Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPEX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Simulating ‘Two Ribbon’ Type Solar Flares [Slides]

The underlying mechanism in solar flares in a process known as magnetic reconnection. This astrophysical process is when magnetic field lines, running anti-parallel, break and reconnect. The change in configuration of field lines results in an explosive release of energy as the leftover magnetic energy is converted to kinetic and thermal energies. In this project, we are using an astrophysical magnetohydrodynamic (MHD) simulation code known as Athena++ with a reconnection problem generator file created by Li et al. 2018. Our current research is to successfully implement a radiative cooling term into the MHD equations as it could have important physical effects on the plasma. We use Klimchuk et al. 2008 and SPEX_DM as our chosen cooling functions. The results from the SPEX_DM function show there is a condensation forming that we had predicted but had not seen before with our simulation code. We will continue to analyze the SPEX_DM function and potentially implement thermal conduction.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of processing conditions on flash sintering of commercial ZrN

Flash sintering (FS) is a potentially rapid and low-cost manufacturing technique for advanced ceramics. There are still many unknowns about ceramic FS, especially for highly conductive high-temperature ceramics (HTC), which often display decreased bulk conductivity with increasing temperature. This study qualitatively characterizes the flash behavior of highly conductive HTC materials using zirconium nitride (ZrN) as an example. The effects of processing parameters (e.g., DC voltage/electrical field strength, voltage ramp rate, post-flash holding time, mechanical pressure, sample milling, and choice of electrode materials) on ZrN flash behavior are also qualitatively studied and linked to samples microstructure and hardness. It is observed that best densification was achieved using 5 min Spex-milled ZrN powder under 25 MPa of applied pressure and constant 8 V DC. The potential mechanism for ZrN FS and the similarity and difference from FS of conventional oxides like YSZ have been proposed based on experimental observations, and the directions for future research are also pointed out.

Flash Sintering↗

Delving into the depths of NGC 3783 with XRISM V. Broad-band modelling of ionized outflows

The Seyfert 1 galaxy NGC 3783 hosts a multi-phase warm absorber (WA) that has been extensively studied in the X-ray band. High-resolution spectra from 2000−2001 revealed a complex outflow with multiple ionization and velocity components. Two decades later, new XMM-Newton and XRISM observations allow us to investigate the long-term evolution of these outflows. We performed joint spectral modelling of the XMM-Newton /RGS and XRISM/Resolve time-averaged spectra using the pion photoionization code within SPEX. We derived the ionization parameter, column density, turbulent velocity, and outflow velocity for each absorption component, and investigated their thermal stability and absorption measure distribution (AMD) to characterize the physical and dynamical properties of the WA in NGC 3783 in 2024. We compared these results with the 2000−2001 epoch to assess long-term variability, stability, and possible changes in the absorber population. We identify eight WA components spanning log ξ = 1.08 − 3.38 and outflow velocities of 480−1230 km s −1 . The ranges of column densities and turbulent velocities remain broadly consistent with the WAs from 2000−2001, but the earlier data contained more low-ionization, high-velocity components. The total column density of all the outflows in 2024 is 1.5 times larger than in 2000−2001, which means that it has been replenished by fresh material. The dominant unresolved transition array (UTA) absorber (component B3) has increased its column density by a factor of three while maintaining a similar ionization parameter. The WAs in NGC 3783 have undergone significant structural and dynamical evolution over the past 24 years.

79 ASTRONOMY AND ASTROPHYSICS↗

Total metals, carbon, nitrogen & anion concentration data; Slate River & East River floodplains, Crested Butte, CO; May 2022-October 2022

This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗