FY2020 Savannah River Site Composite Analysis Annual Summary Review

This document provides the Department of Energy (DOE) Order 435.1 and its manual, Radioactive Waste Management (DOE 2021a, 2021b) required Annual Review for the Savannah River Site (SRS) Composite Analysis (CA). Progress made to-date toward addressing the secondary issue from the LFRG review of the 2010 SRS CA has focused primarily upon inventory estimate improvements. Inventory impacts dose in a linear fashion and reduces the uncertainty with the CA conclusions. Maintenance items are addressed, as funding allows, based on the relative risk associated with meeting the performance objectives. Currently, there is minimal risk in exceeding the DOE 100 mrem/yr CA primary dose limit or the DOE 30 mrem/yr dose constraint (administrative limit). Proposed activities, discoveries, new information and changes potentially affecting the 2010 SRS CA are documented in this and earlier Annual Summary reports, and a consolidated list of changes since the 2010 CA is documented in this report. The impact to the CA of changes arising from updated performance assessment (PA) baselines [i.e., Saltstone Disposal Facility (SDF), E-Area Low-Level Waste Facility (ELLWF), and F & H Tank Farm (FTF & HTF) closures] is expected to be minor for the following reasons: The primary contributors to the SRS CA dose impact at the Upper Three Runs (UTR) point of assessment (POA) are the H-Canyon and Mixed Waste Management Facility (MWMF), contributing 68% and 9%, respectively, to the dose impact at that POA. The combined contribution to the UTR dose impact from all PA’s (SDF, ELLWF, FTF and HTF) is ~2% of this total. The 2010 SRS CA model validation performed indicates that the CA projected dose, while generally conservative, provides a reasonable representation of the maximum annual doses. Doses evaluated are well below the SRS established 15 mrem/yr administrative limit (Crapse et al. 2011). Based on the assessment presented within this annual review and collective engineering judgement, the conclusions of the 2010 SRS CA remain valid and there is reasonable assurance that SRS will meet the performance objectives delineated in DOE Manual 435.1-1. The 2010 SRS CA should be updated to incorporate PA changes, proposed changes to inventories and sources and model improvements accumulated since the 2010 CA. The timing will be dependent on the completion of the ongoing E-Area PA revision.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SRS Composite Analysis Monitoring Plan (FY2019 Model Validation)

Using a projected end-state date of 2065 (SRNS 2015b), the Savannah River Site (SRS) Composite Analysis (CA) modeling for each facility and waste site began on the inventory year assigned to it so that source depletion and radionuclide transport out of the system could be appropriately captured. Some SRS waste sites that have already achieved their end states (i.e. end-state inventories and end-state configuration) are currently contributing to the potential off-site public dose through source release, groundwater transport, discharge to on-site surface streams, and stream transport to the CA point of assessments (POAs). The inventory year assigned to these waste sites is 2002 or before. This means that SRS CA results from 2002 and beyond are a reasonable representation for these waste sites that have already achieved their end states and are currently contributing to the potential off-site public dose. The SRS Annual Environmental Report (AER) monitoring can differentiate and separate liquid pathway data allowing the data representing only waste sites at their end state to be produced. Because the SRS CA has projected reasonable end-state impacts from 2002 and beyond, and the AER monitoring can differentiate and separate operating and end-state contributions to annual liquid pathway release, an opportunity exists to use the AER monitoring data to validate the SRS CA model. The CA model validation program uses a graded and systematic approach for taking corrective action, starting with an SRS established administrative dose limit of 15 mrem/yr, below which no action is required. Based on the location of the 2010 SRS CA POAs, the only potential exposure pathway for the public is through surface water. The completion of the FY2019 CA model validation indicates that the SRS CA projected dose, while generally conservative, provides a reasonable representation of the maximum annual doses. These doses are well below the administrative limit; therefore, no additional action is required.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY2021 Savannah River Site Composite Analysis Annual Summary Review

This document provides the Department of Energy (DOE) Order 435.1 and its manual, Radioactive Waste Management (DOE 2021a, 2021b) required Annual Review for the Savannah River Site (SRS) Composite Analysis (CA). Progress made to-date toward addressing the secondary issue from the LFRG review of the 2010 SRS CA has focused primarily upon inventory estimate improvements. Inventory impacts dose in a linear fashion and reduces the uncertainty with the CA conclusions. Maintenance items are addressed, as funding allows, based on the relative risk associated with meeting the performance objectives. Currently, there is minimal risk in exceeding the DOE 100 mrem/yr CA primary dose limit or the DOE 30 mrem/yr dose constraint (administrative limit).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model Validation for the FY2021 SRS Composite Analysis Monitoring Plan

Using a projected end-state date of 2065 (SRNS 2015b), the Savannah River Site (SRS) Composite Analysis (CA) modeling for each facility and waste site began on the inventory year assigned to it so that source depletion and radionuclide transport out of the system could be appropriately captured. Some SRS waste sites that have already achieved their end states (i.e., end-state inventories and end-state configuration) are currently contributing to the potential off-site public dose through source release, groundwater transport, discharge to on-site surface streams, and stream transport to the CA point of assessments (POAs). The inventory year assigned to these waste sites is 2002 or before. This means that SRS CA results from 2002 and beyond are a reasonable representation for these waste sites that have already achieved their end states and are currently contributing to the potential off-site public dose. The SRS Annual Environmental Report (AER) monitoring can differentiate and separate liquid pathway data allowing the data representing only waste sites at their end state to be produced. Because the SRS CA has projected reasonable end-state impacts from 2002 and beyond, and the AER monitoring can differentiate and separate operating and end-state contributions to annual liquid pathway release, an opportunity exists to use the AER monitoring data to validate the SRS CA model.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dose Calculation Methodology and Data for Solid Waste Performance Assessment and Composite Analysis at the Savannah River Site

This report provides a detailed description of the methodology developed to perform dose calculations for E-Area Low Level Waste Facility Performance Assessments and Savannah River Site Composite Analyses. Chapters 2 – 8 give a complete set of equations to be used to calculate dose for individual exposure pathways. The first set of dose scenarios assume that a member of the public establishes residence near the waste site and uses contaminated groundwater or contaminated surface water for personal consumption and to irrigate a garden and pasture where produce and farm animals are raised. Products from the garden and farm animals are used for personal consumption. This scenario applies to both E-Area Performance Assessments and Savannah River Site Composite Analyses. General dose exposure pathways for the resident farmer scenario are: 1. Ingestion pathways described in Chapter 2, 2. Inhalation pathways described in Chapter 3, 3. External exposure pathways described in Chapter 4, and 4. Recreational pathways described in Chapter 5 (Composite Analysis only). Doses from all of the above pathways are directly related to the contaminant concentration in the water. Additional dose scenarios considered for E-Area Performance Assessment assume that an inadvertent intruder encroaches on the waste disposal site after loss of institutional control. General dose exposure pathways considered for the inadvertent intruder are: 1. Ingestion pathways described in Chapter 6, 2. Inhalation pathways described in Chapter 7, and 3. External exposure pathways described in Chapter 8. Doses from all of the intruder pathways are directly related to the contaminant concentration in the buried waste. Special dose considerations related to human consumption of meat and dairy, and treatment of tritium in dose calculations are discussed in Chapter 9. Chapter 10 describes an Excel database named “Radionuclide, Element and Dose Parameter Data Package” that has been created to provide a system for maintaining the data required to perform radionuclide transport and dose calculations. This data includes: Isotope physical parameters and radioactive decay data needed for both transport and dose calculations, Isotope-specific dose coefficients and soil shielding factors associated with exposure pathways, Radionuclide drinking water concentration limits either published by the Environmental Protection Agency or derived from internal dose coefficients to meet the groundwater protection requirements in Department of Energy Order 435.1, Element-specific bio-transfer factors used in dose calculations, Dose equations and values of physical parameters and human factors used in dose calculations, and Key physical constants used in dose calculations. Revision 1 incorporates updated information developed since this report was issued for use in the next revision of the E-Area Low-Level Waste Facility Performance Assessment.

54 ENVIRONMENTAL SCIENCES↗

FY2017 Savannah River Site composite analysis annual review

The FY2017 Department of Energy (DOE) Order 435.1, Radioactive Waste Management (DOE 1999c), Annual Review for the Savannah River Site (SRS) Composite Analysis (CA) is documented, herein.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TU-FG-201-07: Development of SRS Conical Collimator Collision Prediction Software for Radiation Treatment Safety

Purpose: Stereotactic radiosurgery (SRS) treatments using conical collimators can potentially result in gantry collision with treatment table due to limited collision-clear spaces. An in-house software was developed to help the SRS treatment planner mitigate potential SRS conical collimator (Varian Medical System, Palo Alto, CA) collisions with the treatment table. This software was designed to remove treatment re-planning secondary to unexpected collisions. Methods: A BrainLAB SRS ICT Frameless Extension used for SRS treatments in our clinic was mathematically modelled using surface points registered to the 3D co-ordinate space of the couch extension. The surface points are transformed based on the treatment isocenter point and potential collisions are determined in 3D space for couch and gantry angle combinations. The distance between the SRS conical collimators and LINAC isocenter is known. The collision detection model was programmed in MATLAB (Mathwork, Natick, MA) to display graphical plots of the calculations, and the plotted data is used to avoid the gantry and couch angle combinations that would likely result in a collision. We have utilized the cone collision tool for 23 SRS cone treatment plans (8 retrospective and 15 prospective for 10 patients). Results: Twenty one plans strongly agreed with the software tool prediction for collision. However, in two plans, a collision was observed with a 0.5 cm margin when the software predicted no collision. Therefore, additional margins were added to the clearance criteria in the program to achieve a lower risk of actual collisions. Conclusion: Our in-house developed collision check software successfully avoided SRS cone re-planning by 91.3% due to a reduction in cone collisions with the treatment table. Future developments to our software will include a CT image data set based collision prediction model as well as a beam angle optimization tool to avoid normal critical tissues as well as previously treated lesions.

60 APPLIED LIFE SCIENCES↗

High resolution variability in wet deposition in the southeastern United States

Rainwater chemistry is determined by atmospheric pollutants and particles which vary spatially and temporally. Industrial and agricultural activities and meteorological events (e.g. sea breezes, severe weather, blowing dust) alter atmospheric particle and trace gas compositions. These gases and particles are scavenged by cloud and rain droplets that drive wet deposition. During an Intensive Operation Period (IOP) from April to October 2021, rainwater was collected at higher frequency intervals, usually daily, after precipitation events at three locations on the Savannah River Site (SRS). The farthest locations were separated by approximately 20 km. The mean concentration (μeq/L) of seven ions followed the Cl⁻ > SO 4 2− > Na⁺ > NO 3 ⁻ > K⁺ > Mg 2+ > Ca 2+ downward trend. Ion concentrations were compared to background ion concentrations from the National Atmospheric Deposition Program (NADP). The high frequency monthly averaged SRS data compared well with the monthly averaged NADP background but demonstrated extensive variability. In some months in 2021, the high frequency data compared better to the NADP site near the coast while in other months inland sites compared better. Strong spatial variability for ion concentrations was observed across SRS which was attributed to localized impacts in rainfall spatial variability. High frequency measurements allowed for comparison to regional weather patterns indicating influences from the Atlantic Ocean, Gulf of Mexico, and cities. This can account for spatial variability in the wet deposition flux. Sea breezes, Saharan dust, and anthropogenic sources were shown to impact wet deposition flux variability. Higher frequency precipitation chemistry sampling at numerous locations better captures ion concentration variability and improves measurement representativeness.

54 ENVIRONMENTAL SCIENCES↗

Cyberknife stereotactic radiosurgery and radiation therapy treatment planning system

CyberKnife is an image-guided stereotactical dose delivery system designed for both focal irradiation and radiation therapy (SRT). Focal irradiation refers the use of many small beams to deliver highly focus dose to a small target region in a few fractions. The system consists of a 6-MV linac mounted to a robotic arm, coupled with a digital x-ray imaging system. The radiation dose is delivered using many beams oriented at a number of defined or nodal positions around the patients. The CyberKnife can be used for both intracranial and extracranial treaments unlike the Gamma Knife which is limited to intracranial cases. Multiplan (Accuray Inc., Sunnyvale, CA) is the treatment planning system developed to cooperate with this accurate and versatile SRS and SRT system, and exploit the full function of Cyberknife in high-precision radiosurgery and therapy. Optimized inverse treatment plan can be achieved by fine-tuning contours and planning parameters. Precision is the newest version of Cyberknife treatment planning system (TPS) and an upgrade to Multiplan. It offers several new features such as Monte Carlo for multileaf collimator (MLC) and retreatment for other modalities that added more support for the Cyberknife system. The Cybeknife TPS is an easy-to-use and versatile inverse planning platform, suitable for stereotactic radiosurgery and radiation therapy. The knowledge and experience of the planner in this TPS is essential to improve the quality of patient care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geochemical Data Package for Performance Assessment Calculations Related to the Savannah River Site

The Savannah River Site (SRS) disposes of low-level radioactive waste (LLW) and stabilizes high-level radioactive waste (HLW) tanks in the subsurface environment. Calculations used to establish the radiological limits of these facilities are referred to as Performance Assessments (PA), Special Analyses (SA), and Composite Analyses (CA). The objective of this document is to revise existing geochemical input values used for these calculations. This work builds on earlier compilations of geochemical data (2007, 2010), referred to a geochemical data packages. This work is being conducted as part of the on-going maintenance program of the SRS PA programs that periodically updates calculations and data packages when new information becomes available. Because application of values without full understanding of their original purpose may lead to misuse, this document also provides the geochemical conceptual model, the approach used for selecting the values, the justification for selecting data, and the assumptions made to assure that the conceptual and numerical geochemical models are reasonably conservative (i.e., bias the recommended input values to reflect conditions that will tend to predict the maximum risk to the hypothetical recipient). This document provides 1088 input parameters for geochemical parameters describing transport processes for 64 elements (>740 radioisotopes) potentially occurring within eight subsurface disposal or tank closure areas: Slit Trenches (ST), Engineered Trenches (ET), Low Activity Waste Vault (LAWV), Intermediate Level (ILV) Vaults, Naval Reactor Component Disposal Areas (NRCDA), Components-in-Grout (CIG) Trenches, Saltstone Facility, and Closed Liquid Waste Tanks. The geochemical parameters described here are the distribution coefficient, Kd value, apparent solubility concentration, k s value, and the cementitious leachate impact factor.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Direct evidence of the effect of a moderate external magnetic field on stimulated Raman scattering in the kinetic regime

We present results from an experiment carried out at the OMEGA-EP laser facility that investigated the effect of a perpendicular magnetic field on stimulated Raman scattering (SRS) and report the first direct measurement of magnetic mitigation of SRS. A 13-T magnetic field generated by pulsed-power coils was imposed on a gas jet plasma, and a novel three-picket interaction beam was used to explore SRS reflectivity for several plasma conditions within single shots. The time-resolved backscattered light shows that SRS was mitigated by the external 13-T magnetic field in the kinetic regime (kλ D ∼ 0.3, where k is the electron plasma wave's wavenumber and λ D is electron Debye length) and at a density of n e /n cr ∼ 0.10. On the other hand, we also measured an enhancement of SRS reflectivity at lower density (n e /n cr < 0.08). We discuss experimental results in the context of magnetohydrodynamic and particle-in-cell simulations that scan SRS dynamics for a variety of plasma conditions. While the experimental evidence of SRS mitigation validates prior work on the kinetic simulation of SRS in an external magnetic field, we also find that other mechanisms such as SRS rescatter can lead to an enhancement of measured SRS reflectivity in simulations of parameters relevant to our experiment.

Gas jet↗

FY2020 performance assessment annual review for the E-area low-level waste facility

The Savannah River Site (SRS) E-Area Low-Level Waste Facility (ELLWF) consists of six types of disposal units described in the Performance Assessment (PA) (WSRC, 2008): Low Activity Waste Vault (LAWV), Intermediate Level Vault (ILV), Trenches [Slit Trenches (STs), Engineered Trenches (ETs), and Component-in-Grout (CIG) Trenches], and Naval Reactor Component Disposal Areas (NRCDAs). The ELLWF is a part of the Solid Waste Management Facility (SWMF). SWMF is managed and operated by the SRS Management and Operations prime contractor, Savannah River Nuclear Solutions (SRNS). Within SRNS, the Solid Waste Management (SWM) organization is responsible for operating the SWMF, and the Savannah River National Laboratory (SRNL) is the technical agency responsible for preparing and maintaining the PA. SWMF operations have been performed at SRS since 1952. The mission of the SWMF is to provide storage, processing, disposal, and shipment of radioactive, hazardous, and mixed waste. The SWMF is committed to treat, store, and dispose of these waste products in a manner that protects the environment and the health and safety of the facility worker, the co-located worker, and the offsite general public. Wastes handled in the SWMF include low level waste, transuranic waste, hazardous waste, Toxic Substances Control Act waste, and mixed waste (containing both hazardous and radioactive constituents). The FY2020 PA Annual Review for the ELLWF affirms that the disposal facility continued to operate within the bounds of the current PA and Composite Analysis (CA) baseline and the subsequent SA’s and satisfied all the requirements, conditions, and limitations identified in the 2008 DAS (DOE 2008a), RWMB SRNL_STI-2020-00588 Revision 0 vi (McGill, 2020), and ELLWF Low-Level Waste Acceptance Criteria (SRS-1S, 2014). This annual review affirms that the supporting studies performed in FY2020 do not alter the conclusions of the ELLWF PA (WSRC, 2008) and that there is a reasonable expectation that the ELLWF will meet the performance objectives delineated in DOE Manual 435.1-1 (DOE 2011)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Updated Results of the Nuclear Accident Dosimetry Intercomparison at the Armed Forces Radiobiology Research Institute’s TRIGA Reactor (IER-602 CED-4a Report)

The IER-602 3b document (Angus, et al. 2024) reported the initial, 24-hour results of the international nuclear accident intercomparison, which took place at the Armed Forces Radiobiological Research Institute during June 24-28, 2024. This report provides updated results and further analysis of the intercomparison.

61 RADIATION PROTECTION AND DOSIMETRY↗

Decimeter-scale mapping of carbonate-controlled trace element distribution in Neoarchean cuspate stromatolites

We present that ancient stromatolites can provide key insights into the early evolution of life on Earth. Neoarchean fenestrate stromatolites from the ~2520 Ma Upper Nauga Formation (Transvaal Supergroup, South Africa) preserve cuspate morphologies. They possess clearly delineated support and drape structures interpreted as dolomitized microbial mat material. Petrographic observations show that the biogenic structures are composed of planar-s to non-planar ferroan dolomite, encased in ferroan calcite, including herringbone calcite textures. The cuspate stromatolites were analyzed using Synchrotron Rapid Scanning X-Ray Fluorescence (SRS-XRF) and more conventional techniques to determine: (i) whether element distributions could be distinguished in ancient stromatolites at both cm to dm scales, (ii) whether element distributions show variation between biogenic and abiogenic textures, and (iii) the sample’s paragenesis. The distributions of Ca, Fe, Mn, Pb, Cu, As, Br, Al, Si, P, and S directly correspond to dolomitized stromatolitic structures and show trace element distributions are principally controlled by calcite and dolomite occurrence. Dolomite formation was mainly driven by seawater-derived fluids given the high concentrations of Fe and retention of marine shale-normalized rare earth element and yttrium (REY SN ) patterns, however the spatial association of dolomite to stromatolite structures may reflect microbially-influenced mineral nucleation. Lastly, given the complexity of this sample’s paragenetic evolution, trace metal distributions cannot be conclusively tied to specific metabolic pathways, bioaccumulation or passive binding, however, the results show SRS-XRF can be used for quantifiable, spatial, in-situ investigation of ancient microbialites.

58 GEOSCIENCES↗

User Guide for GoldSim Model to Calculate PA/CA Doses and Limits

A model to calculate doses for solid waste disposal at the Savannah River Site (SRS) and corresponding disposal limits has been developed using the GoldSim commercial software. The model implements the dose calculations documented in SRNL-STI-2015-00056, Rev. 0 “Dose Calculation Methodology and Data for Solid Waste Performance Assessment (PA) and Composite Analysis (CA) at the Savannah River Site”.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Accuracy evaluation of the optical surface monitoring system on EDGE linear accelerator in a phantom study

Frameless stereotactic radiosurgery (SRS) requires dedicated systems to monitor the patient position during the treatment to avoid target underdosage due to involuntary shift. The optical surface monitoring system (OSMS) is here evaluated in a phantom-based study. The new EDGE linear accelerator from Varian (Varian, Palo Alto, CA) integrates, for cranial lesions, the common cone beam computed tomography (CBCT) and kV-MV portal images to the optical surface monitoring system (OSMS), a device able to detect real-time patient's face movements in all 6 couch axes (vertical, longitudinal, lateral, rotation along the vertical axis, pitch, and roll). We have evaluated the OSMS imaging capability in checking the phantoms' position and monitoring its motion. With this aim, a home-made cranial phantom was developed to evaluate the OSMS accuracy in 4 different experiments: (1) comparison with CBCT in isocenter location, (2) capability to recognize predefined shifts up to 2° or 3 cm, (3) evaluation at different couch angles, (4) ability to properly reconstruct the surface when the linac gantry visually block one of the cameras. The OSMS system showed, with a phantom, to be accurate for positioning in respect to the CBCT imaging system with differences of 0.6 ± 0.3 mm for linear vector displacement, with a maximum rotational inaccuracy of 0.3°. OSMS presented an accuracy of 0.3 mm for displacement up to 1 cm and 1°, and 0.5 mm for larger displacements. Different couch angles (45° and 90°) induced a mean vector uncertainty < 0.4 mm. Coverage of 1 camera produced an uncertainty < 0.5 mm. Translations and rotations of a phantom can be accurately detect with the optical surface detector system.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of seasonal anoxia on geochemical cycling in a stratified pond: Comparison to cooler pond conditions 40 years ago

Seasonal stratification in temperate lakes deeper than a few meters creates favorable conditions for pronounced vertical redox zones, often resulting in anaerobic hypolimnions and significant geochemical changes. Here, this study examined thermocline formation and trace element behavior in a seasonally stratified pond amid rising air temperatures. Over two years, data were collected from Pond B at the US Department of Energy Savannah River Site in Aiken, South Carolina. Pond B, a man-made monomictic reservoir, received cooling water from a nuclear reactor from 1961 to 1964. Strong thermal stratification forms a distinct thermocline in May and progresses downward until November. Compared to the 1980s, this study shows a delayed onset and extended duration of stratification. The prolonged summer stratification reduces deep water oxygen replenishment, extending hypoxic conditions. Trace and major elements sampled in the water column revealed strong correlations between As, Fe, and Mn profiles, with concentrations increasing by 1–2 orders of magnitude in the anaerobic hypolimnion. This period captured the seasonal transition from winter mixing to summer stratification to fall overturn. Under anoxic conditions, Fe(III) reduces to Fe(II) in the sediment, releasing dissolved iron into the water column. The extended anoxic periods likely promoted arsenic release from sediments. Prolonged anoxia may enhance arsenic mobilization and solubility in the lake. This study illustrates how climate-induced changes in seasonal stratification of contaminated waters can convert contaminant sinks into sources, offering insights into the cycling of arsenic and other dissolved ions in stratified lakes and their implications for water quality management.

Anoxic conditions↗

Multivariate environmental and trait-based controls of transpiration in the Central Amazon Rainforest

Tropical forest tree mortality is increasing due to more severe droughts, yet our understanding of how tree traits and life strategies are linked to drought stress has been limited by measurement scarcity. The BIONTE (BIOmass and NuTrient Experiment) near Manaus, Brazil hosts one of the world’s largest sap flow installations, with sensors in 90 canopy trees across a wood density gradient monitored since June 2022. The 2023 El Niño drought provided a unique opportunity to evaluate how water availability impacts tree transpiration. An interpretable machine learning framework was used to study the complex interactions between transpiration and multiple environmental variables such as soil water availability and vapor pressure deficit (VPD), and how these interactions vary with wood density and individual trees. We found varying responses of transpiration from different trees during the El Niño drought. Transpiration generally increased with temperature, with stronger effects in wetter areas and in trees with low to medium wood density. However, this response was modulated by stomatal sensitivity to VPD, which constrained transpiration under high atmospheric demand, particularly in intermediate-moisture area. The inflection in transpiration rate at high temperatures (>32°C) underscores the role of stomatal and hydraulic regulation in limiting water loss and protecting trees from excessive evaporative demand. Analysis of soil water contribution to transpiration revealed unimodal patterns in wetter area, with peak contributions near 0.45 cm 3 cm -3 of surface soil water and declining or flat responses beyond that threshold, suggesting a shift from water- to energy-limited transpiration. In contrast, drier areas exhibited limited transpiration sensitivity to soil water conditions and minimal trait-based variation in VPD responses, indicating supply-limited conditions. Despite higher wood density trees being generally more resilient, this study shows diverse tree drought resilience, prompting further investigation into the specific traits and dynamics between environmental variables in regulating transpiration and other physiological processes in trees.

Drought↗