Search NASA⌕ Search

SEARCH · Search NASA

Results for “STAR-CCM+”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Analysis of Low-Speed Stall Aerodynamics of a Swept Wing with Laminar-Flow Glove

Reynolds-Averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) analysis was conducted to study the low-speed stall aerodynamics of a GIII aircraft s swept wing modified with a laminar-flow wing glove. The stall aerodynamics of the gloved wing were analyzed and compared with the unmodified wing for the flight speed of 120 knots and altitude of 2300 ft above mean sea level (MSL). The Star-CCM+ polyhedral unstructured CFD code was first validated for wing stall predictions using the wing-body geometry from the First AIAA CFD High-Lift Prediction Workshop. It was found that the Star-CCM+ CFD code can produce results that are within the scattering of other CFD codes considered at the workshop. In particular, the Star-CCM+ CFD code was able to predict wing stall for the AIAA wing-body geometry to within 1 degree of angle of attack as compared to benchmark wind-tunnel test data. Current results show that the addition of the laminar-flow wing glove causes the gloved wing to stall much earlier than the unmodified wing. Furthermore, the gloved wing has a different stall characteristic than the clean wing, with no sharp lift drop-off at stall for the gloved wing.

Bui, Trong↗

Analysis of Low-Speed Stall Aerodynamics of a Swept Wing with Laminar-Flow Glove

Reynolds-Averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) analysis was conducted to study the low-speed stall aerodynamics of a GIII aircraft's swept wing modified with a laminar-flow wing glove. The stall aerodynamics of the gloved wing were analyzed and compared with the unmodified wing for the flight speed of 120 knots and altitude of 2300 ft above mean sea level (MSL). The Star-CCM+ polyhedral unstructured CFD code was first validated for wing stall predictions using the wing-body geometry from the First American Institute of Aeronautics and Astronautics (AIAA) CFD High-Lift Prediction Workshop. It was found that the Star-CCM+ CFD code can produce results that are within the scattering of other CFD codes considered at the workshop. In particular, the Star-CCM+ CFD code was able to predict wing stall for the AIAA wing-body geometry to within 1 degree of angle of attack as compared to benchmark wind-tunnel test data. Current results show that the addition of the laminar-flow wing glove causes the gloved wing to stall much earlier than the unmodified wing. Furthermore, the gloved wing has a different stall characteristic than the clean wing, with no sharp lift drop-off at stall for the gloved wing.

Bui, Trong T.↗

Analysis of Low Speed Stall Aerodynamics of a Swept Wing with Laminar Flow Glove

Reynolds-Averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) analysis was conducted to study the low-speed stall aerodynamics of a GIII aircraft's swept wing modified with a laminar-flow wing glove. The stall aerodynamics of the gloved wing were analyzed and compared with the unmodified wing for the flight speed of 120 knots and altitude of 2300 ft above mean sea level (MSL). The Star-CCM+ polyhedral unstructured CFD code was first validated for wing stall predictions using the wing-body geometry from the First American Institute of Aeronautics and Astronautics (AIAA) CFD High-Lift Prediction Workshop. It was found that the Star-CCM+ CFD code can produce results that are within the scattering of other CFD codes considered at the workshop. In particular, the Star-CCM+ CFD code was able to predict wing stall for the AIAA wing-body geometry to within 1 degree of angle of attack as compared to benchmark wind-tunnel test data. Current results show that the addition of the laminar-flow wing glove causes the gloved wing to stall much earlier than the unmodified wing. Furthermore, the gloved wing has a different stall characteristic than the clean wing, with no sharp lift drop-off at stall for the gloved wing.

computational fluid dynamics↗

Transient Modeling and Simulation of a Generic Stable Salt Reactor

A SAM system-level model of a generic stable salt reactor has been developed to investigate thermal-hydraulic behavior and safety performance under steady and transient conditions. The model integrates information generated from a reactor physics analysis using PROTEUS and PERSENT, and a computation fluid dynamics (CFD) analysis using STAR-CCM+. A loose, iterative coupling scheme between PROTEUS and SAM is implemented to calculate the equilibrium power and temperature distributions in the steady-state critical core condition. The converged steady-state model is then used in PERSENT to calculate the four reactivity feedback temperature coefficients (Doppler, fuel density, coolant density, and core radial expansion) and kinetic parameters that are needed in SAM to model the temperature feedback effects in transient simulations. Within the fully enclosed liquid fuel pins, natural convection is the dominant heat transfer mechanism. The STAR-CCM+ model of the fuel pin considers conjugate heat transfer from the liquid fuel salt to the pin cladding and external reactor coolant. The CFD results of the axial and radial temperature profiles are used to empirically determine an effective fuel salt thermal conductivity in the SAM fuel pin model so that the temperatures predicted by the SAM model match as closely as possible the CFD results. In the central region of the fuel pin, the effective thermal conductivity is as high as similar to 60 times the physical fuel salt thermal conductivity. The whole-plant SAM model is then used to simulate an unprotected station blackout transient. The results of this simulation showed that the large negative fuel axial expansion reactivity feedback reduces fission power to similar to 2.4% nominal power. The core is cooled by natural circulation, which removes heat in the core to the emergency heat removal system, and ultimately, to the ambient. However, peak fuel salt and cladding temperatures can potentially reach as high as 1500 K, albeit briefly, if the shutdown mechanism fails to operate.

stable salt reactor; transient simulations; system↗

THERMAL MODELING OF HANFORD CESIUM AND STRONTIUM CANISTERS DURING SIMULATED LOADING

A computational fluid dynamics (CFD) model was built to simulate planned testing of heater assemblies within a canister and overpack for the Hanford Lead Canister (HLC) project. The HLC is a canister storage system that will contain heaters to simulate the decay heat of nuclear material and provide the canister storage system with environmental conditions equivalent to the operating conditions on a dry storage pad. The HLC will be equipped with long-term data collection and monitoring systems to provide an early warning of corrosion, pitting, cracking, or other signs of canister degradation that might threaten the integrity of the containment boundary over the potentially long term of dry storage. An important part of the HLC development is to make pretest numerical predictions for the behavior of the heated canister during the simulated radiolytic decay heat testing, which simulates the dry storage system during loading operations. The simulated radiolytic decay heat test is planned for mid-2024 in a configuration that includes the heater assembly, overpack, and canister, but with the lids removed to allow loading cesium and strontium capsules into the canister. One of the goals of the test is to evaluate the thermal behavior of the canister and overpack assembly in the ambient air of the test facility, which will provide data critical to validating the thermal models and understanding how the HLC will perform as a system once deployed. To best approximate real-world conditions, the CFD model includes the full air volume of the mock-up truck bay the heated canister test will be performed in, enabling detailed investigation of how the heated canister affects airflow around it. Rigorous pre-deployment testing of the complete HLC cask and canister system is intended to be completed before the HLC is deployed in the 2028 timeframe. This study presents the pre-test temperature predictions of the simulated radiolytic decay heat test. A description of the heater assembly, canister, and overpack system is presented. The model was developed with the commercial CFD software STAR-CCM+. An uncertainty analysis was run with the CFD model to determine the uncertainty in the temperature predictions and provide a range over which the predicted temperatures are expected to vary. The uncertainty analysis was preformed by coupling STAR-CCM+ with the software Dakota, which provides advanced parametric analyses, including quantification of margins and uncertainty with computational models. This work is expected to provide insight into SNF canister behavior.

Carpenter-Graffy, Dina E.↗

Dynamic response of a freely rotating butterfly valve in the advanced test reactor – dynamic fluid-body interaction modeling

To regulate primary coolant flow in the Advanced Test Reactor (ATR), a butterfly valve was installed between the primary coolant pumps and the reactor core. If the mechanical connection between the valve's disk and its shaft ever fails, the disk will rotate freely. Rapid disk rotation may induce pressure surges that could damage upstream pipes. In the present work, the rotational trajectory and pressure evolution during a disk free-rotation scenario were analyzed via the dynamic fluid-body interaction (DFBI) approach in STAR-CCM+, with the movement of a solid being driven by the forces and moment/torque imposed by its surrounding fluid. Assuming a large initial opening angle, the disk accelerates slowly, but swiftly passes the closed position. As a result of the sudden valve closure, a pressure surge occurs in the upstream pipes, exceeding their maximum allowable pressure. Furthermore, the disk does not stabilize at the closed position but continually oscillates due to the unsteady nature of the coolant flow. Because of the significant and continuous water hammer effect, a fix to the butterfly valve is being implemented to prevent rapid valve closure due to failure at the valve's disk/shaft mechanical connection.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Numerical assessment of triply periodic minimal surfaces for direct air capture of carbon dioxide

Direct air capture (DAC) systems often consist of packing material wetted by a capture fluid that reacts with CO 2 in the airstream. The efficiency of the contactor is determined by a complex relationship of fluid dynamics, heat and mass transfer, contactor geometry, and chemical properties. The efficiency of the contactor must be balanced with other factors, primarily pressure drop through the system. Triply periodic minimal surfaces (TPMS) are a class of differential surfaces that have been explored in multiple engineering applications and have been shown to exhibit excellent performance when used in heat exchangers. Their tortuous path provides a high surface-to-volume ratio and favorable trade-off between contact area and pressure drop. In this work, a gyroid-type TPMS contactor was evaluated using computational fluid dynamics for a variety of geometric parameters to explore the potential benefit of TPMS shapes for DAC applications. A thin-film model was employed to model the flow and distribution of the capture solvent, allowing efficient simulations of TPMS structures at scale by eliminating the need for a computationally intensive interface capturing method. A liquid-gas mass transfer model was implemented in the commercial software STAR-CCM+ and used to predict the CO 2 capture efficiency and study the trade-off between capture performance and pressure drop through analysis of capture rates, mass transfer coefficients, and other relevant variables. TPMS contactors with a variety of geometric parameters and two capture solvent options were investigated to determine the effect of design choices on the operational performance of DAC systems. In conclusion, results showed that while contactor geometry is the dominant factor in efficiency and pressure drop, the physiochemical properties of the solvent are an important secondary influence on the contactor performance.

CFD↗

Computational Modeling of a 3D Printed Recuperator and Subsequent Experimental Loop for Supercritical Carbon Dioxide Cycles

Oak Ridge National Laboratory (ORNL), in collaboration with mechanical-thermal energy storage (mTES) provider EarthEn, a US Department of Energy (DOE) Lab-Embedded Entrepreneurship Program (LEEP) recipient at ORNL’s Innovation Crossroads 2023, is utilizing a state-of-the-art patented 3D printing technique to design an additively manufactured (AM) supercritical CO2 (sCO2) recuperator (REC) for EarthEn’s charge/discharge cycle. The AM REC will be printed at ORNL’s Manufacturing Demonstration Facility using Inconel Alloy 718 and tested on a closed-loop, ∼100 kW scale experimental facility that is under construction. The testing will compare the printed design against a commercial-off-the-shelf Printed Circuit Heat Exchanger (PCHE) REC. The design of the sCO2 facility is guided by a Modelica-based system model which is primarily dependent on the open-source TRANSFORM library developed at ORNL and uses the open-source CoolProp library for thermophysical properties of sCO2 via the External Media library. It is envisioned that an iterative process will be followed between the physical loop and the system model wherein the initial experimental data will be used to tune the model, which in turn will be used to guide future loop operation. Simultaneously, the AM REC is being designed using computer-aided design models, and it is also being analyzed for hydraulic and thermomechanical response using commercial computational fluid dynamics software, Simcenter STAR-CCM+, on highperformance computing resources.1

See, Nate [ORNL] (ORCID:0000000178581202)↗

Experimental and Computational Characterization of a Modified Sioutas Cascade Impactor for Respirable Radioactive Aerosols

Oak Ridge National Laboratory is collecting and characterizing aerosols released when spent nuclear fuel (SNF) rods are fractured in bending. An aerosol collection system was designed and tested to collect respirable sized (<10 μm aerodynamic diameter [AED]) particulates inside a hot cell facility. The setup is a modified version of the commercially available Sioutas cascade impactor, to which additional stages were added to expand the aerosol collection range from 2.5 to ~15 μm AED. To accommodate the additional stages and specific test conditions, the operating flow rate for aerosol collection was reduced, and testing was conducted by using pressure drop measurements, surrogate dust collection, and particle size characterization. The fluid flow distribution within the cascade and its stages was simulated in STAR-CCM+, and the stage-wise pressure drops obtained using the computational fluid dynamics model were then compared to experimental data. Lagrangian particle simulations were also performed, and stage-wise collection statistics were obtained from the simulation for comparison with the experimental data obtained using SNF-surrogate dust particles. The results provide valuable insights into the stage-wise particle collection characteristics of the modified cascade impactor and can also be used to improve the prediction accuracy of the manufacturer-determined analytical correlations.

aerosol modeling↗

Assessing the Heat Transfer Modeling Capabilities of CFD Software for Involute-Shaped Plate Research Reactors

The ongoing efforts to convert High-Performance Research Reactors (HPRRs) using Highly Enriched Uranium (HEU) to Low-Enriched Uranium (LEU) fuel require reliable thermal–hydraulic assessments of modified core designs. The involute-shaped fuel plates used in several major HPRRs present unique modeling challenges due to their compact core geometries and high heat flux conditions. This study evaluates the capability of three commercial CFD tools, STAR-CCM+, COMSOL, and ANSYS CFX, to predict cladding-to-coolant heat transfer using Reynolds-Averaged Navier–Stokes (RANS) methods within the thermal–hydraulic regimes of involute-shaped plate reactors. Broad sensitivity analysis was conducted across a range of reactor-relevant parameters using two turbulence models (k−ϵ and k−ω SST) and different near-wall treatment strategies. The results were benchmarked against the Sieder–Tate correlation and experimental data from historic studies. The codes produced consistent results, showing good agreement with the empirical correlation of Sieder–Tate and the experimental measurements. The findings support the use of these commercial CFD codes as effective tools for assessing the thermal–hydraulic performance of involute-shaped plate HPRRs and guide future LEU core development.

CFD↗

Intracore Natural Circulation Study in the High Temperature Test Facility

The development of the Modular High-Temperature Gas-Cooled Reactor is a significant milestone in advanced nuclear reactor technology. One of the concerns for the reactor’s safe operation is the effects of a loss-of-flow accident (LOFA) where the coolant circulators are tripped, and forced coolant flow through the core is lost. Depending on the steam generator placement, loop or intracore natural circulation develops to help transfer heat from the core to the reactor cavity, cooling system. This paper investigates the fundamental physical phenomena associated with intracore coolant natural circulation flow in a one-sixth Computational Fluid Dynamics (CFD) model of the Oregon State University High Temperature Test Facility (OSU HTTF) following a loss-of-flow accident transient. This study employs conjugate heat transfer and steady-state flow along with an SST k-ω turbulence model to characterize the phenomenon of core channel-to-channel natural convection. Previous studies have revealed the importance of complex flow distribution in the inlet and outlet plenums with the potential to generate hot coolant jets. For this reason, complete upper and lower plenum volumes are included in the analyzed computational domain. CFD results also include parametric studies performed for a mesh sensitivity analysis, generated using the STAR-CCM+ software. The resulting channel axial velocities and flow directions support the test facility scaling analysis and similarity group distortions calculation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Asymmetric Aircraft Aerodynamics Due to an Experimental Wing Glove

Aerodynamic computational fluid dynamics analysis of a wing glove attached to one wing of a business jet is presented and discussed. A wing glove placed on only one wing will produce asymmetric aerodynamic effects that will result in overall changes in the forces and moments acting on the aircraft. These changes, referred to as deltas, need to be determined and quantified to ensure that the wing glove does not have a significant effect on the aircraft flight characteristics. TRANAIR (Calmar Research Corporation, Cato, New York), a nonlinear full potential solver, and Star-CCM+ (CD-adapco, Melville, New York), a finite volume full Reynolds-averaged Navier-Stokes computational fluid dynamics solver, are used to analyze a full aircraft with and without the glove at a variety of flight conditions, aircraft configurations, and angles of attack and sideslip. Changes in the aircraft lift, drag, and side force along with roll, pitch, and yaw are presented. Span lift and moment distributions are also presented for a more detailed look at the effects of the glove on the aircraft. Aerodynamic flow phenomena due to the addition of the glove are discussed. Results show that the glove produces only small changes in the aerodynamic forces and moments acting on the aircraft, most of which are insignificant.

Hartshorn, Fletcher↗

Validation of RANS Models for Predicting Bypass Flow in Prismatic VHTRs

In prismatic Very-High Temperature Reactors (VHTRs), gaps occur between neighboring fuel assemblies referred to as bypass gaps. This work aims to measure the flow distribution between the bypass gaps between neighboring assemblies and the coolant channels within the assemblies. Computational fluid dynamics (CFD) was done using Reynolds-Averaged Navier Stokes (RANS) modeling in STAR-CCM+ to assess the ability of RANS models to accurately capture this phenomena. The RANS results were compared to experimental worked performed by Seoul National University (SNU) and Korea Atomic Energy Research Institute (KAERI) for validation. The CFD results showed good comparison with the experimental data available from SNU and flow split was characterized for multiple configurations, inlet mass flow rates, and bypass gap sizes.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

CFD Simulations of Lower Plenum Mixing

Review of model development and validation performed in the Advanced Reactor Technologies (ART) program for thermal mixing at the outlet of High Temperature Gas Reactors (HTGRs). Understanding the mixing that occurs in the lower plenum in an HTGR is necessary to facilitate design improvements and to perform reactor safety analysis. Numerical models are one possible approach to gain a better understanding of mixing in the lower plenum. Given the complexity of the geometry and the intense mixing present, it is important to perform validation of numerical models. Three models have been developed during FY2025: a porous media with Pronghorn, a Reynolds Averaged Navier Stokes (RANS) with STAR-CCM+, and a Large Eddy Simulation (LES) with NekRS. The reference facility is a scaled-down version of the lower plenum of the High Temperature Gas-Cooled Reactor - Pebble-bed Module (HTR-PM) demonstration reactor. Preliminary results of the porous media and the RANS shows general good agreement against experimental benchmark data. Future work will leverage high-fidelity results obtained through LES to guide model selection and improvements to the lower-fidelity models, with particular attention to the Pronghorn porous media.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

COMPUTATION FLUID DYNAMICS ANALYSIS FOR GENERIC SMALL MODULAR REACTOR CONTAINMENT SEPARATE EFFECTS TEST

It is desirable for fourth-generation Small Modular Reactors to be passively cooled in standard and accident operations. Passive Containment Cooling Systems can reject heat from the containment structure, without using pumps or blowers. The targeted design containment structure is a large, domed, stainless steel, cylindrical vessel. In a postulated Design Basis Accident, steam will flash inside containment. Steam condensation occurs on the inner containment wall and transfers heat through the steel containment into a large body of water known as the annular reservoir (AR) surrounding the vessel serving as the ultimate heat sink. Natural circulation drives the flow in the AR and heat will be released to the environment by evaporation of water. Unique containment geometry requires a separate effects test (SET) facility for the verification and validation of the computer code and evaluation model development and assessment for reactor licensing efforts. In this study, STAR-CCM+, a computational fluid dynamics (CFD) code was used to inform the decision-making process on the design of the SET. The CFD simulation modeled, a two-phase turbulent flow with fluid film development and heat transfer for different containment geometries. The Reactor Excursion and Leak Analysis Program will also be used in a code-to-code verification against the CFD results.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Simulations of Bypass Flow in Prismatic VHTRs

In prismatic Very-High Temperature Reactors (VHTRs), gaps occur between neighboring fuel assemblies referred to as bypass gaps. This work aims to measure the flow distribution between the bypass gaps between neighboring assemblies and the coolant channels within the assemblies. Computational fluid dynamics (CFD) was done using Reynolds-Averaged Navier Stokes (RANS) modeling in STAR-CCM+ to assess the ability of RANS models to accurately capture this phenomena. The RANS results were compared to experimental worked performed by Seoul National University (SNU) and Korea Atomic Energy Research Institute (KAERI) for validation. The CFD results showed good comparison with the experimental data available from SNU and flow split was characterized for multiple configurations, inlet mass flow rates, and bypass gap sizes.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Dynamic response of a freely rotating butterfly valve in the advanced test reactor − dynamic coefficients modeling

Here, in evaluating the water hammer issue pertaining to the primary-coolant-regulating butterfly valve in the Advanced Test Reactor, the dynamic fluid body interaction (DFBI) approach was implemented in the analysis covered in Part I. Although DFBI modeling accurately and simultaneously solved the dynamic motion of the valve’s disk along with the flow field of the surrounding fluid, it shed little light on the reason behind such motion. For Part II, the reacting torque of the fluid on the disk was decomposed into representations of the dynamic coefficients in terms of stiffness, damping, and added mass. These were evaluated via simulations with steady-state static (stiffness), constant angular speed (damping), and variable angular speed (added mass) disks. Substituting the dynamic coefficients into Newton’s second law enabled the response trajectories to be obtained. Stable (by average) and unstable equilibrium positions and thrust tendencies of the valve were determined based on the stiffness coefficient (or static torque), the response amplitude was dampened or enlarged by the damping coefficient (minorly affected by added mass), and the response frequency was altered by the damping and added mass coefficients. Although the dynamic coefficient approach renders slightly different trajectories, due to the averaging effect of the torque in comparison to the DFBI method, the overall trend of the response aligns with the DFBI simulation, thus confirming the conclusion in Part I that a fix to the current butterfly valve is necessary.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

High-fidelity forced convection simulations of the University of Wisconsin–Madison air-cooled reactor cavity cooling system

Among the various types of advanced nuclear technologies that exist, high-temperature gas-cooled reactors (HTGRs) stand out for their co-generation capabilities and exceptional passive safety systems. HTGRs rely on a reactor cavity cooling system (RCCS) to remove decay heat from the reactor pressure vessel (RPV) during the course of long-term transients. Several studies have focused on experimental and numerical modeling of the RCCS; however, the literature reveals a notable gap when it comes to high-fidelity simulations such as direct numerical simulations (DNS) or large eddy simulation (LES) models of the RCCS. An LES model was developed for forced convection inside the RCCS so as to obtain a high-fidelity representation of the RCCS at a scale never before attempted. Furthermore, the LES model was compared against three different Reynolds-averaged Navier–Stokes (RANS) models (Realizable k − ϵ, k − ω SST, and Reynolds stress model [RSM]). This comparison verified the robustness and accuracy of the turbulence modeling approach of the RANS models for the RCCS. Finally, based on the comparison between the LES and the RANS models, the k − ω SST RANS model of the experimental facility was developed and compared against the available experimental data.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗