Search NASA⌕ Search

SEARCH · Search NASA

Results for “STD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Mil-Std-464C and Mil-Std-464D Electromagnetic Radiation Environment Evaluation

Many systems derive their electromagnetic radiation (EMR) environments from Mil-Std-464C or Mil-Std-464D, Electromagnetic Environmental Effects Requirements for Systems. This standard defines several EMR environments based on the type of system and expected application. Many nuclear weapon (NW) systems reference the ordnance environments as the starting point for their functional EMR requirements, since any item intended to go into Department of Defense (DOD) custody is expected to be certified hazards of electromagnetic radiation to ordnance (HERO) safe when exposed to the environments listed in Mil-Std-464 Table 9. This environment is defined as the envelope of all sources any system in DOD custody may ever encounter, however, and may include sources that are not relevant for a particular system. This document is intended to provide additional clarity on the Mil-Std-464C and Mil-Std-464D EMR environments, specifically the driving sources for the maximum ordnance levels. This supplementary information may be used to guide tailoring of relevant environments or application to different systems with the additional consideration of any shielding that may reduce the external environments defined in the military standard.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Background Information on the Protection Requirements in IEEE Std 1547-2018

As the DER penetration level has risen significantly in recent times, parameter settings and configuration of installed DERs are having direct impact on local electric distribution utilities as well as bulk power systems during normal and abnormal grid conditions. On the other hand, all grid-connected DERs in the United States of America must conform to the interconnection requirements prescribed in the IEEE Std 1547-2018. Because of these reasons, it is crucial to understand the expected DER performance during abnormal grid conditions considering the requirements of the IEEE Std 1547-2018. The aim of this document is twofold: (1) to summarize requirements in IEEE Std 1547-2018 having direct implications in distribution network protection, and (2) to provide the reader with knowledge and information that will be required for users to apply the requirements specified. Since the focus of this document is on distribution network protection in the presence of DERs, it is assumed that the readers have basic understanding of distribution network protection as well as working principles of DERs. This document starts with a brief introduction on protection systems for distribution network followed by a discussion on the impact of DER on the protection systems. Current practices to provide network protection in the presence of DER is briefly discussed. The document then explores the DER performance requirements in IEEE Std. 1547-2018; especially on those related to distribution network protection. Section 6.1 in IEEE Std. 1547-2018 provides an overview of capabilities and control requirements for DER under abnormal operating conditions. This section also introduces abnormal operating performance categories I, II, III. The DER response to various types of faults and grid conditions such as short-circuit faults and open phase conditions are discussed in section 6.2 in the standard while requirements for coordination with the Area EPS reclosing scheme are provided in section 6.3. Section 6.4 in the IEEE Std 1547-2018 specifies requirements for mandatory voltage tripping and ride-through requirements during low and high voltage disturbances and section 6.5 specifies similar requirements for low and high frequency disturbances. IEEE Std. 1547 requires that the conformance of the DERs to IEEE Std 1547-2018 requirements should be verified in accordance with IEEE Std. 1547. 1. There are several parameters and settings of DERs that need to be properly selected for reliable operation during abnormal grid condition while applying the requirements of IEEE Std 1547-2018. Key decisions for proper selections of parameter and settings are: 1. Determination of required DER abnormal operating performance category, 2. Determination of DER response (shall trip) to abnormal voltages and 3. Determination of DER response (shall trip) to abnormal frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DER Inverter Control Fault Ride Through Model in Accordance with IEEE 1547-2018 Std

Distributed Energy Resources (DER) with smart inverters are becoming more prevalent as the need for renewable energy and grid stability increases. An important challenge arises when considering that inverterbased generation methods contribute less current during faults, rendering traditional overcurrent protection unsatisfactory. DERs have fault ride-through requirements when operating in high or low voltage, outlined by IEEE Std. 1547-2018. Faults cause the voltage to reach abnormal steady state magnitudes, depending on the fault resistance and fault type. There are several high voltage and low voltage ride-through zones defined by IEEE Std. 1547-2018. Each zone’s ride through duration decreases as the applicable voltage measurement, i.e., the phase RMS voltage, deviates from its nominal value. This presentation demonstrates the implementation of IEEE Std. 1547-2018 high and low voltage ridethrough grid support functions using a preexisting RSCAD model, discussing the challenges presented during this process. The implemented controls monitor the filtered phase voltages to have a more accurate reading of the applicable voltages. The controls sense the duration that the applicable voltage remains in a specific zone. The breaker trips and ceases energization to the grid when the duration is exceeded. The standard allows the operator to adjust the ride-through times and voltage zones from the default settings. These ranges are implemented into the runtime, which acts as the operator’s SCADA. The results show the accuracy of the voltage measurements, which remain within the IEEE Std. 1547-2018 for all cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources: Preprint

This study addresses the compliance of Inverter-based Resources (IBRs) with the IEEE Std 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a comprehensive controller development framework. This framework caters to maintaining ride-trhough operation or implementing strategic disconnections in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller framework is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

IEEE Std 2800↗

DOE-STD-1112-2019 Review for the 2020 DOELAP Radiobioassy Program Assessment

In compliance with DOE-STD-1112-2019 section 4.6(i) and in preparation for a 2020 DOELAP assessment of Radiobioassay Program, the QA officer, WBC/SLAB Group Leader, BLAB/RML Group Leader, and WBC/SLAB Health Physicists reviewed the program’s performance in accordance with the criteria found in DOE-STD-1112-2019 and in the accompanying checklist provided to the DOELAP assessor community in January 2020.

61 RADIATION PROTECTION AND DOSIMETRY↗

Impact to Groundwater All-Pathways Dose Estimates for the Remote-Handled Low-Level Waste Disposal Facility Performance Assessment Using Updated Dose Coefficients from DOE-STD-1196-2022

The Performance Assessment (PA) for the Remote-Handled Low-Level Waste (RHLLW) Disposal Facility at Idaho National Laboratory (INL) was completed in 2018 (DOE-ID 2018) using dose coefficients from U.S. Department of Energy (DOE) Standard DOE-STD-1196-2011 (DOE 2011). Internal and external dosimetry was updated in 2021 and a new technical standard was published in 2022 (DOE-STD-1196-2022) (DOE 2022). This technical memorandum provides a comparison of the ingestion dose coefficients between those published in DOE (2011) and those published in DOE (2022). The dose coefficients in DOE (2022) were then used to calculate the all-pathways dose for the groundwater pathway and the results between the doses published in the 2018 PA and those calculated using the updated dose coefficients in DOE (2022) were compared. Several other issues in the 2018 RHLLW Disposal Facility PA were also addressed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources

This study addresses the compliance of Inverter-based Resources (IBRs) with IEEE Standard 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a controller development framework for abnormal grid conditions. This framework caters to maintaining ride-through operation in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller frame-work is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

IEEE Std 2800↗

Examining the Performance of MIL-STD-188-110D Waveform 0 Against FBMC-SS Over Skywave HF Channels

This paper provides a comprehensive performance comparison between a current robust military waveform; namely, MIL-STD-188-110D, Waveform 0, and a filter bank multicarrier spread-spectrum (FBMC-SS) waveform proposed for communications through ionospheric/skywave HF channels. Waveform 0 is effectively a direct sequence spread spectrum waveform that uses Walsh multi-codes to enhance the information transmission rate. It may thus be referred to as Walsh-DSSS. FBMC-SS, on the other hand, makes use of filter banks to provide excellent performance when the received signal is subject to partial band interference. Successful application of FBMC-SS for communications across skywave HF channels has been previously demonstrated, both theoretically and through experimental work. However, very little has been done to contrast FBMC-SS against Walsh-DSSS. The goal of this paper is to first add new features to FBMC-SS to bring it on par with Walsh-DSSS. These features include: (i), introduction of multi-codes that achieve a comparable (or better) data rate to Walsh-DSSS; and (ii), addition of a scrambling step applied to the multi-codes to make the receiver detection robust against widely spread multipaths. With this established, in the second part of the paper, we examine the performance of the developed FBMC-SS against Walsh-DSSS when both are applied for communications across skywave HF channels. The two waveforms are compared both through a theoretical study and through experimental works across several skywave channels ranging from hundreds to thousands of kilometers.

42 ENGINEERING↗

Proposal to use the DOE-STD-3009-2014 Methodology to Prepare the Documented Safety Analysis (DSA) for Research Reactor Nuclear Facilities

Sandia National Laboratories (SNL) personnel operate a low power research reactor (the Annular Core Research Reactor, or ACRR), and a zero-power critical experiment assembly referred to as CX. In accordance with 10 CFR 830, Subpart B, Appendix A, the acceptable methodology for developing a Documented Safety Analysis (DSA) for DOE nuclear reactors is the Nuclear Regulatory Commission’s (NRC’s) Regulatory Guide 1.70 (RG 1.70). RG 1.70 does not address certain areas required by 10 CFR 830 and expected by DOE (e.g., full facility hazard analysis).Thus, the current DSAs for SNL’s reactor nuclear facilities are based on RG 1.70, but also of necessity supplemented by DOE-STD-3009-94 methods. SNL personnel, in consultation with the National Nuclear Security Administration (NNSA) Sandia Field Office (SFO), have concluded that an alternate methodology is preferred to RG 1.70. The details of the proposal, and the reasons motivating its development, are discussed in the order described below. The proposed alternate methodology will be applicable to the ACRR and the CX (i.e., it will be applicable to nuclear facilities in which a reactor and/or a critical assembly will be operated).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Informative Background on the Interoperability Requirements in IEEE Std 1547-2018

The intent of this document is to support local authorities governing interconnection requirements in adopting the most current requirements for interconnecting distributed energy resources (DERs) to the electric distribution system, as specified in the Institute of Electrical and Electronics Engineers Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces (IEEE Std 1547-2018 ). To create interconnection rules that successfully address policy goals, market trends, and technical requirements, electric service regulators need to be well informed of DER integration considerations. Interconnection processes and technical issues often overlap; the two are not easily segregated, and they are often considered and evaluated concurrently within the context of interconnection rulemaking. Accordingly, this document addresses both the technical issues and related process considerations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Overview of Issues Related to IEEE Std 1547-2018 Requirements Regarding Voltage and Reactive Power Control

The revised Institute of Electrical and Electronics Engineers (IEEE) 1547 Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces (IEEE Std 1547-2018) was published in April 2018. This standard is one of the foundational documents in the United States needed for integrating distributed energy resources (DERs), including solar energy systems, with the electric distribution grid. The revised standard contains 11 chapters (clauses) and 8 annexes that comprise 136 pages. The revision is significantly different from the 2003 version, and it contains new concepts and new technical requirements. Each clause specifies information or requirements that apply to certain aspects important to the interconnection of DERs to the electric power system. Implementing the requirements necessitates a careful study of the underlying technical concept and requires the appropriate information required to calculate relevant settings and configurations. Various stakeholders have different roles in implementing the standard, and portions of the standard are directed toward a specific audience who must possess specialized information and technical training to use and apply the requirements. This document aims to (1) summarize a specific portion of the standard as concisely as possible and (2) provide the reader with introductory knowledge and information to support the utilization of the requirements.

14 SOLAR ENERGY↗

Background Information on the Power Quality Requirements in IEEE Std 1547-2018

The revised Institute of Electrical and Electronics Engineers (IEEE) 1547-2018, Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces, was published in April 2018. This standard is one of the foundational documents in the United States needed for integrating distributed energy resources (DERs), including solar energy systems, and energy storage systems with the electric distribution grid. The revised standard contains 11 chapters (clauses) and 8 annexes that comprise 136 pages. The revision is significantly different from the 2003 version, and it contains new concepts and new technical requirements. Each clause specifies information or requirements that apply to certain aspects that are important to the interconnection of DERs to the electric power system. Implementing the requirements necessitates a careful study of the underlying technical concepts and requires appropriate information to calculate relevant settings and configurations. This document provides informative material on the requirements related to electrical power quality in IEEE Std 1547-2018, with the intent to equip the reader with basic knowledge and background information to improve understanding and use of the requirements specified.

14 SOLAR ENERGY↗

Technical Basis for Extending Storage Life of DOE-STD-3013 Containers

The U.S. Department of Energy (DOE) Technical Standard for Stabilization, Packaging, and Storage of Plutonium-Bearing Materials, DOE-STD-3013 [USDOE 2018], provides requirements for packaging stabilized metals, alloys, and oxides containing at least 30 weight percent (wt%) plutonium (Pu) plus uranium for storage for up to 50 years. This document provides the technical basis for extending that storage duration to up to 100 years for metals and alloys, and oxides that do not present a corrosion risk to the integrity of the container.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technical Basis for Proposed Changes to DOE-STD-1194-2019, Nuclear Material Attractiveness Determination and Categorization

The Department of Energy (DOE)’s Technical Standard DOE-STD-1194-2019 (dated September 2019), Nuclear Materials Control and Accountability, provides key guidance for the determination of Special Nuclear Material (SNM) attractiveness levels. Attractiveness levels are a key component in the security categorization of SNM processed, used, and stored at DOE facilities. Upon review, the writing team identified specific components relating to the determination of attractiveness levels that could be modified to improve clarity, reduce burden on sites, and/or better align with the graded safeguards principle that is central to the DOE’s nuclear security program. The report outlines the original verbiage, issues with implementation of that verbiage, proposed new verbiage, and the expected benefits thus serving as the technical basis for the proposed changes.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Studying the Impact of Momentary Cessation of IBRs Compliant With IEEE Std. 2800-2022 on Transmission Line Protection Elements

This paper examines the impact of inverter-based resource (IBR) momentary cessation timing on transmission system protection relays. IEEE Std. 2800 mandates voltage ride-through, requiring IBRs to remain online during voltage disturbances. However, for severe voltage dips (|V| = 0.1 p.u.), the standard permits current blocking. In practice, vendors implement momentary cessation with varying delays, potentially affecting relay operation if IBRs cease too early. This article studies the impact of the time IBRs enter momentary cessation on transmission line protective relays. Using an electromagnetic transient (EMT) simulation, this study models IBR momentary cessation with tunable delays in a realistic transmission network. COMTRADE files generated from EMT simulations are analyzed in MATLAB using detailed protective relay models. Results indicate that IBRs must sustain operation for at least one cycle to ensure proper relay response; otherwise, relays may fail to oper- ate. These findings guide IBR vendors in optimizing momentary cessation settings to enhance transmission line protection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Challenges of Interpreting and Applying New IPC-J-STD-001 Cleanliness Standards in High-Reliability Applications

The electronics industry has rapidly and widely embraced the replacement of ROSE testing with an SIR-focused approach to testing for certification of a qualified manufacturing plan. These new cleanliness documentation standards, housed in IPC J-STD-001 Rev. H, have just begun to impact electronics manufacturers as design and production teams work through how to meet them. This research focuses on the particular challenges of applying these new standards in high-reliability product applications, through the lens of interpreting SIR test results and what they mean for process capability, repeatability and diagnosing a need for process changes. The experiments examined a variety of factors that influence SIR results and suggest areas where SIR test plans can be greatly improved.

Capen, William↗

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources

This study addresses the compliance of Inverter-based Resources (IBRs) with IEEE Standard 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a controller development framework for abnormal grid conditions. This framework caters to maintaining ride-through operation in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller framework is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

grid↗

Bus repeater and bit injector for MIL-STD-1553/1760 communications bus

A fault insertion device (FID) comprises a transceiver and an FPGA. The transceiver receives signals from a MIL-STD-1553/1760 communications bus. The FPGA evaluates the signals received from the communications bus against a set of rules stored by the FPGA. Based upon the set of rules, the FPGA can selectively modify messages received from the communications bus prior to transmission to a remote terminal or a bus controller that is configured to communicate on the communications bus.

Krein, Jason P.↗