Search NASASearch

SEARCH · Search NASA

Results for “SPRING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Depositional facies and aqueous-solid geochemistry of travertine-depositing hot springs (Angel Terrace, Mammoth Hot Springs, Yellowstone National Park, U.S.A.)

Petrographic and geochemical analyses of travertine-depositing hot springs at Angel Terrace, Mammoth Hot Springs, Yellowstone National Park, have been used to define five depositional facies along the spring drainage system. Spring waters are expelled in the vent facies at 71 to 73 degrees C and precipitate mounded travertine composed of aragonite needle botryoids. The apron and channel facies (43-72 degrees C) is floored by hollow tubes composed of aragonite needle botryoids that encrust sulfide-oxidizing Aquificales bacteria. The travertine of the pond facies (30-62 degrees C) varies in composition from aragonite needle shrubs formed at higher temperatures to ridged networks of calcite and aragonite at lower temperatures. Calcite "ice sheets", calcified bubbles, and aggregates of aragonite needles ("fuzzy dumbbells") precipitate at the air-water interface and settle to pond floors. The proximal-slope facies (28-54 degrees C), which forms the margins of terracette pools, is composed of arcuate aragonite needle shrubs that create small microterracettes on the steep slope face. Finally, the distal-slope facies (28-30 degrees C) is composed of calcite spherules and calcite "feather" crystals. Despite the presence of abundant microbial mat communities and their observed role in providing substrates for mineralization, the compositions of spring-water and travertine predominantly reflect abiotic physical and chemical processes. Vigorous CO2 degassing causes a +2 unit increase in spring water pH, as well as Rayleigh-type covariations between the concentration of dissolved inorganic carbon and corresponding delta 13C. Travertine delta 13C and delta 18O are nearly equivalent to aragonite and calcite equilibrium values calculated from spring water in the higher-temperature (approximately 50-73 degrees C) depositional facies. Conversely, travertine precipitating in the lower-temperature (< approximately 50 degrees C) depositional facies exhibits delta 13C and delta 18O values that are as much as 4% less than predicted equilibrium values. This isotopic shift may record microbial respiration as well as downstream transport of travertine crystals. Despite the production of H2S and the abundance of sulfide oxidizing microbes, preliminary delta 34S data do not uniquely define the microbial metabolic pathways present in the spring system. This suggests that the high extent of CO2 degassing and large open-system solute reservoir in these thermal systems overwhelm biological controls on travertine crystal chemistry.

Non-NASA Center

Spring operated accelerator and constant force spring mechanism therefor

A spring assembly consisting of an elongate piece of flat spring material formed into a spiral configuration and a free running spool in circumscribing relation to which this spring is disposed was developed. The spring has a distal end that is externally accessible so that when the distal end is drawn along a path, the spring unwinds against a restoring force present in the portion of the spring that resides in a transition region between a relatively straight condition on the path and a fully wound condition on the spool. When the distal end is released, the distal end is accelerated toward the spool by the force existing at the transition region which force is proportional to the cross-sectional area of the spring.

Shillinger, G. L., Jr.

Segmented tubular cushion springs and spring assembly

A spring which includes a tube with an elliptical cross section, with the greater axial dimension extending laterally and the lesser axial dimension extending vertically is disclosed. A plurality of cuts in the form of slots passing through most of a wall of the tube extend perpendiculary to a longitudinal axis extending along the tube. An uncut portion of the tube wall extends along the tube for bonding or fastening the tube to a suitable base, such as a bottom of a seat cushion.

Haslim, L. A.

Segmented tubular cushion springs and spring assembly

A spring (10) includes a tube (12) having an elliptical cross section, with the greater axial dimension (22) extending laterally and the lesser axial dimension (24) extending vertically. A plurality of cuts (20) in the form of slots passing through most of a wall of the tube (12) extend perpendicularly to a longitudinal axis (16) extending along the tube (12). An uncut portion (26) of the tube wall extends along the tube (12) for bonding or fastening the tube to a suitable base, such as a bottom (28) of a seat cushion (30).

Haslim, Leonard A.

MOD-Amp System Design Spring: Spring 2026 – Georgetown University, SYSM–5620

High-energy lasers (HELs) play an important role in both national defense and scientific research. In defense applications, HELs are used for target detection, tracking, and engagement. In research environments, they support studies of extreme physical conditions relevant to fusion energy and plasma science. These systems depend on the amplification of light through stimulated emission of radiation, allowing optical energy to be increased to the levels required for operation. This amplification occurs when light passes through an energized gain medium that receives energy from an external optical or electrical source. To achieve the desired output, laser systems often use multiple amplification stages, including high-gain preamplifiers and lower-gain power or booster amplifiers. At Lawrence Livermore National Laboratory (LLNL) and other national laboratories, many large-aperture laser amplifier systems are aging and rely on system-specific hardware, obsolete technologies, and incomplete documentation. These legacy systems create challenges for maintenance, supportability, and long-term operation. Their lack of standardization also increases the difficulty of sustaining reliable performance over time. As this infrastructure continues to age, the likelihood of unplanned downtime grows, which can negatively affect both national security missions and scientific research programs that depend on dependable HEL capabilities. The purpose of this document is to demonstrate the application of systems engineering fundamentals and design thinking through the development of a laser amplifier case study. The proposed system concept is intended as an academic exercise and not as a finalized engineering design. As a result, the development presented in this document is incomplete and may contain technical assumptions or errors that would require further investigation before any real-world implementation.

42 ENGINEERING

Manufacturing methods for machining spring ends parallel at loaded length

A first end surface of a coiled compression spring at its relaxed length is machined to a plane transverse to the spring axis. The spring is then placed in a press structure having first and second opposed planar support surfaces, with the machined spring end surface bearing against the first support surface, the unmachined spring end surface bearing against a planar first surface of a lateral force compensation member, and an opposite, generally spherically curved surface of the compensation member bearing against the second press structure support surface. The spring is then compressed generally to its loaded length, and a circumferentially spaced series of marks, lying in a plane parallel to the second press structure support surface, are formed on the spring coil on which the second spring end surface lies. The spring is then removed from the press structure, and the second spring end surface is machined to the mark plane. When the spring is subsequently compressed to its loaded length the precisely parallel relationship between the machined spring end surfaces substantially eliminates undesirable lateral deflection of the spring.

Hinke, Patrick Thomas

Manufacturing methods for machining spring ends parallel at loaded length

A first end surface of a coiled compression spring at its relaxed length is machined to a plane transverse to the spring axis. The spring is then placed in a press structure having first and second opposed planar support surfaces, with the machined spring end surface bearing against the first support surface, the unmachined spring end surface bearing against a planar first surface of a lateral force compensation member, and an opposite, generally spherically curved surface of the compensation member bearing against the second press structure support surface. The spring is then compressed generally to its loaded length, and a circumferentially spaced series of marks, lying in a plane parallel to the second press structure support surface, are formed on the spring coil on which the second spring end surface lies. The spring is then removed from the press structure, and the second spring end surface is machined to the mark plane. When the spring is subsequently compressed to its loaded length the precisely parallel relationship between the machined spring end surfaces substantially eliminates undesirable lateral deflection of the spring.

Hinke, Patrick Thomas

Variable stiffness torsion springs

In a torsion spring the spring action is a result of the relationships between the torque applied in twisting the spring, the angle through which the torsion spring twists, and the modulus of elasticity of the spring material in shear. Torsion springs employed industrially have been strips, rods, or bars, generally termed shafts, capabable of being flexed by twisting their axes. They rely on the variations in shearing forces to furnish an internal restoring torque. In the torsion springs herein the restoring torque is external and therefore independent of the shearing modulus of elasticity of the torsion spring shaft. Also provided herein is a variable stiffness torsion spring. This torsion spring can be so adjusted as to have a given spring constant. Such variable stiffness torsion springs are extremely useful in gimballed payloads such as sensors, telescopes, and electronic devices on such platforms as a space shuttle or a space station.

Alhorn, Dean C.

Variable stiffness torsion springs

In a torsion spring the spring action is a result of the relationships between the torque applied in twisting the spring, the angle through which the torsion spring twists, and the modulus of elasticity of the spring material in shear. Torsion springs employed industrially have been strips, rods, or bars, generally termed shafts, capabable of being flexed by twisting their axes. They rely on the variations in shearing forces to furnish an internal restoring torque. In the torsion springs herein the restoring torque is external and therefore independent of the shearing modulus of elasticity of the torsion spring shaft. Also provided herein is a variable stiffness torsion spring. This torsion spring can be so adjusted as to have a given spring constant. Such variable stiffness torsion springs are extremely useful in gimballed payloads such as sensors, telescopes, and electronic devices on such platforms as a space shuttle or a space station.

Alhorn, Dean C.

Single-Crystal Springs For Accelerometers

Thermal noise reduced, enabling use of smaller proof masses. Spring-and-mass accelerometers in which springs made of single-crystal material being developed. In spring-and-mass accelerometer, proof mass attached to one end of spring, and acceleration of object at other end of spring measured in terms of deflection of spring, provided frequency spectrum of acceleration lies well below resonant frequency of spring-and-proof-mass system. Use of single-crystal spring materials instead of such polycrystalline spring materials as ordinary metals makes possible to construct highly sensitive accelerometers (including seismometers) with small proof masses.

Vanzandt, Thomas R.

Fossilization Processes in Thermal Springs

To create a comparative framework for the study of ancient examples, we have been carrying out parallel studies of the microbial biosedimentology, taphonomy and geochemistry of modem and sub-Recent thermal spring deposits. One goal of the research is the development of integrated litho- and taphofacies models for siliceous and travertline sinters. Thermal springs are regarded as important environments for the origin and early evolution of life on Earth, and we seek to utilize information from the fossil record to reconstruct the evolution of high temperature ecosystems. Microbial contributions to the fabric of thermal spring sinters occur when population growth rates keep pace with, or exceed rates of inorganic precipitation, allowing for the development of continuous biofilms or mats. In siliceous thermal springs, microorganisms are typically entombed while viable. Modes of preservation reflect the balance between rates of organic matter degradation, silica precipitation and secondary infilling. Subaerial sinters are initially quite porous and permeable and at temperatures higher than about 20 C, organic materials are usually degraded prior to secondary infilling of sinter frameworks. Thus, organically-preserved microfossils are rare and fossil information consists of characteristic biofabrics formed by the encrustation and underplating of microbial mat surfaces. This probably accounts for the typically low total organic carbon values observed in thermal spring deposits. In mid-temperature, (approx. 35 - 59 C) ponds and outflows, the surface morphology of tufted Phormidium mats is preserved through mat underplating by thin siliceous: crusts. Microbial taxes lead to clumping of ceils and/or preferred filament orientations that together define higher order composite fabrics in thermal spring stromatolites (e.g. network, coniform, and palisade). At lower temperatures (less than 35 C), Calothrix mats cover shallow terracette pools forming flat carpets or pustular surfaces that produce palisade and "shrub" fabrics, respectively. At finer scales, composite fabrics are seen to consist distinctive associations of microstructures formed by the encrustation of individual cells and filaments. Composite fabrics survive the diagenetic transitions from primary opaline silica to quartz and are known from subaerial thermal spring deposits as old as Lower Carboniferous. However, fossil microorganisms tend to be rare in older deposits, and are usually preserved only where cells or sheaths have been stained by iron oxides. In subaqueous mineralizing springs at lower temperatures, early infilling leads to a more rapid and complete reduction in porosity and permeability. This process, along with the slower rates of microbial degradation at lower temperatures, creates a more favorable situation for organic matter preservation. Application of this taphonomic model to the Rhynie Chert, previously interpreted as subaerial, suggest it was probably deposited in a subaqueous spring setting at lower temperatures.

Farmer, Jack D.

Design of Ceramic Springs for Use in Semiconductor Crystal Growth in Microgravity

Segregation studies can be done in microgravity to reduce buoyancy driven convection and investigate diffusion-controlled growth during the growth of semiconductor crystals. During these experiments, it is necessary to prevent free surface formation in order to avoid surface tension driven convection (Marangoni convection). Semiconductor materials such as gallium arsenide and germanium shrink upon melting, so a spring is necessary to reduce the volume of the growth chamber and prevent the formation of a free surface when the sample melts. A spring used in this application must be able to withstand both the high temperature and the processing atmosphere. During the growth of gallium arsenide crystals during the GTE Labs/USAF/NASA GaAs GAS Program and during the CWRU GaAs programs aboard the First and Second United States microgravity Laboratories, springs made of pyrolytic boron nitride (PBN) leaves were used. The mechanical properties of these PBN springs have been investigated and springs having spring constants ranging from 0.25 N/mm to 25 N/mm were measured. With this improved understanding comes the ability to design springs for more general applications, and guidelines are given for optimizing the design of PBN springs for crystal growth applications.

Kaforey, M. F.

Thermal Springs and the Search for Past Life on Mars

Ancient thermal spring sites have several features which make them significant targets in a search for past life. Chemical (including redox) reactions in hydrothermal systems possibly played a role in the origin of life on Earth and elsewhere. Spring waters frequently contain reduced species (sulfur compounds, Fe(sup +2), etc.) which can provide chemical energy for organic synthesis. Relatively cool hydrothermal systems can sustain abundant microbial life (on Earth, at temperatures greater than 110 C). A spring site on Mars perhaps might even have maintained liquid water for periods sufficiently long to sustain surface-dwelling biota had they existed. On Earth, a variety of microbial mat communities can be sampled along the wide range of temperatures surrounding the spring, thus offering an opportunity to sample a broad biological diversity. Thermal spring waters frequently deposit minerals (carbonates, silica, etc.) which can entomb and preserve both fluid inclusions and microbial communities. These deposits can be highly fossiliferous and preserve biological inclusions for geologically long periods of time. Such deposits can cover several square km on Earth, and their distinctive mineralogy (e.g., silica- and/or carbonate-rich) can contrast sharply with that of the surrounding region. As with Martian volcanoes, Martian thermal spring complexes and their deposits might typically be much larger than their counterparts on Earth. Thus Martian spring deposits are perhaps readily detectable and even accessible. Elysium Planitia is an example of a promising region where hydrothermal activity very likely remobilized ground ice and sustained springs.

DesMarais, D. J.

Helical spring holder assembly

A helically-threaded spring holder on which a helically wound spring is mounted has a groove formed in one side of the thread at the end where the spring engages the spring holder. The groove relieves the portion of the side in which it is formed from restricting the spring against axial movement during deflection of the spring. The circumferential length of this groove is chosen to establish the number of spring coils which can be deflected without contacting the side of the thread. The end of the thread is also made rigid to prevent flexing thereof during maximal elongation of the spring.

Newman, Wyatt S.

Distribution of cultivated and uncultivated cyanobacteria and Chloroflexus-like bacteria in hot spring microbial mats

Oligodeoxynucleotide hybridization probes were developed to complement specific regions of the small subunit (SSU) rRNA sequences of cultivated and uncultivated cyanobacteria and Chloroflexus-like bacteria, which inhabit hot spring microbial mats. The probes were used to investigate the natural distribution of SSU rRNAs from these species in mats of Yellowstone hot springs of different temperatures and pHs as well as changes in SSU rRNA distribution resulting from 1-week in situ shifts in temperature, pH, and light intensity. Synechococcus lividus Y-7c-s SSU rRNA was detected only in the mat of a slightly acid spring, from which it may have been initially isolated, or when samples from a more alkaline spring were incubated in the more acid spring. Chloroflexus aurantiacus Y-400-fl SSU rRNA was detected only in a high-temperature mat sample from the alkaline Octopus Spring or when lower-temperature samples from this mat were incubated at the high-temperature site. SSU rRNAs of uncultivated species were more widely distributed. Temperature distributions and responses to in situ temperature shifts suggested that some of the uncultivated cyanobacteria might be adapted to high-, moderate-, and low-temperature ranges whereas an uncultivated Chloroflexus-like bacterium appears to have broad temperature tolerance. SSU rRNAs of all uncultivated species inhabiting a 48 to 51 degrees C Octopus Spring mat site were most abundant in the upper 1 mm and were not detected below a 2.5-to 3.5-mm depth, a finding consistent with their possible phototrophic nature. However, the effects of light intensity reduction on these SSU rRNAs were variable, indicating the difficulty of demonstrating a phototrophic phenotype in light reduction experiments.

Non-NASA Center

Linear magnetic spring and spring/motor combination

A magnetic spring, or a spring and motor combination, providing a linear spring force characteristic in each direction from a neutral position, in which the spring action may occur for any desired coordinate of a typical orthogonal coordinate system. A set of magnets are disposed, preferably symmetrically about a coordinate axis, poled orthogonally to the desired force direction. A second set of magnets, respectively poled opposite the first set, are arranged on the sprung article. The magnets of one of the sets are spaced a greater distance apart than those of the other, such that an end magnet from each set forms a pair having preferably planar faces parallel to the direction of spring force, the faces being offset so that in a neutral position the outer edge of the closer spaced magnet set is aligned with the inner edge of the greater spaced magnet set. For use as a motor, a coil can be arranged with conductors orthogonal to both the magnet pole directions and the direction of desired spring force, located across from the magnets of one set and fixed with respect to the magnets of the other set. In a cylindrical coordinate system having axial spring force, the magnets are radially poled and motor coils are concentric with the cylinder axis.

Patt, Paul J.