portability across platforms. Two directive-based programming models for accelerator programming that aim at doing this are OpenMP 4/4.5 and OpenACC. Many users want to know the difference between these two programming models, the state of their implementations, how to use them, and evaluate how suitable they are for their applications.The Standard Performance Evaluation Corporation (SPEC) ACCEL benchmarks, developed by the SPEC High Performance Group (HPG), recently released SPEC ACCEL 1.2 benchmark suite to help the evaluation of OpenCL, OpenMP 4.5 and OpenACC on different platforms. Inthis paper we present our preliminary results that evaluates OpenMP4.5 and OpenACC on a variety of accelerator-based systems: POWER9with NVIDIA V100 GPUs (Summit), Intel Xeon Phi 7230 (Percival), and AMD Bulldozer Opteron with NVIDIA K20x (Titan). Comparing these benchmarks on different systems gives us insight into the support for OpenMP and OpenACC and their execution times provide insights about their quality of implementations provided by different vendors. We also compare best of OpenMP and OpenACC to see if a particular programming model favors a particular type of benchmark kernel.

Boehm, Swen↗

MEASUREMENTS OF CO REDSHIFTS WITH Z-SPEC FOR LENSED SUBMILLIMETER GALAXIES DISCOVERED IN THE H-ATLAS SURVEY

We present new observations from Z-Spec, a broadband 185-305 GHz spectrometer, of five submillimeter bright lensed sources selected from the Herschel-Astrophysical Terahertz Large Area Survey science demonstration phase catalog. We construct a redshift-finding algorithm using combinations of the signal to noise of all the lines falling in the Z-Spec bandpass to determine redshifts with high confidence, even in cases where the signal to noise in individual lines is low. We measure the dust continuum in all sources and secure CO redshifts for four out of five (z {approx} 1.5-3). In one source, SDP.17, we tentatively identify two independent redshifts and a water line, confirmed at z = 2.308. Our sources have properties characteristic of dusty starburst galaxies, with magnification-corrected star formation rates of 10{sup 2-3} M{sub Sun} yr{sup -1}. Lower limits for the dust masses ({approx} a few 10{sup 8} M{sub Sun }) and spatial extents ({approx}1 kpc equivalent radius) are derived from the continuum spectral energy distributions, corresponding to dust temperatures between 54 and 69 K. In the local thermodynamic equilibrium (LTE) approximation, we derive relatively low CO excitation temperatures ({approx}< 100 K) and optical depths ({tau} {approx}< 1). Performing a non-LTE excitation analysis using RADEX, we find that the CO lines measured by Z-Spec (from J = 4 {yields} 3 to 10 {yields} 9, depending on the galaxy) localize the best solutions to either a high-temperature/low-density region or a low/temperature/high-density region near the LTE solution, with the optical depth varying accordingly. Observations of additional CO lines, CO(1-0) in particular, are needed to constrain the non-LTE models.

79 ASTRONOMY AND ASTROPHYSICS↗

The Submillimeter Probe of the Evolution of Cosmic Structure (SPECS)

The NASA roadmap mission SPECS is conceived as an imaging and spectral interferometer that will have the sensitivity needed to reach back in time to the formation epoch of the first luminous objects, the angular resolution needed to image proto-planetary systems and galaxies at high redshift, and the spectral resolution needed to probe the physical conditions and measure the flows of interstellar gas in young galaxies, nascent stars, and the dust-enshrouded nuclei of galaxies that harbor massive black holes. With a 1 km maximum baseline and the capability to sample the u-v plane completely, SPECS will produce images with angular resolution 20 (lambda / 100 microns) mas over the wavelength range 40 less than lambda less than 800 microns. In this talk I will give the scientific motivation for SPECS, describe mission concepts and telescope measurement capabilities, and compare these capabilities with those of the next-generation IR telescopes, and with the complementary JWST and ALMA.

Leisawitz, David↗

NASA's Far-IR/Submillimeter Roadmap Missions SAFIR and SPECS

The far-IR is rich with information about star, disk and planet formation because protostars emit predominantly in this spectral range, and the radiation can escape from the inherently dusty stellar birth sites. Spectral lines contain particularly valuable information about the cooling, collapse, and chemistry of molecular cloud cores and protostars. However, the interpretation of line intensities and profiles is model-dependent; ultimately, high angular resolution is needed to break model degeneracy and definitively characterize the source. Processes occurring on scales smaller than 10,000 AU (72 arcsec at 140 pc, where the nearest protostellar objects are found) likely affect the stellar initial mass function and determine the product of cloud collapse (Binary star or planetary system? How many planets, and what kind will they be?) The next-generation far-IR observatories SIRTF, SOFIA, and Herschel will revolutionize star formation studies and leave the community yearning for telescopes that operate in this spectral region but provide many orders of magnitude better angular resolution. NASA's space science roadmap includes the JWST-scale Single Aperture Far-IR (SAFIR) telescope and the 1 km maximum baseline far-IR interferometer, SPECS (the Submillimeter Probe of the Evolution of Cosmic Structure). I will give the scientific motivation for these missions, describe mission concepts and telescope measurement capabilities, and compare these capabilities with those of the next-generation IR telescopes and with the complementary JWST and ALMA. I will also describe the Space Infrared Interferometric Telescope (SPIRIT), a science and technology pathfinder for SPECS, which could be ready to launch in about a decade. At 100 microns, SAFIR will provide 2.5 arcsec resolution (10 times better than SIRTF), SPIRIT will provide 0.25 arcsec resolution, and SPECS will provide 10 milli-arcsec resolution, which is comparable to that of the Hubble Space Telescope.

Leisawitz, David↗

Micro-spec: an Integrated Direct-detection Spectrometer for Far-infrared Space Telescopes

The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements.Micro-Spec (μ-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 (micrometers) wavelength range which will enable a wide range of flight missions that would otherwise be challenging due tothe large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 sq cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for micro-Spec is presented, with particular attention given to its two-dimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance.Two point designs with resolving power of 260 and 520 and an RMS phase error less than approximately 0.004 radians were developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.

Far-infrared↗

Micro-Spec: an Integrated, Direct-Detection Spectrometer for Far-Infrared and Submillimeter Astronomy

The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements. Micro-Spec (u-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 micromillimeter wavelength range which will enable a wide range of flight missions that would otherwise be challenging due to the large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 square cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for Micro-Spec is presented, with particular attention given to its twodimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance. A point design with resolving power of 257, an RMS phase error less than 0.1 radians and four stigmatic points was developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.

microwave kinetic inductance detectors (MKIDs)↗

Design and Performance of A High Resolution Micro-Spec: An Integrated Sub-Millimeter Spectrometer

Micro-Spec is a compact sub-millimeter (approximately 100 GHz--1:1 THz) spectrometer which uses low loss superconducting microstrip transmission lines and a single-crystal silicon dielectric to integrate all of the components of a diffraction grating spectrometer onto a single chip. We have already successfully evaluated the performance of a prototype Micro-Spec, with spectral resolving power, R=64. Here we present our progress towards developing a higher resolution Micro-Spec, which would enable the first science returns in a balloon flight version of this instrument. We describe modifications to the design in scaling from a R=64 to a R=256 instrument, as well as the ultimate performance limits and design concerns when scaling this instrument to higher resolutions.

spectrometer↗

Micro-Spec: An Ultracompact, High-sensitivity Spectrometer for Far-Infrared and Submillimeter Astronomy

High-performance, integrated spectrometers operating in the far-infrared and submillimeter ranges promise to be powerful tools for the exploration of the epochs of reionization and initial galaxy formation. These devices, using high-efficiency superconducting transmission lines, can achieve the performance of a meter-scale grating spectrometer in an instrument implemented on a 4 inch silicon wafer. Such a device, when combined with a cryogenic telescope in space, provides an enabling capability for studies of the early universe. Here, the optical design process for Micro-Spec (micron-Spec) is presented, with particular attention given to its two-dimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the stigmatization and minimization of the light path function in this bounded region, which results in an optimized geometrical configuration. A point design with an efficiency of (is) approximately 90% has been developed for initial demonstration and can serve as the basis for future instruments. Design variations on this implementation are also discussed, which can lead to lower efficiencies due to diffractive losses in the multimode region.

cryogenic telescope↗

Using micro hardware to integrate EPICS and SPEC.

This paper describes the steps needed to use SPEC's 'macro hardware facility' for control and reading of EPICS process variables. This resource allows many instruments that can communicate with EPICS to be integrated into the SPEC diffractometer-control program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HIGH SPECTRAL RESOLUTION MEASUREMENT OF THE SUNYAEV-ZEL'DOVICH EFFECT NULL WITH Z-Spec

The Sunyaev-Zel'dovich (SZ) effect spectrum crosses through a null where {Delta}T{sub CMB} = 0 near {nu}{sub 0} = 217 GHz. In a cluster of galaxies, {nu}{sub 0} can be shifted from the canonical thermal SZ effect value by corrections to the SZ effect scattering due to the properties of the inter-cluster medium. We have measured the SZ effect in the hot galaxy cluster RX J 1347.5 - 1145 with Z-Spec, an R {approx} 300 grating spectrometer sensitive between 185 and 305 GHz. These data comprise a high spectral resolution measurement around the null of the SZ effect and clearly exhibit the transition from negative to positive {Delta}T{sub CMB} over the Z-Spec band. The SZ null position is measured to be {nu}{sub 0} = 225.8 {+-} 2.5(stat.) {+-} 1.2(sys.) GHz, which differs from the canonical null frequency by 3.0{sigma} and is evidence for modifications to the canonical thermal SZ effect shape. Assuming the measured shift in {nu}{sub 0} is due only to relativistic corrections to the SZ spectrum, we place the limit kT{sub e} = 17.1 {+-} 5.3 keV from the zero-point measurement alone. By simulating the response of the instrument to the sky, we are able to generate likelihood functions in {l_brace}y{sub 0}, T{sub e}, v{sub pec}{r_brace} space. For v{sub pec} = 0 km s{sup -1}, we measure the best-fitting SZ model to be y{sub 0} = 4.6{sup +0.6}{sub -0.9} Multiplication-Sign 10{sup -4}, T{sub e,0} = 15.2{sup +12}{sub -7.4} keV. When v{sub pec} is allowed to vary, a most probable value of v{sub pec} = + 450 {+-} 810 km s{sup -1} is found.

79 ASTRONOMY AND ASTROPHYSICS↗

SPECs Early-Stage Decision Model: User Manual

The SPECs Early-Stage Decision (ESD) model is central to the SPECs procurement solutions toolkit. The ESD model is an Excel-based spreadsheet model, which provides information about the economic and strategic value of a proposed battery-storage project or solar-plus-storage (solar-plus) project. The model can be used to explore combinations of storage-related project value streams in order to define a potential project, while educating co-op decision-makers about project benefits and costs. A sensitivity analysis function speeds the development of "what-if" scenarios. A gap analysis function solves for top-priority metrics and supports the inclusion of hard-to-monetize strategic values, such as the value of storage to defer costly system upgrades in light of increasing distributed solar and other distributed energy resources (DERs). Model outputs include the utility data, assumptions, and use-case scenarios that are recommended content for the requests for proposals (RFPs). The model may also provide an initial "sanity check" for RFP responses, supporting further discussions among utility staff, vendors and stakeholders. The ESD is not a "finance-grade" modeling tool, and users are cautioned to be mindful of its limitations, but the model has been reviewed by users, who recommend it as a way to drive faster and better project design and planning, as well as to facilitate better communications with vendors, grid partners, and stakeholders.

14 SOLAR ENERGY↗

High Yield nTOF Spec A and NP Filter Holders Static and Seismic Analysis

The Neutron Time-of-Flight (nTOF) detectors located in the Alcove and at the North Pole (Spec A and Spec NP respectively) need filtering in the beam path to enable them to take data at NIF yields above 5MJ. The filtering consists of 12cm of filter material divided into four, 3cm thick “pucks.” The pucks are 7cm in diameter. Each puck is mounted into a rotatable stage, also called a Filter Flipper, that can bring it into and out of the beam path, see Figure 1-1. These stages are bolted onto a plate that connects the filter stages to the mounting hardware used to position them in the NIF Target Bay. The top-level filter mount assemblies will be permanently mounted in the facility; removal is possible if needed for NIF maintenance, but the design intent is for the assemblies to remain in their locations after alignment is completed.

42 ENGINEERING↗