Search NASA⌕ Search

SEARCH · Search NASA

Results for “STAINS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Structural and Biophysical Characterization of the Mycobacterium tuberculosis Protein Rv0577, a Protein Associated with Neutral Red Staining of Virulent Tuberculosis Strains and Homologue of the Streptomyces coelicolor Protein KbpA

The 261-residue Mycobacterium tuberculosis protein Rv0577 is a prominent antigen in tuberculosis patients, the responsible component for neutral red staining of virulent strains of M. tuberculosis, a putative component in a methylglyoxal detoxification pathway, and an agonist of toll-like receptor 2. It also has 36% sequence identity to AfsK-binding protein A (KbpA), a component in the complex secondary metabolite pathways in the Streptomycetes genus from which many commercial antibiotics are derived. To gain insight into the biological function of Rv0577 and the family of KpbA kinase regulators, the crystal structure for Rv0577 was determined to a resolution of 1.75 Å (3OXH), binding properties with neutral red and deoxyadenosine (Ado) surveyed, backbone dynamics measured, and thermal stability assayed by CD spectroscopy. The protein is composed of four approximate repeats with an topology arranged radially in consecutive pairs to form two continuous eight-strand -sheets capped on both ends with an -helix. The two -sheets intersect in the center at roughly a right angle and form an asymmetric deep “saddle” on both sides of the protein, saddle one (P11 to A129) and saddle two (L143 to A258), that may serve to bind ligands. NMR chemical shift perturbation experiments show that neutral red binds to Rv0577, further cementing the role of Rv0577 in the neutral red staining of virulent strains of M. tuberculosis. Similar experiments show that adenosine also bind to Rv0577, although less tightly, with estimated dissociation constants of 4.1 ± 0.3 mM for saddle one and > 1 M for saddle two. Heteronuclear steady-state {1H}-15N NOE, T1, and T2 values were generally uniform through-out the sequence with only a few modest pockets of differences suggestive of slightly different motion in loops between -strands in saddle 1. Circular dichroism spectroscopy characterization of the thermal stability of Rv0577 indicated irreversible unfolding upon heating with an estimated melting temperature of 56 °C. While it is not known if Rv0577 has a kinase regulatory role similar to its Streptomyces homolog KbpA, protein kinase and phosphatase signaling help M. tuberculosis adapt to the hostile host environment during infections. Consequently, new anti-tuberculosis drugs targeting Rv0577 may act by interfering with multiple mechanisms; a potential signaling machinery as well as toll-like receptor 2 activation and the methylglyoxal detoxification pathway.

59 BASIC BIOLOGICAL SCIENCES↗

Tetranuclear Polypyridylruthenium(II) Complexes as Selective Nucleic Acid Stains for Flow Cytometric Analysis of Monocytic and Epithelial Lung Carcinoma Large Extracellular Vesicles

Selective staining of extracellular vesicles (EVs) is a major challenge for diagnostic and therapeutic applications. Herein, the EV labeling properties of a new class of tetranuclear polypyridylruthenium(II) complexes, Rubb7-TNL and Rubb7-TL, as phosphorescent stains are described. These new stains have many advantages over standard stains to detect and characterize EVs, including: high specificity for EV staining versus cell staining; high phosphorescence yields; photostability; and a lack of leaching from EVs until incorporation with target cells. As an example of their utility, large EVs released from control (basal) or lipopolysaccharide (LPS)-stimulated THP-1 monocytic leukemia cells were studied as a model of immune system EVs released during bacterial infection. Key findings from EV staining combined with flow cytometry were as follows: (i) LPS-stimulated THP-1 cells generated significantly larger and more numerous large EVs, as compared with those from unstimulated cells; (ii) EVs retained native EV physical properties after staining; and (iii) the new stains selectively differentiated intact large EVs from artificial liposomes, which are models of cell membrane fragments or other lipid-containing debris, as well as distinguished two distinct subpopulations of monocytic EVs within the same experiment, as a result of biochemical differences between unstimulated and LPS-stimulated monocytes. Comparatively, the staining patterns of A549 epithelial lung carcinoma-derived EVs closely resembled those of THP-1 cell line-derived EVs, which highlighted similarities in their selective staining despite their distinct cellular origins. This is consistent with the hypothesis that these new phosphorescent stains target RNA within the EVs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Near‐UV laser treatment of extrinsic dental enamel stains

Abstract Background and Objectives The selective ablation of extrinsic dental enamel stains using a 400‐nm laser is evaluated at several fluences for completely removing stains with minimal damage to the underlying enamel. Study Design/Materials and Methods A frequency‐doubled Ti:sapphire laser (400‐nm wavelength, 60‐nanosecond pulse duration, 10‐Hz repetition rate) was used to treat 10 extracted human teeth with extrinsic enamel staining. Each tooth was irradiated perpendicular to the surface in a back‐and‐forth motion over a 1‐mm length using an ∼300‐µm‐diam 10th‐order super‐Gaussian beam with fluences ranging from 0.8 to 6.4 J/cm 2 . Laser triangulation determined stain depth and volume removed by measuring 3D surface images before and after irradiation. Scanning electron microscopy evaluated the surface roughness of enamel following stain removal. Fluorescence spectroscopy measured spectra of unbleached and photobleached stains in the spectral range of 600–800 nm. Results Extrinsic enamel stains are removed with laser fluences between 0.8 and 6.4 J/cm 2 . Stains removed on sound enamel leave behind a smooth enamel surface. Stain removal in areas with signs of earlier cariogenic acid attacks resulted in isolated and randomly located laser‐induced, 50‐µm‐diam enamel pits. These pits contain 0.5‐µm diam, smooth craters indicative of heat transfer from the stain to the enamel and subsequent melting and water droplet ejection. Ablation stalling of enamel stains is typically observed at low fluences (<3 J/cm 2 ) and is accompanied by a drastic reduction in porphyrin fluorescence from the Soret band. Conclusion Laser ablation of extrinsic enamel stains at 400 nm is observed to be most efficient above 3 J/cm 2 with minimal damage to the underlying enamel. Unsound underlying enamel is also observed to be selectively removed after irradiation. Lasers Surg. Med. 44:339–345, 2012. © 2012 Wiley Periodicals, Inc.

enamel melting↗

Acridine orange staining reaction as an index of physiological activity in Escherichia coli

The assumption that the acridine orange (AO) color reaction may be used as an index of physiological activity was investigated in laboratory grown Escherichia coli. Spectrofluorometric observations of purified nucleic acids, ribosomes and the microscopic color of bacteriophage-infected cells stained with AO confirmed the theory that single-stranded nucleic acids emit orange to red fluorescence while those that are double-stranded fluoresce green in vivo. Bacteria growing actively in a rich medium could be distinguished from cells in stationary phase by the AO reaction. Cells from log phase appeared red, whereas those in stationary phase were green. However, this differentiation was not seen when the bacteria were grown in a minimal medium or when a variation of the staining method was used. Also, shifting bacteria in stationary phase to starvation conditions rapidly changed their AO staining reaction. Boiling and exposure to lethal concentrations of azide and formalin resulted in stationary-phase cells that appeared red after staining but bacteria killed with chlorine remained green. These findings indicate that the AO staining reaction may be suggestive of physiological activity under defined conditions. However, variables in staining and fixation procedures as well as uncertainties associated with mixed bacterial populations in environmental samples may produce results that are not consistent with the classical interpretation of this reaction. The importance of validating the putative physiological implications of this staining reaction is stressed.

NASA Discipline Number 04-10↗

Apparatus Would Stain Microscope Slides

Proposed apparatus meters specific amounts of fluid out of containers at specific times to stain microscope slides. Intended specifically for semiautomated staining of microbiological and hematological samples in microgravity, leakproof apparatus used in other environments in which technicians have little time to allocate to staining procedures and/or exposure to toxic staining agents or to micro-organisms to be stained hazardous. Apparatus adapted to perform almost any staining procedure and accommodates multiple staining reagents, useful for small or remote clinical laboratories.

Breeding, James D.↗

Western Blot of Stained Proteins from Dried Polyacrylamide Gels

Western blotting of proteins is customarily performed following their separation on polyacrylamide gels, either prior to staining (1) or, as recently reported, following staining (2). We describe here Western blotting with stained gels, which had been dried and some of which had been stored for years. This procedure permits immunological analysis of proteins, to which antisera may have become available only later, or where the application of newly developed sensitive detection methods is desired. Once rehydration of the gels is achieved, proteins can be-transferred to blotting membranes by any appropriate protocol. Proteins stained with Coomassie Blue have to be detected with a non-chromogenic method, such as the film-based enhanced chemiluminescence (ECL)2) procedure (3). Silver stained proteins, which transfer in the colorless form, may be visualized by any detection method, although, because of the usually very low amounts of proteins, detection by ECL is preferable. Blotting of stained proteins from rehydrated gels is as rapid and as quantitative as from freshly prepared gels, in contrast to blotting from wet stained gels, which requires extensive washing and results in low transfer efficiency (2). Together with a photographic record of the gel pattern, unambiguous identification of immunoreactive proteins from complex mixtures is possible. Some further applications of this work are discussed.

Gruber, Claudia↗

Compact, Automated Centrifugal Slide-Staining System

The Directional Acceleration Vector-Driven Displacement of Fluids (DAVD-DOF) system, under development at the time of reporting the information for this article, would be a relatively compact, automated, centrifugally actuated system for staining blood smears and other microbiological samples on glass microscope slides in either a microgravitational or a normal Earth gravitational environment. The DAVD-DOF concept is a successor to the centrifuge-operated slide stainer (COSS) concept, which was reported in Slide-Staining System for Microgravity or Gravity (MSC-22949), NASA Tech Briefs, Vol. 25, No. 1 (January, 2001), page 64. The COSS includes reservoirs and a staining chamber that contains a microscope slide to which a biological sample is affixed. The staining chamber is sequentially filled with and drained of staining and related liquids from the reservoirs by use of a weighted plunger to force liquid from one reservoir to another at a constant level of hypergravity maintained in a standard swing-bucket centrifuge. In the DAVD-DOF system, a staining chamber containing a sample would also be sequentially filled and emptied, but with important differences. Instead of a simple microscope slide, one would use a special microscope slide on which would be fabricated a network of very small reservoirs and narrow channels connected to a staining chamber (see figure). Unlike in the COSS, displacement of liquid would be effected by use of the weight of the liquid itself, rather than the weight of a plunger.

Feeback, Daniel L.↗

Specimen block counter-staining for localization of GUS expression in transgenic arabidopsis and tobacco

A simple counter-staining procedure has been developed for comparative beta-glucuronidase (GUS) expression and anatomical localization in transgenic herbaceous arabidopsis and tobacco. This protocol provides good anatomical visualization for monitoring chimeric gene expression at both the organ and tissue levels. It can be used with different histochemical stains and can be extended to the study of woody species. The specimens are paraffin-embedded, the block is trimmed to reveal internal structure, safranin-O staining solution is briefly applied to the surface of the block, then washed off and, after drying, a drop of immersion oil is placed on the stained surface for subsequent photographic work. This gives tissue counter-staining with good structural preservation without loss of GUS staining product; moreover, sample observation is rapid and efficient compared to existing procedures.

NASA Discipline Plant Biology↗

Evaluation of Ki-67 Staining Levels as an Independent Biomarker of Biochemical Recurrence After Salvage Radiation Therapy for Prostate Cancer

Purpose: We recently published a scoring algorithm to predict biochemical recurrence (BCR) after salvage radiation therapy (SRT) for prostate cancer. Currently, this algorithm is based on clinicopathologic features and does not incorporate information from tumor-based biomarkers. Herein, we evaluate the ability of Ki-67 staining in primary prostate cancer to independently aid in the prediction of BCR among men undergoing SRT. Methods and Materials: We identified 147 patients who were treated with SRT between July 1987 and July 2003 at Mayo Clinic (Rochester, MN; Jacksonville, FL; Scottsdale, AZ). Staining levels of Ki-67 in primary tumor samples were detected by use of a monoclonal antibody and quantified by use of a computer-assisted method. We used Cox proportional hazards models to examine the association of Ki-67 staining and BCR in single-variable models and after multivariable adjustment. Results: The risk of BCR for men with tumors in the highest tertile of Ki-67 staining is approximately two times that for men with tumors in the lower two tertiles (relative risk, 2.02; 95% confidence interval, 1.23-3.32; p = 0.005) after adjustment for the features in our original scoring algorithm. Further adjustment for additional covariates did not attenuate this association. Evidence from concordance index values supports that Ki-67 staining adds to the predictive ability of our existing scoring algorithm. Conclusions: Our data suggest that higher levels of Ki-67 staining are associated with increased risk of BCR after SRT, independent of existing clinicopathologic covariates. Future studies involving larger numbers of patients are required to validate these results and also explore possible means of combining this biomarker with existing prognostic tools.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visible luminescence from silicon wafers subjected to stain etches

Etching of Si in a variety of solutions is known to cause staining. These stain layers consist of porous material similar to that produced by anodic etching of Si in HF solutions. In this work, photoluminescence peaked in the red from stain-etched Si wafers of different dopant types, concentrations, and orientations produced in solutions of HF:HNO3:H2O was observed. Luminescence is also observed in stain films produced in solutions of NaNO2 in HF, but not in stain films produced in solutions of CrO3 in HF. The luminescence spectra are similar to those reported recently for porous Si films produced by anodic etching in HF solutions. However, stain films are much easier to produce, requiring no special equipment.

Fathauer, R. W.↗

Improved Whole-Blood-Staining Device

Dramatic improvements have been made in NASA s Whole Blood Staining Device (WBSD) since it was last described in "Whole-Blood-Staining Device," NASA Tech Briefs, Vol. 23, No. 10 (October 1999), page 64. The new system has a longer shelf life, a simpler and more effective operational procedure, improved interface with instrumentation, and shorter processing time. More specifically, the improvements have targeted bag and locking clip materials, sampling ports, and air pocket prevention. The WBSD stains whole blood collected during spaceflight for subsequent flow cytometric analysis. In short, the main device stains white blood cells by use of monoclonal antibodies conjugated to various fluorochromes, followed by lysing and fixing of the cells by use of a commercial reagent that has been diluted according to NASA safety standards. This system is compact, robust, and does not require electric power, precise mixing, or precise incubation times. Figure 1 depicts the present improved version for staining applications, which is a poly(tetrafluoroethylene) bag with a Luer-lock port and plastic locking clips. An InterLink (or equivalent) intravenous- injection port screws into the Luer-lock port. The inflatable/collapsible nature of the bag facilitates loading and helps to minimize the amount of air trapped in the fully loaded bag. Some additional uses have been identified for the device beyond whole blood staining. The WBSD has been configured for functional assays that require culture of live cells by housing sterile culture media, mitogens, and fixatives prior to use [Figure 2(a)]. Simple injection of whole blood allows cell-stimulation culture to be performed in reduced gravity conditions, and product stabilization prior to storage, while protecting astronauts from liquid biohazardous materials. Also, the improved WBSD has reconstituted powdered injectable antibiotics by mixing them with diluent liquids [Figure 2(b)]. Although such mixing can readily be performed on Earth by shaking in glass vials, it cannot readily be performed this way in outer space without entraining air bubbles. The present device can be preloaded with the powder and diluent(s) in separate compartments. The powder and diluent( s) can be mixed, without introducing air bubbles, by removing the clip(s), then shaking. This use of the device could also be advantageous in terrestrial applications because it maintains the isolation of the constituents until the time of use.

Sams, Clarence F.↗

The use of a spaceflight-compatible device to perform WBC surface marker staining and whole-blood mitogenic activation for cytokine detection by flow cytometry

Significant changes have recently been described regarding circulating peripheral immune cells immediately following spaceflight. Existing methods for immunophenotype staining of peripheral blood in terrestrial labs do not meet the constraints for flight on the Space Shuttle. We have recently described the development and use of the Whole Blood Staining Device (WBSD), a simple device for staining flow cytometry specimens during spaceflight. When preparing samples with the WBSD, all liquids are safely contained as the cells are moved through staining, lysis and fixation steps. Here we briefly review the use of the WBSD, and then describe another versatile adaptation, a modification to perform intracellular staining of cytokines for detection by flow cytometry. Alterations in cytokine production have been reported both in ground-based simulated microgravity culture and in astronaut samples returning from spaceflight. Data regarding microgravity effects on cytokine production for specific subpopulations of cells is lacking. Flow cytometric cytokine analysis offers the unique ability to perform simultaneous surface marker analysis and positively identity cytokine producing subsets of cells. The utilization of the WBSD provides the ability to perform rapid and routine mitogenic activation during spaceflight coupled with the ability to perform simultaneous surface marker analysis. The only external requirements for this procedure are an in-flight 37-degree incubator and the capacity for 4-degree storage.

NASA Discipline Regulatory Physiology↗

Automated single-slide staining device

An automatic single-slide Gram staining device is described. A timer-actuated solenoid controls the dispensing of gentian violet, Gram iodine solution, decolorizer, and 1% aqueous safranin in proper sequence and for the time required for optimum staining. The amount of stain or reagent delivered is controlled by means of stopcocks below each solenoid. Used stains and reagents can be flushed automatically or manually. Smears Gram stained automatically are equal in quality to those prepared manually. The time to complete one Gram cycle is 4.80 min.

Wilkins, J. R.↗

Identifying motor and sensory myelinated axons in rabbit peripheral nerves by histochemical staining for carbonic anhydrase and cholinesterase activities

Carbonic anhydrase (CA) and cholinesterase (CE) histochemical staining of rabbit spinal nerve roots and dorsal root ganglia demonstrated that among the reactive myeliated axons, with minor exceptions, sensory axons were CA positive and CE negative whereas motor axons were CA negative and CE positive. The high specificity was achieved by adjusting reaction conditions to stain subpopulations of myelinated axons selectively while leaving 50 percent or so unstained. Fixation with glutaraldehyde appeared necessary for achieving selectivity. Following sciatic nerve transection, the reciprocal staining pattern persisted in damaged axons and their regenerating processes which formed neuromas within the proximal nerve stump. Within the neuromas, CA-stained sensory processes were elaborated earlier and in greater numbers than CE-stained regenerating motor processes. The present results indicate that histochemical axon typing can be exploited to reveal heterogeneous responses of motor and sensory axons to injury.

Riley, Danny A.↗

Centrifuge-operated specimen staining method and apparatus

A method of staining preselected, mounted specimens of either biological or nonbiological material enclosed within a staining chamber where the liquid staining reagents are applied and removed from the staining chamber using hypergravity as the propelling force. In the preferred embodiment, a spacecraft-operated centrifuge and method of diagnosing biological specimens while in orbit, characterized by hermetically sealing a shell assembly. The assembly contains slide stain apparatus with computer control therefor, the operative effect of which is to overcome microgravity, for example on board an International Space Station.

Clarke, Mark S. F.↗

Gram staining apparatus for space station applications

A self-contained, portable Gram staining apparatus (GSA) has been developed for use in the microgravity environment on board the Space Station Freedom. Accuracy and reproducibility of this apparatus compared with the conventional Gram staining method were evaluated by using gram-negative and gram-positive controls and different species of bacteria grown in pure cultures. A subsequent study was designed to assess the performance of the GSA with actual specimens. A set of 60 human and environmental specimens was evaluated with the GSA and the conventional Gram staining procedure. Data obtained from these studies indicated that the GSA will provide the Gram staining capability needed for the microgravity environment of space.

Gentian Violet↗

Corrosion of 15th and early 16th century stained glass from the monastery of Batalha studied with external ion beam

This paper reports the study of corrosion in two stained glass panels from the south aisle of Sta. Maria da Vitoria monastery, at Batalha (Portugal), one depicting the Last Supper (dated from 1508), and the other one showing a saint (c. 1450). These panels exhibit extensive corrosion with darkening phenomena that are an impediment to their correct visualization, a source of major concern both to conservators and curators. By using external micro-beam Particle Induced X-ray Emission (PIXE) and Particle Induced Gamma Emission (PIGE) spectrometry, the elemental compositions of large fragments were obtained, enabling the selection of representative corroded areas, from which elemental distribution maps were produced by scanning. Calcium and potassium rich structures were found - at the surface and inside cavities in the glass - that were identified as oxalates and carbonates, by Raman microscopy and micro-FTIR. The dark spots present in the glass surfaces were found to be Zn and Pb rich. These findings indicate that the corrosion observed was due not only to reactions with atmospheric water and CO{sub 2} but also with the oxalic acid secreted by micro-organisms. Furthermore, it did not result from reactions with atmospheric SO{sub 2} or acid rain. The information obtained is relevant for a better understanding of the corrosion processes and products formed on the surface of these panels and therefore for the proper planning of much needed adequate conservation-restoration actions and appropriate display conditions. - Research Highlights: {yields} Corrosion and darkening of stained glasses is of concern to conservators and curators. {yields} A multi-technique approach is of relevance to study stained glass corrosion. {yields} External beam PIXE-PIGE provide valuable insight on stained glass corrosion.

36 MATERIALS SCIENCE↗