Search NASA⌕ Search

SEARCH · Search NASA

Results for “STATIC LOADS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Online Static Load Model Estimation in Distribution Systems: Preprint

The paper focuses on parameter identification for time varying voltage dependent polynomial load models, namely the constant impedance (Z), constant current (I), and constant power (P), in the distribution systems. Typically, parameter identification has been done for aggregated loads at substations for the transmission planning studies. Given the higher voltage volatility faced by active distribution systems, this paper takes the load model estimation to the distribution networks. The paper assumes the presence of measurements at the distribution nodes from various sources, each at varying temporal resolutions. Least squares estimation (LSE) method with bounded variables is used to convert the measurements into ZIP parameter estimations for loads at various locations of the feeder. The results and discussions focus on some of the estimation issues faced in a distribution system due to varying voltage sensitivities of loads along a feeder, measurement resolution, impact of window size and sampling rate of measurement data, and the use of dynamic simulations to create synthetic measurement data in the absence of real ones.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Damage of Elastomeric Matrix Composites (EMC-rubbers) Under Static Loading Conditions: Experimental and Numerical Study

Elastomeric matrix composites (EMC-rubbers) are considered as isotropic hyper elastic incompressible materials under static loading conditions. As a rubber material element cannot be extended to an infinite stretch ratio, a damage mechanism at large strain is considered. The phenomenon of cavitation plays an important role in the damage of EMCs and influences the toughening mechanism of rubber-modified plastics. Indeed, cavitation in elastomers is thought to be initiated from flaws, which grow primarily due to a hydrostatic tensile stress and ahead of the crack; there will not only be a high stress perpendicular to the plane of the crack but also significant stress components in the other direction. However, there exists historically much discussion on the evolution of the cavitation in elastomers under monotonic and/or static solicitation. Mainly, cavitation instability occurs when the stress levels are sufficiently high so that the void expansion rate becomes infinitely large. Many research works have been performed to understand the effects of rubber cavitation on toughening of plastics. In fact, the cavitation phenomenon is not well known in detail. The most popular idea states that the cavitation is related to the existence of the gas bubbles trapped in the material during the production stage and the growing of the cavities would then be the result of the growing gas bubbles. Further, instable failure mechanism at the end of the cavitation is not well known too.

36 MATERIALS SCIENCE↗

Static load test of Arquin-designed CMU wall.

The Arquin Corporation has developed a new method of constructing CMU (concrete masonry unit) walls. This new method uses polymer spacers connected to steel wires that serve as reinforcing as well as means of accurately placing the spacers so that the concrete block can be dry stacked. The hollows of the concrete block used in constructing the wall are then filled with grout. As part of a New Mexico Small Business Assistance Program (NMSBAP), Sandia National Laboratories conducted a series of tests that statically loaded wall segments to compare the Arquin method to a more traditional method of constructing CMU walls. A total of 12 tests were conducted, three with the Arquin method using a W5 reinforcing wire, three with the traditional method of construction using a number 3 rebar as reinforcing, three with the Arquin method using a W2 reinforcing wire, and three with the traditional construction method but without rebar. The results of the tests showed that the walls constructed with the Arquin method and with a W5 reinforcing wire withstood more load than any of the other three types of walls that were tested.

36 MATERIALS SCIENCE↗

Influence of fiber inclination angle on bond-slip behavior of different alkali-activated composites under dynamic and quasi-static loadings

This study investigates the influence of inclination angle (0° and 45°) on the interfacial bond-slip behavior of macro steel fibers (straight, hooked end-deformed and length-deformed) and length-deformed polypropylene fibers reinforced in fly-ash and metakaolin based alkali-activated composites (AACs) under quasi-static and dynamic loadings. AACs demonstrate superior peak bond strength and toughness compared to cement composites regardless of fiber type and loading rate. Results also show that straight steel fiber exhibits a complete pullout in AACs. The amount of deformation of the fibers (deformation ratio) determined the failure type at different inclination angle and loading rate, thus governing the peak load and energy absorption. Depending on the fiber orientation, premature fiber rupture or matrix cracking is observed under dynamic loading in AACs due to matrix brittleness. The fiber failure modes in dynamic pullout are no different from those observed in the quasi-static pullout in AACs.

36 MATERIALS SCIENCE↗

Evaluating Zoltan for Static Load Balancing on BlueGene Architectures

The purpose of this TechBase was to evaluate the Zoltan load-balancing library from Sandia National Laboratories as a possible replacement for ParMetis, which had been the load balancer of choice for nearly a decade but does not scale to the full 64,000 processors of BlueGene/L. This evaluation was successful in producing a clear result, but the result was unfortunately negative. Although Zoltan presents a collection load-balancing algorithms, none were able to meet or exceed the combined scalability and quality of ParMetis on representative datasets.

99 GENERAL AND MISCELLANEOUS↗

A combined ensemble-volume average homogenization method for lattice structures with defects under dynamic and static loading

In the study of lattices structures, both experiments and numerical simulations are often conducted with small samples. Using combined ensemble and volume averaging, this work introduces a method to extract a macroscopic constitutive response of a lattice material from numerical simulations performed in periodic domains. The domain size needed to obtain statistically accurate results is investigated. Similar to molecular dynamics, the concept of the virial stress is introduced after homogenized equations are derived using the ensemble averaging method. Under static conditions, the virial stress is shown to agree with the volume averaged solid stress. Using the homogenization method, constitutive relations for this stress can be obtained from systems with uniform strains. Application of such obtained constitutive relations to more general cases results in an error proportional to the square of the ratio between the lattice length scale and the macroscopic length scale. Taking advantage of this property, numerical simulations are performed in systems with a uniform gradient of the average velocity. The volume average method is then used to accelerate convergence when studying lattices with defects. To avoid the artificial numerical time scale from the size of a representative volume element divided by the wave speed, a numerical scheme is developed to enforce a spatially uniform velocity gradient within the computational domain while allowing fluctuations of the velocity or displacement to develop naturally. To account for probability distribution of lattice defects, the stress is calculated as the ensemble-volume averaged value. For dynamic systems, energy dissipation properties are also studied.

36 MATERIALS SCIENCE↗

Representative Modules for Accelerated Thermal Cycling and Static Load Testing

In this work, we explore the influence of module size on the rate of interconnect solder bond thermomechanical fatigue (TMF) damage and the probability of cell fracture. For the solder bond TMF damage evaluation, structural mechanics models of crystalline silicon PV models are created to solve with the Finite Element Method. For the probability of cell fracture evaluation, Weibull analysis and weakest link theory are employed to resolve the probability of crystalline silicon PV cell fracture when measured as bare cells and when stressed in reduced- and full-sized modules. Results conclusively demonstrate that the rate of solder bond TMF damage is independent of module size, interconnect location across the cell and cell location across the module and that smaller, representative, modules must be loaded to a much higher level than their parent full-sized modules to achieve an equivalent driving force for cell fracture.

accelerated testing↗

Phase transformation of PZST-86/14-5-2Nb ceramic under quasi-static loading conditions.

Specimens of poled and unpoled PZST ceramic were tested under hydrostatic loading conditions at temperatures of -55, 25, and 75 C. The objective of this experimental study was to obtain the electro-mechanical properties of the ceramic and the criteria of FE (Ferroelectric) to AFE (Antiferroelectric) phase transformations of the PZST ceramic to aid grain-scale modeling efforts in developing and testing realistic response models for use in simulation codes. As seen in previous studies, the poled ceramic from PZST undergoes anisotropic deformation during the transition from a FE to an AFE phase at -55 C. Warmer temperature tests exhibit anisotropic deformation in both the FE and AFE phase. The phase transformation is permanent at -55 C for all ceramics tests, whereas the transformation can be completely reversed at 25 and 75 C. The change in the phase transformation pressures at different temperatures were practically identical for both unpoled and poled PZST specimens. Bulk modulus for both poled and unpoled material was lowest in the FE phase, intermediate in the transition phase, and highest in the AFE phase. Additionally, bulk modulus varies with temperature in that PZST is stiffer as temperature decreases. Results from one poled-biased test for PZST and four poled-biased tests from PNZT 95/5-2Nb are presented. A bias of 1kV did not show noticeable differences in phase transformation pressure for the PZST material. However, with PNZT 95/5-2Nb phase transformation pressure increased with increasing voltage bias up to 4.5kV.

36 MATERIALS SCIENCE↗

Online Static Load Model Estimation in Distribution Systems

This paper focuses on parameter identification for time-varying voltage-dependent polynomial load models in distribution systems—namely, the constant impedance (Z), constant current (I), and constant power (P). The paper assumes the presence of measurements at the distribution nodes from various sources, each at varying temporal resolutions. The least- squares estimation method with bounded variables is used to convert the measurements into ZIP parameter estimations for loads at various locations on the feeder. The results and discussions focus on some of the estimation issues faced in a distribution system caused by varying voltage sensitivities of loads along a feeder, measurement resolution, impact of window size and sampling rate of measurement data. Finally, the paper uses dynamic simulations data (synthetic high-resolution measurements) to further improve the estimation results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Static Proof Load Testing of the Sandia SWiFT 13m Blades

Pre-flown Vestas V-27 wind turbine blades will be used at the new Sandia SWiFT test facility near Lubbock,Texas. Proof load testing the blades in the flapwise direction was needed to verify the blades are still fit for service after 20 years offield operation. Testing was conducted in Building 252(A60)at the NWTC near Boulder,Colorado, between Oct 28(arrival of blades)to Dec 4,2015(completion of testing), under NREL subtasks WE141A50 and WE161A50. Single-point, quasi-static loads were applied to the blade at three independent load stations of 5.92 m, 8.69 m, and 11.62 m, using the facility gantry crane to apply the test load in the positive flapwise direction (low pressure surface in compression). Following the flapwise load cases, a single point load was applied at the 8.69 m station in the negative edgewise direction (leading edge in compression). No damage was observed due to the introduction of the proof loads. Several small pops were heard during testing on each blade, primarily during loading at the 8.69 m station. Compliance (deflection per load) varied less than 7% between all blades for all load cases. Table 3-1 summarizes the applied loads, deflections, and compliance for each blade for the flapwise test cases. Applied test loads are the raw load cell reading minus the total tare load (combined tare load of saddle and tare load for blade self weight). Deflection here is average deflection from both LE and TE string pot data.

17 WIND ENERGY↗

Towards Polymer-Free, Femto-Second Laser-Welded Glass/Glass Solar Modules

This project explores the use of femto-second (fs) lasers to form glass-to-glass welds for hermetically sealed, polymer-free solar modules. Low iron solar glass coupons were welded together without the use of glass filler using a fs laser with dedicated optics to elongate the focal plane parallel to the incident beam. The resulting welds were then stress tested to failure to reveal the critical stress intensity factor, KIc. These values were used in a structural mechanics model of a 1 m by 2 m glass/glass module under a simulated static load test. The results show that the fs laser welds are strong enough for a suitably framed module to pass the IEC 61215 static load test with a load of 5400 Pa. Key to this finding is that the module must be framed and braced, and the glass must be ribbed to allow pockets for the cells and welds inside the border of the module. The result is a module design that is completely polymer-free, hermetically sealed, has improved thermal properties, and is easily recycled.

femto-second laser welded↗

Effects of Photovoltaic Module Materials and Design on Module Deformation Under Load

Static structural finite element models of an aluminum-framed crystalline silicon (c-Si) photovoltaic (PV) module and a glass-glass thin film PV module were constructed and validated against experimental measurements of deflection under uniform pressure loading. Parametric analyses using Latin Hypercube Sampling (LHS) were performed to propagate simulation input uncertainties related to module material properties, dimensions, and manufacturing tolerances into expected uncertainties in simulated deflection predictions. This exercise verifies the applicability and validity of finite element modeling for predicting mechanical behavior of solar modules across architectures and enables computational models to be used with greater confidence in assessment of module mechanical stressors and design for reliability. Sensitivity analyses were also performed on the uncertainty quantification data sets using linear correlation coefficients to elucidate the key parameters influencing module deformation. This information has implications on which materials or parameters may be optimized to best increase module stiffness and reliability, whether the key optimization parameters change with module architecture or loading magnitudes, and whether parameters such as frame design and racking must be replicated in reduced-scale reliability studies to adequately capture full module mechanical behavior.

14 SOLAR ENERGY↗