At least 19 records

Process Design and Techno-Economic Analysis of the Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Biomass

This work describes the process design and techno-economic analysis (TEA) of the modular stage pressurized oxy-combustion (SPOC) power plant for biomass firing and coal-biomass co-firing. The SPOC process was modelled using Aspen Plus®, and largely based on a previous model designed by this group for SPOC coal firing. To enable comparison with current National Energy Technology Laboratory (NETL) Bio-Energy Carbon Capture and Storage (BECCS) studies, a 550 MWe SPOC power plant with a supercritical Rankine cycle (241 bar, 593°C, and 593°C), and 90% carbon capture was modeled, and hybrid poplar biomass was chosen. Two cases were evaluated, namely 100% biomass (carbon negative) and 25% biomass co-firing (carbon neutral), and the 100% Powder River Basin coal firing case was chosen for comparison purposes. In the SPOC process, oxygen is produced via a cryogenic air separation unit (ASU) and the heat generated from the compression of air is integrated into the steam cycle and utilized for boiler feed water regeneration. Unique to the SPOC process, the boilers are arranged in a series-parallel configuration, with minimized flue gas recirculation. The flue gas is cooled and scrubbed in the direct-contact cooler (DCC) column, and the water leaving the bottom of the DCC is at a sufficiently high temperature that it can be used for boiler feed water heating, improving plant thermal efficiency. The SPOC efficiencies were above the BECCS cases with capture, and no efficiency penalty on the SPOC plant was observed with an increase of biomass in the mix mostly due to the higher oxygen content in biomass that resulted in lower oxygen requirement from the ASU, and the higher moisture in biomass that due to the key benefit of the SPOC process can be partially recovered as latent heat.

Magalhaes, Duarte↗

Enabling Staged Pressurized Oxy Combustion (SPOC): Improving Flexibility and Performance at Reduced Cost

Staged Pressurized Oxy-Combustion (SPOC) is a coal combustion power technology being developed by Washington University in St. Louis (WUSTL) that offers the potential to deliver low-carbon power at a reduced cost. Traditional oxy-combustion plants remove most of the nitrogen in air prior to combustion, thereby burning fuel in oxygen instead of air, producing a flue gas containing primarily CO 2 and water that allows relatively simple CO 2 capture at amounts > 90%. This technology relies on flue gas recycle (FGR) to reduce the peak temperature and radiation that would otherwise occur in a fuel/oxygen only flame. SPOC reduces the peak temperatures of combustion by utilizing two or more pressurized boiler modules connected in series to produce fuel staging; hence, only a portion of the fuel is combusted in any given furnace module. This means that the thermal energy released at each stage can be captured and removed from the gases prior to subsequent stages, when more fuel is introduced. This allows the SPOC process to operate with minimal FGR, avoiding the associated efficiency losses and additional costs. The SPOC process operates at an elevated gas-side pressure, reducing boiler size, enhancing heat transfer to achieve a compact boiler configuration as compared to an atmospheric-pressure boiler design, and allowing the recovery of the latent heat of the water from the flue gas at a temperature useful to the steam cycle. The resultant net efficiency of the system is up to 6 percentage points greater than traditional atmospheric-pressure oxy-combustion, representing a step-change improvement over first-generation oxy-combustion technologies. WUSTL has teamed up with the Electric Power Research Institute, Inc., American Air Liquide, Inc., Doosan Babcock Limited, and the U.S. Department of Energy to develop a practicable and workable boiler design concept associated with the application of SPOC. In particular, due to the staged nature of the heat release, the team has identified the potential for enhanced process flexibility for controlling power generation over a wider load range than is normally available to conventional coal-fired power plants. Improved flexibility is a critical need as coal power plants are being tasked with providing grid stability to balance the growth of intermittent renewables. Not only is flexible operation important, achieving efficient power generation at reduced loads will be key as the plants are likely to operate in this regime for significant periods of time as more renewables become available. At reduced loads, coal-fired steam generators typically face challenges in maintaining temperature control of the reheat steam and to a lesser extent the main steam due to the heat transfer characteristics of these circuits when flue gas quantities are lower. This results in inefficient operation, both in terms of the boiler efficiency and steam turbine heat rate. Since the SPOC process can be configured to deliver targeted heat input to each boiler circuit by adjusting the relative fuel firing rate of each stage, better temperature control can be achieved during dynamic conditions. Oxygen supply flexibility is also a key consideration for the overall flexibility of the SPOC process given the operating constraints of conventional air separation units. The boiler design concept assessment is being carried out to identify the maximum permissible compactness of the SPOC boiler heating surfaces. The assessment will determine the minimum overall height that will deliver appropriate tube operating metal temperatures at full load and achieve rated reheat steam temperatures at low operating loads, balanced against the needs of efficient coal combustion, and the resultant slagging and ash environments. The design parameters are being validated by combustion testing in the 100-kWth pressurized combustion test rig at WUSTL. Testing results and model validation that form the basis of a full-scale boiler design that will encompass both efficiency and flexibility improvements over conventional oxy-combustion processes will be presented.

20 FOSSIL-FUELED POWER PLANTS↗

Process Design and Techno-Economic Analysis of the Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Biomass

This work describes the process design and techno-economic analysis (TEA) of the modular SPOC power plant for biomass firing and coal-biomass co-firing. Two Rankine cycles were considered: a supercritical steam cycle (242 bar, 593°C, 593°C) with 550 MWe net output and a subcritical cycle (166 bar, 566°C, 566°C) with 200 MWe net output. For both cases, 95% carbon capture was modeled, and hybrid poplar biomass was chosen to generate carbon-negative power. In addition, the supercritical 500 MWe case included a 25% biomass co-firing (carbon neutral) case. For both cycles, a 100% Powder River Basin coal firing case was used for comparison purposes. In the SPOC process, oxygen is produced via a cryogenic air separation unit (ASU) and the heat generated from the compression of air is integrated into the steam cycle and utilized for boiler feed water pre-heating. Unique to the SPOC process, the boilers are pressurized and arranged in a series-parallel configuration, with minimized flue gas recirculation. The flue gas is cooled and scrubbed in the direct-contact cooler (DCC) column, and the moisture in the flue gas is condensed, leaving the bottom of the DCC at a sufficiently high temperature such that it can be used for boiler feed water pre-heating, improving plant thermal efficiency. Following drying and purification, CO2 in the flue gas is at the purity required for storage or utilization. The performance data were obtained from process modelling via Aspen Plus®. The stream data from Aspen Plus® were used as an input for the AACE Class 5 cost study. Ultimately, the capital costs, Levelized Cost of Electricity (LCOE), and cost of CO2 captured and avoided were obtained. The HHV efficiency of the carbon negative 550 MWe supercritical SPOC case (34.8%) was clearly above those reported by NETL for the BECCS baseline cases of supercritical pulverized coal with capture (B12B, 31.5%) and the 49% biomass co-firing case with capture (PA3, 29.2%). The HHV efficiency of the carbon-negative subcritical plant is also higher than the subcritical baseline PC plant with capture (case B11B.95) presented by NETL (32% vs 29.7%). The LCOE for the SPOC 100% biomass case was similar to the LCOE for the BECCS 49% biomass with carbon capture case ($147/MWh), and the SPOC carbon neutral case LCOE was lower ($110/MWh) than the cost for the NETL baseline SC coal firing case with 90% carbon capture ($114/MWh).

Magalhaes, Duarte↗

Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Coal and Biomass – Integration of Combustor Boiler and DCC

Critical to the future of power generation is the development of a power plant that will be capable of flexible operation to meet the needs of the modern grid, providing resilient, low-emissions power to a grid that is increasingly seeing a large penetration of intermittent wind and solar. The modular Staged, Pressurized Oxy-Combustion (SPOC) process envisioned by and under development at Washington University in St. Louis (WUSTL) has the potential to achieve these goals. The process offers: 1) a modular plant design for improved operational flexibility; 2) fuel-staging combined with pressurized oxy-combustion, which leads to smaller plant size, higher plant efficiency, and lower cost for pollutant and greenhouse gas removal compared with traditional carbon-capture equipped coal power plants; and 3) small modular boilers and pollutant removal units that can be fabricated in shop and assembled on site, further reducing plant capital costs. Under DOE's support (DE-FE0031925), WUSTL is advancing the development of the critical components for the SPOC power plant, including the integrated combustion system and the direct contact cooler (DCC) from Technology Readiness Level (TRL) 4 to TRL-5, which would allow these technologies to be subsequently incorporated into a pilot plant. This talk will present an overview of the SPOC technology, CFD modeling and validation for burner and boiler development, and recent results to evaluate critical components for system integration needed to advance its TRL.

Magalhaes, Duarte↗

Development of the Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Coal and Biomass

Critical to the future of power generation is the development of a power plant that will be capable of flexible operation to meet the needs of the modern grid, providing resilient, low-emissions power to a grid that is increasingly seeing a large penetration of intermittent wind and solar. The modular Staged, Pressurized Oxy-Combustion (SPOC) process envisioned by and under development at Washington University in St. Louis (WUSTL) has the potential to achieve these goals. The process offers: 1) a modular plant design for improved operational flexibility; 2) fuel-staging combined with pressurized oxy-combustion, which leads to smaller plant size, higher plant efficiency, and lower cost for pollutant and greenhouse gases removal compared with traditional carbon-capture equipped coal power plants; and 3) small modular boilers and pollutant removal units that can be fabricated in shop and assembled on site, further reducing plant capital costs. Under DOE's support (DE-FE0031925), WUSTL is advancing the development of the critical components for the SPOC power plant, including the integrated combustion system and the direct contact cooler (DCC) from Technology Readiness Level (TRL) 4 to TRL-5, which would allow these technologies to be subsequently incorporated into a pilot plant. This talk will present an overview of the SPOC technology, CFD modeling and validation for burner and boiler development, and recent results to evaluate critical components needed to advance its TRL.

Magalhaes, Duarte↗

Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Coal and Biomass – Integration of Combustor Boiler and DCC

Utilities and grid operators worldwide are under significant pressure to incorporate intermittent renewable sources while strategizing on how to maintain the necessary stability and reliability of the grid. The development of a power plant which will be capable of flexible operation to meet the needs of the grid as more intermittent sources like wind and solar energy are incorporated is key to maintain the reliability of the grid. Through the use of innovative and cutting-edge technologies that improve efficiency and reduce carbon emissions, and being small compared to today's conventional utility-scale power plants, the modular Staged, Pressurized Oxy-Combustion (SPOC) process envisioned by and under development at Washington University in St. Louis (WUSTL) has the potential to achieve these goals. Specifically, the process offers: 1) a modular plant design that allows for better operational flexibility; 2) the utilization of fuel-staging and pressurized oxy-combustion, resulting in smaller plant size, improved plant efficiency, and reduced costs for pollutant and CO2 removal compared to traditional power plants with post-combustion capture technology; and 3) the use of small modular boilers and pollutant removal units that can be constructed off-site leading to reduced capital costs for the plant. WUSTL is advancing the development of the critical components for the SPOC power plant, including the integrated combustor-boiler system and the direct contact cooler. To demonstrate the boiler convective section and to obtain critical data for commercial-scale pressurized boiler design, a simulated convective heat transfer boiler test section was designed and integrated with the combustor (radiant section). A direct contact cooler (DCC) was integrated with the combustor-boiler to demonstrate the dynamic operation of the integrated system and the performance of the DCC, including the efficiency for simultaneous removal of NOx and SOx. This talk will present an update on the evaluation of the critical components for system integration, including heat transfer data from the simulated boiler, scrubbing efficiency for the DCC under different operating conditions, and CFD modeling and validation for burner and boiler development.

Magalhaes, Duarte↗

Studying-Polymers-on a-Chip (SPOC)

Code developed for Studying-Polymers-on a-Chip (SPOC) project LDRD-LW-006. Public release needed for sharing code for publication.

Jimenez, JayvicCristian [Lawrence Livermore Nation↗

Enabling Staged Pressurized Oxy-Combustion: Improving Flexibility and Performance at Reduced Cost

Introduction: The staged pressurized oxy-combustion (SPOC) process, developed by Washington University in St. Louis (WUSTL), is an oxy-combustion carbon capture technology that employs a steam power cycle to generate electricity. As with atmospheric-pressure oxy-combustion processes, carbon dioxide (CO 2 ) capture rates of 90% or higher can be achieved. The staged-combustion approach of the SPOC process, when operated at elevated gas pressure, allows for near elimination of flue gas recycle (FGR) and leads to significant improvements in efficiency and reduced costs. The primary goal of this project was to investigate the potential for SPOC for flexible operation beyond the capabilities of conventional coal-fired power plants, particularly those employing carbon capture and storage (CCS). Oxy-combustion differs from conventional coal combustion in that the combustion of coal is carried out using oxygen as opposed to air. The resultant flue gas is a mixture of primarily CO 2 and water, greatly simplifying CO 2 capture. As SPOC does the oxy-combustion process under pressure, it is higher efficiency and lower cost than atmospheric oxy-combustion. The project was led by the Electric Power Research Institute, Inc., with the assistance of WUSTL, Doosan Babcock (DBL – boiler plant original equipment manufacturer), and Air Liquide (AL – air separation experts). The specific objectives of the project were to: (1) Evaluate the SPOC concept and develop a risk-based approach to the heating surface layout ensuring that performance (gas and steam side), manufacturing, transportation, and plant erection considerations were fully accounted for in the system design. (2) Improve the technology to ensure its performance and cost potential are substantially better than today’s baseline pulverized coal power plant with post-combustion capture (PCC) or atmospheric oxy-combustion, and show progress toward performance commensurate with projected commercial operation, including 90% or more CO 2 capture. (3) Address critical technology gaps and improving overall system performance for the technology. (4) Perform combustion tests at scale under commensurate pressure to the commercial operating system validate combustor and advance the SPOC combustion modeling tools that will facilitate full-scale design. Combustion Testing: Testing was initially carried out at atmospheric pressure with methane to ensure that all systems were correctly operating. Following this, the testing then proceeded to moderate pressure operation at 4 bara, where different stoichiometric conditions were used across an extended heat input range, showing that a stable flame could be maintained. Testing then proceeded at 10 and 15 bara where it was shown that the ignition system needed to be replaced at these operating conditions. When testing recommenced, a similar stable flame shape was achieved, without any methane support, and the full 100 kWth coal oxy-combustion was demonstrated. Heat flux measurements showed 400 kW/m 2 (0.126 MMBtu/hr-ft 2 ) from the flame, within the 450 kW/m 2 (0.142 MMBtu/hr-ft 2 ) preferred limit defined by DBL for the full-scale design case. Carbon monoxide and carbon-in-ash measurements showed that complete combustion was possible with ultra-low excess oxygen at 1 vol % in the product flue gas. This allowed the full-scale models to be calculated based on this level of excess oxygen, improving the performance of the system as lower feed oxygen is produced in the air separation unit (ASU), saving auxiliary power. Full-Scale Design: The full-scale design is sized to deliver 550 MWe net electrical power output to allow direct comparison with the National Energy Technology Laboratory (NETL) baseline cases using the same Montana Powder River Basin (PRB) fuel. The cases used for direct comparison are: Case S12A (supercritical [SC] coal without CO 2 capture), Case S12B (SC coal with PCC at 90% CO 2 capture, and Case S12F (atmospheric oxy-combustion SC coal with 90% CO 2 capture). The SPOC stages were configured to be identical arrangements, allowing for a more straightforward design, construction, and control strategy. Each stage consists of two PVs, the first being the combustor PV module and the second being the convective PV module. The combustor module is the tallest vessel, with local coal feeding equipment and the burner FGR and oxygen plenums at the top and ash management at the bottom. The combustor module is effectively an open cross section with membrane tubes around the circumference – this unobstructed slender profile ensures that the relatively slower burnout mechanism needed for the low-speed turbulent mixing burner can proceed unimpeded and that molten ash will not attach to any surfaces at an angle to the predominant flue gas flow. The steam turbine used in the SPOC design is essentially the same unit utilized in the atmospheric oxy-combustion case except the degree of heat recovery possible allows the low-pressure (LP) feedwater heater train to be eliminated. This is a result of being able to capture the latent heat of evaporation of the moisture produced in the combustion (normally lost to the stack). The SPOC system outperforms the NETL atmospheric oxy-combustion baseline case by 3.3% points and the PCC case by 7.5% points. This performance increase is mainly a result of the improved heat recovery possible from the product flue gas and from the reduced auxiliary power consumption from the ASU and the CO 2 compression and purification unit over the atmospheric equivalent. The combined improvement in boiler efficiency and reduction in the steam turbine heat rate resulted in a net improvement in the overall plant efficiency by 0.61%, to 35.6% on a HHV basis. This relatively small improvement in plant efficiency between sub-bituminous and bituminous coals shows the value of useful moisture latent heat recovery offered by the SPOC system when using low rank fuels. Flexibility and Turndown: The SPOC system has inherent high turndown capabilities because of a demonstrated high range of combustion stability and the ability to bypass stages, thereby reducing steam generation rates proportionally without altering firing rates in operating stages. ASU units do not generally offer significant turndown opportunities as they are limited by the performance of the compression plant. The baseline SPOC design has a 2-train ASU configuration, needed to be able to meet the 10,500 tonnes per day duty, that can deliver efficient turndown points between 85–100% load with both trains operating, and at 45–50% load with a single train operating. Outside these operating points, the flexibility and efficiency are limited and may be uncompetitive at loads below 45% as the ASU systems are unable to turndown beyond 85% for the base case and 70% for the flexible case. The ASU cold box for the flexible case was designed to operate at loads between 40-100%, below this operating range the purity of the produced oxygen cannot be guaranteed, resulting in additional load for the CPU equipment. The additional power consumption of these cases yields an uneconomic operating condition with poor efficiency when operating at low loads such as 25% and 12%. To address this flexibility constraint, AL evaluated how the ASU configuration could be altered to deliver efficient oxygen supply over the load range. This involved integrating the compressor duties across both ASU trains into a shared duty arrangement with multiple compressors, strategically sized to deliver the duty required across all load ranges between 40–100% by enabling different combinations of the main air compressors and the booster air compressors. The oxygen purity cannot be guaranteed below 40% load for each train – the power consumption at 25% and 12% loads were estimated based on the multi-compressor configuration at maximum turndown as these load cases were not considered in the flexible ASU design. With a different cold box configuration, i.e. number of trains, the entire load range could be delivered within oxygen purity specifications. Although there is a small efficiency reduction at full load, there are significant improvements in overall plant performance during low-load operation. The exact ASU configuration needed will therefore be dependent on the expected operating profile of the unit. Economic Analysis: Cost estimates for the baseline and the flexible cases were developed using NETL baseline case data for common BOP items and an Association for the Advancement of Cost Engineering International Class 5 (conceptual/screening study) assessment of key components unique to the SPOC system. The capital, operating, and maintenance costs were assessed along with the first-year power cost, levelized cost of electricity, and CO 2 captured and avoided cost for the SPOC cases were compared against the relevant NETL baseline cases in January 2019 dollars. Both SPOC cases achieve a lower cost that the alternative NETL baseline cases (with the flexible SPOC case being slightly higher than the baseline SPOC case due to the compounded impact of higher capital costs and lower efficiency at full load). The SPOC cases deliver a lower cost of CO 2 avoided than the NETL baseline cases due to greater efficiency in generating low-carbon power. However, the cost of CO 2 captured is higher because the higher efficiency of the SPOC process generates less CO 2 , hence less needs to be captured, resulting in a high capital cost being shared over a reduced CO 2 quantity. The flexible ASU adds 1.6% overall to the plant cost in comparison to the baseline case, but the efficiency improvements at loads below 50% are significant. Subsequently, depending on the plant load-profile expectation, the flexible ASU would be beneficial if the plant spends a significant portion of its operating life below 50% load. This kind of operating profile is likely to be required for all fossil plants when more renewable electricity generators are installed on the local grid, particularly solar power that can be predicted ahead of time, allowing for appropriate pricing signals to be incorporated into the diurnal cycle. R&D Recommendations: SPOC, while a promising technology, is a relatively recent concept and, as such, operability issues of combustor design and steam-side integration for such systems at a scale relevant to commercial deployment have not been evaluated. WUSTL has conducted extensive small pilot-scale (100 kWth) research to understand and advance pressurized oxy-combustion processes, including investigation of combustion and flame characteristics, radiative heat flux, burner operability, turn down, char burnout, ash characteristics, water-wash column operation, etc. for pressurized oxy-combustion systems. Nonetheless, at this stage in the development of the SPOC process, what is needed is a large-scale pilot plant that can serve to study pressurized oxy-combustion systems and components at a scale commensurate with the maturity of the technology. A scale of 10 MWth, which includes steam-side integration and two stages would yield essential information with respect to heat transfer characteristics both in the radiative and convective sections of the pressure vessels, and the ability to operate the fuel staging process. In addition, while modeling results indicate that combustion and flame characteristics improve with scale, direct studies of the combustor at this scale will ensure that the models can be relied upon for scale up to commercial scale. Furthermore, a detailed analysis must be performed to understand the scaling aspects of key components and systems.

20 FOSSIL-FUELED POWER PLANTS↗

The Staged, Pressurized Oxy-Combustion Technology: Status and Application to Boiler Retrofits to Yield Carbon-Negative Power via Biomass

Recognizing the benefits of pressurization and fuel staging on the efficiency of oxy-combustion, the staged, pressurized oxy-combustion (SPOC) process was introduced in 2012. The combination of fuel staging and pressurized oxy-combustion results in a more compact plant, a higher plant efficiency and reduced costs for pollutant and greenhouse gas removal compared with plants equipped with conventional carbon capture. This approach to power generation enables a modular boiler design and optimizes the plant for flexible operation, which is essential to meet the demands of the modern grid when it contains intermittent power sources. Originally designed to burn coal, the SPOC process is well-suited for biomass because the combustion of biomass leads to a high moisture content in the flue gas and the SPOC process is able to recover the latent heat of this moisture, enhancing system performance over that of traditional biomass combustion at atmospheric pressure. The present work is focused on evaluating the potential for utilizing the SPOC process in retrofit applications wherein the boilers of an existing plant are replaced with the SPOC process, and woody biomass is used as the fuel to yield carbon-negative power. Two applications are considered: power generation and cogeneration (heat and power). Modeling these systems in Aspen Plus demonstrates that the SPOC process surpasses the performance of baseline plants with post-combustion capture (PCC) for both power generation and cogeneration. Specifically, compared to a PCC equipped plant, the SPOC power plant has 33% higher efficiency, and the SPOC cogeneration plant reaches 42% higher net energy. Experimentally, the existing SPOC facility was fired for the first time with 100% biomass and after minor improvements were made to the feeding system, the facility demonstrated excellent performance during startup, steady-state operation and turndown.

Carbon capture and storage↗

Improving Flexibility and Performance of Staged Pressurized Oxy-Combustion

Staged pressurized oxy-combustion (SPOC) is a novel coal combustion power technology being developed by Washington University in St. Louis (WUSTL) that offers the potential to deliver low-carbon power at a reduced cost. Oxy-combustion plants operate by removing most of the nitrogen contained in air prior to combustion, thereby burning fuel in a near-pure oxygen stream instead of air. This combustion produces a flue gas containing primarily carbon dioxide (CO 2 ) and water vapor that allows relatively straightforward CO 2 capture. First-generation, atmospheric oxy-combustion technology relies on a flue gas recycle (FGR) diluent to reduce the peak temperatures achieved and the resulting high thermal radiation levels that would otherwise occur in a fuel/oxygen only flame. In contrast, by staging the combustion in several steps, SPOC reduces the peak temperatures of combustion without resorting to a high degree of FGR to control flame temperatures. The SPOC process operates by utilizing two or more pressurized boiler modules connected in series to produce fuel staging; hence, only a portion of the fuel is combusted in any given combustion module. Subsequently the thermal energy released at each stage can be captured and removed from the gases prior to subsequent stages, when more fuel is introduced. This allows the SPOC process to operate with minimal FGR, avoiding the associated efficiency losses and additional costs. While the staging controls the heat release profile in SPOC, operating in a pressurized condition yields a more compact system, reducing modular boiler size and delivering enhanced heat transfer. Additionally, operating at elevated pressures ensures that the latent heat of moisture available from moisture in the fuel and generated by the combustion of the hydrogen content in the fuel can be captured as useful thermal energy for steam turbine integration. This is possible due to elevated dew point from the high partial pressure of the moisture generated in this process, which allows substantial feedwater heater bypassing to be achieved. The inclusion of this thermal energy, normally lost to the atmosphere in traditional combustion processes or to cooling systems in atmospheric oxy-combustion, allows the resultant net efficiency of the SPOC system to be up to 6 percentage points greater than first-generation systems. To begin the process of developing this technology for full-scale application, the Electric Power Research Institute, Inc. teamed up with WUSTL, American Air Liquide, Doosan Babcock, and the U.S. Department of Energy to investigate a practical and workable boiler design concept that would minimize process risks where possible. The SPOC system offers unique process flexibility opportunities due to the staged nature of the combustion, making it a prime candidate for future primary energy delivery where the ability to operate at reduced load in an efficient manner and ramp rapidly will be valuable for balancing intermittent renewable electricity generation. The efficiency of traditional coal-fired power plants is lower at reduced loads below the steam temperature control range due to the challenges in balancing the heat pickup between radiative and convective superheater and reheater surface. Introducing additional heating surface for optimal extended controlled low load operation will likely lead to excessive attemperation at high loads, ultimately leading to a poorer overall cycle efficiency. The SPOC process can facilitate the adjustment of fuel firing rates between stages, targeting heat pickup to where it is most needed and potentially can shut down stages for low-load operation, facilitating an increased steam temperature control range on turndown. The boiler design concept assessment is being carried out to identify the maximum permissible compactness of the SPOC boiler heating surfaces. The assessment will determine the minimum overall height that will deliver appropriate tube operating metal temperatures at full load and achieve rated reheat steam temperatures at low operating loads, balanced against the needs of efficient coal combustion, and the potential resultant slagging and ash environments. The design parameters are being validated by combustion testing in the 100-kWth pressurized combustion test rig at WUSTL. Parameters being investigated include flame stability, fuel burnout, ash composition, radiative heat flux, and temperature profiles. These are being carried out for a range of inlet gas conditions and compositions and at multiple load conditions to investigate combustion stability at reduced load. The results of this testing inform the modeling of the large-scale system, that was sized at 550 MWe to allow direct comparison with the National Energy Technology Laboratory baseline cases for atmospheric oxy-combustion, air firing, and air firing with post-combustion capture.

20 FOSSIL-FUELED POWER PLANTS↗

Performance and flexibility improvements of Staged Pressurized Oxy-Combustion

Staged Pressurized Oxy-Combustion (SPOC) is a low-carbon coal combustion power technology being developed by Washington University in St. Louis (WUSTL). Oxy-combustion plants enable straightforward capture of carbon dioxide (CO 2 ) by removing most of the nitrogen in the combustion air prior to use, thereby burning fuel in near-pure oxygen instead of air, producing a flue gas containing primarily CO 2 and water. CO 2 capture at amounts > 90% is possible, often using cryogenic air separation. Oxy-combustion typically relies on flue gas recycle (FGR) to reduce the peak temperature and radiation that would otherwise occur in a fuel/oxygen only flame. SPOC reduces the peak temperatures of combustion by utilizing two or more pressurized boiler modules connected in series to produce fuel staging; hence, only a portion of the fuel is combusted in any given furnace module. This means that the thermal energy released at each stage can be captured and removed from the gases prior to subsequent stages, when more fuel is introduced. This allows the SPOC process to operate with minimal FGR, avoiding the associated efficiency losses and additional costs. Also, the process operates at an elevated gas-side pressure, reducing boiler size, enhancing heat transfer to achieve a compact boiler configuration as compared to an atmospheric-pressure boiler design, and allowing for recovery of the latent heat of the water from the flue gas at a temperature useful to the steam cycle. The resultant net efficiency of the system is over 3 percentage points greater than traditional atmospheric-pressure oxy-combustion, and 7 percentage points greater than the post combustion variant, representing a step-change improvement over first-generation capture technologies. To further develop the concept, WUSTL and the Electric Power Research Institute, Inc., organized a project with American Air Liquide, Inc., Doosan Babcock Limited, and the U.S. Department of Energy to investigate a practicable and workable boiler design. The team has identified the potential for enhanced process flexibility for controlling power generation over a wider load range than is normally available to conventional coal-fired power plants due to the staged nature of the heat release. With increasing intermittent renewable generator contribution, on-demand generators need to be highly flexible to participate in the future energy market, requiring extensive operation at reduced load. Conventional coal-fired steam generators typically face challenges in maintaining temperature control of the reheat steam and main steam at reduced loads. This results in inefficient operation, both in terms of the boiler efficiency and steam turbine heat rate. The results of this project show the SPOC process is capable of exceptional turndown, both on a stage basis and with the ability to bypass entire stages. Oxygen-supply flexibility was also investigated, as this is also a key consideration for the overall flexibility of the SPOC process given the operating constraints of conventional air separation units. A boiler design concept assessment was conducted and was focused on delivering compact and constructible design. The assessment checked appropriate tube operating metal temperatures at full load and at lower operating loads, balanced against the needs of efficient coal combustion, and the resultant slagging and ash environments. Combustion testing in the 100-kWth pressurized combustion test rig at WUSTL was carried out to validate the combustion, heat flux profiles and burnout at multiple loads. Combustion parameters investigated were flame stability, fuel burnout, ash composition, radiative heat flux, and temperature profiles. The results of these tests formed the basis of a full-scale boiler design that will encompass improvements in both efficiency and flexibility over conventional oxy-combustion processes. The air separation unit flexibility was investigated, and associated cost implications were addressed. Detailed economic assessment results for a 550 MWe net power block are also provided, allowing for a comparison against the baseline NETL oxy-combustion and post combustion capture cases.

20 FOSSIL-FUELED POWER PLANTS↗

Staged, High-Pressure Oxy-Combustion Technology: Development and Scale-Up

The immediate need for a high efficiency, low cost carbon capture process has prompted the recent development of pressurized oxy-combustion. With a greater combustion pressure the dew point of the flue gas is increased, allowing for effective integration of the latent heat of flue gas moisture into the Rankine cycle. This increases the net plant efficiency and reduces costs. A novel, transformational process, named Staged, Pressurized Oxy-Combustion (SPOC), achieves additional step changes in efficiency and cost reduction by significantly reducing the recycle of flue gas. The research and development activities conducted under Phases I and II of this project (FE0009702) include: SPOC power plant cost and performance modeling, CFD-assisted design of pressurized SPOC boilers, theoretical analysis of radiant heat transfer and ash deposition, boiler materials corrosion testing, construction of a 100 kWth POC test facility, and experimental testing. The results of this project have advanced the technology readiness level (TRL) of the SPOC technology from 1 to 5.

01 COAL, LIGNITE, AND PEAT↗

Catalytic Removal of Oxygen and Pollutants in Exhaust Gases from Pressurized Oxy-Combustors

The primary goal of this project was to develop and validate advanced catalytic materials and systems for purifying the flue gas generated from pressurized oxy-combustors in an effort to achieve the purity specifications of carbon dioxide (CO 2 ) streams required by the U.S. Department of Energy (USDOE) for application in enhanced oil recovery. The technology has shown great potential for improving energy efficiency, simplifying process complexity, and lowering costs compared with current state-of-the-art oxy-combustion flue gas purification technologies. Laboratory studies were conducted for the development, characterization, and screening of metal catalysts for residual oxygen (O 2 ) reduction with methane (CH 4 ) and multifunctional carbon catalysts for combined nitrogen oxides (NO x ), sulfur oxides (SO x ), and mercury (Hg) removal. A bench-scale reverse-flow fixed-bed (RFFB) reactor and a trickle-bed direct-contact cooler (DCC) reactor capable of treating 15 standard liters per min of pressurized oxy-combustion flue gas were fabricated and tested with both a simulated flue gas in the laboratory and a slipstream of actual flue gas at a 100 kW th Staged, Pressurized Oxy-Combustion (SPOC) pilot facility. Process simulation and techno-economic studies were performed to evaluate the energy efficiency and cost of the developed catalytic flue gas purification process integrated into a conceptual 550-MWe SPOC power plant. The goal and objectives of the project have been successfully accomplished. A cobalt-manganese (CoMn) oxide catalyst was developed and demonstrated in the bench-scale RFFB reactor in either a reverse-flow or one-direction flow mode of operation that met the success criterion of performance for residual O 2 reduction. A carbon catalyst was developed and demonstrated in the bench-scale DCC reactor that met the success criterion of performance for combined NO x /SO x /Hg removal. Slipstream testing of the integrated DCC-RFFB system at the SPOC pilot facility demonstrated stable operation and verified the superior performance obtained in the laboratory. The techno-economic analysis showed that a 550-MWe SPOC plant integrated with the catalytic flue gas purification process would result in costs of electricity of $\$$96.94/MWh and $\$$80.27/MWh in two assessed cases compared with $\$$91.07/MWh reported for the USDOE’s Current Technology Case, which generated only a partially pure CO 2 stream. On the basis of the results and findings from this project, scale-up studies of materials production and system demonstration and optimization studies of reactors and processes are recommended at the next stage of technology development.

20 FOSSIL-FUELED POWER PLANTS↗

A Development of Critical Components for the Modular Staged Pressurized Oxy-Combustion Power Plant

DOE's Coal FIRST (Flexible, Innovative, Resilient, Small, Transformative) Initiative was implemented to encourage the development of the coal plant of the future, which will be capable of flexible operation to meet the needs of the grid; using innovative and cutting-edge components that improve efficiency and reduce emissions; providing resilient power to Americans; being small compared to today's conventional utility-scale coal power plants; and transforming how coal power plant technologies are designed and manufactured. The modular Staged, Pressurized Oxy-Combustion (SPOC) process envisioned by and under development at Washington University in St. Louis (WUSTL) has the potential to achieve these goals. The process offers: 1) a modular plant design for improved operational flexibility; 2) fuel-staging combined with pressurized oxy-combustion, which leads to smaller plant size, higher plant efficiency, and lower cost for pollutant and greenhouse gases removal compared with traditional carbon-capture equipped coal power plants; and 3) small modular boilers and pollutant removal units that can be fabricated in shop and assembled on site, further reducing plant capital costs. Under DOE's support (DE-FE0031925), WUSTL is advancing the development of the critical components for the SPOC power plant, including the integrated combustion system and the direct contact cooler (DCC) from TRL 4 to TRL-5, which would allow them to be subsequently incorporated into a pilot plant. These units are the only two components that are not commercially available for a SPOC plant, and hence, their development is a key step toward the commercialization of SPOC. This work presents the objectives, task descriptions, and current progress of the project. So far, the fabrication of a new combustor design and the convective heat transfer boiler has been completed, and the integration of the combustor, boiler, and DCC is underway. Recent results obtained with the newly designed combustor show a stable coal/methane flame while dry-feeding PRB coal under oxy-combustion conditions.

Magalhaes, Duarte↗

Integrated Flue Gas Purification and Latent Heat Recovery for Pressurized Oxy-Combustion (Final Scientific/Technical Report)

Pressurized oxy-combustion has been identified by DOE as a transformational technology for coal power with carbon capture due to the advantages that are realized when the combustion process is pressurized. The staged pressurized oxy-combustion (SPOC) process is particularly attractive as the efficiency of the process is almost 6 percentage points greater than that of first generation oxy-combustion. A critical component of the SPOC process, and potentially other pressurized combustion processes, is the Direct Contact Cooler (DCC) where the latent heat of the flue gas moisture is recovery to improve plant efficiency while simultaneously removing SO x and NO x from the flue gas, so that the FGD and de-NO x processes can be eliminated, and the cost of electricity minimized. The objective of this R&D effort was to advance the TRL of the DCC technology, which included performance testing at a 100 kW scale to validate the process and obtain key engineering data for scale-up. A collateral objective was to study the gas- and liquid-phase kinetics, and the development of a systematic chemical mechanism validated by experimental data. Experiments in a bench-scale stirred reactor provided an updated understanding of the liquid chemistry and the effects of temperature and pH. This information was used to develop a reduced reaction mechanism, which was subsequently incorporated in an ASPENbased process model, to allow for evaluation of the DCC at full scale. A small-pilot DCC column was designed, constructed and tested using simulated flue gas at the pressurized oxy-combustion test facility at Washington University in St. Louis. In the majority of tests, the SO 2 capture approached 100%, making the NO x capture the primary metric of capture efficiency. An NO x capture efficiency of 90% was achieved when the gas residence time was 95 seconds, demonstrating that high capture rates can be attained with reasonable reactor size. At higher temperatures (up to 200°C inlet gas temperature) the total NO x scrubbing efficiency was reduced by approximately 10% (compared to room temp.) and this was attributed to a reduced NO oxidation rate. A significant amount of SO 2 was present in the gas outlet (10%) only when the temperature was high and the N:S ratio was low (N/S < 1), which highlights the necessity of controlling the NOx concentration in the flue gas for complete sulfur scrubbing. After incorporated our optimized chemical mechanism into an ASPEN process model, various full-scale configurations of the DCC were evaluate, and the results indicate that the proposed DCC can accomplish its intended goals at full scale and at a modest size. Thus, the results of this project indicate that the DCC is a promising technology for recovery of the latent heat of the moisture in the flue gas while simultaneously scrubbing the nitrogen and sulfur oxides, thus enabling pressurized oxy-combustion, in general, and the SPOC process, in particular.

01 COAL, LIGNITE, AND PEAT↗

Experimental study on particle formation in a pressurized oxy-fuel combustor using a novel in-situ optical instrument

Particle formation in pressurized oxy-fuel combustion can be fundamentally different from oxy-fuel combustion at atmospheric pressure. Under high pressures, the rate of char gasification with CO2 and H2O increases significantly and dominates the char reactions particularly at high temperatures. Also, the extent of fragmentation varies. This could result in a very different particle size distribution from that of air-fired combustion. To accurately obtain the particle size distribution in a pressurized oxy-fuel combustor without sampling bias, the particle measurement should be made at the system pressure. Very few published studies have accomplished this, and never under the conditions reported herein. In this work, we fire PRB coal in a 100 kWth staged pressurized oxy-fuel combustor (SPOC) under two pressures, 15 and 2 bara. A sampling probe (oil-cooled) is installed at the combustor outlet and the aerosol flow are sampled isokinetically. We utilize a state-of-the-art optical analyzer (Malvern Insitec) with a novel high-pressure and high-temperature flow cell to measure the particle size distribution and concentration in-situ in a sampled flow, which contains moist/corrosive flue gas under the process pressure and a controlled temperature that is kept above the dew point. The results show that the pressure can significantly influence the particle size distribution and concentration from the oxy-fuel combustor.

Cheng, Mao↗

In-situ measurement of moist flue gas under high pressure using a nafion dryer and FTIR

The formation of the main flue gas species (NOx, SOx, CO2, and CO) in pressurized oxy-fuel combustion can be fundamentally different from oxy-fuel combustion at atmospheric pressure. To accurately obtain the concentration of these gas species in a pressurized oxy-fuel combustor, a gas measurement which maintains the sampling pressure is needed. Very few published studies have accomplished this, and never under the conditions reported herein. In this work, we fire PRB coal in a 100 kWth staged pressurized oxy-fuel combustor (SPOC) under a pressure 15 bara. We utilize a state-of-the-art FTIR (Thermo Scientific Nicolet iS20) with a novel high-pressure gas cell that is under process pressure to measure the in-situ flue-gas concentration in a sampled flow. However, water vapor can significantly interfere with the FTIR measurement, particularly under pressure. To address this problem, we have developed a high-pressure nafion dryer to selectively remove the water vapor from the flue gas while retaining the flue gas species. This approach can significantly increase the signal-noise ratio for the FTIR. By integrating the nafion dryer and the high-pressure gas cell, we were able to successfully measure flue gas species at system pressure with the FTIR.

Cheng, Mao↗