Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPECTRAL RESPONSE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An assessment of the impact of system spectral response parameters on spectral shape and algal bloom detection for the GeoXO ocean color instrument (OCX)

NOAA’s Geostationary Extended Observations (GeoXO) program is planning to include a hyperspectral ocean color instrument (OCX) in geostationary orbit slated for operations by the early 2030s. Shared international focus has led to a diverse legacy of space-based remote sensing ocean color missions that have and will continue to provide ocean color products into the future at a variety of spatial, temporal, and spectral resolutions. This work reports on an investigation of the impacts of system spectral response parameters on spectral shape and algal bloom detection for the planned OCX instrument. A large dataset in-situ spectra, from a variety of locations and water cases collected with an above water spectrometer, was used to simulate OCX observations of varying system spectral response parameters. The OCX Performance Operational Requirements Document (PORD) level spectral resolution and sampling are varied concurrently and the location of band centers is varied independently. The impacts to the spectral shape using hyperspectral signature analysis, as well as the impacts to two heritage multispectral algal bloom detection algorithms – red band difference (RBD) and Karenia brevis bloom index (KBBI) – are assessed considering both changes in resolution/sampling and band center location. This work provides a quantitative assessment of the impacts of system spectral response requirements on both the spectral shape of observations as well as the algal bloom detection to provide insight on how various instrument performance parameters influence science and operational utility of OCX.

Monica Cook↗

Hybrid quantum dot-tin disulfide field-effect transistors with improved photocurrent and spectral responsivity

We report an improved photosensitivity in few-layer tin disulfide (SnS 2 ) field-effect transistors(FETs) following doping with CdSe/ZnS core/shell quantum dots(QDs). The hybrid QD-SnS 2 FET devices achieve more than 500% increase in the photocurrent response compared with the starting SnS 2 -only FET device and a spectral responsivity reaching over 650 A/W at 400 nm wavelength. The negligible electrical conductance in a control QD-only FET device suggests that the energy transfer between QDs and SnS 2 is the main mechanism responsible for the sensitization effect, which is consistent with the strong spectral overlap between QDphotoluminescence and SnS 2 optical absorption as well as the large nominal donor-acceptor interspacing between QD core and SnS 2 . Furthermore, we also find enhanced charge carrier mobility in hybrid QD-SnS 2 FETs which we attribute to a reduced contact Schottky barrier width due to an elevated background charge carrier density.

36 MATERIALS SCIENCE↗

Planck 2013 results. IX. HFI spectral response

The Planck High Frequency Instrument (HFI) spectral response was determined through a series of ground based tests conducted with the HFI focal plane in a cryogenic environment prior to launch. The main goal of the spectral transmission tests was to measure the relative spectral response (includingthe level of out-of-band signal rejection) of all HFI detectors to a known source of electromagnetic radiation individually. This was determined by measuring the interferometric output of a continuously scanned Fourier transform spectrometer with all HFI detectors. As there is no on-board spectrometer within HFI, the ground-based spectral response experiments provide the definitive data set for the relative spectral calibration of the HFI. Knowledge of the relative variations in the spectral response between HFI detectors allows for a more thorough analysis of the HFI data. The spectral response of the HFI is used in Planck data analysis and component separation, this includes extraction of CO emission observed within Planck bands, dust emission, Sunyaev-Zeldovich sources, and intensity to polarization leakage. The HFI spectral response data have also been used to provide unit conversion and colour correction analysis tools. While previous papers describe the pre-flight experiments conducted on the Planck HFI, this paper focusses on the analysis of the pre-flight spectral response measurements and the derivation of data products, e.g. band-average spectra, unit conversion coefficients, and colour correction coefficients, all with related uncertainties. Verifications of the HFI spectral response data are provided through comparisons with photometric HFI flight data. This validation includes use of HFI zodiacal emission observations to demonstrate out-of-band spectral signal rejection better than 10 8 . The accuracy of the HFI relative spectral response data is verified through comparison with complementary flight-data based unit conversion coefficients and colour correction coefficients. Furthermore, these coefficients include those based upon HFI observations of CO, dust, and Sunyaev-Zeldovich emission. General agreement is observed between the ground-based spectral characterization of HFI and corresponding in-flight observations, within the quoted uncertainty of each; explanations are provided for any discrepancies.

79 ASTRONOMY AND ASTROPHYSICS↗

Field measurements of the spectral response of natural waters

The spectral response (air-water interface reflectance and water-volume scattering) of turbid river water (99 mg/liter suspended solids) and relatively clear lake water (10 mg/liter suspended solids) was measured in situ with a field spectroradiometer. The influence of the river bottom on the spectral response of the water also was determined by using a modified Secchi disc approach. The results indicated that turbid river water had a higher spectral response than clear lake water (about 6 percent) in the red (0.6-0.7 micron) and near-infrared (0.7-0.9 micron) portions of the spectrum. Also, the reflectance characteristics of the river bottom did not influence the spectral response of the turbid river water when the water was deeper than 30 cm

Bartolucci, L. A.↗

Spectral response from blackbody measurements

Far-infrared and submillimeter detector responsivity and spectral response measurements can be performed simultaneously by sweeping the temperature of a cooled blackbody. Such measurements yield n simultaneous linear equations for n blackbody temperatures. Matrix inversion solutions are observed to fail due to a matrix ill-conditioned for inversion. However, an unconditionally convergent iterative solution can be performed. Results for a gallium-doped germanium detector are described.

Moore, W. J.↗

Calibration of the ROSAT HRI Spectral Response

The ROSAT High Resolution Imager has a limited (2-band) spectral response. This spectral capability can give X-ray hardness ratios on spatial scales of 5 arcseconds. The spectral response of the center of the detector was calibrated before the launch of ROSAT, but the gain decreases with time and also is a function of position on the detector. To complicate matters further, the satellite is 'wobbled', possibly moving a source across several spatial gain states. These difficulties have prevented the spectral response of the ROSAT High Resolution Imager (HRI) from being used for scientific measurements. We have used Bright Earth data and in-flight calibration sources to map the spatial and temporal gain changes, and written software which will allow ROSAT users to generate a calibrated XSPEC (an x ray spectral fitting package) response matrix and hence determine a calibrated hardness ratio. In this report, we describe the calibration procedure and show how to obtain a response matrix. In Section 2 we give an overview of the calibration procedure, in Section 3 we give a summary of HRI spatial and temporal gain variations. Section 4 describes the routines used to determine the gain distribution of a source. In Sections 5 and 6, we describe in detail how, the Bright Earth database and calibration sources are used to derive a corrected response matrix for a given observation. Finally, Section 7 describes how to use the software.

Prestwich, Andrea H.↗

Calibration of the ROSAT HRI Spectral Response

The ROSAT High Resolution Imager has a limited (2-band) spectral response. This spectral capability can give X-ray hardness ratios on spatial scales of 5 arcseconds. The spectral response of the center of the detector was calibrated before the launch of ROSAT, but the gain decreases-with time and also is a function of position on the detector. To complicate matters further, the satellite is "wobbled", possibly moving a source across several spatial gain states. These difficulties have prevented the spectral response of the ROSAT HRI from being used for scientific measurements. We have used Bright Earth data and in-flight calibration sources to map the spatial and temporal gain changes, and written software which will allow ROSAT users to generate a calibrated XSPEC response matrix and hence determine a calibrated hardness ratio. In this report, we describe the calibration procedure and show how to obtain a response matrix. In Section 2 we give an overview of the calibration procedure, in Section 3 we give a summary of HRI spatial and temporal gain variations. Section 4 describes the routines used to determine the gain distribution of a source. In Sections 5 and 6, we describe in detail how the Bright Earth database and calibration sources are used to derive a corrected response matrix for a given observation. Finally, Section 7 describes how to use the software.

Prestwich, Andrea↗

Spectral response measurements with white light bias

The spectral response of solar cells such as the CdS/Cu2S cell is non-linear with distinct quenching and enhancement bands. One possible technique to produce standardized solar efficiencies is to fold in spectral response with a standard solar spectrum. The spectral response of a cell was measured in a way which matched cell behavior under white light illumination. A technique was developed to measure the response of a cell to low intensity chopped monochromatic light while the cell is also illuminated with a white light bias corresponding to AMI.

Devaney, W.↗

Broad spectral response photodetector based on individual tin-doped CdS nanowire

High purity and tin-doped 1D CdS micro/nano-structures were synthesized by a convenient thermal evaporation method. SEM, EDS, XRD and TEM were used to examine the morphology, composition, phase structure and crystallinity of as-prepared samples. Raman spectrum was used to confirm tin doped into CdS effectively. The effect of impurity on the photoresponse properties of photodetectors made from these as-prepared pure and tin-doped CdS micro/nano-structures under excitation of light with different wavelength was investigated. Various photoconductive parameters such as responsivity, external quantum efficiency, response time and stability were analyzed to evaluate the advantage of doped nanowires and the feasibility for photodetector application. Comparison with pure CdS nanobelt, the tin-doped CdS nanowires response to broader spectral range while keep the excellect photoconductive parameters. Both trapped state induced by tin impurity and optical whispering gallery mode microcavity effect in the doped CdS nanowires contribute to the broader spectral response. The micro-photoluminescence was used to confirm the whispering gallery mode effect and deep trapped state in the doped CdS nanowires.

36 MATERIALS SCIENCE↗

Distribution of the Spectral Response of Cells in Silicon Modules - Mechanisms and Implications

Measurements of the spectral response of cells in a PV module can provide important insight into the physics of the device and are also needed for the accurate calibration of the performance of these devices using solar simulators. While techniques for measuring the spectral response of PV cells are well established, measurement of the spectral response of all cells in a module is not straightforward since in this case one has electrical access to a string of cells and not to cells individually. Here we present a new approach for testing the spectral response of individual cells in silicon modules that allows for the fast mapping of the response at different locations of the module. We show that in some cases the spectral response of different cells in a module can vary considerably and propose an underlying mechanism for this variation. We also discuss the implications of this observation for the uncertainty of the spectral correction and of the I SC calibration using a solar simulator.

modules↗

Solar cell spectral response characterization

The absolute spectral response of solar cells is reported in the 400-1000-nm spectral region. Measurements were performed using two different types of monochromatic sources: amplitude-stabilized CW laser lines and interference filters with an incandescent lamp. Both types of calibration procedures use electrical substitution radiometry as the basis of traceability to absolute SI units. The accuracy of the calibration is shown to be limited by the nonideal characteristics of the solar cells themselves, specifically spatial nonuniformities and nonlinearities induced by high light levels.

Zalewski, E. F.↗

Spectral response curve models applied to forest cover-type discrimination

The potential of remote sensing systems to provide a cost-effective inventory tool in the case of forest resources is currently of interest to a variety of natural resources management agencies. A number of studies have been performed regarding the use of Landsat data for mapping forest resources in Michigan. The present paper is concerned with current research, which has been directed toward the development and evaluation of computer-implemented classifications for the identification and characterization of coniferous forest types in Michigan's northern Lower Peninsula. Attention is given to the characteristic response curves from Landsat MSS data, spectral response curve models, and forest cover-type discrimination. It is found that spectral response curve models can be used to evaluate and explain the characteristic spectral responses of coniferous forest types on a snow-covered, winter Landsat scene.

Hudson, W. D.↗

High dynamic range measurement of spectral responsivity and linearity of a radiation thermometer using a super-continuum laser and LEDs

To realize the temperature scale above the freezing point of silver according to the definition of ITS-90, the dynamic range of the spectral responsivity is one of the most important factors which limit its uncertainty. When the residual spectral response at both side bands of a spectral band is not negligible, a significant uncertainty can be caused by a low dynamic range of the spectral responsivity measurement. In general, incandescent lamps are used to measure the spectral responsivity and the linearity. The dynamic range of the spectral responsivity measurement is often limited by a trade-off with the desired spectral resolution, which is less than 6 decades. Nonlinearity is another limiting fact of uncertainties of the temperature scale. Tungsten lamps have disadvantage in the nonlinearity measurements in terms of adjustability of radiance level and spectral selectivity. We report spectral responsivity measurements of which the measurable dynamic range is enhanced 50 times after replacing a QTH lamp with a super continuum laser. We also present a spectrally selected linearity measurement over a wide dynamic range using high-brightness light emitting diode arrays to observe a slight saturation of linearity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LANDSAT 9 Thermal Infrared Sensor 2 Spectral Response Test: Updates and Perspective

The Thermal Infrared Sensor 2 (TIRS-2) pre-launch spectral characterization at telescope and detector subsystem level provided a strong indication that the spectral response requirements will be met. Confidence in the validity of these results was strengthened through comparison to component-level measurements. This work reviews the modifications to the test setup to reduce spectral response uncertainties further in preparation for instrument-level testing. We developed a methodology to improve alignment repeatability of the upgraded system. Preliminary indications show that the spectral response will contribute a relatively small amount to the overall TIRS-2 radiometric uncertainty budget, which is expected to meet its radiometric requirements. Through spectral response testing, as part of a comprehensive pre-launch test program, TIRS-2 is expected to achieve the performance necessary for a variety of environmental applications.

spectral response↗

Landsat 9 TIRS-2 Spectral Response Test: Updates & Perspective

The Thermal Infrared Sensor 2 (TIRS-2) pre-launch spectral characterization at telescope and detector subsystem level provided a strong indication that the spectral response requirements will be met. Confidence in the validity of these results was strengthened through comparison to component-level measurements. This work reviews the modifications to the test setup to reduce spectral response uncertainties further in preparation for instrument-level testing. We developed a methodology to improve alignment repeatability of the upgraded system. Preliminary indications show that the spectral response will contribute a relatively small amount to the overall TIRS-2 radiometric uncertainty budget, which is expected to meet its radiometric requirements. Through spectral response testing, as part of a comprehensive pre-launch test program, TIRS-2 is expected to achieve the performance necessary for a variety of environmental applications.

Pearlman, Aaron↗

Analysis of bias voltage dependent spectral response in Ga{sub 0.51}In{sub 0.49}P/Ga{sub 0.99}In{sub 0.01}As/Ge triple junction solar cell

Spectral response measurement plays great role in characterizing solar cell device because it directly reflects the efficiency by which the device converts the sunlight into an electrical current. Based on the spectral response results, the short circuit current of each subcell can be quantitatively determined. Although spectral response dependence on wavelength, i.e., the well-known external quantum efficiency (EQE), has been widely used in characterizing multijunction solar cell and has been well interpreted, detailed analysis of spectral response dependence on bias voltage (SR −V{sub bias}) has not been reported so far. In this work, we have performed experimental and numerical studies on the SR −V{sub bias} for Ga{sub 0.51}In{sub 0.49}P/Ga{sub 0.99}In{sub 0.01}As/Ge triple junction solar cell. Phenomenological description was given to clarify the mechanism of operation matching point variation in SR −V{sub bias} measurements. The profile of SR−V{sub bias} curve was explained in detail by solving the coupled two-diode current-voltage characteristic transcend formula for each subcell.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An Initial Assessment of the Impact of System Spectral Response Parameters on Driving Ocean Color Applications for the GeoXO Ocean Color Instrument (OCX)

NOAA’s Geostationary Extended Observations (GeoXO) program is planning to include a hyperspectral ocean color instrument (OCX) in geostationary orbit slated for operations by the early 2030s. Shared international focus has led to a diverse legacy of space-based remote sensing ocean color missions that have and will continue to provide ocean color products into the future at a variety of spatial, temporal, and spectral resolutions. This work reports on an investigation of the impacts of system spectral response parameters on spectral shape and algal bloom detection for the planned OCX instrument. A dataset of high resolution (1 nm spectral sampling) in-situ spectra of red tide collected with an above water spectrometer, and associated K. brevis cell concentrations, were used to simulate OCX observations of varying system spectral response parameters. The OCX Performance Operational Requirements Document (PORD) level spectral resolution and sampling are varied concurrently and the location of band centers is varied independently. The impacts to the spectral shape using hyperspectral signature analysis, as well as the impacts to two heritage multispectral algal bloom detection algorithms – red band difference (RBD) and Karenia brevis bloom index (KBBI) – are assessed considering both changes in resolution/sampling and band center location. This work provides a quantitative assessment of the impacts of system spectral response requirements on both the spectral shape of observations as well as the algal bloom detection to provide insight on how various instrument performance parameters influence science and operational utility of OCX. Future work will seek to expand this analysis to include a larger dataset that considers additional water cases.

Monica Cook↗