Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPECTROPHOTOMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Spectrophotometry of comets at optical wavelengths

Techniques for spectrophotometry of comets are discussed, and results are reviewed for line and continuum spectrophotometry of comets at optical wavelengths. The techniques considered include photographic spectroscopy and spectrophotometry, photoelectric spectrophotometry, and methods based on the use of image dissector scanners, Fourier-transform instruments, and Fabry-Perot spectrometers. Results are summarized for the study of cometary emission features due to C2, CN, CH, OH, NH, C3, NH2, O, H, CO(plus), and H2O(plus). Relative abundances of various species in comets are examined, along with continuum spectrophotometry of the nuclei, comas, and tails of comets.

Ahearn, M. F.↗

Neptunium redox speciation and determination of its total concentration in dissolved fuel simulant solutions by spectrophotometry

Here, two new approaches to measure Np concentration in dissolved used nuclear fuel simulant (aqueous feed for PUREX process) by spectrophotometry are developed. The first approach is based on chemical reduction of Np in the feed to its tetravalent state using ascorbic acid with simultaneous conversion of Pu(IV) to Pu(III). Interfering effects from light absorbing fission and corrosion products are accounted for by measuring optical absorbance spectrum of aqueous raffinate after extraction of U, Np, and Pu by tributyl phosphate in dodecane. The second approach uses no chemical treatment at all and relies on spontaneous valency adjustment of Np to Np(V) by dilution of the feed with water to reduce its acidity to low decimolar range of nitric acid concentration. Results of Np determination in the feed by spectrophotometry are in good agreement with its concentration measured by ICP-MS.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Slitless spectrophotometry with forward modelling: Principles and application to measuring atmospheric transmission

Context.In the next decade, many optical surveys will aim to answer the question of the nature of dark energy by measuring its equation-of-state parameter at the per mill level. This requires trusting the photometric calibration of the survey with a precision never reached so far on many sources of systematic uncertainties. The measurement of the on-site atmospheric transmission for each exposure, or for each season or for the full survey on average, can help reach the per mill precision for the magnitudes. Aims.This work aims at proving the ability to use slitless spectroscopy for standard-star spectrophotometry and its use to monitor on-site atmospheric transmission as needed, for example, by theVera C. RubinObservatory Legacy Survey of Space and Time supernova cosmology program. We fully deal with the case of a disperser in the filter wheel, which is the configuration chosen in theRubinAuxiliary Telescope. Methods.The theoretical basis of slitless spectrophotometry is at the heart of our forward-model approach to extract spectroscopic information from slitless data. We developed a publicly available software calledSpectractor, which implements each ingredient of the model and finally performs a fit of a spectrogram model directly on image data to obtain the spectrum. Results.We show through simulations that our model allows us to understand the structure of spectrophotometric exposures. We also demonstrate its use on real data by solving specific issues and illustrating that our procedure allows the improvement of the model describing the data. Finally, we discuss how this approach can be used to directly extract atmospheric transmission parameters from the data and thus provide the base for on-site atmosphere monitoring. We show the efficiency of the procedure in simulations and test it on the limited available data set.

Astronomy & Astrophysics↗

Feasibility Study of Spectrophotometry to Support a Promethium Production Program at ORNL

Optical spectroscopy can be used to optimize analytical measurements for lanthanide elements and provide real-time feedback to help guide production operations. This study evaluates spectrophotometry for the determination of samarium (Sm 3+ ) and neodymium (Nd 3+ ) in aqueous and organic solutions at concentrations relevant to a promethium (Pm) program separation scheme. Detection limits approached 0.5 mM for Nd 3+ and 2 mM for Sm 3+ using Ocean Insight spectrophotometers. Additionally, Sm 3+ detection limits using laser fluorescence spectra for Sm 3+ approached single ppm (mg∙L -1 ) levels. An absorption spectrum containing Nd and Pm is also reported and discussed. This work demonstrates proofof-principle concepts for applying spectrophotometry to online monitoring applications in support of a future Pm production program.

47 OTHER INSTRUMENTATION↗

Optical spectrophotometry of comet Tempel 2 far from the sun

With the advent of mission planning for spacecraft encounters with comets in the 1980s, the lack of basic data on cometary nuclei has become quite apparent and a real problem. More effort is needed on all comets, with special attention given to probable space flight targets such as Tempel 2. The paper presents medium-spectral-resolution spectrophotometry of P/Tempel 2, made at heliocentric distances of 2.66 and 3.02 AU on two dates in 1978. It is shown that optical spectrophotometry of comet Tempel 2 near 3 AU heliocentric distance places strict limits on its activity, the modeled CN production rate having an upper limit of 6 times 10 to the 21st molecules per sec. The observations of P/Tempel 2 are compatible with a bare nucleus of 1.6 km radius (geometric albedo = 0.15) and somewhat redder than the sun.

Spinrad, H.↗

Airborne stellar spectrophotometry from 1.2 to 5.5 microns - Absolute calibration and spectra of stars earlier than M3

Airborne infrared spectrophotometry (1.2-5.5 microns, 1.5% resolution) is presented for 13 stars which have been extensively used as infrared calibration objects: alpha Lyr, alpha CMA, alpha UMi, beta Dra, and mu Her; the K giants beta Gem, alpha UMa, alpha Boo, gamma-1 And, and alpha Tau; and the M giants beta And, beta Peg, and alpha Cet. These spectra, obtained using NASA's Kuiper Airborne Observatory and Lear Jet Observatory, are virtually free of the interfering effects of terrestrial absorptions. Absolute calibration of the spectrophotometry was based on the theoretical model of alpha Lyr by Schild, Peterson, and Oke (1971), which fits photometric measurements at shorter wavelengths. The resulting flux densities are compared with previous ground-based photometry.

Strecker, D. W.↗

Preparation of Ion Exchange Films for Solid-Phase Spectrophotometry and Solid-Phase Fluorometry

Atomic spectroscopy has dominated the field of trace inorganic analysis because of its high sensitivity and selectivity. The advantages gained by the atomic spectroscopies come with the disadvantage of expensive and often complicated instrumentation. Solid-phase spectroscopy, in which the analyte is preconcentrated on a solid medium followed by conventional spectrophotometry or fluorometry, requires less expensive instrumentation and has considerable sensitivity and selectivity. The sensitivity gains come from preconcentration and the use of chromophore (or fluorophore) developers and the selectivity is achieved by use of ion exchange conditions that favor the analyte in combination with speciative chromophores. Little work has been done to optimize the ion exchange medium (IEM) associated with these techniques. In this report we present a method for making ion exchange polymer films, which considerably simplify the solid-phase spectroscopic techniques. The polymer consists of formaldehyde-crosslinked polyvinyl alcohol with polyacrylic acid entrapped therein. The films are a carboxylate weak cation exchanger in the calcium form. They are mechanically sturdy and optically transparent in the ultraviolet and visible portion of the spectrum, which makes them suitable for spectrophotometry and fluorometry.

Hill, Carol M.↗

Acid–Base Properties of Azo Dyes in Solution Studied Using Spectrophotometry and Colorimetry

Colorimetry and spectrophotometry with chemometric data processing were used to study the acid–base properties of azo dyes in aqueous solution. The capabilities of both methods were compared. Ionization constants of all the functional groups of the azo compounds studied could be determined relative to the change in the specific color difference depending on the acidity of the medium. The colorimetric functions of ion-molecular forms of azo compounds used as an analytical signal allow us to obtain complete information on the acid–base equilibrium in a wide acidity range.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rational Evaluation and Cycle Life Improvement of Quinone-Based Aqueous Flow Batteries Guided by In-Line Optical Spectrophotometry

We measure electrolyte concentration and state-of-charge in real time in an operating aqueous anthraquinone-based flow battery using in-line optical spectrophotometry. By capitalizing on the linear transition in absorption spectra between oxidized and reduced states, we show how discontinuous capacity fade rates in redox flow batteries can be caused by a transition from one capacity-limiting electrolyte to the other, which is caused by reactant crossover. With this insight, we demonstrate an electrolyte-balancing scheme, which can be broadly applicable to flow battery systems with asymmetric electrolyte crossover rates.

25 ENERGY STORAGE↗

A NEW CONCEPT FOR SPECTROPHOTOMETRY OF EXOPLANETS WITH SPACE-BORNE TELESCOPES

We propose a new concept for the spectral characterization of transiting exoplanets with future space-based telescopes. This concept, called densified pupil spectroscopy, allows us to perform high, stable spectrophotometry against telescope pointing jitter and deformation of the primary mirror. This densified pupil spectrometer comprises the following three roles: division of a pupil into a number of sub-pupils, densification of each sub-pupil, and acquisition of the spectrum of each sub-pupil with a conventional spectrometer. Focusing on the fact that the divided and densified sub-pupil can be treated as a point source, we discovered that a simplified spectrometer allows us to acquire the spectra of the densified sub-pupils on the detector plane−an optical conjugate with the primary mirror−by putting the divided and densified sub-pupils on the entrance slit of the spectrometer. The acquired multiple spectra are not principally moved on the detector against low-order aberrations such as the telescope pointing jitter and any deformation of the primary mirror. The reliability of the observation result is also increased by statistically treating them. Our numerical calculations show that because this method suppresses the instrumental systematic errors down to 10 ppm under telescopes with modest pointing accuracy, next generation space telescopes with more than 2.5 m diameter potentially provide opportunities to characterize temperate super-Earths around nearby late-type stars through the transmission spectroscopy and secondary eclipse.

79 ASTRONOMY AND ASTROPHYSICS↗