Search NASASearch

SEARCH · Search NASA

Results for “SPECTROMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Annotation of DOM metabolomes with an ultrahigh resolution mass spectrometry molecular formula library

Current approaches to analyzing metabolomic data often rely on matching MS/MS fragmentation data to sparse libraries or databases. This approach results in limited identification of features, often with less than 10% of the dataset being annotated. A complementary approach is to assign molecular formula to features based on accurate mass measurements, but the platforms commonly used for metabolomics do not have the needed accuracy or resolving power to do this robustly, particularly for larger molecules. Using our newly modified analysis tool, CoreMS, we generated a library of molecular formula from pooled samples analyzed with LC-21T FT-ICR MS. This library successfully annotated approximately 53.2% of features identified from the exometabolome of marine diatom Phaeodactylum tricornutum – a nearly ten-fold increase over the 5.9% annotation rate achieved using a conventional MS/MS library matching approach. Using this FT-ICR MS library approach, we were able to differentiate differences in the exometabolome of P. tricornutum in iron replete and iron limited conditions, with 668 metabolites being differentially expressed (p < 0.05, 2 x intensity difference) under these conditions. The traditional MS/MS fragmentation-based annotation approach only annotated 61 of these metabolites, while our novel pipeline annotated 450 metabolites and revealed 12 metabolites that were significantly more abundant under low iron conditions. Our results demonstrate the utility of ultrahigh resolution mass spectrometry for generating more comprehensive and confident molecular annotations.

21T-FTICR-MS, CoreMS

Evaluation of a Reference-Free Collision Cross Section Calibration Strategy for Proteomics Using SLIM-Based High-Resolution Ion Mobility Spectrometry–Mass Spectrometry

Ion mobility spectrometry (IMS) is a gas-phase analytical technique that separates ions with different sizes and shapes and is compatible with mass spectrometry (MS) to provide an additional separation dimension. The rapid nature of the IMS separation combined with the high sensitivity of MS-based detection and the ability to derive structural information on analytes in the form of the property collision cross section (CCS) makes IMS particularly well-suited for characterizing complex samples in -omics applications. In such applications, the quality of CCS from IMS measurements is critical to confident annotation of the detected components in the complex -omics samples. However, most IMS instrumentation in mainstream use requires calibration to calculate CCS from measured arrival times, with the most notable exception being drift tube IMS measurements using multifield methods. The strategy for calibrating CCS values, particularly selection of appropriate calibrants, has important implications for CCS accuracy, reproducibility, and transferability between laboratories. The conventional approach to CCS calibration involves explicitly defining calibrants ahead of data acquisition and crucially relies upon availability of reference CCS values. In this work, we present a novel reference-free approach to CCS calibration which leverages trends among putatively identified features and computational CCS prediction to conduct calibrations post-data acquisition and without relying on explicitly defined calibrants. We demonstrated the utility of this reference-free CCS calibration strategy for proteomics application using high-resolution structures for lossless ion manipulations (SLIM)-based IMS-MS. In conclusion, we first validated the accuracy of CCS values using a set of synthetic peptides and then demonstrated using a complex peptide sample from cell lysate.

59 BASIC BIOLOGICAL SCIENCES

Advancing Aerosol Chemical Characterization and Vertical Profiling over the Southern Great Plains Using Uncrewed Aerial Sampling and Offline Aerosol Mass Spectrometry

Recent advancements in uncrewed aerial systems (UASs) and particulate matter (PM) analytical techniques have provided opportunities for atmospheric research. In this study, we deployed the Department of Energy’s fixed-wing ArcticShark UAS to examine PM 2.5 composition at varying altitudes─within and above the planetary boundary layer (PBL)─over the Southern Great Plains atmospheric observatory (SGP). A total of 22 flights were conducted across March, June, and August 2023. Composite filter samples were collected during each flight and analyzed with offline aerosol mass spectrometry (AMS), complemented by on-board real-time sensors and ground-based instrumentation, to provide a comprehensive view of regional aerosol characteristics. Results show clear vertical and seasonal differences in the aerosol composition. Relative to ground-level measurements, aloft samples exhibited shifts in the distribution of organic and inorganic PM, with the organic composition varying distinctly across seasons. Particulate organic nitrogen (ON) was elevated, with bulk compositions similar in March and June but strongly altered in August, likely driven by biomass burning and enhanced photochemical activity. Combined AMS and chemical ionization mass spectrometry analyses detected amines, amides, and amino acids. PM above the planetary boundary layer was enriched in oxidized organic aerosols, while ground-level PM contained higher nitrate and sulfate. Seasonal differences in aqueous-phase processing were also observed, which were strongest in March during persistent cloud cover and weaker in the drier August period, suggesting a shift from aqueous- to gas-phase SOA formation. In conclusion, these findings highlight the value of UAS in advancing PM measurements and vertical profiling of aerosol composition.

54 ENVIRONMENTAL SCIENCES

A universal language for finding mass spectrometry data patterns

Despite being information rich, the vast majority of untargeted mass spectrometry data are underutilized; most analytes are not used for downstream interpretation or reanalysis after publication. The inability to dive into these rich raw mass spectrometry datasets is due to the limited flexibility and scalability of existing software tools. Here, in this study, we introduce a new language, the Mass Spectrometry Query Language (MassQL), and an accompanying software ecosystem that addresses these issues by enabling the community to directly query mass spectrometry data with an expressive set of user-defined mass spectrometry patterns. Illustrated by real-world examples, MassQL provides a data-driven definition of chemical diversity by enabling the reanalysis of all public untargeted metabolomics data, empowering scientists across many disciplines to make new discoveries. MassQL has been widely implemented in multiple open-source and commercial mass spectrometry analysis tools, which enhances the ability, interoperability and reproducibility of mining of mass spectrometry data for the research community.

Damiani, Tito [Czech Academy of Sciences (CAS), Pr

Statistically-driven Experimental Design to Improve Reference-free Quantification of Small Molecules by Liquid Chromatography-Mass Spectrometry

Non-targeted analysis of small molecules and metabolites in unknown, complex samples using liquid chromatography-tandem mass spectrometry remains challenging. One of the main bottlenecks is the extensive unannotated regions of metabolomics mass spectrometry data, resulting in knowledge gaps. Small molecule annotation in mass spectrometry data has conventionally relied on reference standards and libraries for compound identification and confirmation, which can constrain compound identification to those molecules already known, thus limiting the ability to discover new knowledge and new markers. Retention time prediction can facilitate and expedite unknown compound identification in non-targeted analysis of complex metabolomics samples. Additionally, accurate retention time predictions can also inform sample mixture design for LC-MS/MS analyses. However, current machine learning-based methods for retention time prediction are typically developed for specific chromatographic platforms and are not generalizable across scales. And while technologies and methods to improve reference-free metabolite identification for more comprehensive annotation of unknowns has received much attention, development of the same for quantitation without reference standards has been much more limited, despite its importance in toxicological, environmental, food safety, forensics, and clinical applications. We believe that a reference-free quantitation strategy that exploits mass spectrometry data already collected for reference-free identification can provide much more insight on unknowns, and move the metabolomics field for more complete unknowns characterization. As such, we pursue two efforts to improve upon current state-of-the-art methods in non-targeted analysis: (1) machine learning-based retention time prediction and (2) statistical design of experiments framework for reference-free quantitation. In this work, we develop and demonstrate (1) a generalizable retention time prediction capability across chromatographic conditions and scales, and (2) a statistical design-based framework for response factor contribution elucidation and reference-free quantitation. Evaluation of our retention time prediction model, PrediToR, showed approximately 24% improvement over current models, and we observed approximately 10X improvement in concentration estimation accuracy from our statistical design-based response factor model over a primarily ionization efficiency-based model. We expect that future efforts to improve upon these new capabilities will further advance non-targeted analysis of small molecules towards truly reference-free metabolomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

230Th/234U radiochronometry for uranium materials by alpha spectrometry for nuclear forensics analysis

We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.

Macsik, Zsuzsanna [Los Alamos National Laboratory

High sensitivity measurement of femtogram-level 238 Pu by thermal ionization mass spectrometry with correction of background 238 U

Low-concentration plutonium isotopic measurements provide a valuable fingerprint to identify possible material origins in the context of environmental contamination monitoring, environmental tracing, nuclear safeguards, nuclear forensics, and treaty monitoring. Thermal ionization mass spectrometry (TIMS) has long been recognized as one of the most sensitive techniques for plutonium isotopic measurement, but has not generally been utilized for 238 Pu determination, especially at low concentrations, due to an isobaric interference from 238 U, prevalent as background. Here, this work demonstrates a new analytical technique for correction of background 238 U from the 238 Pu counts collected during a TIMS analysis. The technique takes advantage of the higher ionization temperature of U relative to Pu and uses a 235 U tracer added after plutonium purification chemistry for 238 U semi-quantitative determination. This technique has been successfully applied to the determination of 238 Pu concentration and the 238 Pu/ 239 Pu ratio in sample types including single-isotope standards, isotopic certified reference materials, matrix-containing environmental reference materials, and simulated nuclear detonation debris. The results have been directly compared on a sample-by-sample basis to alpha spectrometry results. The detection limit by this new technique is 0.23 fg 238 Pu, which was previously unachievable by mass spectrometry and is possible in around 1 h of analysis time post-chemistry compared to weeks of required counting time by alpha spectrometry (at the same atom amount). We also present original, high precision data for Pu isotope concentrations in IAEA-384, Fangataufa Sediment, including 242 Pu results for the first time. The new technique allows measurement of a key isotope, 238 Pu, that was previously not measured in small environmental or nuclear forensics collections.

238Pu

National User Resource for Biological Accelerator Mass Spectrometry

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science. As a NIGMS National Resource the National User Resource for Biological Accelerator Mass Spectrometry will help NIH funded scientists achieve a deeper understanding of the etiology of human health concerns by (1) enabling the quantification of pharmacokinetics and other molecular endpoints directly in humans; (2) offering the ability to conduct quantitative studies using biologics such as proteins or lipids, and thereby reducing the amount of radioisotope usage in biomedical labs; and (3) enabling more relevant studies of metabolic pathways in health and disease through the use of much lower, more biologically-relevant, concentrations of metabolic substrates in cells and intact organisms. Such studies support NIGMS’s basic biomedical research areas that contribute to the understanding of fundamental cellular and physiological principles and enable research supported by the Biophysics, Biomedical Technology, and Computational Biosciences (BBCB); Genetics and Molecular, Cellular, and Developmental Biology (GMCDB); Pharmacology, Physiology, Biological Chemistry (PPBC) and Training, Workforce Development, and Diversity (TWD) Divisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

National User Resource for Biological Accelerator Mass Spectrometry (Final Report)

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science. As a NIGMS National Resource the National User Resource for Biological Accelerator Mass Spectrometry will help NIH funded scientists achieve a deeper understanding of the etiology of human health concerns by (1) enabling the quantification of pharmacokinetics and other molecular endpoints directly in humans; (2) offering the ability to conduct quantitative studies using biologics such as proteins or lipids, and thereby reducing the amount of radioisotope usage in biomedical labs; and (3) enabling more relevant studies of metabolic pathways in health and disease through the use of much lower, more biologically-relevant, concentrations of metabolic substrates in cells and intact organisms. Such studies support NIGMS’s basic biomedical research areas that contribute to the understanding of fundamental cellular and physiological principles and enable research supported by the Biophysics, Biomedical Technology, and Computational Biosciences (BBCB); Genetics and Molecular, Cellular, and Developmental Biology (GMCDB); Pharmacology, Physiology, Biological Chemistry (PPBC) and Training, Workforce Development, and Diversity (TWD) Divisions. Over the next five years, our goals are to: 1. Improve the efficiency of operation for AMS measurements through installation of new interfaces to our AMS systems, technical modifications to improve gas accepting ion source efficiency and upgrading our data analysis software for improved ease of use and data reporting. 2. Increase the accessibility and visibility of ultra-sensitive 14C measurements for the biomedical research community by training of new investigators and expanding our national user base. 3. Provide high throughput, ultra-sensitive 14C analysis for the NIGMS and NIH user community.

47 OTHER INSTRUMENTATION

Predicting High‐Resolution Spatial and Spectral Features in Mass Spectrometry Imaging with Machine Learning and Multimodal Data Fusion

Recent advancements in molecular Mass Spectrometry Imaging have sparked interest in integrating high spatial resolution methods with molecular mass-spectrometry-based chemical imaging. Fusion-based algorithms have proven effective in generating high spatial-resolution molecular mass spectra. However, a significant challenge stems from the differing physical mechanisms underlying image generation and data upsampling techniques, potentially leading to discrepancies in integrated information channels. Integrating physical constraints into data processing workflows is essential to tackle this issue. In this study, we propose an innovative approach that merges data from Fourier transform ion cyclotron resonance (FTICR), time-of-flight matrix-assisted laser desorption/ionization, and time-of-flight secondary ion mass spectrometry imaging techniques. By leveraging FT-ICR's unparalleled spectral resolution and ToF-SIMS's exceptional spatial resolution, we achieve submicron spatial resolution, enabling the observation of intact molecular species with remarkable spectral precision. Canonical correlation analysis is employed to incorporate physical constraints. Through sophisticated image processing and machine learning techniques, the results of this fusion hold significant promise for advancing our comprehension of complex systems and unveiling concealed molecular intricacies.

canonical correlation analysis

Radioisotope dating of nuclear materials using cryogenic decay energy spectrometry

Cryogenic decay energy spectrometry provides high energy resolution and enables absolute decay counting, offering an alternative measurement technique for radiochronometry. A cryogenic decay energy spectrometry experiment was conducted using a magnetic microcalorimeter to determine the age of a plutonium sample. The energy resolution was measured at 0.05% from 5 to 6 MeV. The time since sample purification was determined using the measured concentration ratio of the 241 Am/ 241 Pu radiochronometer. Sample age estimates based on 241 Pu alpha-decay and beta-decay counts, along with 241 Am decay counts, align with the expected sample age within expanded uncertainty (k = 2), supporting the accuracy of cryogenic decay energy spectrometry as a radiochronometric method.

and nuclear chemistry

PeakQC: A Software Tool for Omics-Agnostic Automated Quality Control of Mass Spectrometry Data

Mass spectrometry is broadly employed to study complex molecular mechanisms in various biological and environmental fields, enabling 'omics' research such as proteomics, metabolomics, and lipidomics. As study cohorts grow larger and more complex with dozens to hundreds of samples, the need for robust quality control (QC) measures through automated software tools becomes paramount to ensure the integrity, high quality, and validity of scientific conclusions from downstream analyses and minimize the waste of resources. Since existing QC tools are mostly dedicated to proteomics, automated solutions supporting metabolomics are needed. To address this need, we developed the software PeakQC, a tool for automated QC of MS data that is independent of omics molecular types (i.e., omics-agnostic). It allows automated extraction and inspection of peak metrics of precursor ions (e.g., errors in mass, retention time, arrival time) and supports various instrumentations and acquisition types, from infusion experiments or using liquid chromatography and/or ion mobility spectrometry front-end separations and with/without fragmentation spectra from data-dependent or independent acquisition analyses. Diagnostic plots for fragmentation spectra are also generated. Here, in this paper, we describe and illustrate PeakQC’s functionalities using different representative data sets, demonstrating its utility as a valuable tool for enhancing the quality and reliability of omics mass spectrometry analyses.

47 OTHER INSTRUMENTATION

Emerging protein sequencing technologies: proteomics without mass spectrometry?

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been a leading method for proteomics for 30 years. Advantages provided by LC-MS/MS are offset by significant disadvantages, including cost. Recently, several non-mass spectrometric methods have emerged, but little information is available about their capacity to analyze the complex mixtures routine for mass spectrometry. Areas Covered: We review recent non-mass-spectrometric methods for sequencing proteins and peptides, including those using nanopores, sequencing by degradation, reverse translation, and short-epitope mapping, with comments on bioinformatics challenges, fundamental limitations, and areas where new technologies will be more or less competitive with LC-MS/MS. In addition to conventional literature searches, instrument vendor websites, patents, webinars, and preprints were also consulted to give a more up-to-date picture. Expert Opinion: Many new technologies are promising. However, demonstrations that they outperform mass spectrometry in terms of peptides and proteins identified have not yet been published, and astute observers note important disadvantages, especially relating to the dynamic range of single-molecule measurements of complex mixtures. Still, even if the performance of emerging methods proves inferior to LC-MS/MS, their low cost could create a different kind of revolution: a dramatic increase in the number of biology laboratories engaging in new forms of proteomics research.

59 BASIC BIOLOGICAL SCIENCES

Minimum Detectable Intakes and Doses for Uranium Bioassays—Comparison between Alpha Spectrometry and ICP-MS

Naturally occurring uranium complicates monitoring for occupational exposures. There are several retroactive methods that can be used to monitor for occupational exposures, with benefits and drawbacks to each. Analysis of uranium in urine by mass spectrometry and alpha spectrometry is compared, and methods of determining an occupational exposure are presented. Furthermore, the minimum detectable concentrations from each analysis and a method for intake determination based on the analytical results are compared for various solubility types and mixtures. Mass spectrometry with radiochemical separation was found to be the most sensitive analysis for detecting occupational exposures to anthropogenic mixtures based on minimum detectable doses calculated from the proposed method for intake determination.

bioassay

Algorithms and file structures to extend and enhance liquid chromatography and ion mobility mass spectrometry workflows (CRADA Final Report)

The purpose of this project was to continue supporting customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based protein and metabolite characterization. PNNL worked with Agilent to design, implement, evaluate, and demonstrate new algorithms and integrated them as functionalities into the PNNL-PreProcessor software. The project augmented PNNL’s capabilities to analyze complex proteomics and metabolomics samples. These capabilities are directly beneficial to DOE and PNNL efforts to characterize and analyze these compounds in microbial and plant communities. The project assisted Agilent in further developing improved instrument-software solutions combining liquid chromatography and ion mobility with mass spectrometry for widespread applications in life sciences and other fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Rapid native single cell mass spectrometry

A method for analyzing single cells by mass spectrometry includes the steps of providing a plurality of cells in a liquid medium and placing the cells and liquid medium in a single cell isolation and ejection system. Liquid medium containing a single cell is released from the single cell isolation and ejection system. The liquid medium and single cell are captured in a capture probe containing a flowing capture probe solvent. The cell is lysed by a lysis inducer in the capture probe to disperse single cell components into the medium. The lysed single cell components are transported to a mass spectrometer, where the lysed single cell components entering the mass spectrometer are spatially and temporally separated from any dispersed components of another single cell from the sample entering the mass spectrometer. Mass spectrometry is conducted on the lysed single-cell components. A system for analyzing single cells by mass spectrometry is also disclosed.

Cahill, John F.

High and Ultra-High Temperature Reaction Kinetics by Single Nanoparticle Mass Spectrometry

Methodology is presented for non-destructive, optically-detected single nanoparticle (NP) mass spectrometry, with the goal of extracting surface reaction kinetics for single NPs at high temperatures. Methods for determining the NP charge, mass, and temperature as a function of time are discussed, and the data are used to extract both the absolute kinetics for mass change, as well as the efficiencies of the surface processes that cause them. Factors that contribute to the uncertainties in absolute and relative mass determination, and in the resulting kinetic parameters, are discussed. The method allows the NP-to-NP variations in initial reactivity to be measured directly, along with the time evolution of reactivity resulting from NP structural/compositional changes that occur under reaction conditions. The strengths and limitations of single nanoparticle mass spectrometry as a high temperature surface kinetics tool are discussed in the context of sublimation and O2 oxidation kinetics experiments for single hafnium (Hf) NPs at temperatures ranging above 2400 K. The Hf oxidation kinetics are compared to analogous oxidation experiments for silicon, graphite, and carbon black NPs. In all four cases, the oxidation chemistry was dominated by processes that result in net mass loss, and the distinct mechanisms responsible are discussed. All four NPs also eventually passivated, i.e., the efficiencies for oxidative etching decreased by at least two orders of magnitude, relative to the initial efficiencies. Furthermore, the passivation mechanisms, which are quite different for carbon, compared to silicon or hafnium, are discussed. Carbon NP passivation is attributed to structural isomerization leading to fully coordinated, fullerene-like NP surfaces, while for silicon and hafnium, passivation results from delayed formation of an oxide layer, triggered by accumulation of oxygen in the NP sub-surface region.

36 MATERIALS SCIENCE